Hongchang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hongchang Wang has a total of 289 co-authors. Here are the top co-authors by number of shared publications:
- Kawal Sawhney
Diamond Light Source, Didcot, United Kingdom
26 shared publications Kawal Sawhney
Harwell Science and Innovation Campus, Diamond Light Source Ltd, Didcot, UK
21 shared publicationsYogesh Kashyap
Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India
10 shared publications- Sebastien Berujon
European Synchrotron Radiation Facility CS 40220 F-38043 Grenoble cedex 9 France
7 shared publications - Simon G. Alcock
Diamond Light Source Ltd
6 shared publications - Ioana-Theodora Nistea
Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom
5 shared publications
Latest Publications
- Open Access
- 29 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
An achromatic neutron lens
Neutrons provide exceptional insight into materials, owing to their sensitivity to light elements, isotopic composition, magnetic moments, and high-penetration. However, neutron sources are polychromatic and of low brightness. Neutron optics provides a route to address these limitations by focusing, and to date, various types of neutron optics have been developed based on reflection, refraction, diffraction, and magnetism. Notably, compound refractive lenses and Fresnel zone plates have been demonstrated for imaging, yet their severe chromatic aberration under polychromatic beams has prevented their widespread use and limits progress towards true high-resolution neutron microscopy. Here, we demonstrate an achromatic neutron lens for full-field neutron microscopy. This development overcomes the intrinsic sample-detector distance constraint in pinhole-based radiography. The lens magnification enables the use of efficient detection systems without loss of spatial resolution and establishes a pathway towards high-resolution neutron microscopy. We anticipate the neutron achromat will advance a broad range of neutron methods.
- 29 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessAn achromatic neutron lens
Neutrons provide exceptional insight into materials, owing to their sensitivity to light elements, isotopic composition, magnetic moments, and high-penetration. However, neutron sources are polychromatic and of low brightness. Neutron optics provides a route to address these limitations by focusing, and to date, various types of neutron optics have been developed based on reflection, refraction, diffraction, and magnetism. Notably, compound refractive lenses and Fresnel zone plates have been demonstrated for imaging, yet their severe chromatic aberration under polychromatic beams has prevented their widespread use and limits progress towards true high-resolution neutron microscopy. Here, we demonstrate an achromatic neutron lens for full-field neutron microscopy. This development overcomes the intrinsic sample-detector distance constraint in pinhole-based radiography. The lens magnification enables the use of efficient detection systems without loss of spatial resolution and establishes a pathway towards high-resolution neutron microscopy. We anticipate the neutron achromat will advance a broad range of neutron methods.
- Open Access
- 8 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Speckle-based curvature optical metrology
Advanced metrology methods are continually being developed and refined to meet the demanding quality standards of high-performance X-ray mirrors. Among these, interferometric techniques are the most widely used for measuring the height maps of optical surfaces. However, they often encounter limitations when applied to strongly curved or freeform surfaces, primarily due to high fringe density caused by steep slope. To address these challenges, we have developed a laser Speckle-based Curvature Optical Metrology instrument (SCOM) for measuring the two-dimensional surface curvature maps. This technique offers an alternative for characterizing complex optical surfaces by using a digital image correlation algorithm to extract curvature information from the speckle pattern, which effectively acts as a set of wavefront markers. We have demonstrated the effectiveness of this method for measuring strongly curved mirrors with a radius of curvature from 10 m down to 100 mm. Additionally, we have applied this technique to online deterministic figuring of optical surfaces, in-situ stress measurements during multilayer deposition processes, and the characterization of deformable mirrors. This technique shows great promise not only for high precision metrology of X-ray mirrors used in synchrotron radiation facilities, free-electron lasers, and space and astronomical observatories, but also for freeform optical components in advanced industrial applications.
- 8 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Open AccessSpeckle-based curvature optical metrology
Advanced metrology methods are continually being developed and refined to meet the demanding quality standards of high-performance X-ray mirrors. Among these, interferometric techniques are the most widely used for measuring the height maps of optical surfaces. However, they often encounter limitations when applied to strongly curved or freeform surfaces, primarily due to high fringe density caused by steep slope. To address these challenges, we have developed a laser Speckle-based Curvature Optical Metrology instrument (SCOM) for measuring the two-dimensional surface curvature maps. This technique offers an alternative for characterizing complex optical surfaces by using a digital image correlation algorithm to extract curvature information from the speckle pattern, which effectively acts as a set of wavefront markers. We have demonstrated the effectiveness of this method for measuring strongly curved mirrors with a radius of curvature from 10 m down to 100 mm. Additionally, we have applied this technique to online deterministic figuring of optical surfaces, in-situ stress measurements during multilayer deposition processes, and the characterization of deformable mirrors. This technique shows great promise not only for high precision metrology of X-ray mirrors used in synchrotron radiation facilities, free-electron lasers, and space and astronomical observatories, but also for freeform optical components in advanced industrial applications.
- Open Access
- 11 February 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (6) , 063601
Cavity Controls Core-to-Core Resonant Inelastic X-Ray Scattering
X-ray cavity quantum optics with inner-shell transitions has been limited by the spectral overlap between resonant and continuum states. Here, we report the first experimental demonstration of cavity-controlled core-to-core resonant inelastic x-ray scattering (RIXS). We suppress the absorption-edge effects by monitoring the RIXS profile, thereby resolving the resonant state from the overlapping continuum. We observe distinct cavity-induced energy shifts and cavity-enhanced decay rates in the 2 p 3 d RIXS spectra of WSi 2 . These effects, manifesting as stretched or shifted profiles in the RIXS planes, enable novel spectroscopic applications via cavity-controlled core-hole states. Our results establish core-to-core RIXS as a powerful tool to manipulate inner-shell dynamics in x-ray cavities, offering new avenues for integrating quantum optical effects with x-ray spectroscopy.
- 11 February 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (6) , 063601
Open AccessCavity Controls Core-to-Core Resonant Inelastic X-Ray Scattering
X-ray cavity quantum optics with inner-shell transitions has been limited by the spectral overlap between resonant and continuum states. Here, we report the first experimental demonstration of cavity-controlled core-to-core resonant inelastic x-ray scattering (RIXS). We suppress the absorption-edge effects by monitoring the RIXS profile, thereby resolving the resonant state from the overlapping continuum. We observe distinct cavity-induced energy shifts and cavity-enhanced decay rates in the 2 p 3 d RIXS spectra of WSi 2 . These effects, manifesting as stretched or shifted profiles in the RIXS planes, enable novel spectroscopic applications via cavity-controlled core-hole states. Our results establish core-to-core RIXS as a powerful tool to manipulate inner-shell dynamics in x-ray cavities, offering new avenues for integrating quantum optical effects with x-ray spectroscopy.
- Open Access
- 21 January 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1) , 76
TRIXS: a multilayer grating solution towards highly efficient resonant inelastic tender X-ray scattering
Resonant inelastic X-ray scattering (RIXS) is a photon-in/photon-out spectroscopic technique which has become increasingly important for the condensed matter physics community. The development of the RIXS instrumentation in soft X-ray and hard X-ray range facilitated the research in 3 d and 5 d transition metal (TM)-based materials, respectively. However, the tender X-ray (2000–3000 eV) RIXS covering most of 4 d TM-based materials severely falls behind due to the lack of high-performance energy dispersive optics. Here, we demonstrate the design and fabrication of a laterally graded multilayer grating (MLG) optics for the establishment of the tender RIXS at the I21 RIXS beamline in Diamond Light Source. The successful implementation of the MLG boosts the photon flux by more than an order of magnitude at the Sulfur K -edge (2475 eV) and the Ru L 3 -edge (2838 eV) in comparison to the solution of a single-layer coated grating (SLG). More importantly, MLG retains the high energy resolution of the SLG design (~10,000) and works continuously across the full range of 2000–3000 eV. It renders the I21 beamline as the very first RIXS facility in the world that covers both soft and tender X-rays (280–3000 eV) using a grating-based spectrometer for a wide range of science applications.
- 21 January 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1) , 76
Open AccessTRIXS: a multilayer grating solution towards highly efficient resonant inelastic tender X-ray scattering
Resonant inelastic X-ray scattering (RIXS) is a photon-in/photon-out spectroscopic technique which has become increasingly important for the condensed matter physics community. The development of the RIXS instrumentation in soft X-ray and hard X-ray range facilitated the research in 3 d and 5 d transition metal (TM)-based materials, respectively. However, the tender X-ray (2000–3000 eV) RIXS covering most of 4 d TM-based materials severely falls behind due to the lack of high-performance energy dispersive optics. Here, we demonstrate the design and fabrication of a laterally graded multilayer grating (MLG) optics for the establishment of the tender RIXS at the I21 RIXS beamline in Diamond Light Source. The successful implementation of the MLG boosts the photon flux by more than an order of magnitude at the Sulfur K -edge (2475 eV) and the Ru L 3 -edge (2838 eV) in comparison to the solution of a single-layer coated grating (SLG). More importantly, MLG retains the high energy resolution of the SLG design (~10,000) and works continuously across the full range of 2000–3000 eV. It renders the I21 beamline as the very first RIXS facility in the world that covers both soft and tender X-rays (280–3000 eV) using a grating-based spectrometer for a wide range of science applications.
- Open Access
- 9 January 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (8)
Development of Laterally Graded X‐Ray Multilayer Optics
Laterally graded multilayer optics play an important role in advanced X‐ray applications, enabling precise control of beam properties for spectroscopic and focusing techniques. The Multilayer Deposition System (MDS) at Diamond Light Source (DLS) has demonstrated its ability to fabricate highly precise laterally graded X‐ray optics. Developing such optics is challenging due to stringent requirements for precise lateral thickness variations and sagittal uniformity, achieved through optimized substrate speed profiles and advanced mask design. This study presents a comprehensive investigation into the design, fabrication, and characterization of laterally graded multilayers. An adjustable mask design improves sagittal uniformity and reduces optimization times. The structural and optical performance of the multilayers is evaluated, confirming their suitability for synchrotron applications. Two types of laterally graded multilayers were developed: one with a constant lateral gradient (0.005 nm/mm) for O‐K edge polarizers, achieving sagittal thickness variations of approximately 0.3–0.4% across an 80 mm substrate, and another featuring a strong variable gradient from 0.037 to 0.112 nm/mm, designed to match the elliptical periodicity profile. The constant gradient multilayer polarizer has been successfully implemented on the state‐of‐the‐art I21 beamline at DLS, highlighting the MDS's role in producing next‐generation X‐ray optics that meet the stringent demands of synchrotron beamlines.
- 9 January 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (8)
Open AccessDevelopment of Laterally Graded X‐Ray Multilayer Optics
Laterally graded multilayer optics play an important role in advanced X‐ray applications, enabling precise control of beam properties for spectroscopic and focusing techniques. The Multilayer Deposition System (MDS) at Diamond Light Source (DLS) has demonstrated its ability to fabricate highly precise laterally graded X‐ray optics. Developing such optics is challenging due to stringent requirements for precise lateral thickness variations and sagittal uniformity, achieved through optimized substrate speed profiles and advanced mask design. This study presents a comprehensive investigation into the design, fabrication, and characterization of laterally graded multilayers. An adjustable mask design improves sagittal uniformity and reduces optimization times. The structural and optical performance of the multilayers is evaluated, confirming their suitability for synchrotron applications. Two types of laterally graded multilayers were developed: one with a constant lateral gradient (0.005 nm/mm) for O‐K edge polarizers, achieving sagittal thickness variations of approximately 0.3–0.4% across an 80 mm substrate, and another featuring a strong variable gradient from 0.037 to 0.112 nm/mm, designed to match the elliptical periodicity profile. The constant gradient multilayer polarizer has been successfully implemented on the state‐of‐the‐art I21 beamline at DLS, highlighting the MDS's role in producing next‐generation X‐ray optics that meet the stringent demands of synchrotron beamlines.
- Open Access
- 13 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 35698
High-efficiency multilayer grating for enhanced tender x-ray photoelectron spectroscopy
X-ray Photoelectron Spectroscopy (XPS) is a powerful tool for probing the chemical and electronic states of materials with elemental specificity and surface sensitivity. However, its application in the tender X-ray range (1–5 keV) for synchrotron radiation has remained limited due to the limited choice of optics capable of maintaining high reflectivity and efficiency in this energy window. To address this, multilayer (ML) grating structures have become increasingly popular, offering significantly higher efficiency than SL coatings in the tender X-ray region. This paper presents the development of ML laminar gratings optimised for enhancing efficiency in the tender X-ray range, and capable of retaining performance under intense X-ray exposure in the oxygen partial pressure of $$\sim$$ 10 $$^{-8}$$ mbar. The ML coating quality was verified through X-ray reflectivity (XRR), XPS and near-edge X-ray absorption fine structures (NEXAFS) measurements, while the performance of the grating was validated through beamline flux transmission and XPS measurements. The MLLG demonstrated $$\sim$$ 22 $$\times$$ higher intensity in flux and XPS, significantly improving the signal-to-noise ratio. Most importantly, the MLLGs outperformed traditional designs by offering improved spectral resolution while maintaining measurement capability at varying $$C_{ff}$$ values without compromising the intensity. Furthermore, we demonstrated that the incorporation of nitrogen during deposition further enhances flux transmission.- 13 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 35698
Open AccessHigh-efficiency multilayer grating for enhanced tender x-ray photoelectron spectroscopy
X-ray Photoelectron Spectroscopy (XPS) is a powerful tool for probing the chemical and electronic states of materials with elemental specificity and surface sensitivity. However, its application in the tender X-ray range (1–5 keV) for synchrotron radiation has remained limited due to the limited choice of optics capable of maintaining high reflectivity and efficiency in this energy window. To address this, multilayer (ML) grating structures have become increasingly popular, offering significantly higher efficiency than SL coatings in the tender X-ray region. This paper presents the development of ML laminar gratings optimised for enhancing efficiency in the tender X-ray range, and capable of retaining performance under intense X-ray exposure in the oxygen partial pressure of $$\sim$$ 10 $$^{-8}$$ mbar. The ML coating quality was verified through X-ray reflectivity (XRR), XPS and near-edge X-ray absorption fine structures (NEXAFS) measurements, while the performance of the grating was validated through beamline flux transmission and XPS measurements. The MLLG demonstrated $$\sim$$ 22 $$\times$$ higher intensity in flux and XPS, significantly improving the signal-to-noise ratio. Most importantly, the MLLGs outperformed traditional designs by offering improved spectral resolution while maintaining measurement capability at varying $$C_{ff}$$ values without compromising the intensity. Furthermore, we demonstrated that the incorporation of nitrogen during deposition further enhances flux transmission. - 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
A new, ultra-stable lab for nano-metrology of x-ray optics at Diamond Light Source
A new Optics Metrology Laboratory for assembling and characterizing beamline x-ray optical systems has been built. This replaces the old laboratory, which was demolished to make space for construction of a new flagship beamline for the forthcoming Diamond-II facility upgrade. The new cleanroom laboratory is located between several beamlines and laboratories, which intermittently generate significantly higher levels of acoustic noise and floor vibrations. A threefold design strategy was employed to create an ultra-stable environment for the sensitive, optical metrology instruments. First, the walls, ceiling and doors of the laboratory were constructed to attenuate acoustic noise. Second, the air handling systems were designed to minimize self-production of noise and vibrations. Finally, engineering solutions were developed to further isolate the metrology instruments from environmental fluctuations. Overall, despite higher levels of external disturbances, this strategy enables nano-metrology to be successfully conducted in the new laboratory. The shielded environment around each instrument achieves noise rating NR30, which is 5–25 dB quieter than the old laboratory. Over 60-h, the temperature inside the Diamond-NOM’s enclosure varied by only 0.004 °C rms, and humidity changed by <1% RH. All optical metrology instruments are now performing better than in the old laboratory: the slope error repeatability of Diamond-NOM is improved from 15 to 9 nrad rms; the GTX micro-interferometer has measured super-polished substrates with micro-roughness <40 pm rms; the new gantry for Speckle Angular Measurement is commissioned; and the HDX Fizeau interferometer has measured mirrors with slope errors <50 nrad.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
A new, ultra-stable lab for nano-metrology of x-ray optics at Diamond Light Source
A new Optics Metrology Laboratory for assembling and characterizing beamline x-ray optical systems has been built. This replaces the old laboratory, which was demolished to make space for construction of a new flagship beamline for the forthcoming Diamond-II facility upgrade. The new cleanroom laboratory is located between several beamlines and laboratories, which intermittently generate significantly higher levels of acoustic noise and floor vibrations. A threefold design strategy was employed to create an ultra-stable environment for the sensitive, optical metrology instruments. First, the walls, ceiling and doors of the laboratory were constructed to attenuate acoustic noise. Second, the air handling systems were designed to minimize self-production of noise and vibrations. Finally, engineering solutions were developed to further isolate the metrology instruments from environmental fluctuations. Overall, despite higher levels of external disturbances, this strategy enables nano-metrology to be successfully conducted in the new laboratory. The shielded environment around each instrument achieves noise rating NR30, which is 5–25 dB quieter than the old laboratory. Over 60-h, the temperature inside the Diamond-NOM’s enclosure varied by only 0.004 °C rms, and humidity changed by <1% RH. All optical metrology instruments are now performing better than in the old laboratory: the slope error repeatability of Diamond-NOM is improved from 15 to 9 nrad rms; the GTX micro-interferometer has measured super-polished substrates with micro-roughness <40 pm rms; the new gantry for Speckle Angular Measurement is commissioned; and the HDX Fizeau interferometer has measured mirrors with slope errors <50 nrad.
- Open Access
- 7 August 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (9)
Development of High‐Performance Multilayer Monochromators
Multilayer monochromators are crucial optical elements for monochromatizing intense X‐ray beams in applications demanding high photon flux with moderate energy resolution. Achieving high‐performance multilayer monochromators requires optimizing multilayer parameters, using high‐quality substrates, and precisely controlling the deposition process to ensure high reflectivity and eliminate stripe artifacts. This paper presents the design and development, and characterization of double multilayer monochromators (DMM). These coatings are deposited using an optimized mask design to ensure 2 ) ‐ to enhance multilayer reflectivity. A high reflectivity of 88.7% at 14.0 keV and 85.6% at 22.4 keV is achieved. Furthermore, stripe‐free imaging is achieved in double‐reflection geometry via the use of high‐quality substrates produced using the in‐house ion beam figuring machine. These findings offer valuable insights for developing high‐performance DMMs, paving the way for the next generation of synchrotron optics and instruments.
- 7 August 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (9)
Open AccessDevelopment of High‐Performance Multilayer Monochromators
Multilayer monochromators are crucial optical elements for monochromatizing intense X‐ray beams in applications demanding high photon flux with moderate energy resolution. Achieving high‐performance multilayer monochromators requires optimizing multilayer parameters, using high‐quality substrates, and precisely controlling the deposition process to ensure high reflectivity and eliminate stripe artifacts. This paper presents the design and development, and characterization of double multilayer monochromators (DMM). These coatings are deposited using an optimized mask design to ensure 2 ) ‐ to enhance multilayer reflectivity. A high reflectivity of 88.7% at 14.0 keV and 85.6% at 22.4 keV is achieved. Furthermore, stripe‐free imaging is achieved in double‐reflection geometry via the use of high‐quality substrates produced using the in‐house ion beam figuring machine. These findings offer valuable insights for developing high‐performance DMMs, paving the way for the next generation of synchrotron optics and instruments.
- Open Access
- 1 January 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (1) , 261-268
PGMweb: an online tool for visualizing the X-ray beam path through plane grating monochromators
We present here a newly developed software tool (called PGMweb) for computing and simulating the X-ray beam path through a plane grating monochromator (PGM), a key component in soft X-ray beamlines at modern synchrotron and free-electron laser facilities. A historical overview of the development of PGMs is presented, with special attention dedicated to the collimated PGM optical scheme found at several X-ray facilities worldwide. The analytical expressions that fully describe the geometry of a PGM are derived and have been implemented as functions in a Python library (pyplanemono). PGMweb is distributed as a web-based application that can be run in any modern browser without installation, making its use very straightforward for X-ray beamline designers and beamline scientists alike.
- 1 January 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (1) , 261-268
Open AccessPGMweb: an online tool for visualizing the X-ray beam path through plane grating monochromators
We present here a newly developed software tool (called PGMweb) for computing and simulating the X-ray beam path through a plane grating monochromator (PGM), a key component in soft X-ray beamlines at modern synchrotron and free-electron laser facilities. A historical overview of the development of PGMs is presented, with special attention dedicated to the collimated PGM optical scheme found at several X-ray facilities worldwide. The analytical expressions that fully describe the geometry of a PGM are derived and have been implemented as functions in a Python library (pyplanemono). PGMweb is distributed as a web-based application that can be run in any modern browser without installation, making its use very straightforward for X-ray beamline designers and beamline scientists alike.
- Open Access
- 28 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1457-1463
A study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates
Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.
- 28 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1457-1463
Open AccessA study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates
Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.