Gholam Hossein Riahy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gholam Hossein Riahy has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Mehrdad Abedi
4 shared publications- Seyed Hossein Hosseinian
Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
4 shared publications - Behrooz Vahidi
Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
3 shared publications A. Kashefi Kaviani
2 shared publicationsFatemeh Jahanbani Ardakani
Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
2 shared publicationsM. H. Zamani
Amirkabir University of Technology (Tehran Polytechnic), Electrical engineering department, Wind energy lab., Iran
2 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Elsevier in SSRN Electronic Journal
Hybrid PI–Super-Twisting Current Controller for Robust Single-Stage Grid-Connected Photovoltaic Inverters
The proposed controller is implemented in a single-stage three-phase grid-connected photovoltaic inverter (GCPVI) and evaluated in the MATLAB/Simulink environment under three representative operating scenarios, including nominal operation, filter inductance degradation caused by aging, and severe balanced three-phase short-circuit faults. Its performance is systematically compared with conventional PI and Deadbeat predictive current controllers through both qualitative waveform analysis and quantitative performance indices, including total harmonic distortion (THD), current ripple, DC-link voltage ripple, tracking error, transient overshoot, settling time, FRT capability, together with implementation complexity considerations. Simulation results consistently demonstrate the superiority of the proposed controller over both benchmark methods under all investigated operating conditions. Compared with the conventional PI controller, the proposed Hybrid PI–STA controller reduces grid-current THD from 1.68% to 1.54%, decreases steady-state current ripple by approximately 20%, and lowers DC-link voltage ripple from 0.14% to 0.02%. Under a 30% filter inductance reduction, it maintains the smallest tracking error (0.19 pu) without controller retuning. During severe three-phase grid faults, it reduces DC-link voltage overshoot by approximately 71% and shortens the post-fault recovery time by 94.7% compared with the conventional PI controller while preserving implementation complexity comparable to that of classical PI control. These results verify that the proposed Hybrid PI–STA controller successfully combines the simplicity of conventional PI control with the robustness of higher-order sliding-mode control, providing an effective robust control solution for next-generation high-performance GCPVSs operating under uncertain and highly dynamic grid conditions.
- 28 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHybrid PI–Super-Twisting Current Controller for Robust Single-Stage Grid-Connected Photovoltaic Inverters
The proposed controller is implemented in a single-stage three-phase grid-connected photovoltaic inverter (GCPVI) and evaluated in the MATLAB/Simulink environment under three representative operating scenarios, including nominal operation, filter inductance degradation caused by aging, and severe balanced three-phase short-circuit faults. Its performance is systematically compared with conventional PI and Deadbeat predictive current controllers through both qualitative waveform analysis and quantitative performance indices, including total harmonic distortion (THD), current ripple, DC-link voltage ripple, tracking error, transient overshoot, settling time, FRT capability, together with implementation complexity considerations. Simulation results consistently demonstrate the superiority of the proposed controller over both benchmark methods under all investigated operating conditions. Compared with the conventional PI controller, the proposed Hybrid PI–STA controller reduces grid-current THD from 1.68% to 1.54%, decreases steady-state current ripple by approximately 20%, and lowers DC-link voltage ripple from 0.14% to 0.02%. Under a 30% filter inductance reduction, it maintains the smallest tracking error (0.19 pu) without controller retuning. During severe three-phase grid faults, it reduces DC-link voltage overshoot by approximately 71% and shortens the post-fault recovery time by 94.7% compared with the conventional PI controller while preserving implementation complexity comparable to that of classical PI control. These results verify that the proposed Hybrid PI–STA controller successfully combines the simplicity of conventional PI control with the robustness of higher-order sliding-mode control, providing an effective robust control solution for next-generation high-performance GCPVSs operating under uncertain and highly dynamic grid conditions.
- Open Access
- 4 August 2026
- Published by Elsevier in SSRN Electronic Journal
Integrated Modeling and Head-Aware Dispatch of a Wind Pumped Hydro Energy Storage with Droop-Based Frequency Support
We develop and validate a unified wind-pumped hydro energy storage (PHES) framework that co-optimizes day-ahead energy management and primary-frequency response within a single, physics-informed control stack. A head-aware supervisory layer shifts charge–discharge thresholds via a linear SOC-head surrogate and enforces explicit anti-chatter measures (deadband, dwell, ramp limits). On top, an SOC-gated droop layer delivers frequency support while honoring actuator and energy constraints. The model is exercised over five 24-h scenarios: variable and sustained wind, fast fluctuations, low-head (offline) operation, and a frequency event, and is evaluated using discharged, curtailed and unserved energy, round-trip-efficiency change, equivalent full cycles (EFCs), switching events, and frequency metrics. Under nominal head, reservoirs sized to avoid day-ahead limitation render head penalties non-binding; baseline and proposed policies yield near-identical Eout, Ecurt, and Edef while chatter is restrained. Under low head the controller correctly suppresses generation, shifting performance into Edef without destabilizing modes. During the frequency event the framework preserves primary capability (nadir ≈ 49.85 Hz, RoCoF ≈ −0.023 Hz/s, recovery < 1 min, droop-support energy ≈ 0.0062 MWh), matching the baseline. Sensitivity-guided tuning exposes a reproducible parameter set (droop ≈ 4 MW/Hz; deadband 0.05 Hz; SOC thresholds 0.2–0.3 and 0.7–0.8; head-gain ≈ 0.05) that balances prudence and responsiveness and transfers directly to islanded or weak grids. The contribution is an explicit head-aware energy policy unified with an SOC-gated droop in a single reproducible model, achieving baseline-equivalent frequency performance without optimization overhead and enabling transparent, physics-based tuning.
- 4 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessIntegrated Modeling and Head-Aware Dispatch of a Wind Pumped Hydro Energy Storage with Droop-Based Frequency Support
We develop and validate a unified wind-pumped hydro energy storage (PHES) framework that co-optimizes day-ahead energy management and primary-frequency response within a single, physics-informed control stack. A head-aware supervisory layer shifts charge–discharge thresholds via a linear SOC-head surrogate and enforces explicit anti-chatter measures (deadband, dwell, ramp limits). On top, an SOC-gated droop layer delivers frequency support while honoring actuator and energy constraints. The model is exercised over five 24-h scenarios: variable and sustained wind, fast fluctuations, low-head (offline) operation, and a frequency event, and is evaluated using discharged, curtailed and unserved energy, round-trip-efficiency change, equivalent full cycles (EFCs), switching events, and frequency metrics. Under nominal head, reservoirs sized to avoid day-ahead limitation render head penalties non-binding; baseline and proposed policies yield near-identical Eout, Ecurt, and Edef while chatter is restrained. Under low head the controller correctly suppresses generation, shifting performance into Edef without destabilizing modes. During the frequency event the framework preserves primary capability (nadir ≈ 49.85 Hz, RoCoF ≈ −0.023 Hz/s, recovery < 1 min, droop-support energy ≈ 0.0062 MWh), matching the baseline. Sensitivity-guided tuning exposes a reproducible parameter set (droop ≈ 4 MW/Hz; deadband 0.05 Hz; SOC thresholds 0.2–0.3 and 0.7–0.8; head-gain ≈ 0.05) that balances prudence and responsiveness and transfers directly to islanded or weak grids. The contribution is an explicit head-aware energy policy unified with an SOC-gated droop in a single reproducible model, achieving baseline-equivalent frequency performance without optimization overhead and enabling transparent, physics-based tuning.
- Open Access
- 17 March 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Enhanced current reference generation for PMSG-based wind systems using modified delayed signal cancellation
- 17 March 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Open AccessEnhanced current reference generation for PMSG-based wind systems using modified delayed signal cancellation
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Application of Superconducting Magnetic Energy Storage to Compensate the Pitch System Delay in Output Power Smoothing of Wind Turbines
Wind power is one of the most widely available renewable energy sources (RES). However, due to the intermittent nature of wind, the output power of wind turbines (WTs) is always variable. In WTs, at speeds lower than the rated wind speed, the goal is to maximise the power extracted from the wind. At higher wind speeds, the goal is to keep the WT's power constant at rated value; that is typically done by the WT's pitch control system. The operation of the pitch system has a delay due to WT's blades and rotor inertia and limited pitch rate, which may lead to output power fluctuations. Superconducting magnetic energy storage (SMES) has fast response and high efficiency. This paper explores the application of SMES to compensate for the pitch system delay in output power smoothing of a permanent magnet synchronous generator (PMSG)‐based WT. It is verified that the SMES properly compensates for the pitch lag by absorbing the surplus power and releasing it at power shortage intervals, particularly when pitch control returns the blades to their initial position. In the meantime, the pitch system reduces the SMES coil current and prevents it from saturation, which allows selecting an optimal/practical coil size for the SMES.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessApplication of Superconducting Magnetic Energy Storage to Compensate the Pitch System Delay in Output Power Smoothing of Wind Turbines
Wind power is one of the most widely available renewable energy sources (RES). However, due to the intermittent nature of wind, the output power of wind turbines (WTs) is always variable. In WTs, at speeds lower than the rated wind speed, the goal is to maximise the power extracted from the wind. At higher wind speeds, the goal is to keep the WT's power constant at rated value; that is typically done by the WT's pitch control system. The operation of the pitch system has a delay due to WT's blades and rotor inertia and limited pitch rate, which may lead to output power fluctuations. Superconducting magnetic energy storage (SMES) has fast response and high efficiency. This paper explores the application of SMES to compensate for the pitch system delay in output power smoothing of a permanent magnet synchronous generator (PMSG)‐based WT. It is verified that the SMES properly compensates for the pitch lag by absorbing the surplus power and releasing it at power shortage intervals, particularly when pitch control returns the blades to their initial position. In the meantime, the pitch system reduces the SMES coil current and prevents it from saturation, which allows selecting an optimal/practical coil size for the SMES.
- 1 May 2020
- Published by Elsevier in Renewable Energy
- Vol. 151, 750-763
Enhancing the net energy of wind turbine using wind prediction and economic NMPC with high-accuracy nonlinear WT models
- 1 May 2020
- Published by Elsevier in Renewable Energy
- Vol. 151, 750-763
Enhancing the net energy of wind turbine using wind prediction and economic NMPC with high-accuracy nonlinear WT models
- Open Access
- 15 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (7) , 1037-1049
Social welfare maximisation of market based wind integrated power systems by simultaneous coordination of transmission switching and demand response programs
The non‐preventable ever‐increasing rate of wind power generation in market‐based power systems faces the operators with challenging situations for making optimal decisions. So, it is essential to equip the operators with applicable control strategies and further corresponding control facilities. Moreover, the high‐priority of cheap wind power utilisation increases the probability of transmission lines congestion. Therefore, different solutions such as transmission switching (TS) and demand response (DR) programs have been recently introduced to manage the intermittent wind power generations. Accordingly, this study addresses the social welfare maximisation problem with coordinated control of TS and DR facilities to handle the regarding uncertainties using yet another linear matrix inequality parser (YALMIP). In fact, rapid algorithm and powerful employed solvers as well as simplicity of use, make YALMIP a practical modelling and optimisation toolbox. In this respect, the MOSEK solver is preferred by YALMIP to solve the proposed mixed integer linear programming problem. In addition, wind power uncertainty is modelled using the discrete‐time Markov chain approach and optimisations are performed on the 8‐bus and the large‐scale IEEE 118‐bus test systems. Results show that the proposed control strategy is highly capable of maximising social welfare by determining the optimal control commands in a real‐time manner.
- 15 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (7) , 1037-1049
Open AccessSocial welfare maximisation of market based wind integrated power systems by simultaneous coordination of transmission switching and demand response programs
The non‐preventable ever‐increasing rate of wind power generation in market‐based power systems faces the operators with challenging situations for making optimal decisions. So, it is essential to equip the operators with applicable control strategies and further corresponding control facilities. Moreover, the high‐priority of cheap wind power utilisation increases the probability of transmission lines congestion. Therefore, different solutions such as transmission switching (TS) and demand response (DR) programs have been recently introduced to manage the intermittent wind power generations. Accordingly, this study addresses the social welfare maximisation problem with coordinated control of TS and DR facilities to handle the regarding uncertainties using yet another linear matrix inequality parser (YALMIP). In fact, rapid algorithm and powerful employed solvers as well as simplicity of use, make YALMIP a practical modelling and optimisation toolbox. In this respect, the MOSEK solver is preferred by YALMIP to solve the proposed mixed integer linear programming problem. In addition, wind power uncertainty is modelled using the discrete‐time Markov chain approach and optimisations are performed on the 8‐bus and the large‐scale IEEE 118‐bus test systems. Results show that the proposed control strategy is highly capable of maximising social welfare by determining the optimal control commands in a real‐time manner.
- 1 June 2016
- Published by Elsevier in Energy Conversion and Management
- Vol. 118, 387-398
Optimal wind energy penetration in power systems: An approach based on spatial distribution of wind speed
- 1 June 2016
- Published by Elsevier in Energy Conversion and Management
- Vol. 118, 387-398
Optimal wind energy penetration in power systems: An approach based on spatial distribution of wind speed
- 1 December 2014
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 63, 44-50
Optimal output power of not properly designed wind farms, considering wake effects
- 1 December 2014
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 63, 44-50
Optimal output power of not properly designed wind farms, considering wake effects