ASAnne E. C. M. Saris

Anne E. C. M. Saris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anne E. C. M. Saris has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Chris L. de Korte

    Medical Ultrasound Imaging Center, Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands

    12 shared publications
  • Joosje M. K. de Bakker

    Department of Medical Imaging, Medical Ultrasound Imaging Center, Radboud University Medical Center, Nijmegen, The Netherlands

    6 shared publications
  • Maartje M. Nillesen

    Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands

    5 shared publications
  • Stein Fekkes

    Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, the Netherlands

    5 shared publications
  • Hendrik H. G. Hansen

    Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands

    3 shared publications
  • Jan Menssen

    Department of Medical Imaging, Medical Ultrasound Imaging Center, Radboud University Medical Center, Nijmegen, The Netherlands

    3 shared publications

Latest Publications

  • Open Access

    Cardiac adaptation in pediatric kidney transplant recipients with large donor–recipient size discrepancy: a speckle-tracking echocardiography study

    by Mark W. Schaars, Floris E. A. Udink Ten Cate, Elisabeth A. M. Cornelissen, Gert Weijers, Marieke Voet, Anne E. C. M. Saris

    Background: Pediatric living donor kidney transplantation (KT) with large donor-recipient size mismatch induces a large hemodynamic burden on the child recipient. Although successful KT is known to be beneficial for cardiac function and remodeling, its effects in small recipients with adult donors have not been evaluated. We aimed to describe left ventricular (LV) function and geometry using conventional and speckle-tracking echocardiography in this population. Methods: A prospective longitudinal study was performed. Living donor KT recipients with large donor-recipient size mismatch underwent conventional and speckle-tracking echocardiography prior to KT, shortly after KT and at 6 and 12 months post-transplantation. LV global longitudinal strain (GLS), LV ejection fraction, cardiac index, LV mass index (LVMi) and LV dimensions were obtained. Results: Ten patients were included with a median [IQR] age of 5.9 years [4.4–8.5]. The median donor–recipient body surface area ratio was 2.36. Prior to transplantation, LV systolic dysfunction was found in 80% of the patients (GLS −18.9% [−19.7–−18.7]). Significant improvement was found after 12 months (change in GLS −1.3% [−1.8–−0.9], p = 0.004). A significant reduction in LVMi was found at 6 months and 12 months of −8.9 g/m 2.7 [−15.6–−5.4], p = 0.01 and −14.3 g/m 2.7 [−15.3–−12.9], p = 0.004, respectively. No significant changes in cardiac index were found at 6 and 12 months. Conclusions: Despite the increased hemodynamic demands after pediatric KT with large donor-recipient size mismatch, improved LV function and reduced left ventricular mass were found within 1 year after transplantation. These results suggest reversed cardiac remodeling.

  • Open Access

    Blood flow characteristics in the femoral bifurcation of healthy subjects

    by Majorie van Helvert, Janna Ruisch, Joosje M.K. de Bakker, Anne E.C.M. Saris, Chris L. de Korte, Michel Versluis, Erik Groot Jebbink, Michel M.P.J. Reijnen


  • Open Access

    The Added Value of Cascaded Plane Wave Imaging for Autocorrelation- and Cross-Correlation-Based Velocity Vector Imaging

    by Joosje M. K. De Bakker, Ingvild K. Ekroll, Anne E. C. M. Saris, Jørgen Avdal

    Velocity vector imaging (VVI) can suffer from poor signal-to-noise (SNR) conditions, eventually restricting the estimation of velocities at low SNRs. Cascaded dual-polarity wave (CDW) imaging has been shown to enhance blood-SNR, thereby improving cross-correlation-based VVI. However, the CDW decoding process is sensitive to motion, where imperfect summation and cancellation of pulses can lead to reduced amplitude gain and ghost pulses outside the main pulse. Multi/dual-angle transmits, combined with either autocorrelation- or cross-correlation-based axial velocity estimation, are commonly used for VVI. Both techniques have intrinsic limitations, such as speckle decorrelation and aliasing, and strengths, where autocorrelation is known to be more resistant to noise and cross-correlation results in more accurate estimates in high SNR conditions. This study evaluates the benefits of CDW imaging for both autocorrelation- and cross-correlation-based VVI using the FLUST simulation toolbox and experiments, including parabolic and rotational flow scenarios. The results indicate that autocorrelation performs consistently across the entire SNR range, while cross-correlation is more accurate and precise in high SNR conditions. CDW improves estimation performance in low SNR conditions, particularly for estimation of low velocities, with a more substantial performance boost for cross-correlation compared to autocorrelation. In general, CDW imaging shows to be beneficial for VVI, independent of the used velocity estimator.

  • Open Access

    Cascaded Plane Wave Ultrasound Velocity Vector Imaging: In Vivo Feasibility in Carotid Arteries

    by Joosje M. K. de Bakker, Janna Ruisch, Chris L. de Korte, Anne E. C. M. Saris

    Cascaded Dual-Polarity Wave (CDW) imaging enhances signal-to-noise ratio (SNR) by transmitting polarity-alternating pulse sequences, followed by decoding to reinforce coherent signals. This study assesses the in vivo feasibility of CDW for velocity vector imaging (VVI) in the carotid artery, compared to conventional single-pulse plane wave imaging (cPW). Two decoding strategies were evaluated: frequency-domain decoding (F-CDW), offering moderate SNR improvement with reduced motion sensitivity, and time-domain decoding (T-CDW), providing higher SNR gains but larger motion sensitivity. cPW imaging was performed using constant gain (cPW-CG), set patient-specific to avoid clipping, and maximum gain (cPW-HG). VVI using CDW and cPW imaging was obtained in twenty carotid arteries, including ten hemodynamic significant stenoses. A comparison was made based on SNR, percentage of reliable velocity estimates, and agreement with conventional pulsed wave Doppler. Results showed improved SNR and reliability using CDW compared to cPW-CG. The median SNR at peak systole increased from 0.9 dB (cPW-CG) to 2.8 dB (F-CDW) and 4.7 dB (T-CDW). T-CDW showed the greatest improvement, even outperforming cPW-HG (SNR = 1.2 dB) based on SNR and reliability. All methods showed similar agreement with pulsed wave Doppler. Although CDW demonstrated clear benefits, its full potential was limited by restricted gain settings to prevent clipping. CDW is particularly promising for imaging deeper-located carotid arteries, where higher gains can be applied to further enhance SNR beyond conventional plane wave techniques.


  • Open Access

    Frequency-Domain Decoding of Cascaded Dual- Polarity Waves for Ultrafast Ultrasound Imaging

    by Charlotte L. Nawijn, Joosje M. K. de Bakker, Tim Segers, Chris L. de Korte, Michel Versluis, Anne E. C. M. Saris, Guillaume Lajoinie

    Ultrafast plane-wave ultrasound imaging is a versatile tool which has become increasingly relevant for blood flow imaging using speckle tracking, but suffers from a low signal-to-noise ratio (SNR). Cascaded dual-polarity waves (CDW) imaging can improve the SNR by transmitting pulse trains, which are subsequently decoded to recover the imaging resolution. However, the current decoding method (in the time domain) requires a set of two acquisitions, which introduces motion artifacts that result in incorrect speckle tracking at high flow velocities. Here, we evaluate an inverse filtering approach which uses frequency-domain decoding to decode acquisitions independently. Experiments using a disk phantom show that frequency-domain decoding of a four-pulse train achieves an SNR gain of up to 4.2 dB, versus 5.9 dB for conventional decoding. The benefit of frequency-domain decoding for flow quantification is assessed through experiments performed with a rotating disk phantom and a parabolic flow, and through matching linear simulations. Both CDW methods improve the tracking accuracy compared to single plane-wave imaging. Time-domain decoding outperforms frequency-domain decoding in low SNR conditions and low velocities (≤0.25 m/s), as a result of the higher SNR gain. In contrast, frequency-domain decoding outperforms time-domain decoding for high peak velocities in imaging of the rotating disk (1 m/s) and of the parabolic flow (2 m/s), when significant scatterer motion between acquisitions causes imperfect time-domain decoding. Its ability to decode individual acquisitions makes the used frequency-domain decoding of CDW a promising approach to improve the SNR and thereby the accuracy of flow quantification at high velocities.


  • Open Access

    Quantification of Blood Flow in the Carotid Bifurcation of Healthy Subjects

    by Janna Ruisch, Joosje M. K. de Bakker, Majorie van Helvert, Erik Groot Jebbink, Suzanne Holewijn, Michel M. P. J. Reijnen, Chris L. de Korte, Anne E. C. M. Saris

    Locally disturbed blood flow patterns are known to create an atherogenic environment, in particularly in the presence of other cardiovascular risk factors. Given the geometry of a healthy carotid artery, complex flow patterns are expected to be present. This study aims to characterize (complex) blood flow patterns and estimate flow-derived parameters in the carotid bifurcation of healthy subjects. Ultrasound-based velocity vector imaging (US-VVI) was acquired in the carotid bifurcation of twenty healthy subjects. Hemodynamic parameters, including temporal velocity profile, vector complexity, vortex presence and wall shear stress, were derived and compared between two age groups (20-30 and 65-75 years). Lower velocities and higher vector complexity values were observed in the older age group for all timepoints. The highest presence of vortices was observed during the systolic deceleration, which was more exposed in younger subjects (5 out of 10) compared to older subjects (3 out of 9). A quick build-up and consequent resolving of the vortices was reflected by the relatively short vortex duration, with a vortex presence of 11.4% (7.9-15.6) and 13.1% (5.9-18.6) as percentage of the cardiac cycle in younger and older subjects, respectively. Larger WSS estimates, represented as median along the complete vessel wall, were found in the younger subjects at all timestamps, except at systolic deceleration. In conclusion, the presence of complex flow patterns was confirmed in healthy subjects and multiple flow-derived hemodynamic parameters were evaluated in two age groups, providing an insight into age-related differences in hemodynamics. Aging seemed to result in higher vector complexities, whereas the presence of recirculating flow is less in older subjects.


  • Simultaneous Coherent and Displacement Compounding for 2-D Noninvasive Carotid Strain Imaging: A Proof of Principle Study

    by Moein Mozaffarzadeh, Anne E. C. M. Saris, Jan Menssen, Chris L. de Korte

    Arteriosclerosis results from lipid buildup in artery walls, leading to plaque formation, and is a leading cause of death. Plaque rupture can cause blood clots that might lead to a stroke. Distinguishing plaque types is a challenge, but ultrasound elastography can help by assessing plaque composition based on strain values. Since the artery has a circular structure, an accurate axial and lateral displacement strategy is needed to derive the radial and circumferential strains. A high precision lateral displacement is challenging due to the lack of phase information in the lateral direction of the beamformed RF data. Previously, our group has developed a compounding technique in which the lateral displacement is estimated using tri-angulation of the axial displacement estimated from transmitting and beamforming ultrasound beams at ±20°. However, transmitting with a single plane wave will reduce signal-to-noise and contrast-to-noise ratio as well as lateral resolution. In this paper, we combine our displacement compounding with coherent compounding. Instead of transmitting a single plane wave, multiple plane waves are transmitted at certain angles centered on the angle of the beamforming grids, and then the backscattered wavefronts are beamformed and coherently compounded on the center of the transmit beams (-20°, +20° and 0°). The numerical investigation using the GE9LD probe (f 0 = 5.32 MHz, pitch = 230 μm, width = 43.9 mm) led us to 19 plane waves spanning angles within -10° to 10° (with respect to center of the transmit beams); resulting in a total of 57 plane wave transmit (for 3 beamforming grids at 0° and ±20°). FIELD II simulations of a cylindrically-shaped phantom (mimicking the carotid artery) at a signal-to-noise ratio ≥ 20 dB shows that the proposed method decreases the root-mean-square-error of the lateral displacement and strain estimations by 40% and 45% compared to the previous method, respectively. The results of our experiments with a carotid artery phantom (made out of 10% PVA) show that the proposed method provides strain images with a higher quality and more in agreement with the theory, with 26% lower standard deviation, specially at the peak systolic phase. The proposed method paves the path toward improved quality in vivo 2D strain imaging using our displacement compounding technique and translating it to 3D with a row-column array.


  • Open Access

    Cascaded Plane Wave Ultrasound for Blood Velocity Vector Imaging in the Carotid Artery

    by Joosje M. K. De Bakker, Chris L. De Korte, Anne E. C. M. Saris

    Cascaded dual-polarity waves (CDWs) imaging increases the signal-to-noise ratio (SNR) by transmitting trains of pulses with different polarity order, which are combined via decoding afterward. This potentially enables velocity vector imaging (VVI) in more challenging SNR conditions. However, the motion of blood in between the trains will influence the decoding process. In this work, the use of CDW for blood VVI is evaluated for the first time. Dual-angle, plane wave (PW) ultrasound, CDW-coded, and noncoded conventional PW (cPW), was acquired using a 7.8 MHz linear array at a pulse repetition frequency (PRF) of 8 kHz. CDW-channel data were decoded prior to beamforming and cross correlation-based compound speckle tracking for VVI. Simulations of single scatterer motion show a high dependence of amplitude gain on the velocity magnitude and direction for CDW-coded transmissions. Both simulations and experiments of parabolic flow show increased SNRs for CDW imaging. As a result, CDW outperforms cPW VVI in low SNR conditions, based on both bias and standard deviation (SD). Quantitative linear regression and qualitative analyses of simulated realistic carotid artery blood flow show a similar performance of CDW and cPW for high SNR (14 dB) conditions. However, reducing the SNR to 6 dB, results in a root-mean-squared error $2.7\times $ larger for cPW versus CDW, and an ${R}^{{2}}$ of 0.4 versus 0.9. Initial in vivo evaluation of a healthy carotid artery shows increased SNR and more reliable velocity estimates for CDW versus cPW. In conclusion, this work demonstrates that CDW imaging facilitates improved VVI of deeper located carotid arteries.


  • In Vivo Blood Velocity Vector Imaging Using Adaptive Velocity Compounding in the Carotid Artery Bifurcation

    by Anne E.C.M. Saris, Hendrik H.G. Hansen, Stein Fekkes, Jan Menssen, Maartje M. Nillesen, Chris L. de Korte


  • Simultaneous Vascular Strain and Blood Vector Velocity Imaging Using High-Frequency Versus Conventional-Frequency Plane Wave Ultrasound: A Phantom Study

    by Stein Fekkes, Anne E. C. M. Saris, Maartje M. Nillesen, Jan Menssen, Hendrik H. G. Hansen, Chris L. de Korte

    Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.