Abbas Lotfi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abbas Lotfi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Nicola Chiesa
Statoil, Trondheim, Norway
3 shared publicationsEbrahim Rahimpour
ABBAG Bad Honnef, Germany
2 shared publicationsHans Kr. Hoidalen
Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications- Sergey E. Zirka
Department of Physics and Technology, Dnipro National University, Dnipro, Ukraine
2 shared publications - Yuriy I. Moroz
Department of Physics and Technology, Dnipro National University, Dnipro, Ukraine
2 shared publications - Alireza Mousavi
College of Engineering, Design and Physical Sciences, Brunel University, Uxbridge UB8 3PH, UK
1 shared publication
Latest Publications
- 20 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (4) , 2081-2090
Practical Experience in Using a Topological Model of a Core-Type Three-Phase Transformer—No-Load and Inrush Conditions
This paper describes an experience in transformer modeling based on open-circuit test data obtained for a wide range of terminal voltages on the low-voltage side and inrush current measurements on the high-voltage side carried out for different residual fluxes of a 300-kVA transformer. The core-type transformer model is based on a dynamic hysteresis model, which is employed individually in the legs and yokes. We start with the case where the core geometry and winding turns are known when fitting the model. The method proposed is then extended to the case where only the nameplate data and the measured no-load losses and currents are available. For this latter case, an optimization model fitting is developed.
- 20 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (4) , 2081-2090
Practical Experience in Using a Topological Model of a Core-Type Three-Phase Transformer—No-Load and Inrush Conditions
This paper describes an experience in transformer modeling based on open-circuit test data obtained for a wide range of terminal voltages on the low-voltage side and inrush current measurements on the high-voltage side carried out for different residual fluxes of a 300-kVA transformer. The core-type transformer model is based on a dynamic hysteresis model, which is employed individually in the legs and yokes. We start with the case where the core geometry and winding turns are known when fitting the model. The method proposed is then extended to the case where only the nameplate data and the measured no-load losses and currents are available. For this latter case, an optimization model fitting is developed.
- 1 September 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 138, 33-40
Benchmarking of hysteretic elements in topological transformer model
- 1 September 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 138, 33-40
Benchmarking of hysteretic elements in topological transformer model
- 1 September 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 138, 18-24
Effect of DC biasing in 3-legged 3-phase transformers taking detailed model of off-core path into account
- 1 September 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 138, 18-24
Effect of DC biasing in 3-legged 3-phase transformers taking detailed model of off-core path into account
- 29 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (5) , 1-4
Characterization of Magnetic Losses in the Transformer Tank Steel
The transformer tank is normally built of construction steel and has relatively large thickness of 1.2 mm for distribution up to 12 mm for large power transformers. In such thick materials, skin effect becomes much more significant than thin materials due to both frequency and non-linearity. The flux density in the tank can vary in a wide range of some mT to 1800 mT (in the case of having high zero sequence flux) leading to a large variation in the permeability and, consequently, in skin depth. Since the losses are high, the temperature rise can also be a main problem influencing the conductivity that must be considered in the loss calculations. The main contribution of this paper is to study the magnetic losses in the transformer tank steel through the measurements and finite difference-based numerical calculations. Using the loss separation principle, different loss mechanisms are investigated, and the behavior of each at the different level of inductions and frequencies is studied.
- 29 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (5) , 1-4
Characterization of Magnetic Losses in the Transformer Tank Steel
The transformer tank is normally built of construction steel and has relatively large thickness of 1.2 mm for distribution up to 12 mm for large power transformers. In such thick materials, skin effect becomes much more significant than thin materials due to both frequency and non-linearity. The flux density in the tank can vary in a wide range of some mT to 1800 mT (in the case of having high zero sequence flux) leading to a large variation in the permeability and, consequently, in skin depth. Since the losses are high, the temperature rise can also be a main problem influencing the conductivity that must be considered in the loss calculations. The main contribution of this paper is to study the magnetic losses in the transformer tank steel through the measurements and finite difference-based numerical calculations. Using the loss separation principle, different loss mechanisms are investigated, and the behavior of each at the different level of inductions and frequencies is studied.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Analytical hysteresis model for numerical electromagnetic simulations
Modelling of hysteresis in soft magnetic materials is necessary for accurate transient studies of transformers and electrical machines. The phenomena such as magnetization inrush currents and ferroresonance are directly resultants of the hysteresis properties. A proper model for numerical transient analyses should be easy regarding implementation and parameter estimation. A differential hysteresis model derived from the Preisach classic theory was introduced. The model has accuracy comparable with Preisach models. Furthermore, in numerical simulations it can be inverted easily. In this paper, a practical method for estimation of the model functions by analytical expressions is suggested. The required input data is decreased to only the major hysteresis loop that is usually available that is easy to measure. Also, details of the numerical implementation are described. The presented method is verified by experimental measurements on several grain oriented and non-oriented electrical steels.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Analytical hysteresis model for numerical electromagnetic simulations
Modelling of hysteresis in soft magnetic materials is necessary for accurate transient studies of transformers and electrical machines. The phenomena such as magnetization inrush currents and ferroresonance are directly resultants of the hysteresis properties. A proper model for numerical transient analyses should be easy regarding implementation and parameter estimation. A differential hysteresis model derived from the Preisach classic theory was introduced. The model has accuracy comparable with Preisach models. Furthermore, in numerical simulations it can be inverted easily. In this paper, a practical method for estimation of the model functions by analytical expressions is suggested. The required input data is decreased to only the major hysteresis loop that is usually available that is easy to measure. Also, details of the numerical implementation are described. The presented method is verified by experimental measurements on several grain oriented and non-oriented electrical steels.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Calculation of off-core inductance in dual-circuit model of transformer
Zero sequence magnetic flux, generated in transformer core in different operation cases, is forced out of the core including the oil gap and the tank. These off-core flux paths can be represented by inductances in a duality transformation based electrical transformer model. These off-core inductances mainly determine the zero sequence impedance that is vital in analyzing a transformer subjected to the GIC event or unbalanced voltages. Estimation of these inductances is one of the challenges in identification of the electric equivalent circuit. The main contribution of this paper is to present an approach for calculation of the mentioned off-core inductances based on 2D-FEM. Since the transformer structure is not symmetric for off-core flux path, 3D-FE analysis is also used to evaluate and improve the presented method. The results calculated for a 3-leg 3-phase transformer have a good agreement with the values obtained from empirical equations typically adopted by manufacturer.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Calculation of off-core inductance in dual-circuit model of transformer
Zero sequence magnetic flux, generated in transformer core in different operation cases, is forced out of the core including the oil gap and the tank. These off-core flux paths can be represented by inductances in a duality transformation based electrical transformer model. These off-core inductances mainly determine the zero sequence impedance that is vital in analyzing a transformer subjected to the GIC event or unbalanced voltages. Estimation of these inductances is one of the challenges in identification of the electric equivalent circuit. The main contribution of this paper is to present an approach for calculation of the mentioned off-core inductances based on 2D-FEM. Since the transformer structure is not symmetric for off-core flux path, 3D-FE analysis is also used to evaluate and improve the presented method. The results calculated for a 3-leg 3-phase transformer have a good agreement with the values obtained from empirical equations typically adopted by manufacturer.
- 1 August 2013
- Published by Elsevier in Electric Power Systems Research
- Vol. 101, 63-70
Optimum design of core blocks and analyzing the fringing effect in shunt reactors with distributed gapped-core
- 1 August 2013
- Published by Elsevier in Electric Power Systems Research
- Vol. 101, 63-70
Optimum design of core blocks and analyzing the fringing effect in shunt reactors with distributed gapped-core
- 22 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (4) , 1673-1676
Design Optimization of Gapped-Core Shunt Reactors
Shunt reactors are important components for the development of UHV power systems since they compensate large capacitive currents generated by HV transmission lines over great distances. Shunt reactors can also limit over voltages resulting from load shedding operations or from a line-to-ground fault. With regard to construction, shunt reactors are designed in distributed gapped-core which has one winding and a core divided into several laminated magnetic steel disks separated by air-gap wedges. The Volume of the gap is in relation with reactive power (Q) of the reactor and maximum magnetic flux density (B m ) as well. After calculating the gap volume, the way for separating of the gap area (Ag) and length (ΣIg) is an important matter. It plays main role in reactor dimensions, used materials and power losses. In this paper a method based on minimizing the cost is presented for selecting the gap area and length by finding an optimum value for Ag/ΣIg ratio with constant volume constraint.
- 22 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (4) , 1673-1676
Design Optimization of Gapped-Core Shunt Reactors
Shunt reactors are important components for the development of UHV power systems since they compensate large capacitive currents generated by HV transmission lines over great distances. Shunt reactors can also limit over voltages resulting from load shedding operations or from a line-to-ground fault. With regard to construction, shunt reactors are designed in distributed gapped-core which has one winding and a core divided into several laminated magnetic steel disks separated by air-gap wedges. The Volume of the gap is in relation with reactive power (Q) of the reactor and maximum magnetic flux density (B m ) as well. After calculating the gap volume, the way for separating of the gap area (Ag) and length (ΣIg) is an important matter. It plays main role in reactor dimensions, used materials and power losses. In this paper a method based on minimizing the cost is presented for selecting the gap area and length by finding an optimum value for Ag/ΣIg ratio with constant volume constraint.
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1515-1517
Identification of KEMA arc model parameters in high voltage circuit breaker by using of genetic algorithm
A circuit breaker is properly modeled by KEMA model. This model is created on the basis of Cassie and Mayr classical equations. The precision of this model depends strongly on the precision of its parameters. The calculation of these parameters needs the complex physical analysis and structural data of C.B. In this paper a novel method based on genetic algorithm (GA) is introduced as a method to identify the parameters of KEMA model by using a simple experiment.
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1515-1517
Identification of KEMA arc model parameters in high voltage circuit breaker by using of genetic algorithm
A circuit breaker is properly modeled by KEMA model. This model is created on the basis of Cassie and Mayr classical equations. The precision of this model depends strongly on the precision of its parameters. The calculation of these parameters needs the complex physical analysis and structural data of C.B. In this paper a novel method based on genetic algorithm (GA) is introduced as a method to identify the parameters of KEMA model by using a simple experiment.