CWCraig Woody

Craig Woody

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Craig Woody has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Review of Particle Physics *

    by F. Takahashi, K. Hikasa, Y. Sumino, M. Tanabashi, J. Tanaka, M. Yokoyama, K. Agashe, G. Aielli, B. C. Allanach, J. Alvarez-Muñiz, et al.

    The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised. The Review is divided into two volumes. Volume 1 includes the Summary Tables and 96 review articles. Volume 2 consists of the Particle Listings and contains also 22 reviews that address specific aspects of the data presented in the Listings. The complete Review (both volumes) is published online on the website of the Particle Data Group ( pdg.lbl.gov ) and in a journal. Volume 1 is available in print as the PDG Book. A Particle Physics Booklet with the Summary Tables and essential tables, figures, and equations from selected review articles is available in print, as a web version optimized for use on phones, and as an Android app. The PDG API (Application Programming Interface) provides access to the data published in the Review in machine-readable format.


  • Measurement of the transverse energy density in Au+Au collisions at sNN=200GeV with the sPHENIX detector

    by M. I. Abdulhamid, U. Acharya, E. R. Adams, G. Adawi, C. A. Aidala, Y. Akiba, M. Alfred, S. Ali, A. Alsayegh, S. Altaf, et al.


  • Open Access

    Measurement of charged hadron multiplicity in Au+Au collisions at $ \sqrt{{\textrm{s}}_{\textrm{NN}}} $ = 200 GeV with the sPHENIX detector

    by M Abdulhamid, U Acharya, E Adams, G Adawi, C Aidala, Y Akiba, M Alfred, S Ali, A Alsayegh, S Altaf, et al.

    The pseudorapidity distribution of charged hadrons produced in Au+Au collisions at a center-of-mass energy of $$ \sqrt{{\textrm{s}}_{\textrm{NN}}} $$ s NN = 200 GeV is measured using data collected by the sPHENIX detector. Charged hadron yields are extracted by counting cluster pairs in the inner and outer layers of the Intermediate Silicon Tracker, with corrections applied for detector acceptance, reconstruction efficiency, combinatorial pairs, and contributions from secondary decays. The measured distributions cover |η| < 1.1 across various centralities, and the average pseudorapidity density of charged hadrons at mid-rapidity is compared to predictions from Monte Carlo heavy-ion event generators. This result, featuring full azimuthal coverage at mid-rapidity, is consistent with previous experimental measurements at the Relativistic Heavy Ion Collider, thereby supporting the broader sPHENIX physics program.


  • A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

    by C. Perez-Lara, S. Aune, B. Azmoun, K. Dehmelt, A. Deshpande, W. Fan, P. Garg, T. K. Hemmick, M. Kebbiri, A. Kiselev, et al.

    Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently used with micropattern gas detectors (MPGDs) to reconstruct high-precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring strips. However, to effectively extract the inherent positional information, the lateral spacing of the straight strips must be comparable to or preferably smaller than the full extent of the incident charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the incident charge with a pitch appreciably larger than the charge cloud. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a near-uniform detector response along and perpendicular to the sensitive coordinate, without the need for so-called “pad response functions,” while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag-shaped anode patterns optimized for various MPGDs, including gas electron multiplyer (GEM), Micromegas, and micro-resistive-well ( $\mu $ RWELL) and compared this performance with the same detectors equipped with straight strips of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.


  • PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-Compatible PET System

    by Shouyi Wei, Nandita Joshi, Michael Salerno, David Ouellette, Lemise Saleh, Christine Delorenzo, Craig Woody, David Schlyer, Martin L. Purschke, Jean-Francois Pratte, et al.

    We used a compact, high-resolution, and magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) camera (VersaPET) to assess the feasibility of measuring the image-derived input function (IDIF) from arteries in the leg with the ultimate goal of enabling fully quantitative PET brain imaging without blood sampling. We used this approach in five 18 F-FDG PET/MRI brain studies in which the input function was also acquired using the gold standard of serial arterial blood sampling. After accounting for partial volume, dispersion, and calibration effects, we compared the metabolic rates of glucose (MRglu) quantified from VersaPET IDIFs in 80 brain regions to those using the gold standard and achieved a bias and variability of $R^{2} > 0.97$ ) against the gold standard across regions. The results of this preliminary study are promising and support further studies to optimize methods, validate in a larger cohort, and extend to the modeling of other radiotracers.


  • Design and Beam Test Results for the 2-D Projective sPHENIX Electromagnetic Calorimeter Prototype

    by C. A. Aidala, S. Altaf, R. Belmont, S. Boose, D. Cacace, M. Connors, E. Desmond, J. Frantz, E. A. Gamez, N. Grau, et al.

    sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of quantum chromodynamics (QCP) matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of Δη × Δφ = 0.2 × 0.2 centered at pseudo-rapidity η = 1. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2-D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position-dependent energy correction and a beam profile correction. Two separate position-dependent corrections were considered. The EMCal energy resolution was found to be σ(E)/〈E〉 = 3.5(0.1) ⊕ 13.3(0.2)/√E based on the hodoscope position-dependent correction, and σ(E)/〈E〉 = 3.0(0.1) ⊕ 15.4(0.3)/√E based on the cluster position-dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.


  • Toward 100 ps Coincidence Time Resolution Using Multiple Timestamps in Depth-Encoding PET Modules: A Monte Carlo Simulation Study

    by Andy LaBella, Stefaan Tavernier, Craig Woody, Martin Purschke, Wei Zhao, Amir H. Goldan

    Coincidence time resolution (CTR) in modern time-of-flight (TOF) PET scanners is limited by properties of the detector system, namely scintillator size and material, as well as single-photon time resolution (SPTR) and photon detection efficiency of the readout pixels. Recent studies have demonstrated the effectiveness of incorporating depth of interaction (DOI) information into TOF readout to improve CTR. Having multiple timestamps per event has also been shown to improve CTR through leading edge slope estimation. We propose using convolutional neural networks (CNNs) to improve CTR in PET modules with excellent DOI resolution and access to multiple timestamps per event. Monte Carlo simulations were used to generate PET-like data on 4-to-1 coupled single-ended readout depth-encoding modules with 1.5×1.5×20 mm LYSO crystals and prismatoid light guide arrays. We trained our CNN to perform TOF estimation between the 2 simulated modules with and without DOI information, as well as with single and multiple timestamps. The results show using DOI and multiple timestamps provides more than 50% improvement in CTR over standard single timestamp acquisition when sufficient SPTR (<100 ps) is available. Our CNN demonstrates the importance of having multiple timestamps and excellent DOI resolution for improving CTR in practical depth-encoding PET modules.


  • Design Studies of High-Resolution Readout Planes Using Zigzags With GEM Detectors

    by B. Azmoun, S. Aune, K. Dehmelt, A. Deshpande, W. Fan, P. Garg, T. K. Hemmick, M. Kebbiri, A. Kiselev, I. Mandjavidze, et al.

    We have developed highly interleaved zigzag shaped electrodes for collecting charge on the readout plane of various micro-pattern gaseous detectors (MPGDs), including Gas Electron Multiplier (GEM) and Micromegas detectors. An optimized zigzag pad (or strip) anode can greatly enhance charge sharing among neighboring pads compared to traditional straight strip or rectangular pad designs and as a result can deliver excellent position resolution with minimal channel count, while exhibiting a virtually uniform response across the detector. We have systematically studied the effects of varying the parameters that define the zigzag geometry using simulations and have measured several PCBs comprising a range of zigzag designs. Recently we have employed laser ablation to generate zigzag patterns with pad-to-pad gaps smaller than 1 mil (or 25 μm). Reducing the gap well below the 3 mil limit imposed by traditional chemical etching has allowed the production of zigzag electrodes with unprecedentedly small feature sizes. In turn, laser etched zigzag PCBs were shown to exhibit markedly improved performance over earlier generation PCBs, with position resolutions below 50 μm for a 2 mm pitch. This paper will explore in detail the dependence of the position resolution on the structural parameters of a zigzag shaped anode, specifically for the case of a quadruple GEM detector.


  • Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

    by B. Azmoun, K. Dehmelt, T. K. Hemmick, R. Majka, H. N. Nguyen, M. Phipps, M. L. Purschke, N. Ram, W. Roh, D. Shangase, et al.


  • A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers

    by B. Biro, G. David, A. Fenyvesi, J. S. Haggerty, J. Kierstead, E. J. Mannel, T. Majoros, J. Molnar, F. Nagy, S. Stoll, et al.

    The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of multipixel photon counters from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at the Brookhaven National Laboratory and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10 8 to 10 12 n/cm 2 . The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This paper was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.