Joosje M. K. de Bakker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joosje M. K. de Bakker has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anne E. C. M. Saris
Department of Medical Imaging, Medical Ultrasound Imaging Center, Radboud University Medical Center, Nijmegen, The Netherlands
6 shared publications - Chris L. de Korte
Medical Ultrasound Imaging Center, Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
4 shared publications - Janna Ruisch
Department of Medical Imaging, Medical Ultrasound Imaging Center, Radboud University Medical Center, Nijmegen, The Netherlands
2 shared publications Majorie van Helvert
2 shared publications- Michel M. P. J. Reijnen
Department of Surgery, Rijnstate Hospital, Arnhem, the Netherlands
2 shared publications - Charlotte L. Nawijn
Physics of Fluids group, Technical Medical (TechMed) Center, Max Planck Center Twente for Complex Fluid Dynamics, University of Twente 1 , Enschede
1 shared publication
Latest Publications
- Open Access
- 26 May 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Blood flow characteristics in the femoral bifurcation of healthy subjects
- 26 May 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Open AccessBlood flow characteristics in the femoral bifurcation of healthy subjects
- Open Access
- 2 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 281-285
The Added Value of Cascaded Plane Wave Imaging for Autocorrelation- and Cross-Correlation-Based Velocity Vector Imaging
Velocity vector imaging (VVI) can suffer from poor signal-to-noise (SNR) conditions, eventually restricting the estimation of velocities at low SNRs. Cascaded dual-polarity wave (CDW) imaging has been shown to enhance blood-SNR, thereby improving cross-correlation-based VVI. However, the CDW decoding process is sensitive to motion, where imperfect summation and cancellation of pulses can lead to reduced amplitude gain and ghost pulses outside the main pulse. Multi/dual-angle transmits, combined with either autocorrelation- or cross-correlation-based axial velocity estimation, are commonly used for VVI. Both techniques have intrinsic limitations, such as speckle decorrelation and aliasing, and strengths, where autocorrelation is known to be more resistant to noise and cross-correlation results in more accurate estimates in high SNR conditions. This study evaluates the benefits of CDW imaging for both autocorrelation- and cross-correlation-based VVI using the FLUST simulation toolbox and experiments, including parabolic and rotational flow scenarios. The results indicate that autocorrelation performs consistently across the entire SNR range, while cross-correlation is more accurate and precise in high SNR conditions. CDW improves estimation performance in low SNR conditions, particularly for estimation of low velocities, with a more substantial performance boost for cross-correlation compared to autocorrelation. In general, CDW imaging shows to be beneficial for VVI, independent of the used velocity estimator.
- 2 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 281-285
Open AccessThe Added Value of Cascaded Plane Wave Imaging for Autocorrelation- and Cross-Correlation-Based Velocity Vector Imaging
Velocity vector imaging (VVI) can suffer from poor signal-to-noise (SNR) conditions, eventually restricting the estimation of velocities at low SNRs. Cascaded dual-polarity wave (CDW) imaging has been shown to enhance blood-SNR, thereby improving cross-correlation-based VVI. However, the CDW decoding process is sensitive to motion, where imperfect summation and cancellation of pulses can lead to reduced amplitude gain and ghost pulses outside the main pulse. Multi/dual-angle transmits, combined with either autocorrelation- or cross-correlation-based axial velocity estimation, are commonly used for VVI. Both techniques have intrinsic limitations, such as speckle decorrelation and aliasing, and strengths, where autocorrelation is known to be more resistant to noise and cross-correlation results in more accurate estimates in high SNR conditions. This study evaluates the benefits of CDW imaging for both autocorrelation- and cross-correlation-based VVI using the FLUST simulation toolbox and experiments, including parabolic and rotational flow scenarios. The results indicate that autocorrelation performs consistently across the entire SNR range, while cross-correlation is more accurate and precise in high SNR conditions. CDW improves estimation performance in low SNR conditions, particularly for estimation of low velocities, with a more substantial performance boost for cross-correlation compared to autocorrelation. In general, CDW imaging shows to be beneficial for VVI, independent of the used velocity estimator.
- Open Access
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (12) , 1607-1617
Cascaded Plane Wave Ultrasound Velocity Vector Imaging: In Vivo Feasibility in Carotid Arteries
Cascaded Dual-Polarity Wave (CDW) imaging enhances signal-to-noise ratio (SNR) by transmitting polarity-alternating pulse sequences, followed by decoding to reinforce coherent signals. This study assesses the in vivo feasibility of CDW for velocity vector imaging (VVI) in the carotid artery, compared to conventional single-pulse plane wave imaging (cPW). Two decoding strategies were evaluated: frequency-domain decoding (F-CDW), offering moderate SNR improvement with reduced motion sensitivity, and time-domain decoding (T-CDW), providing higher SNR gains but larger motion sensitivity. cPW imaging was performed using constant gain (cPW-CG), set patient-specific to avoid clipping, and maximum gain (cPW-HG). VVI using CDW and cPW imaging was obtained in twenty carotid arteries, including ten hemodynamic significant stenoses. A comparison was made based on SNR, percentage of reliable velocity estimates, and agreement with conventional pulsed wave Doppler. Results showed improved SNR and reliability using CDW compared to cPW-CG. The median SNR at peak systole increased from 0.9 dB (cPW-CG) to 2.8 dB (F-CDW) and 4.7 dB (T-CDW). T-CDW showed the greatest improvement, even outperforming cPW-HG (SNR = 1.2 dB) based on SNR and reliability. All methods showed similar agreement with pulsed wave Doppler. Although CDW demonstrated clear benefits, its full potential was limited by restricted gain settings to prevent clipping. CDW is particularly promising for imaging deeper-located carotid arteries, where higher gains can be applied to further enhance SNR beyond conventional plane wave techniques.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (12) , 1607-1617
Open AccessCascaded Plane Wave Ultrasound Velocity Vector Imaging: In Vivo Feasibility in Carotid Arteries
Cascaded Dual-Polarity Wave (CDW) imaging enhances signal-to-noise ratio (SNR) by transmitting polarity-alternating pulse sequences, followed by decoding to reinforce coherent signals. This study assesses the in vivo feasibility of CDW for velocity vector imaging (VVI) in the carotid artery, compared to conventional single-pulse plane wave imaging (cPW). Two decoding strategies were evaluated: frequency-domain decoding (F-CDW), offering moderate SNR improvement with reduced motion sensitivity, and time-domain decoding (T-CDW), providing higher SNR gains but larger motion sensitivity. cPW imaging was performed using constant gain (cPW-CG), set patient-specific to avoid clipping, and maximum gain (cPW-HG). VVI using CDW and cPW imaging was obtained in twenty carotid arteries, including ten hemodynamic significant stenoses. A comparison was made based on SNR, percentage of reliable velocity estimates, and agreement with conventional pulsed wave Doppler. Results showed improved SNR and reliability using CDW compared to cPW-CG. The median SNR at peak systole increased from 0.9 dB (cPW-CG) to 2.8 dB (F-CDW) and 4.7 dB (T-CDW). T-CDW showed the greatest improvement, even outperforming cPW-HG (SNR = 1.2 dB) based on SNR and reliability. All methods showed similar agreement with pulsed wave Doppler. Although CDW demonstrated clear benefits, its full potential was limited by restricted gain settings to prevent clipping. CDW is particularly promising for imaging deeper-located carotid arteries, where higher gains can be applied to further enhance SNR beyond conventional plane wave techniques.
- Open Access
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 321-337
Frequency-Domain Decoding of Cascaded Dual- Polarity Waves for Ultrafast Ultrasound Imaging
Ultrafast plane-wave ultrasound imaging is a versatile tool which has become increasingly relevant for blood flow imaging using speckle tracking, but suffers from a low signal-to-noise ratio (SNR). Cascaded dual-polarity waves (CDW) imaging can improve the SNR by transmitting pulse trains, which are subsequently decoded to recover the imaging resolution. However, the current decoding method (in the time domain) requires a set of two acquisitions, which introduces motion artifacts that result in incorrect speckle tracking at high flow velocities. Here, we evaluate an inverse filtering approach which uses frequency-domain decoding to decode acquisitions independently. Experiments using a disk phantom show that frequency-domain decoding of a four-pulse train achieves an SNR gain of up to 4.2 dB, versus 5.9 dB for conventional decoding. The benefit of frequency-domain decoding for flow quantification is assessed through experiments performed with a rotating disk phantom and a parabolic flow, and through matching linear simulations. Both CDW methods improve the tracking accuracy compared to single plane-wave imaging. Time-domain decoding outperforms frequency-domain decoding in low SNR conditions and low velocities (≤0.25 m/s), as a result of the higher SNR gain. In contrast, frequency-domain decoding outperforms time-domain decoding for high peak velocities in imaging of the rotating disk (1 m/s) and of the parabolic flow (2 m/s), when significant scatterer motion between acquisitions causes imperfect time-domain decoding. Its ability to decode individual acquisitions makes the used frequency-domain decoding of CDW a promising approach to improve the SNR and thereby the accuracy of flow quantification at high velocities.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 321-337
Open AccessFrequency-Domain Decoding of Cascaded Dual- Polarity Waves for Ultrafast Ultrasound Imaging
Ultrafast plane-wave ultrasound imaging is a versatile tool which has become increasingly relevant for blood flow imaging using speckle tracking, but suffers from a low signal-to-noise ratio (SNR). Cascaded dual-polarity waves (CDW) imaging can improve the SNR by transmitting pulse trains, which are subsequently decoded to recover the imaging resolution. However, the current decoding method (in the time domain) requires a set of two acquisitions, which introduces motion artifacts that result in incorrect speckle tracking at high flow velocities. Here, we evaluate an inverse filtering approach which uses frequency-domain decoding to decode acquisitions independently. Experiments using a disk phantom show that frequency-domain decoding of a four-pulse train achieves an SNR gain of up to 4.2 dB, versus 5.9 dB for conventional decoding. The benefit of frequency-domain decoding for flow quantification is assessed through experiments performed with a rotating disk phantom and a parabolic flow, and through matching linear simulations. Both CDW methods improve the tracking accuracy compared to single plane-wave imaging. Time-domain decoding outperforms frequency-domain decoding in low SNR conditions and low velocities (≤0.25 m/s), as a result of the higher SNR gain. In contrast, frequency-domain decoding outperforms time-domain decoding for high peak velocities in imaging of the rotating disk (1 m/s) and of the parabolic flow (2 m/s), when significant scatterer motion between acquisitions causes imperfect time-domain decoding. Its ability to decode individual acquisitions makes the used frequency-domain decoding of CDW a promising approach to improve the SNR and thereby the accuracy of flow quantification at high velocities.
- Open Access
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 309-320
Quantification of Blood Flow in the Carotid Bifurcation of Healthy Subjects
Locally disturbed blood flow patterns are known to create an atherogenic environment, in particularly in the presence of other cardiovascular risk factors. Given the geometry of a healthy carotid artery, complex flow patterns are expected to be present. This study aims to characterize (complex) blood flow patterns and estimate flow-derived parameters in the carotid bifurcation of healthy subjects. Ultrasound-based velocity vector imaging (US-VVI) was acquired in the carotid bifurcation of twenty healthy subjects. Hemodynamic parameters, including temporal velocity profile, vector complexity, vortex presence and wall shear stress, were derived and compared between two age groups (20-30 and 65-75 years). Lower velocities and higher vector complexity values were observed in the older age group for all timepoints. The highest presence of vortices was observed during the systolic deceleration, which was more exposed in younger subjects (5 out of 10) compared to older subjects (3 out of 9). A quick build-up and consequent resolving of the vortices was reflected by the relatively short vortex duration, with a vortex presence of 11.4% (7.9-15.6) and 13.1% (5.9-18.6) as percentage of the cardiac cycle in younger and older subjects, respectively. Larger WSS estimates, represented as median along the complete vessel wall, were found in the younger subjects at all timestamps, except at systolic deceleration. In conclusion, the presence of complex flow patterns was confirmed in healthy subjects and multiple flow-derived hemodynamic parameters were evaluated in two age groups, providing an insight into age-related differences in hemodynamics. Aging seemed to result in higher vector complexities, whereas the presence of recirculating flow is less in older subjects.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 309-320
Open AccessQuantification of Blood Flow in the Carotid Bifurcation of Healthy Subjects
Locally disturbed blood flow patterns are known to create an atherogenic environment, in particularly in the presence of other cardiovascular risk factors. Given the geometry of a healthy carotid artery, complex flow patterns are expected to be present. This study aims to characterize (complex) blood flow patterns and estimate flow-derived parameters in the carotid bifurcation of healthy subjects. Ultrasound-based velocity vector imaging (US-VVI) was acquired in the carotid bifurcation of twenty healthy subjects. Hemodynamic parameters, including temporal velocity profile, vector complexity, vortex presence and wall shear stress, were derived and compared between two age groups (20-30 and 65-75 years). Lower velocities and higher vector complexity values were observed in the older age group for all timepoints. The highest presence of vortices was observed during the systolic deceleration, which was more exposed in younger subjects (5 out of 10) compared to older subjects (3 out of 9). A quick build-up and consequent resolving of the vortices was reflected by the relatively short vortex duration, with a vortex presence of 11.4% (7.9-15.6) and 13.1% (5.9-18.6) as percentage of the cardiac cycle in younger and older subjects, respectively. Larger WSS estimates, represented as median along the complete vessel wall, were found in the younger subjects at all timestamps, except at systolic deceleration. In conclusion, the presence of complex flow patterns was confirmed in healthy subjects and multiple flow-derived hemodynamic parameters were evaluated in two age groups, providing an insight into age-related differences in hemodynamics. Aging seemed to result in higher vector complexities, whereas the presence of recirculating flow is less in older subjects.
- Open Access
- 18 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 366-379
Cascaded Plane Wave Ultrasound for Blood Velocity Vector Imaging in the Carotid Artery
Cascaded dual-polarity waves (CDWs) imaging increases the signal-to-noise ratio (SNR) by transmitting trains of pulses with different polarity order, which are combined via decoding afterward. This potentially enables velocity vector imaging (VVI) in more challenging SNR conditions. However, the motion of blood in between the trains will influence the decoding process. In this work, the use of CDW for blood VVI is evaluated for the first time. Dual-angle, plane wave (PW) ultrasound, CDW-coded, and noncoded conventional PW (cPW), was acquired using a 7.8 MHz linear array at a pulse repetition frequency (PRF) of 8 kHz. CDW-channel data were decoded prior to beamforming and cross correlation-based compound speckle tracking for VVI. Simulations of single scatterer motion show a high dependence of amplitude gain on the velocity magnitude and direction for CDW-coded transmissions. Both simulations and experiments of parabolic flow show increased SNRs for CDW imaging. As a result, CDW outperforms cPW VVI in low SNR conditions, based on both bias and standard deviation (SD). Quantitative linear regression and qualitative analyses of simulated realistic carotid artery blood flow show a similar performance of CDW and cPW for high SNR (14 dB) conditions. However, reducing the SNR to 6 dB, results in a root-mean-squared error$2.7\times $ larger for cPW versus CDW, and an${R}^{{2}}$ of 0.4 versus 0.9. Initial in vivo evaluation of a healthy carotid artery shows increased SNR and more reliable velocity estimates for CDW versus cPW. In conclusion, this work demonstrates that CDW imaging facilitates improved VVI of deeper located carotid arteries.- 18 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 366-379
Open AccessCascaded Plane Wave Ultrasound for Blood Velocity Vector Imaging in the Carotid Artery
Cascaded dual-polarity waves (CDWs) imaging increases the signal-to-noise ratio (SNR) by transmitting trains of pulses with different polarity order, which are combined via decoding afterward. This potentially enables velocity vector imaging (VVI) in more challenging SNR conditions. However, the motion of blood in between the trains will influence the decoding process. In this work, the use of CDW for blood VVI is evaluated for the first time. Dual-angle, plane wave (PW) ultrasound, CDW-coded, and noncoded conventional PW (cPW), was acquired using a 7.8 MHz linear array at a pulse repetition frequency (PRF) of 8 kHz. CDW-channel data were decoded prior to beamforming and cross correlation-based compound speckle tracking for VVI. Simulations of single scatterer motion show a high dependence of amplitude gain on the velocity magnitude and direction for CDW-coded transmissions. Both simulations and experiments of parabolic flow show increased SNRs for CDW imaging. As a result, CDW outperforms cPW VVI in low SNR conditions, based on both bias and standard deviation (SD). Quantitative linear regression and qualitative analyses of simulated realistic carotid artery blood flow show a similar performance of CDW and cPW for high SNR (14 dB) conditions. However, reducing the SNR to 6 dB, results in a root-mean-squared error$2.7\times $ larger for cPW versus CDW, and an${R}^{{2}}$ of 0.4 versus 0.9. Initial in vivo evaluation of a healthy carotid artery shows increased SNR and more reliable velocity estimates for CDW versus cPW. In conclusion, this work demonstrates that CDW imaging facilitates improved VVI of deeper located carotid arteries.