Fu-Jen Kao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fu-Jen Kao has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Nirmal Mazumder
Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, India
10 shared publications - Ankur Gogoi
Jagannath Barooah University
7 shared publications - Subir Das
Department of Chemistry University of Zurich Winterthurerstrasse 190 Zurich 8057 Switzerland
5 shared publications - Guan-Yu Zhuo
Institute of Biophotonics, College of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
4 shared publications Jianjun Qiu
Institute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan
4 shared publications- Carlos Macias-Romero
Laboratory of Fundamental Biophotonics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
3 shared publications
Latest Publications
- Open Access
- 17 May 2024
- Published by IOP Publishing in Laser Physics Letters
- Vol. 21 (6) , 065701
Photon counting based pump-probe technique for quantitative characterization of fluorescence in a lock-in free detection manner
The stimulated emission (SE) signal in pump-probe experiment is conventionally measured with lock-in detection to differentiate the weak signals from the relatively large background of spontaneous emission and probe beam. Therefore, direct characterization of signal strength are often major limiting factors in terms of noise, speed, and data acquisition. In contrast, photon counting allows direct quantification of signal strength, while synchronized pump-probe pulse enables precise timing and the separation of signals accordingly. Herein, the SE based pump-probe method is combined with time-correlated single-photon counting to investigate the ultrafast photochemical parameters, digitally and quantitatively. As a proof-of-concept, our technique is applied to investigate, fluorescence lifetime ( τ ) ∼ 3.71 ns , optical absorption cross-section ( σ abs ) ∼ 1.23 × 10 − 16 c m 2 , and the SE cross-section ( σ SE ) ∼ 2.22 × 10 − 17 c m 2 , of a fluorescent dye (ATTO 647N) quantitatively. The experimental results are also compared with theoretical photon statistics to further justify the advantages including experimental and statistical critical molecular dynamics parameters extraction with excellent high accuracy.
- 17 May 2024
- Published by IOP Publishing in Laser Physics Letters
- Vol. 21 (6) , 065701
Open AccessPhoton counting based pump-probe technique for quantitative characterization of fluorescence in a lock-in free detection manner
The stimulated emission (SE) signal in pump-probe experiment is conventionally measured with lock-in detection to differentiate the weak signals from the relatively large background of spontaneous emission and probe beam. Therefore, direct characterization of signal strength are often major limiting factors in terms of noise, speed, and data acquisition. In contrast, photon counting allows direct quantification of signal strength, while synchronized pump-probe pulse enables precise timing and the separation of signals accordingly. Herein, the SE based pump-probe method is combined with time-correlated single-photon counting to investigate the ultrafast photochemical parameters, digitally and quantitatively. As a proof-of-concept, our technique is applied to investigate, fluorescence lifetime ( τ ) ∼ 3.71 ns , optical absorption cross-section ( σ abs ) ∼ 1.23 × 10 − 16 c m 2 , and the SE cross-section ( σ SE ) ∼ 2.22 × 10 − 17 c m 2 , of a fluorescent dye (ATTO 647N) quantitatively. The experimental results are also compared with theoretical photon statistics to further justify the advantages including experimental and statistical critical molecular dynamics parameters extraction with excellent high accuracy.
- Open Access
- 30 April 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026107
Investigating cartilage-related diseases by polarization-resolved second harmonic generation (P-SHG) imaging
Establishing quantitative parameters for differentiating between healthy and diseased cartilage tissues by examining collagen fibril degradation patterns facilitates the understanding of tissue characteristics during disease progression. These findings could also complement existing clinical methods used to diagnose cartilage-related diseases. In this study, cartilage samples from normal, osteoarthritis (OA), and rheumatoid arthritis (RA) tissues were prepared and analyzed using polarization-resolved second harmonic generation (P-SHG) imaging and quantitative image texture analysis. The enhanced molecular contrast obtained from this approach is expected to aid in distinguishing between healthy and diseased cartilage tissues. P-SHG image analysis revealed distinct parameters in the cartilage samples, reflecting variations in collagen fibril arrangement and organization across different pathological states. Normal tissues exhibited distinct χ33/χ31 values compared with those of OA and RA, indicating collagen type transition and cartilage erosion with chondrocyte swelling, respectively. Compared with those of normal tissues, OA samples demonstrated a higher degree of linear polarization, suggesting increased tissue birefringence due to the deposition of type-I collagen in the extracellular matrix. The distribution of the planar orientation of collagen fibrils revealed a more directional orientation in the OA samples, associated with increased type-I collagen, while the RA samples exhibited a heterogeneous molecular orientation. This study revealed that the imaging technique, the quantitative analysis of the images, and the derived parameters presented in this study could be used as a reference for disease diagnostics, providing a clear understanding of collagen fibril degradation in cartilage.
- 30 April 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026107
Open AccessInvestigating cartilage-related diseases by polarization-resolved second harmonic generation (P-SHG) imaging
Establishing quantitative parameters for differentiating between healthy and diseased cartilage tissues by examining collagen fibril degradation patterns facilitates the understanding of tissue characteristics during disease progression. These findings could also complement existing clinical methods used to diagnose cartilage-related diseases. In this study, cartilage samples from normal, osteoarthritis (OA), and rheumatoid arthritis (RA) tissues were prepared and analyzed using polarization-resolved second harmonic generation (P-SHG) imaging and quantitative image texture analysis. The enhanced molecular contrast obtained from this approach is expected to aid in distinguishing between healthy and diseased cartilage tissues. P-SHG image analysis revealed distinct parameters in the cartilage samples, reflecting variations in collagen fibril arrangement and organization across different pathological states. Normal tissues exhibited distinct χ33/χ31 values compared with those of OA and RA, indicating collagen type transition and cartilage erosion with chondrocyte swelling, respectively. Compared with those of normal tissues, OA samples demonstrated a higher degree of linear polarization, suggesting increased tissue birefringence due to the deposition of type-I collagen in the extracellular matrix. The distribution of the planar orientation of collagen fibrils revealed a more directional orientation in the OA samples, associated with increased type-I collagen, while the RA samples exhibited a heterogeneous molecular orientation. This study revealed that the imaging technique, the quantitative analysis of the images, and the derived parameters presented in this study could be used as a reference for disease diagnostics, providing a clear understanding of collagen fibril degradation in cartilage.
- Open Access
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-5
Facile Construction of a Laser Scanning Optical Beam Induced Current Microscope
We report on the design and construction of a laser scanning optical beam-induced current (OBIC) microscope by assembling cost-effective commercial optical and electronic hardware components and developing data acquisition and control software in LabVIEW. A preliminary OBIC image of a Si photodetector acquired by the developed microscope is presented to demonstrate its operational capability. The versatility of the design will allow for the construction of other scanning microscope modalities on the same platform.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-5
Open AccessFacile Construction of a Laser Scanning Optical Beam Induced Current Microscope
We report on the design and construction of a laser scanning optical beam-induced current (OBIC) microscope by assembling cost-effective commercial optical and electronic hardware components and developing data acquisition and control software in LabVIEW. A preliminary OBIC image of a Si photodetector acquired by the developed microscope is presented to demonstrate its operational capability. The versatility of the design will allow for the construction of other scanning microscope modalities on the same platform.
- 25 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (13)
Calibrated χ(2)-tensor polarization-resolved second harmonic generation microscopy for precise tissue imaging
Polarization-resolved second harmonic generation (P-SHG) microscopy is commonly used to analyze the second-order susceptibility, χ(2), tensor, which enables the calculation of the molecular structure of harmonophores. However, despite extensive research on type I collagen, the measured χ(2) ratios vary considerably among published values, which raises the question of whether P-SHG imaging is universally applicable to all tissues containing harmonophores. In this work, we propose that the deviation of χ(2) ratios is primarily due to ignoring the molecular tilt angle and chirality in image analysis. To confirm our hypothesis, we present an analytical model based on C6 symmetry that takes into account these two factors. We also introduce an imaging scheme that splits SHG into X- and Y-polarized image components for χ(2) tensor analysis. Our approach effectively improves the precision of determining χ(2) ratios, depending on how much the two factors affect the P-SHG signals.
- 25 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (13)
Calibrated χ(2)-tensor polarization-resolved second harmonic generation microscopy for precise tissue imaging
Polarization-resolved second harmonic generation (P-SHG) microscopy is commonly used to analyze the second-order susceptibility, χ(2), tensor, which enables the calculation of the molecular structure of harmonophores. However, despite extensive research on type I collagen, the measured χ(2) ratios vary considerably among published values, which raises the question of whether P-SHG imaging is universally applicable to all tissues containing harmonophores. In this work, we propose that the deviation of χ(2) ratios is primarily due to ignoring the molecular tilt angle and chirality in image analysis. To confirm our hypothesis, we present an analytical model based on C6 symmetry that takes into account these two factors. We also introduce an imaging scheme that splits SHG into X- and Y-polarized image components for χ(2) tensor analysis. Our approach effectively improves the precision of determining χ(2) ratios, depending on how much the two factors affect the P-SHG signals.
- 9 May 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (30) , 305105
Charge relaxation associated with photon-induced deactivation of various traps in MAPbI3 films
Photon-induced deactivation of traps in MAPbI3 can strongly affect charge relaxation behavior. Charge relaxation associated with photo-induced deactivation of various traps in MAPbI3 films was investigated through steady-state and time-resolved photoluminescence (PL) spectroscopy under laser excitation at 635 and 430 nm to investigate the properties of the traps. Three types of traps that could be deactivated by photons were observed in the MAPbI3 films, namely TL, TH, and TGB. TL and TH, which were related to MAPbI3 bulk, had low and high photon energy thresholds (red and blue photons) for deactivation, respectively. TGB was related to the traps at grain boundaries in MAPbI3 and had a low photon energy threshold (red photons) for deactivation. The energy level of TGB was higher than that of the conduction band of MAPbI3. Under blue excitation, TGB mediated a fast nonradiative recombination at few nanoseconds, and TL and TH mediated a slow nonradiative recombination at few 100 ns. The fast nonradiative recombination led to a significantly low initial normalized photoluminescence quantum yield (PLQY) (1/22) under blue excitation, compared with that obtained under red excitation (1/4). The deactivation of TL and TH resulted in increases in both the amplitude of PL and recombination time. The deactivation of TGB resulted only in a significant increase in PLQY of blue excitation.
- 9 May 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (30) , 305105
Charge relaxation associated with photon-induced deactivation of various traps in MAPbI3 films
Photon-induced deactivation of traps in MAPbI3 can strongly affect charge relaxation behavior. Charge relaxation associated with photo-induced deactivation of various traps in MAPbI3 films was investigated through steady-state and time-resolved photoluminescence (PL) spectroscopy under laser excitation at 635 and 430 nm to investigate the properties of the traps. Three types of traps that could be deactivated by photons were observed in the MAPbI3 films, namely TL, TH, and TGB. TL and TH, which were related to MAPbI3 bulk, had low and high photon energy thresholds (red and blue photons) for deactivation, respectively. TGB was related to the traps at grain boundaries in MAPbI3 and had a low photon energy threshold (red photons) for deactivation. The energy level of TGB was higher than that of the conduction band of MAPbI3. Under blue excitation, TGB mediated a fast nonradiative recombination at few nanoseconds, and TL and TH mediated a slow nonradiative recombination at few 100 ns. The fast nonradiative recombination led to a significantly low initial normalized photoluminescence quantum yield (PLQY) (1/22) under blue excitation, compared with that obtained under red excitation (1/4). The deactivation of TL and TH resulted in increases in both the amplitude of PL and recombination time. The deactivation of TGB resulted only in a significant increase in PLQY of blue excitation.
- Open Access
- 4 August 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Editorial: Biophotonics for cancer diagnostics and treatment
Editorial: Biophotonics for cancer diagnostics and treatment
- 4 August 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessEditorial: Biophotonics for cancer diagnostics and treatment
Editorial: Biophotonics for cancer diagnostics and treatment
- Open Access
- 21 March 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Editorial: Label Free Polarization Resolved Optical Microscopy for Biomedical Applications
Editorial: Label Free Polarization Resolved Optical Microscopy for Biomedical Applications
- 21 March 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessEditorial: Label Free Polarization Resolved Optical Microscopy for Biomedical Applications
Editorial: Label Free Polarization Resolved Optical Microscopy for Biomedical Applications
- 14 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (7) , 074102
Time-resolved imaging of ultrasound waveform with synchronized laser illumination
We present a synchronous time delay technique to precisely control the illuminating laser pulses and the ultrasonic wave generation to visualize the ultrasound waveform through the Schlieren imaging method. The proposed time-resolved imaging technique offers the two-dimensional mapping of ultrasound waveform in a temporally evolved manner. The critical physical parameters, such as speed and spatial pulse length of ultrasonic waves, are visualized and calculated from image analysis. Our results suggest a protocol in characterizing ultrasound waveform, and it has the potential to reconstruct the acoustic field by accumulating the time-lapse waveforms.
- 14 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (7) , 074102
Time-resolved imaging of ultrasound waveform with synchronized laser illumination
We present a synchronous time delay technique to precisely control the illuminating laser pulses and the ultrasonic wave generation to visualize the ultrasound waveform through the Schlieren imaging method. The proposed time-resolved imaging technique offers the two-dimensional mapping of ultrasound waveform in a temporally evolved manner. The critical physical parameters, such as speed and spatial pulse length of ultrasonic waves, are visualized and calculated from image analysis. Our results suggest a protocol in characterizing ultrasound waveform, and it has the potential to reconstruct the acoustic field by accumulating the time-lapse waveforms.
- Open Access
- 4 February 2021
- Published by Optica Publishing Group in OSA Continuum
- Vol. 4 (2) , 711-719
Spectrally resolved optical beam-induced current imaging of ESD induced defects on VCSELs
Optical beam-induced current (OBIC) mapping is widely used to characterize semiconductor lasers, particularly for failure analysis, in which the reliability has been a critical issue to be resolved spectrally and temporally. OBIC microscopy is advantageous for its non-invasiveness, when compared with electron beam-induced current (EBIC) microscopy. However, for high-speed devices, conventional OBIC methods may be limited in observing the spectral responses adequately. In this work, we present a modified OBIC microscopy based on a tunable ultrafast laser, to address the need for spectral resolving for precision failure spot analysis in vertical-cavity surface-emitting laser (VCSEL) diodes. The spectral OBIC response of VCSEL diodes is investigated by varying the irradiation wavelengths. Importantly, the ultrafast mode-locked laser provides broadband wavelength range to investigate photocurrent responses of the VCSELs sample. Specifically, the OBIC, electroluminescence (EL) detection, and the reflectance of the normal and the electrostatic discharge (ESD) damaged VCSELs are compared. We have found the ESD damaged VCSELs showing a redshifted spectral response.
- 4 February 2021
- Published by Optica Publishing Group in OSA Continuum
- Vol. 4 (2) , 711-719
Open AccessSpectrally resolved optical beam-induced current imaging of ESD induced defects on VCSELs
Optical beam-induced current (OBIC) mapping is widely used to characterize semiconductor lasers, particularly for failure analysis, in which the reliability has been a critical issue to be resolved spectrally and temporally. OBIC microscopy is advantageous for its non-invasiveness, when compared with electron beam-induced current (EBIC) microscopy. However, for high-speed devices, conventional OBIC methods may be limited in observing the spectral responses adequately. In this work, we present a modified OBIC microscopy based on a tunable ultrafast laser, to address the need for spectral resolving for precision failure spot analysis in vertical-cavity surface-emitting laser (VCSEL) diodes. The spectral OBIC response of VCSEL diodes is investigated by varying the irradiation wavelengths. Importantly, the ultrafast mode-locked laser provides broadband wavelength range to investigate photocurrent responses of the VCSELs sample. Specifically, the OBIC, electroluminescence (EL) detection, and the reflectance of the normal and the electrostatic discharge (ESD) damaged VCSELs are compared. We have found the ESD damaged VCSELs showing a redshifted spectral response.
- 23 March 2020
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 8 (2) , 024008
High temporal resolution and polarization resolved fluorescence lifetime measurements through stimulated emission
We have implemented polarization-resolved fluorescence lifetime measurement through stimulated emission based pump-probe technique, which promises much higher temporal resolution (∼4 ps) than conventional time-correlated single-photon counting (TCSPC). The depolarization of ATTO 647N fluorescent dye is resolved through anisotropy fluorescence lifetime measurements, with variable time delay introduced between the pump and the probe beams. Importantly, the polarization anisotropy measurement and the corresponding rotational correlation time characterization of the fluorescent dye are carried out at various temperatures. We have also demonstrated the need of high temporal resolution via hetero Förster energy transfer (Hetero-FRET) through the interaction between the gold nanorods (GNRs) and the fluorescent dye ATTO 647N. Notably, our results compare highly favorably with conventional TCSPC method, which is rather limited in temporal resolution, for the above characterization. Additionally, this technique is applicable even under ambient light while being very cost-effective and robust.
- 23 March 2020
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 8 (2) , 024008
High temporal resolution and polarization resolved fluorescence lifetime measurements through stimulated emission
We have implemented polarization-resolved fluorescence lifetime measurement through stimulated emission based pump-probe technique, which promises much higher temporal resolution (∼4 ps) than conventional time-correlated single-photon counting (TCSPC). The depolarization of ATTO 647N fluorescent dye is resolved through anisotropy fluorescence lifetime measurements, with variable time delay introduced between the pump and the probe beams. Importantly, the polarization anisotropy measurement and the corresponding rotational correlation time characterization of the fluorescent dye are carried out at various temperatures. We have also demonstrated the need of high temporal resolution via hetero Förster energy transfer (Hetero-FRET) through the interaction between the gold nanorods (GNRs) and the fluorescent dye ATTO 647N. Notably, our results compare highly favorably with conventional TCSPC method, which is rather limited in temporal resolution, for the above characterization. Additionally, this technique is applicable even under ambient light while being very cost-effective and robust.