Toward 100 ps Coincidence Time Resolution Using Multiple Timestamps in Depth-Encoding PET Modules: A Monte Carlo Simulation Study
- 9 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 679-686
Abstract
Coincidence time resolution (CTR) in modern time-of-flight (TOF) PET scanners is limited by properties of the detector system, namely scintillator size and material, as well as single-photon time resolution (SPTR) and photon detection efficiency of the readout pixels. Recent studies have demonstrated the effectiveness of incorporating depth of interaction (DOI) information into TOF readout to improve CTR. Having multiple timestamps per event has also been shown to improve CTR through leading edge slope estimation. We propose using convolutional neural networks (CNNs) to improve CTR in PET modules with excellent DOI resolution and access to multiple timestamps per event. Monte Carlo simulations were used to generate PET-like data on 4-to-1 coupled single-ended readout depth-encoding modules with 1.5×1.5×20 mm LYSO crystals and prismatoid light guide arrays. We trained our CNN to perform TOF estimation between the 2 simulated modules with and without DOI information, as well as with single and multiple timestamps. The results show using DOI and multiple timestamps provides more than 50% improvement in CTR over standard single timestamp acquisition when sufficient SPTR (<100 ps) is available. Our CNN demonstrates the importance of having multiple timestamps and excellent DOI resolution for improving CTR in practical depth-encoding PET modules.Keywords
This publication has 53 references indexed in Scilit:
- Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elementsPhysics in Medicine & Biology, 2015
- Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with CaPhysics in Medicine & Biology, 2015
- Update on Time-of-Flight PET ImagingJournal of Nuclear Medicine, 2014
- Time resolution deterioration with increasing crystal length in a TOF-PET systemNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: an experimental and theoretical analysisJournal of Instrumentation, 2013
- A 4 × 4 × 416 digital SiPM array with 192 TDCs for multiple high-resolution timestamp acquisitionJournal of Instrumentation, 2013
- Accurate measurement of the rise and decay times of fast scintillators with solid state photon countersJournal of Instrumentation, 2012
- LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving timePhysics in Medicine & Biology, 2010
- Prospects for time-of-flight PET using LSO scintillatorIEEE Transactions on Nuclear Science, 1999
- Relation Between Surface Roughness and Specular Reflectance at Normal IncidenceJournal of the Optical Society of America, 1961