Gregory Brent
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gregory Brent has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
- Pierre-Alexandre Gourdain
Rochester University, Rochester, NY, USA
3 shared publications C. Mileham
Laboratory for Laser Energetics, University of Rochester 1 , Rochester, New York 14623-1299, USA
2 shared publicationsD. Guy
Laboratory for Laser Energetics, University of Rochester 1 , Rochester, New York 14623-1299, USA
2 shared publications- Daniel Barnak
Laboratory for Laser Energetics, University of Rochester , Rochester, New York 14623-1299
2 shared publications M. J. Shoup
Laboratory for Laser Energetics, University of Rochester, 250 East River Rd, Rochester, New York 14623-1299, USA
2 shared publicationsR. Betti
Laboratory for Laser Energetics, University of Rochester , 250 E. River Road, Rochester, New York 14623, USA
2 shared publications
Latest Publications
- Open Access
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 123502
Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser
A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>1018 W/cm2) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. The initial results from four OMEGA EP THz experiments detected up to ∼15μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 123502
Open AccessDevelopment of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser
A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>1018 W/cm2) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. The initial results from four OMEGA EP THz experiments detected up to ∼15μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.
- Open Access
- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8)
An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils
Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. We demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.
- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8)
Open AccessAn assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils
Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. We demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.
- Open Access
- 9 August 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (8) , 080401
Design of 30-T pulsed magnetic field generator for magnetized high-energy-density plasma experiments
This paper presents the conceptual design of a high-voltage pulser intended to generate 30-T magnetic fields for magneto-inertial fusion experiments at the OMEGA facility. The pulser uses a custom capacitor bank and two externally triggered spark gaps to drive a multiturn coil. This new high-voltage pulser is capable of storing 10 times more energy than the previous system, using a higher charge voltage (from 20 to 30 kV) and a larger capacitance (from 1 to ). Circuit simulations show that this pulser can deliver 100 kA into a 60-nH, coil with a rise time of . For a coil with two turns with an average coil diameter of 7.8 mm, this current translates into a 32-T peak magnetic field at coil center. This is a factor of 3 increase in the peak magnetic field compared to the present generator magnetic field capabilities.- 9 August 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (8) , 080401
Open AccessDesign of 30-T pulsed magnetic field generator for magnetized high-energy-density plasma experiments
This paper presents the conceptual design of a high-voltage pulser intended to generate 30-T magnetic fields for magneto-inertial fusion experiments at the OMEGA facility. The pulser uses a custom capacitor bank and two externally triggered spark gaps to drive a multiturn coil. This new high-voltage pulser is capable of storing 10 times more energy than the previous system, using a higher charge voltage (from 20 to 30 kV) and a larger capacitance (from 1 to ). Circuit simulations show that this pulser can deliver 100 kA into a 60-nH, coil with a rise time of . For a coil with two turns with an average coil diameter of 7.8 mm, this current translates into a 32-T peak magnetic field at coil center. This is a factor of 3 increase in the peak magnetic field compared to the present generator magnetic field capabilities. - 1 May 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (5) , 053001
The Dynamic Compression Sector laser: A 100-J UV laser for dynamic compression research
The Dynamic Compression Sector (DCS) laser is a 100-J ultraviolet Nd:glass system designed and built by the Laboratory for Laser Energetics for experimental research at the DCS located at the Advanced Photon Source (Argonne National Laboratory). Its purpose is to serve as a shock driver to study materials under extreme dynamic pressures. It was designed to deposit energy within a uniformly illuminated 500-μm spot on target, with additional optics provided to implement spot sizes of 250 and 1000 μm. Designed after larger-scale glass lasers such as OMEGA and the National Ignition Facility, the laser consists of a fiber front end with interferometer-based pulse shaping, a Nd:glass regenerative amplifier, a four-pass rod amplifier, and a 15-cm glass disk amplifier, through which six passes are made in a bowtie geometry. The output is frequency tripled from 1053 to 351 nm by using a pair of type-II phase-matched KDP crystals, with a third to increase conversion bandwidth. The super-Gaussian spot in the far field is achieved with a distributed phase plate and a 1-m aspherical focusing lens. Beam smoothing is achieved by smoothing by spectral dispersion and polarization smoothing, resulting in a root-mean-square variation in intensity on target of ±8.7%.
- 1 May 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (5) , 053001
The Dynamic Compression Sector laser: A 100-J UV laser for dynamic compression research
The Dynamic Compression Sector (DCS) laser is a 100-J ultraviolet Nd:glass system designed and built by the Laboratory for Laser Energetics for experimental research at the DCS located at the Advanced Photon Source (Argonne National Laboratory). Its purpose is to serve as a shock driver to study materials under extreme dynamic pressures. It was designed to deposit energy within a uniformly illuminated 500-μm spot on target, with additional optics provided to implement spot sizes of 250 and 1000 μm. Designed after larger-scale glass lasers such as OMEGA and the National Ignition Facility, the laser consists of a fiber front end with interferometer-based pulse shaping, a Nd:glass regenerative amplifier, a four-pass rod amplifier, and a 15-cm glass disk amplifier, through which six passes are made in a bowtie geometry. The output is frequency tripled from 1053 to 351 nm by using a pair of type-II phase-matched KDP crystals, with a third to increase conversion bandwidth. The super-Gaussian spot in the far field is achieved with a distributed phase plate and a 1-m aspherical focusing lens. Beam smoothing is achieved by smoothing by spectral dispersion and polarization smoothing, resulting in a root-mean-square variation in intensity on target of ±8.7%.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10898, 22
High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics
High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180- to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth-harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 × 12 mm, ≤ 1.5 J, ≤ 5 Hz ). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 × 65 × 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10898, 22
High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics
High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180- to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth-harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 × 12 mm, ≤ 1.5 J, ≤ 5 Hz ). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 × 65 × 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.
- 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 095102
The generation of mega-gauss fields on the Cornell beam research accelerator
Intense magnetic fields modify quantum processes in extremely dense matter, calling for precise measurements in very harsh conditions. This endeavor becomes even more challenging because the generation of mega-gauss fields in a laboratory is far from trivial. This paper presents a unique and compact approach to generate fields above 2 MG in less than 150 ns inside a volume on the order of half a cubic centimeter. Magnetic insulation, keeping plasma ablation close to the wire surface, and mechanical inertia, limiting coil motion throughout the current discharge, enable the generation of intense magnetic fields where the shape of the conductor controls the field topology with exquisite precision and versatility, limiting the need for mapping magnetic fields experimentally.
- 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 095102
The generation of mega-gauss fields on the Cornell beam research accelerator
Intense magnetic fields modify quantum processes in extremely dense matter, calling for precise measurements in very harsh conditions. This endeavor becomes even more challenging because the generation of mega-gauss fields in a laboratory is far from trivial. This paper presents a unique and compact approach to generate fields above 2 MG in less than 150 ns inside a volume on the order of half a cubic centimeter. Magnetic insulation, keeping plasma ablation close to the wire surface, and mechanical inertia, limiting coil motion throughout the current discharge, enable the generation of intense magnetic fields where the shape of the conductor controls the field topology with exquisite precision and versatility, limiting the need for mapping magnetic fields experimentally.
- Open Access
- 21 June 2017
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 2 (4) , 204-223
Conceptual design of a 15-TW pulsed-power accelerator for high-energy-density—physics experiments
We have developed a conceptual design of a 15-TW pulsed-power accelerator based on the linear-transformer-driver (LTD) architecture described by Stygar [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The driver will allow multiple, high-energy-density experiments per day in a university environment and, at the same time, will enable both fundamental and integrated experiments that are scalable to larger facilities. In this design, many individual energy storage units (bricks), each composed of two capacitors and one switch, directly drive the target load without additional pulse compression. Ten LTD modules in parallel drive the load. Each module consists of 16 LTD cavities connected in series, where each cavity is powered by 22 bricks connected in parallel. This design stores up to 2.75 MJ and delivers up to 15 TW in 100 ns to the constant-impedance, water-insulated radial transmission lines. The transmission lines in turn deliver a peak current as high as 12.5 MA to the physics load. To maximize its experimental value and flexibility, the accelerator is coupled to a modern, multibeam laser facility (four beams with up to 5 kJ in 10 ns and one beam with up to 2.6 kJ in 100 ps or less) that can provide auxiliary heating of the physics load. The lasers also enable advanced diagnostic techniques such as X-ray Thomson scattering and multiframe and three-dimensional radiography. The coupled accelerator-laser facility will be the first of its kind and be capable of conducting unprecedented high-energy-density–physics experiments.
- 21 June 2017
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 2 (4) , 204-223
Open AccessConceptual design of a 15-TW pulsed-power accelerator for high-energy-density—physics experiments
We have developed a conceptual design of a 15-TW pulsed-power accelerator based on the linear-transformer-driver (LTD) architecture described by Stygar [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The driver will allow multiple, high-energy-density experiments per day in a university environment and, at the same time, will enable both fundamental and integrated experiments that are scalable to larger facilities. In this design, many individual energy storage units (bricks), each composed of two capacitors and one switch, directly drive the target load without additional pulse compression. Ten LTD modules in parallel drive the load. Each module consists of 16 LTD cavities connected in series, where each cavity is powered by 22 bricks connected in parallel. This design stores up to 2.75 MJ and delivers up to 15 TW in 100 ns to the constant-impedance, water-insulated radial transmission lines. The transmission lines in turn deliver a peak current as high as 12.5 MA to the physics load. To maximize its experimental value and flexibility, the accelerator is coupled to a modern, multibeam laser facility (four beams with up to 5 kJ in 10 ns and one beam with up to 2.6 kJ in 100 ps or less) that can provide auxiliary heating of the physics load. The lasers also enable advanced diagnostic techniques such as X-ray Thomson scattering and multiframe and three-dimensional radiography. The coupled accelerator-laser facility will be the first of its kind and be capable of conducting unprecedented high-energy-density–physics experiments.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Conceptual design of a 960-TW accelerator powered by impedance-matched Marx generators
We have developed a conceptual design of a next-generation pulsed-power accelerator that is optimized for advanced high-energy-density-physics experiments. The prime power source of the machine consists of 210 impedance-matched Marx generators (IMGs). Each IMG drives a 150-ns-long coaxial-transmission-line impedance transformer. The coaxial lines provide a minimum of 300 ns of transit-time isolation between each pair of IMGs. The lines in turn drive six radial-transmission-line impedance transformers, which transport the power generated by the IMGs to a six-level vacuum-insulator stack. The stack is connected to six conical outer magnetically insulated vacuum transmission lines (MITLs); these are joined in parallel at a 12-cm radius by a triple-post-hole vacuum convolute. The convolute sums the electrical currents at the outputs of the six outer MITLs, and delivers the combined current to a single short inner MITL. The inner MITL transmits the combined current to the accelerator's physics load. Since the accelerator would be the largest and most-powerful pulsed-power machine developed to date, we refer to it as Jupiter. The conceptual design of Jupiter is 72 m in diameter, stores 140 MJ of electrical energy, and generates 960 TW of peak electrical power at the output of the IMG system. The design delivers 2700 TW, 67 MA, and 9.2 MJ in a 110-ns pulse to a 0D magnetized-liner inertial-fusion (MagLIF) target. The principal goal of the design is to achieve high-yield thermonuclear fusion; i.e., a fusion yield that exceeds the energy initially stored by the accelerator's capacitors.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Conceptual design of a 960-TW accelerator powered by impedance-matched Marx generators
We have developed a conceptual design of a next-generation pulsed-power accelerator that is optimized for advanced high-energy-density-physics experiments. The prime power source of the machine consists of 210 impedance-matched Marx generators (IMGs). Each IMG drives a 150-ns-long coaxial-transmission-line impedance transformer. The coaxial lines provide a minimum of 300 ns of transit-time isolation between each pair of IMGs. The lines in turn drive six radial-transmission-line impedance transformers, which transport the power generated by the IMGs to a six-level vacuum-insulator stack. The stack is connected to six conical outer magnetically insulated vacuum transmission lines (MITLs); these are joined in parallel at a 12-cm radius by a triple-post-hole vacuum convolute. The convolute sums the electrical currents at the outputs of the six outer MITLs, and delivers the combined current to a single short inner MITL. The inner MITL transmits the combined current to the accelerator's physics load. Since the accelerator would be the largest and most-powerful pulsed-power machine developed to date, we refer to it as Jupiter. The conceptual design of Jupiter is 72 m in diameter, stores 140 MJ of electrical energy, and generates 960 TW of peak electrical power at the output of the IMG system. The design delivers 2700 TW, 67 MA, and 9.2 MJ in a 110-ns pulse to a 0D magnetized-liner inertial-fusion (MagLIF) target. The principal goal of the design is to achieve high-yield thermonuclear fusion; i.e., a fusion yield that exceeds the energy initially stored by the accelerator's capacitors.
- Open Access
- 1 January 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (1) , 016105
Note: Experimental platform for magnetized high-energy-density plasma studies at the omega laser facility
An upgrade of the pulsed magnetic field generator magneto-inertial fusion electrical discharge system [O. Gotchev et al., Rev. Sci. Instrum. 80, 043504 (2009)] is described. The device is used to study magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of tens of tesla in a volume of a few cubic centimeters. The magnetic field is created by discharging a high-voltage capacitor through a small wire-wound coil. The coil current pulse has a duration of about 1 μs and a peak value of 40 kA. Compared to the original, the updated version has a larger energy storage and improved switching system. In addition, magnetic coils are fabricated using 3-D printing technology which allows for a greater variety of the magnetic field topology.
- 1 January 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (1) , 016105
Open AccessNote: Experimental platform for magnetized high-energy-density plasma studies at the omega laser facility
An upgrade of the pulsed magnetic field generator magneto-inertial fusion electrical discharge system [O. Gotchev et al., Rev. Sci. Instrum. 80, 043504 (2009)] is described. The device is used to study magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of tens of tesla in a volume of a few cubic centimeters. The magnetic field is created by discharging a high-voltage capacitor through a small wire-wound coil. The coil current pulse has a duration of about 1 μs and a peak value of 40 kA. Compared to the original, the updated version has a larger energy storage and improved switching system. In addition, magnetic coils are fabricated using 3-D printing technology which allows for a greater variety of the magnetic field topology.
- 24 July 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E501
Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)
A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si Heα line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.
- 24 July 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E501
Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)
A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si Heα line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.