Nicholas E. Schlotter
Research Subjects
Research Interests
Nicholas E. Schlotter has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
J. F. Rabolt
IBM Research Laboratory, San Jose, California 95193
8 shared publicationsJ. D. Swalen
IBM Research Laboratory, San Jose, California 95193
5 shared publications- Paul D. Townsend
University College Cork
4 shared publications R. Bhat
Bellcore, 331 Newman Springs Road, Red Bank, New Jersey 07701
4 shared publicationsS. Etemad
Bell Communications Research, Red Bank, N.J. 07701, U.S.A.
4 shared publicationsJ.F. Rabolt
IBM Research Laboratory, San Jose, California 95193, USA
3 shared publications
Latest Publications
- Top Cited Papers
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Chemical Society Reviews
- Vol. 45 (14) , 3865-3882
Prospects for point-of-care pathogen diagnostics using surface-enhanced Raman scattering (SERS)
Surface-enhanced Raman scattering (SERS) has enabled the detection of pathogens and disease markers at extremely low levels. This review examines the potential impact of SERS in addressing unmet needs in pathogen diagnostics both in a traditional clinical setting and in the point of care (POC) arena. It begins by describing the strengths and weaknesses of today's diagnostics technologies in order to set a contextual stage for an overview which highlights a few of the many recent developments using SERS in biodefense, human and animal health, and monitoring food and water safety. These sections are followed by discussions of the challenges for the translation of these developments to POC settings, including the performance attributes and metrics for quantification of analytical and clinical figures of merit (e.g., limit of detection and clinical accuracy), and the pathways for large-scale test validation and the build-out of instrumentation and tests kits for POC deployment.
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Chemical Society Reviews
- Vol. 45 (14) , 3865-3882
Top Cited PapersProspects for point-of-care pathogen diagnostics using surface-enhanced Raman scattering (SERS)
Surface-enhanced Raman scattering (SERS) has enabled the detection of pathogens and disease markers at extremely low levels. This review examines the potential impact of SERS in addressing unmet needs in pathogen diagnostics both in a traditional clinical setting and in the point of care (POC) arena. It begins by describing the strengths and weaknesses of today's diagnostics technologies in order to set a contextual stage for an overview which highlights a few of the many recent developments using SERS in biodefense, human and animal health, and monitoring food and water safety. These sections are followed by discussions of the challenges for the translation of these developments to POC settings, including the performance attributes and metrics for quantification of analytical and clinical figures of merit (e.g., limit of detection and clinical accuracy), and the pathways for large-scale test validation and the build-out of instrumentation and tests kits for POC deployment.
- 13 December 2012
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 90 (1) , 51-55
A Statistics Curriculum for the Undergraduate Chemistry Major
- 13 December 2012
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 90 (1) , 51-55
A Statistics Curriculum for the Undergraduate Chemistry Major
- 1 October 2007
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 353 (30-31) , 2932-2933
Correction to “Preparation of monodisperse silica particles: Control of size and mass fraction” by G.H. Bogush, M.A. Tracy and C.F. Zukoski IV, Journal of Non-Crystalline Solids 104 (1988) 95–106
- 1 October 2007
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 353 (30-31) , 2932-2933
Correction to “Preparation of monodisperse silica particles: Control of size and mass fraction” by G.H. Bogush, M.A. Tracy and C.F. Zukoski IV, Journal of Non-Crystalline Solids 104 (1988) 95–106
- 1 April 1992
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 3 (2) , 147-153
Small molecule diffusion in polyolefins monitored using the infrared evanescent field
- 1 April 1992
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 3 (2) , 147-153
Small molecule diffusion in polyolefins monitored using the infrared evanescent field
- 31 December 1990
- Published by Elsevier in Synthetic Metals
- Vol. 39 (2) , 215-224
Dielectric properties, vibrational and ESR spectra of electrochemically prepared poly(N-methylpyrrole): effect of supporting electrolytes
- 31 December 1990
- Published by Elsevier in Synthetic Metals
- Vol. 39 (2) , 215-224
Dielectric properties, vibrational and ESR spectra of electrochemically prepared poly(N-methylpyrrole): effect of supporting electrolytes
- 21 May 1990
- Published by AIP Publishing in Applied Physics Letters
- Vol. 56 (21) , 2132-2134
InGaAs shallow junction fabrication using Langmuir–Blodgett film diffusion source
A new source of cadmium diffusion in In0.53Ga0.47As has been developed. Langmuir–Blodgett (LB) deposited monolayers of cadmium arachidate have been used as a source of cadmium. The LB film has been characterized by grazing incidence infrared spectroscopy and Auger electron spectroscopy. Acceptor profiles obtained by differential Hall technique are presented. Highly doped (NA =2×1019 cm−3) shallow (xj ≊0.1–0.4 μm), p+‐n junctions are obtained. Mesa‐type p‐i‐n diodes with 125 μm diameter, ideality factor =1.3, Idark =5 nA at 20 V reverse bias, and Vbreakdown =30 V have been fabricated.
- 21 May 1990
- Published by AIP Publishing in Applied Physics Letters
- Vol. 56 (21) , 2132-2134
InGaAs shallow junction fabrication using Langmuir–Blodgett film diffusion source
A new source of cadmium diffusion in In0.53Ga0.47As has been developed. Langmuir–Blodgett (LB) deposited monolayers of cadmium arachidate have been used as a source of cadmium. The LB film has been characterized by grazing incidence infrared spectroscopy and Auger electron spectroscopy. Acceptor profiles obtained by differential Hall technique are presented. Highly doped (NA =2×1019 cm−3) shallow (xj ≊0.1–0.4 μm), p+‐n junctions are obtained. Mesa‐type p‐i‐n diodes with 125 μm diameter, ideality factor =1.3, Idark =5 nA at 20 V reverse bias, and Vbreakdown =30 V have been fabricated.
- 1 February 1990
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 94 (4) , 1692-1699
Diffusion of small molecules in glassy polymer thin films studied by waveguide Raman techniques
- 1 February 1990
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 94 (4) , 1692-1699
Diffusion of small molecules in glassy polymer thin films studied by waveguide Raman techniques
- 1 January 1990
- Published by AIP Publishing in Applied Physics Letters
- Vol. 56 (1) , 13-15
Fabrication of channel waveguides in polydiacetylenes: Composite diffused glass/polymer structures
We report the fabrication of single‐mode channel waveguides in spun films of polydiacetylenes using an inverted rib design. These robust guides consist of a planar layer of the polydiacetylene spun on a glass substrate in which high‐index channels have been defined by ion exchange. Models of such guides show that most of the optical field of the guided wave is confined to the polymer layer, with the high‐index glass channels providing lateral confinement. End‐fire coupling of 1.06, 1.15, 1.32, and 1.55 μm light into the composite guides resulted in single‐mode guiding with the light confined to the polymer layer. This approach to waveguide formation should be applicable to a wide range of polymeric materials.
- 1 January 1990
- Published by AIP Publishing in Applied Physics Letters
- Vol. 56 (1) , 13-15
Fabrication of channel waveguides in polydiacetylenes: Composite diffused glass/polymer structures
We report the fabrication of single‐mode channel waveguides in spun films of polydiacetylenes using an inverted rib design. These robust guides consist of a planar layer of the polydiacetylene spun on a glass substrate in which high‐index channels have been defined by ion exchange. Models of such guides show that most of the optical field of the guided wave is confined to the polymer layer, with the high‐index glass channels providing lateral confinement. End‐fire coupling of 1.06, 1.15, 1.32, and 1.55 μm light into the composite guides resulted in single‐mode guiding with the light confined to the polymer layer. This approach to waveguide formation should be applicable to a wide range of polymeric materials.
- 1 September 1989
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 10 (9) , 417-419
High-speed Ga/sub 0.47/In/sub 0.53/As MISIM photodetectors with dielectric-assisted Schottky barriers
A technique is described for fabricating high-speed metal-insulator-semiconductor-insulator-metal (MISIM) photodetectors for high-speed fiber-optic systems. These devices make use of a Langmuir-Blodgett film enhanced Schottky barrier to achieve broadband linear response to 13 GHz at low bias voltage (5 V) with approximately 0.9 A/W external responsivity, 15 V breakdown voltage, and approximately 2 mu A dark current. A gain of about 2 and a 5% tail in the temporal response are analyzed. The needed bias and the device processing are compatible with those for integrated receivers.
- 1 September 1989
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 10 (9) , 417-419
High-speed Ga/sub 0.47/In/sub 0.53/As MISIM photodetectors with dielectric-assisted Schottky barriers
A technique is described for fabricating high-speed metal-insulator-semiconductor-insulator-metal (MISIM) photodetectors for high-speed fiber-optic systems. These devices make use of a Langmuir-Blodgett film enhanced Schottky barrier to achieve broadband linear response to 13 GHz at low bias voltage (5 V) with approximately 0.9 A/W external responsivity, 15 V breakdown voltage, and approximately 2 mu A dark current. A gain of about 2 and a 5% tail in the temporal response are analyzed. The needed bias and the device processing are compatible with those for integrated receivers.