CTCharles Tremblay-Darveau

Charles Tremblay-Darveau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Charles Tremblay-Darveau has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Frequency Nonlinear Doppler Contrast-Enhanced Ultrasound Imaging of Blood Flow

    by Matthew Bruce, Alex Hannah, Ryan Hammond, Zin Z. Khaing, Charles Tremblay-Darveau, Peter N. Burns, Christoph P. Hofstetter

    Current methods for in-vivo microvascular imaging (7.5MHz) are able to visualize smaller vasculature, however are still limited in the segmentation of lower velocity blood flow from moving tissue. Contrast enhanced ultrasound (CEUS) has been successful in visualizing changes in microvascular flow at conventional diagnostic ultrasound imaging frequencies (<7.5MHz). However, conventional CEUS approaches at elevated frequencies have met with limited success, due inpart to the diminishing microbubble response with frequency. We apply a plane-wave acquisition combined with non-linear Doppler processing of ultrasound contrast agents at 15MHz to improve resolution of microvascular blood flow, while compensating for reduced microbubble response. This planewave Doppler approach of imaging ultrasound contrast agents also enables simultaneous detection and separation of blood flow in the microcirculation and higher velocity flow in the larger vasculature. We apply singular value decomposition filtering on the non-linear Doppler signal to orthogonally separate the more stationary lower velocity flow in the microcirculation and higher velocity flow in the larger vasculature. This orthogonal separation was also utilized to improve time intensity curve analysis of the microcirculation, by removing higher velocity flow corrupting bolus kinetics. We demonstrate the utility of this imaging approach in a rat spinal cord injury model, requiring sub-millimeter resolution.


  • SUSHI: Sparsity-Based Ultrasound Super-Resolution Hemodynamic Imaging

    by Avinoam Bar-Zion, Oren Solomon, Charles Tremblay-Darveau, Dan Adam, Yonina C. Eldar

    Identifying and visualizing vasculature within organs and tumors has major implications in managing cardiovascular diseases and cancer. Contrast-enhanced ultrasound scans detect slow-flowing blood, facilitating noninvasive perfusion measurements. However, their limited spatial resolution prevents the depiction of microvascular structures. Recently, super-localization ultrasonography techniques have surpassed this limit. However, they require long acquisition times of several minutes, preventing the detection of hemodynamic changes. We present a fast super-resolution method that exploits sparsity in the underlying vasculature and statistical independence within the measured signals. Similar to super-localization techniques, this approach improves the spatial resolution by up to an order of magnitude compared to standard scans. Unlike super-localization methods, it requires acquisition times of only tens of milliseconds. We demonstrate a temporal resolution of ~25 Hz, which may enable functional super-resolution imaging deep within the tissue, surpassing the temporal resolution limitations of current super-resolution methods, e.g., in neural imaging. The subsecond acquisitions make our approach robust to motion artifacts, simplifying in vivo use of super-resolution ultrasound.


  • 3-D Perfusion Imaging Using Principal Curvature Detection Rendering

    by Charles Tremblay-Darveau, Paul S. Sheeran, Cindy Kim Vu, Ross Williams, Matthew Bruce, Peter N. Burns

    Three-dimensional contrast-enhanced ultrasound (CEUS) imaging presents a clear advantage over its 2D counterpart in detecting and characterizing suspicious lesions as it properly surveys the inherent heterogeneity of tumours. However, 3D CEUS is also slow compared to 2D CEUS and tends to undersample the microbubble wash-in. This makes it difficult to resolve the feeding vessels, an important oncogenic marker, from the background perfusion cloud. Contrast-enhanced Doppler is helpful in isolating this conduit flow, but requires too many pulses in conventional line-by-line beamforming design. Recent breakthroughs in plane-wave imaging have greatly accelerated the volumetric imaging frame rate, but volumetric Doppler angiography still remains challenging when considering realtime limitations on the Doppler ensemble length. In this work, we demonstrate the feasibility of volumetric CEUS angiography subjected to real-time imaging constraints. Namely, we show how principal curvature detection can significantly improve 3D rendering of relatively noisy ultrasound angiograms without degrading the spatial resolution while subjected to a reasonable Doppler ensemble size. Singular Value Decomposition is also shown to be capable of identifying the quasi-stationary capillary perfusion.


  • The Role of Microbubble Echo Phase Lag in Multipulse Contrast-Enhanced Ultrasound Imaging

    by Charles Tremblay-Darveau, Paul S. Sheeran, Cindy Kim Vu, Ross Williams, Ze Zhang, Matthew Bruce, Peter N. Burns

    In this paper, we assess the importance of microbubble shell composition for contrast-enhanced imaging sequences commonly used on clinical scanners. While the gas core dynamics are primarily responsible for the nonlinear harmonic response of microbubbles at diagnostic pressures, it is now understood that the shell rheology plays a dominant role in the nonlinear response of microbubbles subjected to low acoustic pressures. Of particular interest here, acoustic pressures of tens of kPa can cause a reversible phase transition of the phospholipid coatings from a stiff elastic organized state, to a less stiff, disorganized buckled state. Such a transition from an elastic to buckled shell induces a steep variation of the shell elasticity, which alters the microbubble acoustic scattering properties. We demonstrate in this work that this mechanism plays a dominant role in contrast pulse sequences that modulate the amplitude of the insonifying pulse pressure. The contrast-to-tissue ratio for amplitude modulation (AM), pulse inversion (PI) and amplitude modulation pulse inversion (AMPI) is measured in vitro for Definity, Sonazoid, both lipid-encapsulted microbubbles, and the albumin-coated Optison. It is found that pulse sequences using amplitude modulation significantly enhanced the nonlinear response of all studied microbubbles compared to pulse inversion (up to 15 dB more) when low insonation pressures under 200kPa were used. Further investigation reveals that the origin of the hyper-echoicity is a small phase lag occurring between the echoes from the full and half amplitude driving pulses, and that the effect could be attributed to the shell-softening dynamics of lipid and albumin coating. We assess that this additional phase in microbubble ultrasound scattering can have a dominant role in the contrastto- tissue ratio achieved in contrast sequences using amplitude modulation. We also show that the pressure dependent phase lag is a specific marker for microbubbles, with no equivalent in tissue, which can be used to segment microbubbles from tissue harmonics and significantly increase the CTR.


  • Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator

    by Charles Tremblay-Darveau, Avinoam Bar-Zion, Ross Williams, Paul S. Sheeran, Laurent Milot, Thanasis Loupas, Dan Adam, Matthew Bruce, Peter N. Burns

    While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the noise due to the time-gain compensation and the received beamforming aperture ultimately limits sensitivity. In this paper, we demonstrate that the performance of power Doppler imaging can be improved by leveraging the higher lags of the autocorrelation [e.g., R(1), R(2),...] instead of the signal power (R(0)). As noise is completely uncorrelated from pulse-to-pulse while the flow signal remains correlated significantly longer, weak signals just above the noise floor can be made visible through the reduction of the noise floor. Finally, as coherence decreases proportionally with respect to velocity, we demonstrate how signal coherence can be targeted to separate flows of different velocities. For instance, we show how long-time-range coherence of microbubble contrast-enhanced flow specifically isolates slow capillary perfusion (as opposed to conduit flow).


  • Future Prospects for Contrast Ultrasound

    by Peter N. Burns, Charles Tremblay-Darveau, Paul Sheeran

  • Concepts and Tradeoffs in Velocity Estimation With Plane-Wave Contrast-Enhanced Doppler

    by Charles Tremblay-Darveau, Ross Williams, Paul S. Sheeran, Laurent Milot, Matthew Bruce, Peter N. Burns

    While long Doppler ensembles are, in principle, beneficial for velocity estimates, short acoustic pulses must be used in microbubble contrast-enhanced (CE) Doppler to mitigate microbubble destruction. This introduces inherent tradeoffs in velocity estimates with autocorrelators, which are studied here. A model of the autocorrelation function adapted to the microbubble Doppler signal accounting for transit time, the echo frequency uncertainty, and contrast-agent destruction is derived and validated in vitro. It is further demonstrated that a local measurement of the center frequency of the microbubble echo is essential in order to avoid significant bias in velocity estimates arising from the linear and nonlinear frequency-dependent scattering of microbubbles and compensate for the inherent speckle nature of the received echo frequency. For these reasons, broadband Doppler estimators (2-D autocorrelator and Radon projection) are better suited than simpler narrow-band estimators (1-D autocorrelator and 1-D Fourier transform) for CE flow assessment. A case study of perfusion in a VX-2 carcinoma using CE plane-wave Doppler is also shown. We demonstrate that even when considering all uncertainties associated with microbubble-related decorrelation (destruction, pulse bandwidth, transit time, and flow gradient) and the need for real-time imaging, a coefficient of variation of 4% on the axial velocity is achievable with plane-wave imaging.


  • Combined perfusion and doppler imaging using plane-wave nonlinear detection and microbubble contrast agents

    by Charles Tremblay-Darveau, Ross Williams, Laurent Milot, Matthew Bruce, Peter N. Burns

    Plane-wave imaging offers image acquisition rates at the pulse repetition frequency, effectively increasing the imaging frame rates by up to two orders of magnitude over conventional line-by-line imaging. This form of acquisition can be used to achieve very long ensemble lengths in nonlinear modes such as pulse inversion Doppler, which enables new imaging trade-offs that were previously unattainable. We first demonstrate in this paper that the coherence of microbubble signals under repeated exposure to acoustic pulses of low mechanical index can be as high as 204 ± 5 pulses, which is long enough to allow an accurate power Doppler measurement. We then show that external factors, such as tissue acceleration, restrict the detection of perfusion at the capillary level with linear Doppler, even if long Doppler ensembles are considered. Hence, perfusion at the capillary level can only be detected with ultrasound through combined microbubbles and Doppler imaging. Finally, plane-wave contrast-enhanced power and color Doppler are performed on a rabbit kidney in vivo as a proof of principle. We establish that long pulse-inversion Doppler sequences and conventional wall-filters can create an image that simultaneously resolves both the vascular morphology of veins and arteries, and perfusion at the capillary level with frame rates above 100 Hz.


  • Measuring Absolute Blood Pressure Using Microbubbles

    by Charles Tremblay-Darveau, Ross Williams, Peter N. Burns