Steven M. Stufflebeam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steven M. Stufflebeam has a total of 155 co-authors. Here are the top co-authors by number of shared publications:
- Teppei Matsubara
Massachusetts General Hospital
4 shared publications - Jyrki Ahveninen
Department of Radiology, Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
3 shared publications - Robert Mark Richardson
Department of Neurosurgery, Mass General Brigham and Harvard Medical School, Boston, MA, USA
3 shared publications - Christos Papadelis
Neuroscience Research Center, Jane and John Justin Institute for Mind Health, Cook Children’s Health Care System, Fort Worth, USA
2 shared publications Fahimeh Mamashli
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
2 shared publicationsJoseph R. Madsen
Division of Epilepsy Surgery, Department of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
2 shared publications
Latest Publications
- Open Access
A Patient-Specific Framework for Separating Temporal Localization from Intracranial Waveform Reconstruction of Interictal Epileptiform Discharges from Scalp EEG
Objective: We developed a patient-specific framework to determine which information about interictal epileptiform discharges (IEDs) can be recovered from scalp EEG, separating temporal localization (“where”) from event-specific intracranial waveform reconstruction (“what”). Methods: Six subjects from a public simultaneous high-density scalp EEG and intracranial EEG (iEEG) dataset were analyzed using patient-specific dual-branch convolutional-attention models integrating waveform/topographic and time-frequency representations. For the where task, a 640-ms scalp EEG segment was divided into eight 80-ms bins, and the model predicted the bin containing the intracranial IED peak. For the what task, a 250-ms peak-centered iEEG waveform was represented as a fixed patient-specific template plus an event-specific residual predicted from scalp EEG. Direct scalp-input controls and event-clustered bootstrap confidence intervals were used to distinguish scalp-dependent information from template-driven performance. Results: Where accuracy varied markedly across subjects (0.080–0.984), with an unweighted subject-level mean of 0.333 versus a chance level of 0.125; 95% confidence intervals were above chance level in three of six subjects. Input-control analyses supported a scalp-dependent contribution in subjects with successful localization. For the what task, mean waveform correlation was 0.752 for the model and 0.754 for the fixed patient-specific template (mean difference,-0.002), while residual correlations were generally modest (−0.020 to 0.378). Conclusion: Scalp EEG contained recoverable temporal information in some subjects, but event-specific single-contact morphology was not consistently recovered beyond the patient-specific template. Separating temporal localization from template-based waveform reconstruction provides a more stringent framework for evaluating noninvasive-to-intracranial inference and reduces conflation of prior-driven similarity with input-dependent reconstruction.
Open AccessA Patient-Specific Framework for Separating Temporal Localization from Intracranial Waveform Reconstruction of Interictal Epileptiform Discharges from Scalp EEG
Objective: We developed a patient-specific framework to determine which information about interictal epileptiform discharges (IEDs) can be recovered from scalp EEG, separating temporal localization (“where”) from event-specific intracranial waveform reconstruction (“what”). Methods: Six subjects from a public simultaneous high-density scalp EEG and intracranial EEG (iEEG) dataset were analyzed using patient-specific dual-branch convolutional-attention models integrating waveform/topographic and time-frequency representations. For the where task, a 640-ms scalp EEG segment was divided into eight 80-ms bins, and the model predicted the bin containing the intracranial IED peak. For the what task, a 250-ms peak-centered iEEG waveform was represented as a fixed patient-specific template plus an event-specific residual predicted from scalp EEG. Direct scalp-input controls and event-clustered bootstrap confidence intervals were used to distinguish scalp-dependent information from template-driven performance. Results: Where accuracy varied markedly across subjects (0.080–0.984), with an unweighted subject-level mean of 0.333 versus a chance level of 0.125; 95% confidence intervals were above chance level in three of six subjects. Input-control analyses supported a scalp-dependent contribution in subjects with successful localization. For the what task, mean waveform correlation was 0.752 for the model and 0.754 for the fixed patient-specific template (mean difference,-0.002), while residual correlations were generally modest (−0.020 to 0.378). Conclusion: Scalp EEG contained recoverable temporal information in some subjects, but event-specific single-contact morphology was not consistently recovered beyond the patient-specific template. Separating temporal localization from template-based waveform reconstruction provides a more stringent framework for evaluating noninvasive-to-intracranial inference and reduces conflation of prior-driven similarity with input-dependent reconstruction.
- Open Access
Motion tolerance in wearable OPM-MEG using dynamic field nulling
Wearable magnetoencephalography (MEG) enabled by optically pumped magnetometers (OPMs) promises improved comfort and motion tolerance. This is particularly beneficial when measuring brain activity in children who cannot sit still for long periods of time. Compared to cryogenic MEG, wearable MEG allows larger head movements, but they result in artifacts due to uncompensated background fields and reduce source localization accuracy. Spatial filtering methods can partially compensate these motion-induced artifacts, but they are most effective when used in combination with background field nulling. This is because accurate spatial filtering relies on an accurate estimate of the sensor gain and orientation of its sensitive axis. Through simulations, we first deduce the target residual background field that is necessary for accurate dipole localization (< 1 cm) in the presence of head movements. Our simulations indicate that smaller background fields enable larger head movements. Then, we used our open-source printed circuit board (PCB) coils to develop a method to dynamically null the background field. We demonstrate that our dynamic field nulling method allows improved localization of somatosensory evoked fields (SEFs) by maintaining the background field below the target residual fields established in the simulations. Our study highlights the importance of tracking both the background field and the head position relative to the background field for quality assurance in wearable MEG.
Open AccessMotion tolerance in wearable OPM-MEG using dynamic field nulling
Wearable magnetoencephalography (MEG) enabled by optically pumped magnetometers (OPMs) promises improved comfort and motion tolerance. This is particularly beneficial when measuring brain activity in children who cannot sit still for long periods of time. Compared to cryogenic MEG, wearable MEG allows larger head movements, but they result in artifacts due to uncompensated background fields and reduce source localization accuracy. Spatial filtering methods can partially compensate these motion-induced artifacts, but they are most effective when used in combination with background field nulling. This is because accurate spatial filtering relies on an accurate estimate of the sensor gain and orientation of its sensitive axis. Through simulations, we first deduce the target residual background field that is necessary for accurate dipole localization (< 1 cm) in the presence of head movements. Our simulations indicate that smaller background fields enable larger head movements. Then, we used our open-source printed circuit board (PCB) coils to develop a method to dynamically null the background field. We demonstrate that our dynamic field nulling method allows improved localization of somatosensory evoked fields (SEFs) by maintaining the background field below the target residual fields established in the simulations. Our study highlights the importance of tracking both the background field and the head position relative to the background field for quality assurance in wearable MEG.
- Open Access
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Objective: Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly used generalized MEG-only models, whereas clinical MEG interpretation routinely integrates simultaneous electroencephalography (EEG) and includes MEG-unique or MEG-dominant discharges. We developed a patient-specific EEG-MEG IED detector and evaluated event-wise prediction stability across models and the effect of adding EEG to MEG-based prediction. Methods: Seventeen patients undergoing clinical EEG-MEG evaluation for epilepsy were retrospectively analyzed. Clinically accepted dipole-review IEDs were treated as positive events, and nonannotated events were sampled as negatives. Logistic regression (LR), random forest (RF), and a lightweight three-dimensional ResNet were trained separately within each patient using EEG-only, MEG-only, and combined EEG-MEG (EMEG) inputs. Primary performance metrics were the area under the receiver operating characteristic curve (ROC-AUC) and average precision. Event-wise stability was assessed using rank disagreement, rank volatility, and class-aware distribution quotient analysis. Results: Aggregate discrimination was high across models and modalities. Median ROC-AUCs for EEG, MEG, and EMEG were 0.850, 0.890, and 0.880 for LR; 0.880, 0.860, and 0.910 for RF; and 0.920, 0.960, and 0.960 for ResNet. Despite comparable aggregate performance, event-wise analysis revealed model-dependent prediction behavior. ResNet showed significantly lower non-IED rank volatility than classical machine learning models and lower non-IED rank disagreement, particularly compared with RF. Adding EEG to MEG was associated with more favorable class-aware event-wise positioning in most events, while MEG-unique/dominant cases showed greater relative MEG contribution. Conclusions: Patient-specific EEG-MEG IED detection revealed clinically meaningful event-wise differences not captured by aggregate metrics. Simultaneous EEG complemented MEG-based detection, while MEG contribution remained prominent in MEG-dominant cases, supporting multimodal patient-specific IED event prioritization.
Open AccessEvent-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Objective: Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly used generalized MEG-only models, whereas clinical MEG interpretation routinely integrates simultaneous electroencephalography (EEG) and includes MEG-unique or MEG-dominant discharges. We developed a patient-specific EEG-MEG IED detector and evaluated event-wise prediction stability across models and the effect of adding EEG to MEG-based prediction. Methods: Seventeen patients undergoing clinical EEG-MEG evaluation for epilepsy were retrospectively analyzed. Clinically accepted dipole-review IEDs were treated as positive events, and nonannotated events were sampled as negatives. Logistic regression (LR), random forest (RF), and a lightweight three-dimensional ResNet were trained separately within each patient using EEG-only, MEG-only, and combined EEG-MEG (EMEG) inputs. Primary performance metrics were the area under the receiver operating characteristic curve (ROC-AUC) and average precision. Event-wise stability was assessed using rank disagreement, rank volatility, and class-aware distribution quotient analysis. Results: Aggregate discrimination was high across models and modalities. Median ROC-AUCs for EEG, MEG, and EMEG were 0.850, 0.890, and 0.880 for LR; 0.880, 0.860, and 0.910 for RF; and 0.920, 0.960, and 0.960 for ResNet. Despite comparable aggregate performance, event-wise analysis revealed model-dependent prediction behavior. ResNet showed significantly lower non-IED rank volatility than classical machine learning models and lower non-IED rank disagreement, particularly compared with RF. Adding EEG to MEG was associated with more favorable class-aware event-wise positioning in most events, while MEG-unique/dominant cases showed greater relative MEG contribution. Conclusions: Patient-specific EEG-MEG IED detection revealed clinically meaningful event-wise differences not captured by aggregate metrics. Simultaneous EEG complemented MEG-based detection, while MEG contribution remained prominent in MEG-dominant cases, supporting multimodal patient-specific IED event prioritization.
- Open Access
Quantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling
Objective: The cerebellum is increasingly recognized as a key component of large-scale brain networks implicated in epilepsy, yet its electrophysiological characterization remains limited in noninvasive recordings. This limitation arises from the cerebellum's depth, complex folding, and unfavorable source orientations, which challenge conventional magnetoencephalography (MEG) and electroencephalography (EEG). Here, we quantitatively characterize cerebellar signal detectability across modalities and sensor configurations using anatomically informed source modeling at the population level. Methods: We analyzed clinical MEG and EEG recordings from a large cohort of patients with epilepsy undergoing presurgical evaluation. Cerebellar and cerebral source spaces were constructed using subject-specific anatomical models derived from routine clinical MRI, enabling consistent forward modeling across individuals. Signal-to-noise ratio (SNR) was estimated at individual source locations and summarized at the regional level. In addition to clinical Superconducting quantum interference device (SQUID)-MEG and EEG, multiple on-scalp optically pumped magnetometer (OPM) configurations were evaluated through simulation, including layouts matched to clinical sensor geometries and layouts optimized for posterior fossa coverage. The effects of source orientation, sensor-source distance, and head size on SNR were systematically investigated. Results: In routine clinical recordings, cerebellar SNR was consistently lower than superficial cortical reference levels, confirming the limited detectability of cerebellar activity with standard SQUID-MEG and EEG. Reducing sensor-source distance by placing OPMs at SQUID-equivalent locations, i.e., projecting SQUID sensor locations to the scalp, did not improve cerebellar SNR, indicating that proximity alone is insufficient for better detectability of deeper sources. In contrast, cerebellar-optimized OPM layouts produced substantial SNR gains in posterior cerebellar regions. The effects of source orientation influence SNR differences between OPM and EEG (under identical sensor/electrode coverage) but were secondary to depth- and geometry-related constraints. Mediation analysis further demonstrated that relative sensor distance significantly mediated OPM-related advantages in posterior cerebellar regions, particularly in individuals with smaller head sizes. Conclusions: These findings demonstrate that cerebellar signal detectability is governed primarily by anatomical depth and geometry rather than sensor proximity alone. Anatomically informed source modeling, combined with flexible and region-specific sensor layouts, enables meaningful improvements in cerebellar SNR that are not achievable with fixed-helmet systems. While directly motivated by epilepsy, this framework advances human brain mapping beyond the cerebrum by providing a principled approach for evaluating MEG and EEG sensitivity in deep and highly folded brain structures.
Open AccessQuantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling
Objective: The cerebellum is increasingly recognized as a key component of large-scale brain networks implicated in epilepsy, yet its electrophysiological characterization remains limited in noninvasive recordings. This limitation arises from the cerebellum's depth, complex folding, and unfavorable source orientations, which challenge conventional magnetoencephalography (MEG) and electroencephalography (EEG). Here, we quantitatively characterize cerebellar signal detectability across modalities and sensor configurations using anatomically informed source modeling at the population level. Methods: We analyzed clinical MEG and EEG recordings from a large cohort of patients with epilepsy undergoing presurgical evaluation. Cerebellar and cerebral source spaces were constructed using subject-specific anatomical models derived from routine clinical MRI, enabling consistent forward modeling across individuals. Signal-to-noise ratio (SNR) was estimated at individual source locations and summarized at the regional level. In addition to clinical Superconducting quantum interference device (SQUID)-MEG and EEG, multiple on-scalp optically pumped magnetometer (OPM) configurations were evaluated through simulation, including layouts matched to clinical sensor geometries and layouts optimized for posterior fossa coverage. The effects of source orientation, sensor-source distance, and head size on SNR were systematically investigated. Results: In routine clinical recordings, cerebellar SNR was consistently lower than superficial cortical reference levels, confirming the limited detectability of cerebellar activity with standard SQUID-MEG and EEG. Reducing sensor-source distance by placing OPMs at SQUID-equivalent locations, i.e., projecting SQUID sensor locations to the scalp, did not improve cerebellar SNR, indicating that proximity alone is insufficient for better detectability of deeper sources. In contrast, cerebellar-optimized OPM layouts produced substantial SNR gains in posterior cerebellar regions. The effects of source orientation influence SNR differences between OPM and EEG (under identical sensor/electrode coverage) but were secondary to depth- and geometry-related constraints. Mediation analysis further demonstrated that relative sensor distance significantly mediated OPM-related advantages in posterior cerebellar regions, particularly in individuals with smaller head sizes. Conclusions: These findings demonstrate that cerebellar signal detectability is governed primarily by anatomical depth and geometry rather than sensor proximity alone. Anatomically informed source modeling, combined with flexible and region-specific sensor layouts, enables meaningful improvements in cerebellar SNR that are not achievable with fixed-helmet systems. While directly motivated by epilepsy, this framework advances human brain mapping beyond the cerebrum by providing a principled approach for evaluating MEG and EEG sensitivity in deep and highly folded brain structures.
- Open Access
- 24 December 2025
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Transcriptomic decoding of regional cortical vulnerability to drug-resistant epilepsy using 7T MRI
The mechanism by which genetic risk leads to cortical vulnerability in drug-resistant epilepsy (DRE) remains unclear. This study used 7T structural and resting-state functional MRI to investigate cortical neural activity alterations in 105 DRE patients and 105 healthy controls (HCs), and to explore related genetic mechanisms. Vertex-wise analyses of mean amplitude of low-frequency fluctuation (mALFF) and regional homogeneity (ReHo) revealed that DRE patients primarily exhibited decreased mALFF and increased ReHo in the Cingulo-Opercular Network. Using the Allen Human Brain Atlas, we conducted spatial transcriptomic analysis via partial least squares (PLS) and gene enrichment analysis to identify gene categories associated with these functional changes. The results showed that cortical alterations were related to epilepsy-general genes (e.g., TMEM74, KCNN2, RBFOX1) and brain-relevant genes. Genes positively correlated with mALFF alterations enriched in mitochondrial inner membrane, matrix, and carboxylic acid metabolism; negatively in chromatin remodeling, binding, and postsynapse. Genes positively correlated with ReHo alterations enriched in nucleic acid-related catalytic activity, ribonucleoprotein granule, and centrosome; negatively in amyotrophic lateral sclerosis, mitochondrial membrane, and pyrophosphatase activity. These findings link spatial brain activity abnormalities in DRE to specific genetic signatures and biological pathways, suggesting new mechanistic insights and potential therapeutic targets for this difficult-to-treat condition.
- 24 December 2025
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Open AccessTranscriptomic decoding of regional cortical vulnerability to drug-resistant epilepsy using 7T MRI
The mechanism by which genetic risk leads to cortical vulnerability in drug-resistant epilepsy (DRE) remains unclear. This study used 7T structural and resting-state functional MRI to investigate cortical neural activity alterations in 105 DRE patients and 105 healthy controls (HCs), and to explore related genetic mechanisms. Vertex-wise analyses of mean amplitude of low-frequency fluctuation (mALFF) and regional homogeneity (ReHo) revealed that DRE patients primarily exhibited decreased mALFF and increased ReHo in the Cingulo-Opercular Network. Using the Allen Human Brain Atlas, we conducted spatial transcriptomic analysis via partial least squares (PLS) and gene enrichment analysis to identify gene categories associated with these functional changes. The results showed that cortical alterations were related to epilepsy-general genes (e.g., TMEM74, KCNN2, RBFOX1) and brain-relevant genes. Genes positively correlated with mALFF alterations enriched in mitochondrial inner membrane, matrix, and carboxylic acid metabolism; negatively in chromatin remodeling, binding, and postsynapse. Genes positively correlated with ReHo alterations enriched in nucleic acid-related catalytic activity, ribonucleoprotein granule, and centrosome; negatively in amyotrophic lateral sclerosis, mitochondrial membrane, and pyrophosphatase activity. These findings link spatial brain activity abnormalities in DRE to specific genetic signatures and biological pathways, suggesting new mechanistic insights and potential therapeutic targets for this difficult-to-treat condition.
- Open Access
Evidence for a role of skull bone marrow in human chronic pain
The skull bone marrow is emerging as a critical hub for neuroimmune signaling, yet its role in chronic pain is unknown. Using integrated positron emission tomography / magnetic resonance imaging, here we show that the levels of 18 kDa translocator (TSPO), a marker of immune cell density, is elevated in the skull bone marrow of individuals with chronic pain (N=125; chronic low back pain [cLBP], N=88; knee osteoarthritis [KOA], N=37), compared to healthy controls (N=22). These elevations were widespread, generally more pronounced for KOA than cLBP, and associated with greater pain intensity, pain interference, depression, and anxiety (all p < 0.001). Because TSPO is highly expressed in myeloid cells, these results associate skull bone marrow immune dysregulation with chronic pain and its associated psychological and functional impairments. These findings provide a strong rationale for investigating this previously overlooked structure, which remains largely underexplored in the context of pain.
Open AccessEvidence for a role of skull bone marrow in human chronic pain
The skull bone marrow is emerging as a critical hub for neuroimmune signaling, yet its role in chronic pain is unknown. Using integrated positron emission tomography / magnetic resonance imaging, here we show that the levels of 18 kDa translocator (TSPO), a marker of immune cell density, is elevated in the skull bone marrow of individuals with chronic pain (N=125; chronic low back pain [cLBP], N=88; knee osteoarthritis [KOA], N=37), compared to healthy controls (N=22). These elevations were widespread, generally more pronounced for KOA than cLBP, and associated with greater pain intensity, pain interference, depression, and anxiety (all p < 0.001). Because TSPO is highly expressed in myeloid cells, these results associate skull bone marrow immune dysregulation with chronic pain and its associated psychological and functional impairments. These findings provide a strong rationale for investigating this previously overlooked structure, which remains largely underexplored in the context of pain.
- 7 January 2025
- Published by Springer Nature in Neurocritical Care
- Vol. 42 (3) , 1025-1042
Diagnostic Accuracy of S100B in Predicting Intracranial Abnormalities on CT Imaging Following Mild Traumatic Brain Injury: A Systematic Review and Meta-analysis
Traumatic brain injury (TBI) is a major cause of health loss and disabilities globally, burdening health care systems. Mild TBI is a common cause of emergency department visits. Computed tomography (CT) scans are the mainstay for acute TBI imaging. S100 calcium-binding protein B (S100B) biomarker is promising for predicting intracranial lesions on CTs in mild TBI. A comprehensive search of the literature was conducted on PubMed, Google Scholar, and Cochrane electronic databases to find eligible studies reporting the diagnostic performance of S100B. A meta-analysis was conducted to evaluate the predictive ability of S100B for CT imaging abnormalities. Of 1545 articles, 32 were included in our meta-analysis. At the threshold of 0.1 μg/L, a bivariate model showed a sensitivity of 89% (95% confidence interval [CI] 83–92) with a specificity of 32% (95% CI 26–39). The aggregate analysis containing all cutoffs showed the optimal cutoff of 0.751 μg/L with a sensitivity of 64% (95% CI 32–87) and a specificity of 85% (95% CI 76–92). The optimal diagnostic performance of S100B in patients with Glasgow Coma Scale 14–15 was estimated to be 0.05 μg/L, with a sensitivity of 98% (95% CI 92–99) and a negative predictive value of 99%. These findings indicate that S100B analysis could minimize the need for unnecessary CT scans in individuals with mild TBI. The test’s diagnostic accuracy improves when the S100B analysis is done within 3 h of the injury. However, further research is warranted to validate its superiority to other biomarkers before considering it the standard routine for managing mild TBI.
- 7 January 2025
- Published by Springer Nature in Neurocritical Care
- Vol. 42 (3) , 1025-1042
Diagnostic Accuracy of S100B in Predicting Intracranial Abnormalities on CT Imaging Following Mild Traumatic Brain Injury: A Systematic Review and Meta-analysis
Traumatic brain injury (TBI) is a major cause of health loss and disabilities globally, burdening health care systems. Mild TBI is a common cause of emergency department visits. Computed tomography (CT) scans are the mainstay for acute TBI imaging. S100 calcium-binding protein B (S100B) biomarker is promising for predicting intracranial lesions on CTs in mild TBI. A comprehensive search of the literature was conducted on PubMed, Google Scholar, and Cochrane electronic databases to find eligible studies reporting the diagnostic performance of S100B. A meta-analysis was conducted to evaluate the predictive ability of S100B for CT imaging abnormalities. Of 1545 articles, 32 were included in our meta-analysis. At the threshold of 0.1 μg/L, a bivariate model showed a sensitivity of 89% (95% confidence interval [CI] 83–92) with a specificity of 32% (95% CI 26–39). The aggregate analysis containing all cutoffs showed the optimal cutoff of 0.751 μg/L with a sensitivity of 64% (95% CI 32–87) and a specificity of 85% (95% CI 76–92). The optimal diagnostic performance of S100B in patients with Glasgow Coma Scale 14–15 was estimated to be 0.05 μg/L, with a sensitivity of 98% (95% CI 92–99) and a negative predictive value of 99%. These findings indicate that S100B analysis could minimize the need for unnecessary CT scans in individuals with mild TBI. The test’s diagnostic accuracy improves when the S100B analysis is done within 3 h of the injury. However, further research is warranted to validate its superiority to other biomarkers before considering it the standard routine for managing mild TBI.
- Open Access
- 6 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 897
Improved Dipole Source Localization from Simultaneous MEG-EEG Data by Combining a Global Optimization Algorithm with a Local Parameter Search: A Brain Phantom Study
Dipole localization, a fundamental challenge in electromagnetic source imaging, inherently constitutes an optimization problem aimed at solving the inverse problem of electric current source estimation within the human brain. The accuracy of dipole localization algorithms is contingent upon the complexity of the forward model, often referred to as the head model, and the signal-to-noise ratio (SNR) of measurements. In scenarios characterized by low SNR, often corresponding to deep-seated sources, existing optimization techniques struggle to converge to global minima, thereby leading to the localization of dipoles at erroneous positions, far from their true locations. This study presents a novel hybrid algorithm that combines simulated annealing with the traditional quasi-Newton optimization method, tailored to address the inherent limitations of dipole localization under low-SNR conditions. Using a realistic head model for both electroencephalography (EEG) and magnetoencephalography (MEG), it is demonstrated that this novel hybrid algorithm enables significant improvements of up to 45% in dipole localization accuracy compared to the often-used dipole scanning and gradient descent techniques. Localization improvements are not only found for single dipoles but also in two-dipole-source scenarios, where sources are proximal to each other. The novel methodology presented in this work could be useful in various applications of clinical neuroimaging, particularly in cases where recordings are noisy or sources are located deep within the brain.
- 6 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 897
Open AccessImproved Dipole Source Localization from Simultaneous MEG-EEG Data by Combining a Global Optimization Algorithm with a Local Parameter Search: A Brain Phantom Study
Dipole localization, a fundamental challenge in electromagnetic source imaging, inherently constitutes an optimization problem aimed at solving the inverse problem of electric current source estimation within the human brain. The accuracy of dipole localization algorithms is contingent upon the complexity of the forward model, often referred to as the head model, and the signal-to-noise ratio (SNR) of measurements. In scenarios characterized by low SNR, often corresponding to deep-seated sources, existing optimization techniques struggle to converge to global minima, thereby leading to the localization of dipoles at erroneous positions, far from their true locations. This study presents a novel hybrid algorithm that combines simulated annealing with the traditional quasi-Newton optimization method, tailored to address the inherent limitations of dipole localization under low-SNR conditions. Using a realistic head model for both electroencephalography (EEG) and magnetoencephalography (MEG), it is demonstrated that this novel hybrid algorithm enables significant improvements of up to 45% in dipole localization accuracy compared to the often-used dipole scanning and gradient descent techniques. Localization improvements are not only found for single dipoles but also in two-dipole-source scenarios, where sources are proximal to each other. The novel methodology presented in this work could be useful in various applications of clinical neuroimaging, particularly in cases where recordings are noisy or sources are located deep within the brain.
- Open Access
Human intracranial correlates of dynamic coding in auditory working memory
Working memory (WM), the human brain’s system for maintaining and manipulating information over short timescales, is critical for goal-directed behavior. Classic neurophysiological models, which emphasize persistent delay activity, are being challenged by an idea that WM is maintained through dynamic and activity-silent mechanisms, where the memory trace is preserved by transient changes in the connections between neurons. To date, human evidence for this alternative model has been limited to non-invasive studies. Here, leveraging high-resolution intracranial stereo-EEG with advanced machine learning decoding techniques, we investigate neuronal mechanisms of human auditory WM. Neuronal activity is quantified as broadband high frequency activity (70-190 Hz), a correlate of neuronal firing activity. Our multivariate pattern analyses, validated via robust non-parametric permutation testing, show that WM content is represented in multiple brain regions, exhibiting dynamic rather than persistent delay activity. Crucially, by using task-irrelevant sounds to probe latent mnemonic states, we provide the first human intracranial evidence of activity silent WM maintenance in a local sensory network.
Open AccessHuman intracranial correlates of dynamic coding in auditory working memory
Working memory (WM), the human brain’s system for maintaining and manipulating information over short timescales, is critical for goal-directed behavior. Classic neurophysiological models, which emphasize persistent delay activity, are being challenged by an idea that WM is maintained through dynamic and activity-silent mechanisms, where the memory trace is preserved by transient changes in the connections between neurons. To date, human evidence for this alternative model has been limited to non-invasive studies. Here, leveraging high-resolution intracranial stereo-EEG with advanced machine learning decoding techniques, we investigate neuronal mechanisms of human auditory WM. Neuronal activity is quantified as broadband high frequency activity (70-190 Hz), a correlate of neuronal firing activity. Our multivariate pattern analyses, validated via robust non-parametric permutation testing, show that WM content is represented in multiple brain regions, exhibiting dynamic rather than persistent delay activity. Crucially, by using task-irrelevant sounds to probe latent mnemonic states, we provide the first human intracranial evidence of activity silent WM maintenance in a local sensory network.
- Open Access
- 5 July 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 153, 88-101
Electromagnetic source imaging predicts surgical outcome in children with focal cortical dysplasia
- 5 July 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 153, 88-101
Open AccessElectromagnetic source imaging predicts surgical outcome in children with focal cortical dysplasia