SDSubir Das

Subir Das

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Subir Das has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Supercritical Angle Fluorescence and Raman Techniques in Biophotonics

    by Subir Das, Nathalia Simea Münch, Stefan Seeger

    Fluorescence and Raman microscopy have gained popularity in bioimaging due to their unique ability to provide three‐dimensional images at excellent contrast in both label and label‐free manners. Currently, conventional optical microscopy techniques make it relatively easy to measure these two mechanisms of a sample's contrast but can access a limited range of resolutions. The recent developments in optical microscopy for the interface through detection manipulation can easily access resolution down to the diffraction limit that utilizes evanescent waves (EW). For example, EW‐based supercritical angle (SA) microscopy can offer much greater axial confinement information than the existing total internal reflection (TIR) techniques and allow for structural and functional imaging with and without the need for fluorescent dyes and labels. This review begins by exploring the fundamental principles of SA fluorescence (SAF) and Raman (SAR) microscopy, shedding light on the underlying physical mechanisms and the advantages they offer over conventional imaging techniques. We delve into the optical principles and instrumentation, highlighting the role of EWs and the critical angle in the excitation and detection of fluorescence signals and Raman scattering from samples. In conclusion, this review article provides a comprehensive overview of the current state of SAF and SAR microscopy in biophotonics.

  • Open Access

    Raman Spectroscopy and Machine Learning in the Diagnosis of Breast Cancer

    by Sowndarya Rao, Nikita Sharma, Vyasraj G Bhat, Vibha Kamath, Mehak Thakur, Sindhoora Kaniyala Melanthota, Subir Das, Budheswar Dehury, Nirmal Mazumder

    The most prevalent cancer in women worldwide, breast cancer, greatly benefits from early identification for better prognoses. But traditional diagnostic techniques, like biopsies and mammograms, can require invasive procedures and lack accuracy. The non-invasive, quick, and accurate nature of machine learning (ML) and Raman spectroscopy (RS) in breast cancer diagnoses are examined in this review. Combining machine learning’s capacity to analyse intricate spectrum datasets with Raman spectroscopy’s ability to produce molecular fingerprints of biochemical alterations linked to cancer improves diagnostic precision. Using the PRISMA methodology, studies published from 2017 to 2024 were examined, with an emphasis on those that reported sensitivity and specificity values greater than 80%. With sensitivity and specificity frequently over 90%, the nine included studies show that Raman spectroscopy combined with machine learning methods such as support vector machines, convolutional neural networks, and linear discriminant analysis yields good diagnostic metrics. The investigation highlights Raman spectroscopy’s adaptability in analysing biological material, such as tissues and serum, with prospective uses extending to intraoperative, real-time evaluations. Although encouraging, there are still issues that need to be resolved, like the requirement for common frameworks, multi-centre validation, and affordable technology. A thorough assessment of RS-ML applications is given by this study, which also offers insights into its therapeutic potential and directs future studies in breast cancer detection. Clinical trial number: Not applicable


  • Open Access

    Unveiling the effect of CaCl2 on amyloid β aggregation via supercritical angle Raman and fluorescence spectroscopy and microscopy

    by Nathalia Simea Münch, Subir Das, Stefan Seeger

    Amyloid β aggregation is an important factor in Alzheimer's disease. Since calcium homeostasis plays an important role in amyloid β aggregation, it is crucial to study the interaction between calcium ions and amyloid β directly at the surface of the lipid membrane. With supercritical angle techniques, the signal of interest at the surface is easily separated from the bulk solution, making them a powerful tool for aggregation study. In this work, the influence of calcium ions on amyloid β aggregation over different aggregation time periods is investigated with supercritical angle Raman and fluorescence spectroscopy and microscopy. Note that calcium ions have a larger influence on amyloid β1–42 than on the 40 amino acid variant. We found that a small layer of calcium ions significantly protects the lipid membrane against the protein insertion process.


  • 10.1063/5.0077951.1

    by Subir Das, Yun-Yu Hsu, Ying-Rue Kao

    We present a synchronous time delay technique to precisely control the illuminating laser pulses and the ultrasonic wave generation to visualize the ultrasound waveform through the Schlieren imaging method. The proposed time-resolved imaging technique offers the two-dimensional mapping of ultrasound waveform in a temporally evolved manner. The critical physical parameters, such as speed and spatial pulse length of ultrasonic waves, are visualized and calculated from image analysis. Our results suggest a protocol in characterizing ultrasound waveform, and it has the potential to reconstruct the acoustic field by accumulating the time-lapse waveforms.

  • Time-resolved imaging of ultrasound waveform with synchronized laser illumination

    by Subir Das, Yun-Yu Hsu, Ying-Rue Kao, Bao-Yu Hsieh, Fu-Jen Kao

    We present a synchronous time delay technique to precisely control the illuminating laser pulses and the ultrasonic wave generation to visualize the ultrasound waveform through the Schlieren imaging method. The proposed time-resolved imaging technique offers the two-dimensional mapping of ultrasound waveform in a temporally evolved manner. The critical physical parameters, such as speed and spatial pulse length of ultrasonic waves, are visualized and calculated from image analysis. Our results suggest a protocol in characterizing ultrasound waveform, and it has the potential to reconstruct the acoustic field by accumulating the time-lapse waveforms.


  • Open Access

    Spectrally resolved optical beam-induced current imaging of ESD induced defects on VCSELs

    by Che-Lun Hsu, Subir Das, Yen-Hsiang Wu, Fu-Jen Kao

    Optical beam-induced current (OBIC) mapping is widely used to characterize semiconductor lasers, particularly for failure analysis, in which the reliability has been a critical issue to be resolved spectrally and temporally. OBIC microscopy is advantageous for its non-invasiveness, when compared with electron beam-induced current (EBIC) microscopy. However, for high-speed devices, conventional OBIC methods may be limited in observing the spectral responses adequately. In this work, we present a modified OBIC microscopy based on a tunable ultrafast laser, to address the need for spectral resolving for precision failure spot analysis in vertical-cavity surface-emitting laser (VCSEL) diodes. The spectral OBIC response of VCSEL diodes is investigated by varying the irradiation wavelengths. Importantly, the ultrafast mode-locked laser provides broadband wavelength range to investigate photocurrent responses of the VCSELs sample. Specifically, the OBIC, electroluminescence (EL) detection, and the reflectance of the normal and the electrostatic discharge (ESD) damaged VCSELs are compared. We have found the ESD damaged VCSELs showing a redshifted spectral response.


  • High temporal resolution and polarization resolved fluorescence lifetime measurements through stimulated emission

    by Khalil Ur Rehman, Subir Das, Yih-Fan Chen, Fu-Jen Kao

    We have implemented polarization-resolved fluorescence lifetime measurement through stimulated emission based pump-probe technique, which promises much higher temporal resolution (∼4 ps) than conventional time-correlated single-photon counting (TCSPC). The depolarization of ATTO 647N fluorescent dye is resolved through anisotropy fluorescence lifetime measurements, with variable time delay introduced between the pump and the probe beams. Importantly, the polarization anisotropy measurement and the corresponding rotational correlation time characterization of the fluorescent dye are carried out at various temperatures. We have also demonstrated the need of high temporal resolution via hetero Förster energy transfer (Hetero-FRET) through the interaction between the gold nanorods (GNRs) and the fluorescent dye ATTO 647N. Notably, our results compare highly favorably with conventional TCSPC method, which is rather limited in temporal resolution, for the above characterization. Additionally, this technique is applicable even under ambient light while being very cost-effective and robust.


  • Open Access

    Spontaneous loss versus stimulation gain in pump-probe microscopy: a proof of concept demonstration

    by Subir Das, Khalil Ur Rehman, Guan-Yu Zhuo, Fu-Jen Kao

    Pump-probe microscopy has been a versatile and powerful platform that takes advantage of transient absorption (TA) and gain in nonlinear optical processes with many imaging modalities, including both labeled and label-free ones. The labeled imaging modalities, such as stimulated emission (SE), excited state absorption, and ground state depletion, are able to reveal molecular specificity, improve resolution, and enhance penetration depth.1 – 5 The label-free ones include stimulated Raman scattering (SRS)6 and TA.7 These imaging modalities have been shown to reveal the structural features and transient phenomena in biology and chemistry at picosecond or femtosecond time scales.8 – 12 In the pump-probe technique, the pump pulse is used to excite the sample and the induced changes are then monitored by the synchronized probe pulse. Notably, lock-in detection is used throughout the pump-probe microscopy for both labeled and label-free imaging to recover the relatively small modulated signals from the very large background.


  • Background free imaging in stimulated emission fluorescence microscopy

    by Subir Das, I-Che Chen, Khalil Ur Rehman, Jung-Lung Hsu, Guan-Yu Zhuo, Fu-Jen Kao

    Recently, the pump-probe technique has found highly valued developments and applications in optical microscopy to study both labeled (fluorescence) and non-labeled (vibrational) for observation of cells and tissues. In this work, we use the mechanism of stimulated emission (SE) with dual frequency modulation to remove the large background signal that is originated from spontaneous emission. We have applied a high performance digital signal processing based lock-in detection for stimulated emission fluorescence microscopy. Critically, the pump beam is modulated at f 1 and the probe beam is at a different frequency, f 2 , with the demodulation carried out at the sum of the two frequencies, ( f 1 + f 2 ). In this way, the DC background is effectively removed. Note that the background is mainly attributed to the spontaneous emission of the pump beam, with modulated frequency f 1 .