Martin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Martin Li has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Amirul Adlan
Trauma and Orthopaedics, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
1 shared publicationBashar Alhani
Royal Orthopaedic Hospital, Birmingham, UK
1 shared publication- Chaninda Dejsupa
Trauma and Orthopaedics, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
1 shared publication - Cheuk-Man Yu
Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong
1 shared publication - Chi Kwong Wong
Department of Architecture and Civil Engineering, City University of Hong Kong, Kowloon Tong, HKSAR, Hong Kong
1 shared publication Daniel P. Howard
University Hospital Coventry and Warwickshire NHS Trust, Department of Trauma and Orthopaedics, Clifford Bridge Road, Coventry, CV2 2DX, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (4) , e003606
Implementation of Digital Consent at Sandwell and West Birmingham NHS Trust: A Quality Improvement Project
Digital consent systems provide a modern alternative to traditional paper-based methods, improving legibility, documentation accuracy, compliance with National Health Service (NHS) medicolegal standards and patient understanding. This quality improvement project evaluated the implementation of a digital consent system in the Trauma and Orthopaedics department at Sandwell and West Birmingham NHS Trust, comparing paper-based consent with the digital system. Baseline data were collected retrospectively from July to August 2024 and compared with prospective data following implementation from August to October 2024, using quantitative measures of documentation quality and qualitative feedback from healthcare professionals (n=24) and patient (n=619) surveys. An iterative Plan-Do-Study-Act cycle approach was used to refine the process. Following implementation, legibility improved from 42–48% to 100% across all digital consents, and documentation of alternative treatment options increased substantially from 5% to 95% in trauma cases and from 0% to 98% in elective cases. Risks and benefits were documented in 100% of digital consents. Patient and clinician surveys demonstrated high satisfaction, with a mean System Usability Score of 77.5, comparable to high-performing consumer technology platforms. Identified barriers included accessibility issues for less digitally literate patients and technical challenges such as digital signing on smaller devices. The transition to digital consent resulted in a cumulative cost saving of £2552.90 over the first 7 months. The introduction of digital consent significantly improved documentation quality, patient and clinician satisfaction and generated measurable cost savings. Ongoing challenges relating to accessibility and technical usability require targeted interventions. This project demonstrates the potential for digital consent systems to support efficient, sustainable and patient-centred care, with opportunities for broader adoption across NHS specialties.
- 1 October 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (4) , e003606
Open AccessImplementation of Digital Consent at Sandwell and West Birmingham NHS Trust: A Quality Improvement Project
Digital consent systems provide a modern alternative to traditional paper-based methods, improving legibility, documentation accuracy, compliance with National Health Service (NHS) medicolegal standards and patient understanding. This quality improvement project evaluated the implementation of a digital consent system in the Trauma and Orthopaedics department at Sandwell and West Birmingham NHS Trust, comparing paper-based consent with the digital system. Baseline data were collected retrospectively from July to August 2024 and compared with prospective data following implementation from August to October 2024, using quantitative measures of documentation quality and qualitative feedback from healthcare professionals (n=24) and patient (n=619) surveys. An iterative Plan-Do-Study-Act cycle approach was used to refine the process. Following implementation, legibility improved from 42–48% to 100% across all digital consents, and documentation of alternative treatment options increased substantially from 5% to 95% in trauma cases and from 0% to 98% in elective cases. Risks and benefits were documented in 100% of digital consents. Patient and clinician surveys demonstrated high satisfaction, with a mean System Usability Score of 77.5, comparable to high-performing consumer technology platforms. Identified barriers included accessibility issues for less digitally literate patients and technical challenges such as digital signing on smaller devices. The transition to digital consent resulted in a cumulative cost saving of £2552.90 over the first 7 months. The introduction of digital consent significantly improved documentation quality, patient and clinician satisfaction and generated measurable cost savings. Ongoing challenges relating to accessibility and technical usability require targeted interventions. This project demonstrates the potential for digital consent systems to support efficient, sustainable and patient-centred care, with opportunities for broader adoption across NHS specialties.
- 16 July 2025
- Published by SAGE Publications in HAND
- Vol. 21 (6) , 908-914
Long Thoracic Nerve Decompression and Transfer: Single-Center Case Series of Clinical and Electromyographic Outcomes
Background: Long thoracic nerve (LTN) decompression is considered in recalcitrant scapular winging secondary to chronic LTN palsy. Nerve transfer, typically from the thoracodorsal nerve (TDN), is suggested if, despite adequate decompression, intraoperative nerve stimulation demonstrates no improvement. Literature concerning transfer is scarce. To evaluate and compare these 2 procedures’ clinical and electrical outcomes, we performed a single-center, retrospective case series of all LTN decompression patients with or without transfer for chronic LTN palsy, examining postoperative adapted Medical Research Council (MRC) grades as a primary and electromyography (EMG) stimulation thresholds as a secondary outcome. Methods: We identified 11 decompression-only and 6 patients undergoing additional transfer over an 8-year period, confirmed with preoperative serratus anterior EMG. Decompression involved proximal and distal neurolysis, with transfer, typically the lateral branch of TDN, reserved for irresponsiveness to intraoperative stimulation following decompression. Adapted pre- and postoperative serratus anterior MRC values were evaluated using a 2-tailed Student t test. Results: Preoperative adapted MRC grades for all 17 patients was 0; at median 12-month follow-up, this reached 3. The decompression-only preoperative median was 0 and final grade 3; for the transfers, these were 0 and 3.5 respectively, which were insignificantly different. However, time to first recovery, the first clinical evidence of serratus anterior contraction, was significantly different between the decompression-only cohort, at 3 weeks, and transfer, 7 months. Preoperative EMG thresholds were 1.0 mA pre- and 0.1 mA postoperatively; they did not impact final adapted MRC grades. Conclusions: We conclude nerve transfers achieve comparable long-term outcomes where decompression alone did not improve intraoperative nerve stimulation.
- 16 July 2025
- Published by SAGE Publications in HAND
- Vol. 21 (6) , 908-914
Long Thoracic Nerve Decompression and Transfer: Single-Center Case Series of Clinical and Electromyographic Outcomes
Background: Long thoracic nerve (LTN) decompression is considered in recalcitrant scapular winging secondary to chronic LTN palsy. Nerve transfer, typically from the thoracodorsal nerve (TDN), is suggested if, despite adequate decompression, intraoperative nerve stimulation demonstrates no improvement. Literature concerning transfer is scarce. To evaluate and compare these 2 procedures’ clinical and electrical outcomes, we performed a single-center, retrospective case series of all LTN decompression patients with or without transfer for chronic LTN palsy, examining postoperative adapted Medical Research Council (MRC) grades as a primary and electromyography (EMG) stimulation thresholds as a secondary outcome. Methods: We identified 11 decompression-only and 6 patients undergoing additional transfer over an 8-year period, confirmed with preoperative serratus anterior EMG. Decompression involved proximal and distal neurolysis, with transfer, typically the lateral branch of TDN, reserved for irresponsiveness to intraoperative stimulation following decompression. Adapted pre- and postoperative serratus anterior MRC values were evaluated using a 2-tailed Student t test. Results: Preoperative adapted MRC grades for all 17 patients was 0; at median 12-month follow-up, this reached 3. The decompression-only preoperative median was 0 and final grade 3; for the transfers, these were 0 and 3.5 respectively, which were insignificantly different. However, time to first recovery, the first clinical evidence of serratus anterior contraction, was significantly different between the decompression-only cohort, at 3 weeks, and transfer, 7 months. Preoperative EMG thresholds were 1.0 mA pre- and 0.1 mA postoperatively; they did not impact final adapted MRC grades. Conclusions: We conclude nerve transfers achieve comparable long-term outcomes where decompression alone did not improve intraoperative nerve stimulation.
- 27 November 2022
- Published by Springer Nature in European Spine Journal
- Vol. 32 (7) , 2607-2614
Patient-specific 3D printing to replace components of a rib-to pelvis “Eiffel Tower” vertebral expanding prosthetic titanium rib system in an infant: a case report
Purpose To address the anatomical challenges facing complex and revision spinal surgery, patient-specific 3D-printed models (3D-PMs) have received growing attention worldwide, primarily in adults. We report the use of a 3D-PM in the treatment of a case of wound breakdown over a component of a VEPTR (Vertical Expandable Prosthetic Titanium Rib; DePuy-Synthes) system, requiring replacement of Dunn-McCarthy hook and sleeve with components contoured to a patient-specific 3D-PM of the spine. Method A two-year-old born with myelomeningocele (MMC), repaired at birth, developed progressive MMC-associated kyphoscoliosis. Elective insertion of a rib-to-pelvis ‘Eiffel Tower’ bilateral VEPTR growing rods construct was performed without initial complication. Prominence of the right VEPTR sleeve and Dunn-McCarthy hook side-to-side connector resulted in breakdown of overlying poor-quality soft tissues, necessitating washout, partial implant removal, intravenous antibiotic therapy and delayed primary wound closure. A patient-specific 3D-PM, utilising pre-operative CT spine and pelvis 3D-reconstructions, allowed pre-operative formation of a contoured implant, which was inserted without need for further revision. Results The patient underwent further VEPTR lengthening without recurrent infection, wound breakdown or implant failure at 24-month follow-up. Satisfactory control of the deformity has been achieved with continued improvement in sitting height and radiographic indices. Conclusion This case illustrates the possibility, in certain cases, of using 3D-PM to develop complex components of spinal implant systems pre-operatively, removing the time and difficulty of intra-operative contouring. Consequently, custom-contoured implants may be produced, sterilised and implanted. This technique may be an option, in infants, including MMC-associated kyphoscoliosis, where midline fixation is not possible.
- 27 November 2022
- Published by Springer Nature in European Spine Journal
- Vol. 32 (7) , 2607-2614
Patient-specific 3D printing to replace components of a rib-to pelvis “Eiffel Tower” vertebral expanding prosthetic titanium rib system in an infant: a case report
Purpose To address the anatomical challenges facing complex and revision spinal surgery, patient-specific 3D-printed models (3D-PMs) have received growing attention worldwide, primarily in adults. We report the use of a 3D-PM in the treatment of a case of wound breakdown over a component of a VEPTR (Vertical Expandable Prosthetic Titanium Rib; DePuy-Synthes) system, requiring replacement of Dunn-McCarthy hook and sleeve with components contoured to a patient-specific 3D-PM of the spine. Method A two-year-old born with myelomeningocele (MMC), repaired at birth, developed progressive MMC-associated kyphoscoliosis. Elective insertion of a rib-to-pelvis ‘Eiffel Tower’ bilateral VEPTR growing rods construct was performed without initial complication. Prominence of the right VEPTR sleeve and Dunn-McCarthy hook side-to-side connector resulted in breakdown of overlying poor-quality soft tissues, necessitating washout, partial implant removal, intravenous antibiotic therapy and delayed primary wound closure. A patient-specific 3D-PM, utilising pre-operative CT spine and pelvis 3D-reconstructions, allowed pre-operative formation of a contoured implant, which was inserted without need for further revision. Results The patient underwent further VEPTR lengthening without recurrent infection, wound breakdown or implant failure at 24-month follow-up. Satisfactory control of the deformity has been achieved with continued improvement in sitting height and radiographic indices. Conclusion This case illustrates the possibility, in certain cases, of using 3D-PM to develop complex components of spinal implant systems pre-operatively, removing the time and difficulty of intra-operative contouring. Consequently, custom-contoured implants may be produced, sterilised and implanted. This technique may be an option, in infants, including MMC-associated kyphoscoliosis, where midline fixation is not possible.
- Open Access
- 1 January 2017
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2017 (1) , 3792610
Ligament Augmentation and Reconstruction System Failures in Repair of Grade V Acromioclavicular Joint Dislocation
The Ligament Augmentation and Reconstruction System® (LARS®) represents a popular synthetic anatomical reduction method for acromioclavicular joint dislocation by means of coracoclavicular ligament reconstruction. To our knowledge, no early failure has been documented in the literature. We present two unusual cases of LARS failure, one at four months after implant and the other at three weeks, without obvious causes, requiring re‐do reconstruction, and discuss potential contributory factors.
- 1 January 2017
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2017 (1) , 3792610
Open AccessLigament Augmentation and Reconstruction System Failures in Repair of Grade V Acromioclavicular Joint Dislocation
The Ligament Augmentation and Reconstruction System® (LARS®) represents a popular synthetic anatomical reduction method for acromioclavicular joint dislocation by means of coracoclavicular ligament reconstruction. To our knowledge, no early failure has been documented in the literature. We present two unusual cases of LARS failure, one at four months after implant and the other at three weeks, without obvious causes, requiring re‐do reconstruction, and discuss potential contributory factors.
- Open Access
- 24 August 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 32116
Carotid plaque and bone density and microarchitecture in psoriatic arthritis: the correlation with soluble ST2
Psoriatic arthritis (PsA) patients have increased risk of both atherosclerosis and osteoporosis. Previous studies revealed that IL-33/ST2 axis may be related to both conditions; however, these associations were never evaluated in a single patients’ group. Here we explored the association among plasma levels of IL-33 and its decoy receptor soluble ST2 (sST2), carotid plaque determined by ultrasound, and volumetric bone mineral density (vBMD)/microstructure of distal radius measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 80 PsA patients (55% male; 53.0 ± 10.1 years). Plasma sST2 levels were significantly higher in 33 (41%) patients with carotid plaques (11.2 ± 4.5 vs 7.7 ± 3.7 ng/ml, P < 0.001). In multivariate analysis, sST2 was an independent explanatory variable associated with carotid plaques (OR = 1.296, 95% CI: [1.091,1.540]; P = 0.003). After adjustment for the osteoporotic risk factors, sST2 was significantly associated with higher cortical porosity (β = 0.184, [0.042,0.325]; P = 0.012) and cortical pore volume (2.247, [0.434,4.060]; P = 0.016); and had a trend to be associated with lower cortical vBMD (−2.918, [−6.111,0.275]; P = 0.073). IL-33 was not associated with carotid plaque or vBMD/microstructure. In conclusion, plasma sST2 levels were independently correlated with both carotid plaque and compromised cortical vBMD/microstructure in PsA patients. IL-33/ST2 axis may be a link between accelerated atherosclerosis and osteoporosis in PsA.
- 24 August 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 32116
Open AccessCarotid plaque and bone density and microarchitecture in psoriatic arthritis: the correlation with soluble ST2
Psoriatic arthritis (PsA) patients have increased risk of both atherosclerosis and osteoporosis. Previous studies revealed that IL-33/ST2 axis may be related to both conditions; however, these associations were never evaluated in a single patients’ group. Here we explored the association among plasma levels of IL-33 and its decoy receptor soluble ST2 (sST2), carotid plaque determined by ultrasound, and volumetric bone mineral density (vBMD)/microstructure of distal radius measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 80 PsA patients (55% male; 53.0 ± 10.1 years). Plasma sST2 levels were significantly higher in 33 (41%) patients with carotid plaques (11.2 ± 4.5 vs 7.7 ± 3.7 ng/ml, P < 0.001). In multivariate analysis, sST2 was an independent explanatory variable associated with carotid plaques (OR = 1.296, 95% CI: [1.091,1.540]; P = 0.003). After adjustment for the osteoporotic risk factors, sST2 was significantly associated with higher cortical porosity (β = 0.184, [0.042,0.325]; P = 0.012) and cortical pore volume (2.247, [0.434,4.060]; P = 0.016); and had a trend to be associated with lower cortical vBMD (−2.918, [−6.111,0.275]; P = 0.073). IL-33 was not associated with carotid plaque or vBMD/microstructure. In conclusion, plasma sST2 levels were independently correlated with both carotid plaque and compromised cortical vBMD/microstructure in PsA patients. IL-33/ST2 axis may be a link between accelerated atherosclerosis and osteoporosis in PsA.
- 3 February 2016
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 8 (2) , 118-123
Accuracy of patient-reported range of elbow motion
Patient-reported outcome meaures (PROMs) not only provide valuable insights into subjective indices of joint health, but also may provide limited objective information about range of motion (ROM). We sought to evaluate the accuracy of patient-reported range of elbow motion compared to measured ROM. Sixty clinic patients were recruited, of whom 26 had elbow pathologies and 34 had pathologies other than at the elbow joint. Each patient independently estimated ROM for extension, flexion, pronation and supination before this was measured by a clinician using a universal goniometer, with the mean being the gold standard. We found that patients’ ROM estimates were significantly different from measured ROM (p < 0.00001 at 95% confidence interval). There was no statistically significant difference between elbow pathology and non-elbow pathology patients’ estimated ROM. There was great disparity between patient-estimated and measured ROM, although estimates of patients with known elbow pathology did not demonstrate any significant difference from their healthy counterparts. These differences may be too great for patient-estimated range of motion to be used as a reliable tool for assessing outcomes.
- 3 February 2016
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 8 (2) , 118-123
Accuracy of patient-reported range of elbow motion
Patient-reported outcome meaures (PROMs) not only provide valuable insights into subjective indices of joint health, but also may provide limited objective information about range of motion (ROM). We sought to evaluate the accuracy of patient-reported range of elbow motion compared to measured ROM. Sixty clinic patients were recruited, of whom 26 had elbow pathologies and 34 had pathologies other than at the elbow joint. Each patient independently estimated ROM for extension, flexion, pronation and supination before this was measured by a clinician using a universal goniometer, with the mean being the gold standard. We found that patients’ ROM estimates were significantly different from measured ROM (p < 0.00001 at 95% confidence interval). There was no statistically significant difference between elbow pathology and non-elbow pathology patients’ estimated ROM. There was great disparity between patient-estimated and measured ROM, although estimates of patients with known elbow pathology did not demonstrate any significant difference from their healthy counterparts. These differences may be too great for patient-estimated range of motion to be used as a reliable tool for assessing outcomes.
- 1 May 2004
- Published by Taylor & Francis in International Journal of Food Sciences and Nutrition
- Vol. 55 (3) , 201-205
A pilot study of phytoestrogen content of soy foods and traditional Chinese medicines for women's health in Hong Kong
In view of the possible health benefits of phytoestrogens, a pilot study was carried out to quantitate the phytoestrogen content of soy foods and tea commonly consumed in Hong Kong, and also of traditional Chinese medicinal (TCM) products that are prescribed for menopausal symptoms and diseases relating to the menopause. Assays of daidzein and genistein were carried out using high-performance liquid chromatography, after extraction procedures. The TCM products were found to contain phytoestrogen in quantities comparable with soy products. Moreover, certain types of Chinese tea contained large quantities of phytoestrogens in the leaves, but also yielded comparable quantities in the infusion for drinking. The phytoestrogen content of these TCM may provide a scientific basis for their actions. However, clinical efficacy can only be determined by clinical trials.
- 1 May 2004
- Published by Taylor & Francis in International Journal of Food Sciences and Nutrition
- Vol. 55 (3) , 201-205
A pilot study of phytoestrogen content of soy foods and traditional Chinese medicines for women's health in Hong Kong
In view of the possible health benefits of phytoestrogens, a pilot study was carried out to quantitate the phytoestrogen content of soy foods and tea commonly consumed in Hong Kong, and also of traditional Chinese medicinal (TCM) products that are prescribed for menopausal symptoms and diseases relating to the menopause. Assays of daidzein and genistein were carried out using high-performance liquid chromatography, after extraction procedures. The TCM products were found to contain phytoestrogen in quantities comparable with soy products. Moreover, certain types of Chinese tea contained large quantities of phytoestrogens in the leaves, but also yielded comparable quantities in the infusion for drinking. The phytoestrogen content of these TCM may provide a scientific basis for their actions. However, clinical efficacy can only be determined by clinical trials.