Hao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hao Wu has a total of 154 co-authors. Here are the top co-authors by number of shared publications:
Liangliang Ma
17 shared publicationsYuehua Cheng
Tongji University
16 shared publicationsYing Zhou
11 shared publicationsXiangzhen Kong
Army Engineering University of PLA
6 shared publicationsYong Peng
National University of Defense Technology
6 shared publications- Abderrahim Djerrad
College of Civil Engineering, Tongji University, 1239 Siping Rd., Shanghai 200092, China
5 shared publications
Latest Publications
- 4 October 2026
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 221
Theoretical identification framework for failure modes of RC beams under low-velocity impact
- 4 October 2026
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 221
Theoretical identification framework for failure modes of RC beams under low-velocity impact
- 26 September 2026
- Published by Wiley in Structural Concrete
Structural retrofitting design of Shanghai Indoor Stadium
- 26 September 2026
- Published by Wiley in Structural Concrete
Structural retrofitting design of Shanghai Indoor Stadium
- 2 July 2026
- Published by Springer Nature
- p. 231-250
Generalizable ML Solutions for Predicting Equivalent Viscous Damping Ratio of Diagonal RC Coupling Beams
- 2 July 2026
- Published by Springer Nature
- p. 231-250
Generalizable ML Solutions for Predicting Equivalent Viscous Damping Ratio of Diagonal RC Coupling Beams
- 2 June 2026
- Published by Springer Nature
- p. 139-160
An ML Framework for Equivalent Viscous Damping Ratio of RC Shear Walls
- 2 June 2026
- Published by Springer Nature
- p. 139-160
An ML Framework for Equivalent Viscous Damping Ratio of RC Shear Walls
- 29 May 2026
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 35 (6) , e70151
Efficient SMA–Steel Bar Mechanical Connection for Seismic‐Resilient Structures: Experimental Evaluation
Shape memory alloys (SMAs) have attracted increasing attention in recent years for their application in self‐centering (SC) seismic structures. To take full advantage of their recovery capability and energy dissipation (ED) potential, SMAs are typically incorporated into plastic hinge regions of reinforced concrete components as longitudinal reinforcement or utilized in high‐performance seismic protection devices. However, for widely used nickel–titanium SMAs, their smooth surface and poor machinability present significant challenges for the design of reliable mechanical connections with conventional steel reinforcement. To address this issue, this study proposes an efficient SMA–steel bar connection strategy that integrates swaged sleeves on SMA bars with straight‐threaded couplers, enabling reliable force transfer and rapid specimen assembly. The structural configuration and key design considerations of the proposed connection system were first presented. Experimental investigations were then conducted to evaluate its mechanical performance, with particular emphasis on the effects of sleeve length and bar diameter. Test results demonstrate that the proposed connection system provides a stable mechanical splice and reliable load transfer under various loading conditions, while maintaining the characteristic flag‐shaped hysteretic response of SMAs. Although the ED capacity of SMAs is lower than that of conventional hysteretic dampers, their primary function is to provide substantial SC capability to structural systems, which makes them highly attractive for seismic design. This study provides an efficient and reliable connection solution for SMA bars, supporting their wide application in seismic‐resilient structural systems.
- 29 May 2026
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 35 (6) , e70151
Efficient SMA–Steel Bar Mechanical Connection for Seismic‐Resilient Structures: Experimental Evaluation
Shape memory alloys (SMAs) have attracted increasing attention in recent years for their application in self‐centering (SC) seismic structures. To take full advantage of their recovery capability and energy dissipation (ED) potential, SMAs are typically incorporated into plastic hinge regions of reinforced concrete components as longitudinal reinforcement or utilized in high‐performance seismic protection devices. However, for widely used nickel–titanium SMAs, their smooth surface and poor machinability present significant challenges for the design of reliable mechanical connections with conventional steel reinforcement. To address this issue, this study proposes an efficient SMA–steel bar connection strategy that integrates swaged sleeves on SMA bars with straight‐threaded couplers, enabling reliable force transfer and rapid specimen assembly. The structural configuration and key design considerations of the proposed connection system were first presented. Experimental investigations were then conducted to evaluate its mechanical performance, with particular emphasis on the effects of sleeve length and bar diameter. Test results demonstrate that the proposed connection system provides a stable mechanical splice and reliable load transfer under various loading conditions, while maintaining the characteristic flag‐shaped hysteretic response of SMAs. Although the ED capacity of SMAs is lower than that of conventional hysteretic dampers, their primary function is to provide substantial SC capability to structural systems, which makes them highly attractive for seismic design. This study provides an efficient and reliable connection solution for SMA bars, supporting their wide application in seismic‐resilient structural systems.
- Open Access
Experimental Study on the Performance of an Earthquake-Damaged Frame Upgraded with Viscous Dampers
This study presents an experimental investigation into the repair and seismic performance enhancement of earthquake-damaged reinforced concrete (RC) frame structures using high-strength cement mortar and viscous dampers. A 1/4-scale, four-story RC frame model—designed according to a seismic fortification intensity of 8 degrees (corresponding to 0.2 g PGA in China’s seismic code)—was subjected to shaking table tests under increasing levels of artificial seismic excitation. Following the first round of loading, the damaged structure was repaired using high-strength mortar infill, and 12 viscous dampers were installed for seismic upgrade. The second round of identical seismic loading was applied to evaluate the effectiveness of the repair strategy. Comparative analysis of structural responses before and after repair reveals that the combination of high-strength mortar and viscous dampers improved damping capacity. The initial natural frequencies of the repaired structure increased by 6% (X) and 24% (Y), and damping ratios rose—reaching 12.75% and 10.78% under rare ground motions (1.34 g). Peak acceleration and inter-story drift ratio (IDR) were effectively reduced under moderate seismic levels, although some increase in IDR was observed at higher intensities, all drift values remained within the seismic code limits. The viscous dampers significantly altered the inter-story deformation mechanism, reducing the deformation concentration factor (DCF) of the frame structure and resulting in a more uniform distribution of story drifts. In addition, the energy dissipation capacity of the dampers increased progressively with the intensity of seismic excitation. The results validate the feasibility and efficiency of integrating viscous dampers with high-strength mortar for seismic repair and retrofitting of RC frame structure.
Open AccessExperimental Study on the Performance of an Earthquake-Damaged Frame Upgraded with Viscous Dampers
This study presents an experimental investigation into the repair and seismic performance enhancement of earthquake-damaged reinforced concrete (RC) frame structures using high-strength cement mortar and viscous dampers. A 1/4-scale, four-story RC frame model—designed according to a seismic fortification intensity of 8 degrees (corresponding to 0.2 g PGA in China’s seismic code)—was subjected to shaking table tests under increasing levels of artificial seismic excitation. Following the first round of loading, the damaged structure was repaired using high-strength mortar infill, and 12 viscous dampers were installed for seismic upgrade. The second round of identical seismic loading was applied to evaluate the effectiveness of the repair strategy. Comparative analysis of structural responses before and after repair reveals that the combination of high-strength mortar and viscous dampers improved damping capacity. The initial natural frequencies of the repaired structure increased by 6% (X) and 24% (Y), and damping ratios rose—reaching 12.75% and 10.78% under rare ground motions (1.34 g). Peak acceleration and inter-story drift ratio (IDR) were effectively reduced under moderate seismic levels, although some increase in IDR was observed at higher intensities, all drift values remained within the seismic code limits. The viscous dampers significantly altered the inter-story deformation mechanism, reducing the deformation concentration factor (DCF) of the frame structure and resulting in a more uniform distribution of story drifts. In addition, the energy dissipation capacity of the dampers increased progressively with the intensity of seismic excitation. The results validate the feasibility and efficiency of integrating viscous dampers with high-strength mortar for seismic repair and retrofitting of RC frame structure.
- 14 February 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 224
Seismic performance of a tall RC chimney structure with an emphasis on vertical seismic behavior using shaking table test
- 14 February 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 224
Seismic performance of a tall RC chimney structure with an emphasis on vertical seismic behavior using shaking table test
- Open Access
Assessing the Seismic Performance of Prefabricated Coupling Beams Using Double-Lap Sleeves: An Experimental and Numerical Investigation
To advance the application of prefabricated structures, this study proposes a novel sleeve connection for reinforced concrete coupling beams, aiming to balance the construction efficiency with seismic performance in prefabricated structures. Quasi-static tests and numerical simulations were conducted, investigating the effects of span-to-depth ratio, connection type, and casting method. The experimental results demonstrate that the proposed sleeve-connected beams exhibit seismic performance comparable to, and in some cases superior to, their cast-in-place counterparts. Specifically, the prefabricated specimen with a span-to-depth ratio of 4 achieved approximately 85% of the energy dissipation capacity of its cast-in-place counterpart. However, as the span-to-depth ratio decreased, the energy dissipation capacity of the prefabricated beams increased significantly, reaching up to 2.5 times that of the cast-in-place specimens. Numerical simulations, which showed good agreement with experimental results in terms of failure modes and hysteresis curves, further revealed that concrete compressive strength has a limited influence on seismic behavior. In contrast, increasing the reinforcement ratio effectively improved stiffness and ductility. Notably, increasing the rebar diameter from 18 mm to 22 mm resulted in approximately 25% improvement in energy dissipation capacity. The findings provide novel insights and a scientific basis for the practical application of this innovative prefabricated solution.
Open AccessAssessing the Seismic Performance of Prefabricated Coupling Beams Using Double-Lap Sleeves: An Experimental and Numerical Investigation
To advance the application of prefabricated structures, this study proposes a novel sleeve connection for reinforced concrete coupling beams, aiming to balance the construction efficiency with seismic performance in prefabricated structures. Quasi-static tests and numerical simulations were conducted, investigating the effects of span-to-depth ratio, connection type, and casting method. The experimental results demonstrate that the proposed sleeve-connected beams exhibit seismic performance comparable to, and in some cases superior to, their cast-in-place counterparts. Specifically, the prefabricated specimen with a span-to-depth ratio of 4 achieved approximately 85% of the energy dissipation capacity of its cast-in-place counterpart. However, as the span-to-depth ratio decreased, the energy dissipation capacity of the prefabricated beams increased significantly, reaching up to 2.5 times that of the cast-in-place specimens. Numerical simulations, which showed good agreement with experimental results in terms of failure modes and hysteresis curves, further revealed that concrete compressive strength has a limited influence on seismic behavior. In contrast, increasing the reinforcement ratio effectively improved stiffness and ductility. Notably, increasing the rebar diameter from 18 mm to 22 mm resulted in approximately 25% improvement in energy dissipation capacity. The findings provide novel insights and a scientific basis for the practical application of this innovative prefabricated solution.
- 21 August 2025
- Published by Elsevier in Structures
- Vol. 80
Seismic performance analysis of horizontally isolated point-fixed glass façade system incorporated in self-centering wall structure
- 21 August 2025
- Published by Elsevier in Structures
- Vol. 80
Seismic performance analysis of horizontally isolated point-fixed glass façade system incorporated in self-centering wall structure