Teppei Matsubara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Teppei Matsubara has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Steven M. Stufflebeam
Massachusetts General Hospital
4 shared publications - Abbas Sohrabpour
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
3 shared publications - Mainak Jas
Massachusetts General Hospital
3 shared publications - Padmavathi Sundaram
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
3 shared publications - Seppo P. Ahlfors
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
3 shared publications Steven Stufflebeam
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA; Harvard Medical School, Boston, MA, USA
3 shared publications
Latest Publications
- Open Access
A Patient-Specific Framework for Separating Temporal Localization from Intracranial Waveform Reconstruction of Interictal Epileptiform Discharges from Scalp EEG
Objective: We developed a patient-specific framework to determine which information about interictal epileptiform discharges (IEDs) can be recovered from scalp EEG, separating temporal localization (“where”) from event-specific intracranial waveform reconstruction (“what”). Methods: Six subjects from a public simultaneous high-density scalp EEG and intracranial EEG (iEEG) dataset were analyzed using patient-specific dual-branch convolutional-attention models integrating waveform/topographic and time-frequency representations. For the where task, a 640-ms scalp EEG segment was divided into eight 80-ms bins, and the model predicted the bin containing the intracranial IED peak. For the what task, a 250-ms peak-centered iEEG waveform was represented as a fixed patient-specific template plus an event-specific residual predicted from scalp EEG. Direct scalp-input controls and event-clustered bootstrap confidence intervals were used to distinguish scalp-dependent information from template-driven performance. Results: Where accuracy varied markedly across subjects (0.080–0.984), with an unweighted subject-level mean of 0.333 versus a chance level of 0.125; 95% confidence intervals were above chance level in three of six subjects. Input-control analyses supported a scalp-dependent contribution in subjects with successful localization. For the what task, mean waveform correlation was 0.752 for the model and 0.754 for the fixed patient-specific template (mean difference,-0.002), while residual correlations were generally modest (−0.020 to 0.378). Conclusion: Scalp EEG contained recoverable temporal information in some subjects, but event-specific single-contact morphology was not consistently recovered beyond the patient-specific template. Separating temporal localization from template-based waveform reconstruction provides a more stringent framework for evaluating noninvasive-to-intracranial inference and reduces conflation of prior-driven similarity with input-dependent reconstruction.
Open AccessA Patient-Specific Framework for Separating Temporal Localization from Intracranial Waveform Reconstruction of Interictal Epileptiform Discharges from Scalp EEG
Objective: We developed a patient-specific framework to determine which information about interictal epileptiform discharges (IEDs) can be recovered from scalp EEG, separating temporal localization (“where”) from event-specific intracranial waveform reconstruction (“what”). Methods: Six subjects from a public simultaneous high-density scalp EEG and intracranial EEG (iEEG) dataset were analyzed using patient-specific dual-branch convolutional-attention models integrating waveform/topographic and time-frequency representations. For the where task, a 640-ms scalp EEG segment was divided into eight 80-ms bins, and the model predicted the bin containing the intracranial IED peak. For the what task, a 250-ms peak-centered iEEG waveform was represented as a fixed patient-specific template plus an event-specific residual predicted from scalp EEG. Direct scalp-input controls and event-clustered bootstrap confidence intervals were used to distinguish scalp-dependent information from template-driven performance. Results: Where accuracy varied markedly across subjects (0.080–0.984), with an unweighted subject-level mean of 0.333 versus a chance level of 0.125; 95% confidence intervals were above chance level in three of six subjects. Input-control analyses supported a scalp-dependent contribution in subjects with successful localization. For the what task, mean waveform correlation was 0.752 for the model and 0.754 for the fixed patient-specific template (mean difference,-0.002), while residual correlations were generally modest (−0.020 to 0.378). Conclusion: Scalp EEG contained recoverable temporal information in some subjects, but event-specific single-contact morphology was not consistently recovered beyond the patient-specific template. Separating temporal localization from template-based waveform reconstruction provides a more stringent framework for evaluating noninvasive-to-intracranial inference and reduces conflation of prior-driven similarity with input-dependent reconstruction.
- Open Access
Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Optically pumped magnetometer (OPM) sensors can be placed closer to the scalp than conventional superconducting quantum interference devices (SQUID), resulting in larger magnetoencephalography (MEG) signals from neuronal activity. For event-related sensor data, such as epileptogenic activity or sensory and motor evoked responses, however, OPMs and SQUIDs often differ less in signal-to-noise ratio (SNR) than in signal magnitude. We examined two factors contributing to the relative SNR: the dependence of the signal magnitude on source depth and the effect of scalp-to-sensor distance on the noise level. Simulated MEG data for a current dipole in a spherical head model confirmed that on-scalp sensor placement delivers the largest SNR gain for superficial sources. Depending on the relative overall noise level, there may be a crossover source depth at which SNR is equal for on-scalp and off-scalp sensors and beyond which off-scalp sensors achieve higher SNR. Analysis of the equal-SNR source depth in different-sized spherical head models indicated that, for a given relative noise level, the proportion of the brain where SNR is higher in OPM than in SQUID was larger in small head models, supporting the benefits of OPMs in pediatric studies. To experimentally evaluate noise contributions of brain and non-brain origin to the SNR, we recorded somatosensory evoked fields (SEFs) at varying scalp-to-sensor distances. Generally, both the evoked response magnitude and the noise level were lower when the sensors were further away from the scalp; consequently, the SNR depended less than the signal magnitude on the scalp-to-sensor distance. Comparison of power spectral densities (PSDs) at different sensor-to-scalp distances allowed us to identify whether the dominant noise source was of brain or non-brain origin at different frequency bands. Overall, the results highlight complementary properties of OPMs vs. SQUIDs in terms of SNR, which is of interest when optimizing MEG experiments for specific subject populations and brain regions.
Open AccessSignal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Optically pumped magnetometer (OPM) sensors can be placed closer to the scalp than conventional superconducting quantum interference devices (SQUID), resulting in larger magnetoencephalography (MEG) signals from neuronal activity. For event-related sensor data, such as epileptogenic activity or sensory and motor evoked responses, however, OPMs and SQUIDs often differ less in signal-to-noise ratio (SNR) than in signal magnitude. We examined two factors contributing to the relative SNR: the dependence of the signal magnitude on source depth and the effect of scalp-to-sensor distance on the noise level. Simulated MEG data for a current dipole in a spherical head model confirmed that on-scalp sensor placement delivers the largest SNR gain for superficial sources. Depending on the relative overall noise level, there may be a crossover source depth at which SNR is equal for on-scalp and off-scalp sensors and beyond which off-scalp sensors achieve higher SNR. Analysis of the equal-SNR source depth in different-sized spherical head models indicated that, for a given relative noise level, the proportion of the brain where SNR is higher in OPM than in SQUID was larger in small head models, supporting the benefits of OPMs in pediatric studies. To experimentally evaluate noise contributions of brain and non-brain origin to the SNR, we recorded somatosensory evoked fields (SEFs) at varying scalp-to-sensor distances. Generally, both the evoked response magnitude and the noise level were lower when the sensors were further away from the scalp; consequently, the SNR depended less than the signal magnitude on the scalp-to-sensor distance. Comparison of power spectral densities (PSDs) at different sensor-to-scalp distances allowed us to identify whether the dominant noise source was of brain or non-brain origin at different frequency bands. Overall, the results highlight complementary properties of OPMs vs. SQUIDs in terms of SNR, which is of interest when optimizing MEG experiments for specific subject populations and brain regions.
- Open Access
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Objective: Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly used generalized MEG-only models, whereas clinical MEG interpretation routinely integrates simultaneous electroencephalography (EEG) and includes MEG-unique or MEG-dominant discharges. We developed a patient-specific EEG-MEG IED detector and evaluated event-wise prediction stability across models and the effect of adding EEG to MEG-based prediction. Methods: Seventeen patients undergoing clinical EEG-MEG evaluation for epilepsy were retrospectively analyzed. Clinically accepted dipole-review IEDs were treated as positive events, and nonannotated events were sampled as negatives. Logistic regression (LR), random forest (RF), and a lightweight three-dimensional ResNet were trained separately within each patient using EEG-only, MEG-only, and combined EEG-MEG (EMEG) inputs. Primary performance metrics were the area under the receiver operating characteristic curve (ROC-AUC) and average precision. Event-wise stability was assessed using rank disagreement, rank volatility, and class-aware distribution quotient analysis. Results: Aggregate discrimination was high across models and modalities. Median ROC-AUCs for EEG, MEG, and EMEG were 0.850, 0.890, and 0.880 for LR; 0.880, 0.860, and 0.910 for RF; and 0.920, 0.960, and 0.960 for ResNet. Despite comparable aggregate performance, event-wise analysis revealed model-dependent prediction behavior. ResNet showed significantly lower non-IED rank volatility than classical machine learning models and lower non-IED rank disagreement, particularly compared with RF. Adding EEG to MEG was associated with more favorable class-aware event-wise positioning in most events, while MEG-unique/dominant cases showed greater relative MEG contribution. Conclusions: Patient-specific EEG-MEG IED detection revealed clinically meaningful event-wise differences not captured by aggregate metrics. Simultaneous EEG complemented MEG-based detection, while MEG contribution remained prominent in MEG-dominant cases, supporting multimodal patient-specific IED event prioritization.
Open AccessEvent-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Objective: Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly used generalized MEG-only models, whereas clinical MEG interpretation routinely integrates simultaneous electroencephalography (EEG) and includes MEG-unique or MEG-dominant discharges. We developed a patient-specific EEG-MEG IED detector and evaluated event-wise prediction stability across models and the effect of adding EEG to MEG-based prediction. Methods: Seventeen patients undergoing clinical EEG-MEG evaluation for epilepsy were retrospectively analyzed. Clinically accepted dipole-review IEDs were treated as positive events, and nonannotated events were sampled as negatives. Logistic regression (LR), random forest (RF), and a lightweight three-dimensional ResNet were trained separately within each patient using EEG-only, MEG-only, and combined EEG-MEG (EMEG) inputs. Primary performance metrics were the area under the receiver operating characteristic curve (ROC-AUC) and average precision. Event-wise stability was assessed using rank disagreement, rank volatility, and class-aware distribution quotient analysis. Results: Aggregate discrimination was high across models and modalities. Median ROC-AUCs for EEG, MEG, and EMEG were 0.850, 0.890, and 0.880 for LR; 0.880, 0.860, and 0.910 for RF; and 0.920, 0.960, and 0.960 for ResNet. Despite comparable aggregate performance, event-wise analysis revealed model-dependent prediction behavior. ResNet showed significantly lower non-IED rank volatility than classical machine learning models and lower non-IED rank disagreement, particularly compared with RF. Adding EEG to MEG was associated with more favorable class-aware event-wise positioning in most events, while MEG-unique/dominant cases showed greater relative MEG contribution. Conclusions: Patient-specific EEG-MEG IED detection revealed clinically meaningful event-wise differences not captured by aggregate metrics. Simultaneous EEG complemented MEG-based detection, while MEG contribution remained prominent in MEG-dominant cases, supporting multimodal patient-specific IED event prioritization.
- Open Access
- 15 April 2026
- Published by Elsevier in NeuroImage
- Vol. 333, 121930
Quantifying cerebellar signal detectability in MEG and EEG in epilepsy using anatomically informed source modeling
- 15 April 2026
- Published by Elsevier in NeuroImage
- Vol. 333, 121930
Open AccessQuantifying cerebellar signal detectability in MEG and EEG in epilepsy using anatomically informed source modeling
- Open Access
Quantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling
Objective: The cerebellum is increasingly recognized as a key component of large-scale brain networks implicated in epilepsy, yet its electrophysiological characterization remains limited in noninvasive recordings. This limitation arises from the cerebellum's depth, complex folding, and unfavorable source orientations, which challenge conventional magnetoencephalography (MEG) and electroencephalography (EEG). Here, we quantitatively characterize cerebellar signal detectability across modalities and sensor configurations using anatomically informed source modeling at the population level. Methods: We analyzed clinical MEG and EEG recordings from a large cohort of patients with epilepsy undergoing presurgical evaluation. Cerebellar and cerebral source spaces were constructed using subject-specific anatomical models derived from routine clinical MRI, enabling consistent forward modeling across individuals. Signal-to-noise ratio (SNR) was estimated at individual source locations and summarized at the regional level. In addition to clinical Superconducting quantum interference device (SQUID)-MEG and EEG, multiple on-scalp optically pumped magnetometer (OPM) configurations were evaluated through simulation, including layouts matched to clinical sensor geometries and layouts optimized for posterior fossa coverage. The effects of source orientation, sensor-source distance, and head size on SNR were systematically investigated. Results: In routine clinical recordings, cerebellar SNR was consistently lower than superficial cortical reference levels, confirming the limited detectability of cerebellar activity with standard SQUID-MEG and EEG. Reducing sensor-source distance by placing OPMs at SQUID-equivalent locations, i.e., projecting SQUID sensor locations to the scalp, did not improve cerebellar SNR, indicating that proximity alone is insufficient for better detectability of deeper sources. In contrast, cerebellar-optimized OPM layouts produced substantial SNR gains in posterior cerebellar regions. The effects of source orientation influence SNR differences between OPM and EEG (under identical sensor/electrode coverage) but were secondary to depth- and geometry-related constraints. Mediation analysis further demonstrated that relative sensor distance significantly mediated OPM-related advantages in posterior cerebellar regions, particularly in individuals with smaller head sizes. Conclusions: These findings demonstrate that cerebellar signal detectability is governed primarily by anatomical depth and geometry rather than sensor proximity alone. Anatomically informed source modeling, combined with flexible and region-specific sensor layouts, enables meaningful improvements in cerebellar SNR that are not achievable with fixed-helmet systems. While directly motivated by epilepsy, this framework advances human brain mapping beyond the cerebrum by providing a principled approach for evaluating MEG and EEG sensitivity in deep and highly folded brain structures.
Open AccessQuantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling
Objective: The cerebellum is increasingly recognized as a key component of large-scale brain networks implicated in epilepsy, yet its electrophysiological characterization remains limited in noninvasive recordings. This limitation arises from the cerebellum's depth, complex folding, and unfavorable source orientations, which challenge conventional magnetoencephalography (MEG) and electroencephalography (EEG). Here, we quantitatively characterize cerebellar signal detectability across modalities and sensor configurations using anatomically informed source modeling at the population level. Methods: We analyzed clinical MEG and EEG recordings from a large cohort of patients with epilepsy undergoing presurgical evaluation. Cerebellar and cerebral source spaces were constructed using subject-specific anatomical models derived from routine clinical MRI, enabling consistent forward modeling across individuals. Signal-to-noise ratio (SNR) was estimated at individual source locations and summarized at the regional level. In addition to clinical Superconducting quantum interference device (SQUID)-MEG and EEG, multiple on-scalp optically pumped magnetometer (OPM) configurations were evaluated through simulation, including layouts matched to clinical sensor geometries and layouts optimized for posterior fossa coverage. The effects of source orientation, sensor-source distance, and head size on SNR were systematically investigated. Results: In routine clinical recordings, cerebellar SNR was consistently lower than superficial cortical reference levels, confirming the limited detectability of cerebellar activity with standard SQUID-MEG and EEG. Reducing sensor-source distance by placing OPMs at SQUID-equivalent locations, i.e., projecting SQUID sensor locations to the scalp, did not improve cerebellar SNR, indicating that proximity alone is insufficient for better detectability of deeper sources. In contrast, cerebellar-optimized OPM layouts produced substantial SNR gains in posterior cerebellar regions. The effects of source orientation influence SNR differences between OPM and EEG (under identical sensor/electrode coverage) but were secondary to depth- and geometry-related constraints. Mediation analysis further demonstrated that relative sensor distance significantly mediated OPM-related advantages in posterior cerebellar regions, particularly in individuals with smaller head sizes. Conclusions: These findings demonstrate that cerebellar signal detectability is governed primarily by anatomical depth and geometry rather than sensor proximity alone. Anatomically informed source modeling, combined with flexible and region-specific sensor layouts, enables meaningful improvements in cerebellar SNR that are not achievable with fixed-helmet systems. While directly motivated by epilepsy, this framework advances human brain mapping beyond the cerebrum by providing a principled approach for evaluating MEG and EEG sensitivity in deep and highly folded brain structures.
- Open Access
Biplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards
Optically pumped magnetometers (OPMs) are a promising magnetoencephalography (MEG) technology for the non-invasive measurement of human electrophysiological signals. Prior work developed biplanar background field-nulling coils necessary for OPM operation, but these were expensive to produce and required tedious error-prone manual winding of >1 km of copper wire. Here, we developed a precise and reproducible manufacturing process by fabricating these coils on two-layer printed circuit boards (PCBs). Building on open-source software (bfieldtools), we developed a pipeline to determine the optimal current loops of 1.5 × 1.5 m2 biplanar nulling coils, connected these loops into a continuous conducting path across PCB layers, and printed them as pairs of 1.5 × 0.75 m2 PCBs, which were soldered and mounted on an aluminum frame. Our coils achieved efficiencies of 1.3–7.1 nT/mA, similar to or higher than previous designs. We reduced the largest background field component from 21 to 2 nT, enabling OPMs in a lightly shielded room to record somatosensory evoked fields (SEFs) comparable to SQUID-MEG. Our coil system is cheaper than commercial alternatives and is available as an open-source package opmcoils, thus enabling more affordable background field nulling for OPM-MEG and realizing its potential as an accessible sensor technology for human neuroscience.
Open AccessBiplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards
Optically pumped magnetometers (OPMs) are a promising magnetoencephalography (MEG) technology for the non-invasive measurement of human electrophysiological signals. Prior work developed biplanar background field-nulling coils necessary for OPM operation, but these were expensive to produce and required tedious error-prone manual winding of >1 km of copper wire. Here, we developed a precise and reproducible manufacturing process by fabricating these coils on two-layer printed circuit boards (PCBs). Building on open-source software (bfieldtools), we developed a pipeline to determine the optimal current loops of 1.5 × 1.5 m2 biplanar nulling coils, connected these loops into a continuous conducting path across PCB layers, and printed them as pairs of 1.5 × 0.75 m2 PCBs, which were soldered and mounted on an aluminum frame. Our coils achieved efficiencies of 1.3–7.1 nT/mA, similar to or higher than previous designs. We reduced the largest background field component from 21 to 2 nT, enabling OPMs in a lightly shielded room to record somatosensory evoked fields (SEFs) comparable to SQUID-MEG. Our coil system is cheaper than commercial alternatives and is available as an open-source package opmcoils, thus enabling more affordable background field nulling for OPM-MEG and realizing its potential as an accessible sensor technology for human neuroscience.
- 16 February 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 161, 52-58
Delays in latencies of median-nerve evoked magnetic fields in patients with succinic semialdehyde dehydrogenase deficiency
- 16 February 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 161, 52-58
Delays in latencies of median-nerve evoked magnetic fields in patients with succinic semialdehyde dehydrogenase deficiency
- Open Access
- 25 February 2022
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 13, 762497
Weighted Blind Source Separation Can Decompose the Frequency Mismatch Response by Deviant Concatenation: An MEG Study
The mismatch response (MMR) is thought to be a neurophysiological measure of novel auditory detection that could serve as a translational biomarker of various neurological diseases. When recorded with electroencephalography (EEG) or magnetoencephalography (MEG), the MMR is traditionally extracted by subtracting the event-related potential/field (ERP/ERF) elicited in response to “deviant” sounds that occur randomly within a train of repetitive “standard” sounds. However, there are several problems with such a subtraction, which include increased noise and the neural adaptation problem. On the basis of the original theory underlying MMR (i.e., the memory-comparison process), the MMR should be present only in deviant epochs. Therefore, we proposed a novel method called weighted-BSST/k, which uses only the deviant response to derive the MMR. Deviant concatenation and weight assignment are the primary procedures of weighted-BSST/k, which maximize the benefits of time-delayed correlation. We hypothesized that this novel weighted-BSST/k method highlights responses related to the detection of the deviant stimulus and is more sensitive than independent component analysis (ICA). To test this hypothesis and the validity and efficacy of the weighted-BSST/k in comparison with ICA (infomax), we evaluated the methods in 12 healthy adults. Auditory stimuli were presented at a constant rate of 2 Hz. Frequency MMRs at a sensor level were obtained from the bilateral temporal lobes with the subtraction approach at 96–276 ms (the MMR time range), defined based on spatio-temporal cluster permutation analysis. In the application of the weighted-BSST/k, the deviant responses were given a constant weight using a rectangular window on the MMR time range. The ERF elicited by the weighted deviant responses demonstrated one or a few dominant components representing the MMR that fitted well with that of the sensor space analysis using the conventional subtraction approach. In contrast, infomax or weighted-infomax revealed many minor or pseudo components as constituents of the MMR. Our single-trial, contrast-free approach may assist in using the MMR in basic and clinical research, and it opens a new and potentially useful way to analyze event-related MEG/EEG data.
- 25 February 2022
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 13, 762497
Open AccessWeighted Blind Source Separation Can Decompose the Frequency Mismatch Response by Deviant Concatenation: An MEG Study
The mismatch response (MMR) is thought to be a neurophysiological measure of novel auditory detection that could serve as a translational biomarker of various neurological diseases. When recorded with electroencephalography (EEG) or magnetoencephalography (MEG), the MMR is traditionally extracted by subtracting the event-related potential/field (ERP/ERF) elicited in response to “deviant” sounds that occur randomly within a train of repetitive “standard” sounds. However, there are several problems with such a subtraction, which include increased noise and the neural adaptation problem. On the basis of the original theory underlying MMR (i.e., the memory-comparison process), the MMR should be present only in deviant epochs. Therefore, we proposed a novel method called weighted-BSST/k, which uses only the deviant response to derive the MMR. Deviant concatenation and weight assignment are the primary procedures of weighted-BSST/k, which maximize the benefits of time-delayed correlation. We hypothesized that this novel weighted-BSST/k method highlights responses related to the detection of the deviant stimulus and is more sensitive than independent component analysis (ICA). To test this hypothesis and the validity and efficacy of the weighted-BSST/k in comparison with ICA (infomax), we evaluated the methods in 12 healthy adults. Auditory stimuli were presented at a constant rate of 2 Hz. Frequency MMRs at a sensor level were obtained from the bilateral temporal lobes with the subtraction approach at 96–276 ms (the MMR time range), defined based on spatio-temporal cluster permutation analysis. In the application of the weighted-BSST/k, the deviant responses were given a constant weight using a rectangular window on the MMR time range. The ERF elicited by the weighted deviant responses demonstrated one or a few dominant components representing the MMR that fitted well with that of the sensor space analysis using the conventional subtraction approach. In contrast, infomax or weighted-infomax revealed many minor or pseudo components as constituents of the MMR. Our single-trial, contrast-free approach may assist in using the MMR in basic and clinical research, and it opens a new and potentially useful way to analyze event-related MEG/EEG data.
- Open Access
- 26 October 2021
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 12
Bilateral Representation of Sensorimotor Responses in Benign Adult Familial Myoclonus Epilepsy: An MEG Study
Patients with cortical reflex myoclonus manifest typical neurophysiologic characteristics due to primary sensorimotor cortex (S1/M1) hyperexcitability, namely, contralateral giant somatosensory-evoked potentials/fields and a C-reflex (CR) in the stimulated arm. Some patients show a CR in both arms in response to unilateral stimulation, with about 10-ms delay in the non-stimulated compared with the stimulated arm. This bilateral C-reflex (BCR) may reflect strong involvement of bilateral S1/M1. However, the significance and exact pathophysiology of BCR within 50 ms are yet to be established because it is difficult to identify a true ipsilateral response in the presence of the giant component in the contralateral hemisphere. We hypothesized that in patients with BCR, bilateral S1/M1 activity will be detected using MEG source localization and interhemispheric connectivity will be stronger than in healthy controls (HCs) between S1/M1 cortices. We recruited five patients with cortical reflex myoclonus with BCR and 15 HCs. All patients had benign adult familial myoclonus epilepsy. The median nerve was electrically stimulated unilaterally. Ipsilateral activity was investigated in functional regions of interest that were determined by the N20m response to contralateral stimulation. Functional connectivity was investigated using weighted phase-lag index (wPLI) in the time-frequency window of 30–50 ms and 30–100 Hz. Among seven of the 10 arms of the patients who showed BCR, the average onset-to-onset delay between the stimulated and the non-stimulated arm was 8.4 ms. Ipsilateral S1/M1 activity was prominent in patients. The average time difference between bilateral cortical activities was 9.4 ms. The average wPLI was significantly higher in the patients compared with HCs in specific cortico-cortical connections. These connections included precentral-precentral, postcentral-precentral, inferior parietal (IP)-precentral, and IP-postcentral cortices interhemispherically (contralateral region-ipsilateral region), and precentral-IP and postcentral-IP intrahemispherically (contralateral region-contralateral region). The ipsilateral response in patients with BCR may be a pathologically enhanced motor response homologous to the giant component, which was too weak to be reliably detected in HCs. Bilateral representation of sensorimotor responses is associated with disinhibition of the transcallosal inhibitory pathway within homologous motor cortices, which is mediated by the IP. IP may play a role in suppressing the inappropriate movements seen in cortical myoclonus.
- 26 October 2021
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 12
Open AccessBilateral Representation of Sensorimotor Responses in Benign Adult Familial Myoclonus Epilepsy: An MEG Study
Patients with cortical reflex myoclonus manifest typical neurophysiologic characteristics due to primary sensorimotor cortex (S1/M1) hyperexcitability, namely, contralateral giant somatosensory-evoked potentials/fields and a C-reflex (CR) in the stimulated arm. Some patients show a CR in both arms in response to unilateral stimulation, with about 10-ms delay in the non-stimulated compared with the stimulated arm. This bilateral C-reflex (BCR) may reflect strong involvement of bilateral S1/M1. However, the significance and exact pathophysiology of BCR within 50 ms are yet to be established because it is difficult to identify a true ipsilateral response in the presence of the giant component in the contralateral hemisphere. We hypothesized that in patients with BCR, bilateral S1/M1 activity will be detected using MEG source localization and interhemispheric connectivity will be stronger than in healthy controls (HCs) between S1/M1 cortices. We recruited five patients with cortical reflex myoclonus with BCR and 15 HCs. All patients had benign adult familial myoclonus epilepsy. The median nerve was electrically stimulated unilaterally. Ipsilateral activity was investigated in functional regions of interest that were determined by the N20m response to contralateral stimulation. Functional connectivity was investigated using weighted phase-lag index (wPLI) in the time-frequency window of 30–50 ms and 30–100 Hz. Among seven of the 10 arms of the patients who showed BCR, the average onset-to-onset delay between the stimulated and the non-stimulated arm was 8.4 ms. Ipsilateral S1/M1 activity was prominent in patients. The average time difference between bilateral cortical activities was 9.4 ms. The average wPLI was significantly higher in the patients compared with HCs in specific cortico-cortical connections. These connections included precentral-precentral, postcentral-precentral, inferior parietal (IP)-precentral, and IP-postcentral cortices interhemispherically (contralateral region-ipsilateral region), and precentral-IP and postcentral-IP intrahemispherically (contralateral region-contralateral region). The ipsilateral response in patients with BCR may be a pathologically enhanced motor response homologous to the giant component, which was too weak to be reliably detected in HCs. Bilateral representation of sensorimotor responses is associated with disinhibition of the transcallosal inhibitory pathway within homologous motor cortices, which is mediated by the IP. IP may play a role in suppressing the inappropriate movements seen in cortical myoclonus.
- 1 November 2020
- Published by Elsevier in Women and Birth
- Vol. 33 (6) , e574-e575
Mobile applications for fetal movement: Only decreased movement matters?
- 1 November 2020
- Published by Elsevier in Women and Birth
- Vol. 33 (6) , e574-e575
Mobile applications for fetal movement: Only decreased movement matters?