Gerhard Ulbricht
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerhard Ulbricht has a total of 196 co-authors. Here are the top co-authors by number of shared publications:
- Alexander B. Walter
Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA, USA
8 shared publications - Paul Szypryt
National Institute of Standards and Technology
8 shared publications B. Bumble
NASA Jet Propulsion Laboratory, Pasadena, California 91109, USA
6 shared publications- Mario De Lucia
Università di Pisa
6 shared publications S. R. Meeker
Department of Physics, University of California, Santa Barbara, California 93106, USA
6 shared publicationsB. A. Mazin
Department of Physics, University of California, Santa Barbara, California 93106, USA
5 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 3 February 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 706, A99
Spatially resolved broad-line region in a quasar at z = 4
We present the first near-infrared interferometric data of a QSO at z = 4. The K -band observations were performed with GRAVITY+ on the VLTI using all four UTs, detecting a differential phase signal that traces the spatially resolved kinematics for both the H β and H γ lines in the broad-line region (BLR). We fit the two lines simultaneously with an updated model that includes distinct rotating and conical outflowing components. For the best-fit model, more than 80% of the H I line emission from the BLR originates in an outflow with a velocity up to 10 4 km s −1 . This is oriented so that our line of sight is along an edge of the conical structure, which produces the prominent blue wing on the line profile. A combination of anisotropic line emission and mid-plane opacity leads to the single-sided phase signal. The model is able to qualitatively match both the outflowing C IV line profile and the systemic O I fluorescent emission. The black hole mass of 8 × 10 8 M ⊙ that we derive is the highest redshift black hole mass measurement to date obtained directly from BLR dynamics. It is an order of magnitude lower than that inferred from various single epoch scaling relations, and it implies that the accretion is highly super-Eddington. With reference to recent simulations, the data suggest that this QSO is emitting close to its radiative limit in a regime where strong outflows are expected around a polar conical region.
- 3 February 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 706, A99
Top Cited PapersOpen AccessSpatially resolved broad-line region in a quasar at z = 4
We present the first near-infrared interferometric data of a QSO at z = 4. The K -band observations were performed with GRAVITY+ on the VLTI using all four UTs, detecting a differential phase signal that traces the spatially resolved kinematics for both the H β and H γ lines in the broad-line region (BLR). We fit the two lines simultaneously with an updated model that includes distinct rotating and conical outflowing components. For the best-fit model, more than 80% of the H I line emission from the BLR originates in an outflow with a velocity up to 10 4 km s −1 . This is oriented so that our line of sight is along an edge of the conical structure, which produces the prominent blue wing on the line profile. A combination of anisotropic line emission and mid-plane opacity leads to the single-sided phase signal. The model is able to qualitatively match both the outflowing C IV line profile and the systemic O I fluorescent emission. The black hole mass of 8 × 10 8 M ⊙ that we derive is the highest redshift black hole mass measurement to date obtained directly from BLR dynamics. It is an order of magnitude lower than that inferred from various single epoch scaling relations, and it implies that the accretion is highly super-Eddington. With reference to recent simulations, the data suggest that this QSO is emitting close to its radiative limit in a regime where strong outflows are expected around a polar conical region.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-9
An Overview of Potential Medical Applications of Microwave Kinetic Inductance Detectors
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-9
Open AccessAn Overview of Potential Medical Applications of Microwave Kinetic Inductance Detectors
- 11 July 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (8) , 1-8
Measurement of optical absorption in granular aluminum thin films at room temperature
- 11 July 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (8) , 1-8
Measurement of optical absorption in granular aluminum thin films at room temperature
- Open Access
- 15 May 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 216 (1-2) , 175-184
Optimizing Ti/TiN Multilayers for UV, Optical and Near-IR Microwave Kinetic Inductance Detectors
Microwave Kinetic Inductance Detectors (MKIDs) combine significant advantages for photon detection like single photon counting, single pixel energy resolution, vanishing dark counts and µs time resolution with a simple design and the feasibility to scale up into the megapixel range. But high quality MKID fabrication remains challenging as established superconductors tend to either have intrinsic disadvantages, are challenging to deposit or require very low operating temperatures. As alternating stacks of thin Ti and TiN films have shown very impressive results for far-IR and sub-mm MKIDs, they promise significant improvements for UV, visible to near-IR MKIDs as well, especially as they are comparably easy to fabricate and control. In this paper, we present our ongoing project to adapt proximity coupled superconducting films for photon counting MKIDs. Some of the main advantages of Ti/TiN multilayers are their good control of critical temperature (Tc) and their great homogeneity of Tc even over large wafers, promising improved pixel yield especially for large arrays. We demonstrate the effect different temperatures during fabrication have on the detector performance and discuss excess phase noise observed caused by surface oxidization of exposed Si. Our first prototypes achieved photon energy resolving powers of up to 3.1 but turned out to be much too insensitive. As the work presented is still in progress, we also discuss further improvements planned for the near future.
- 15 May 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 216 (1-2) , 175-184
Open AccessOptimizing Ti/TiN Multilayers for UV, Optical and Near-IR Microwave Kinetic Inductance Detectors
Microwave Kinetic Inductance Detectors (MKIDs) combine significant advantages for photon detection like single photon counting, single pixel energy resolution, vanishing dark counts and µs time resolution with a simple design and the feasibility to scale up into the megapixel range. But high quality MKID fabrication remains challenging as established superconductors tend to either have intrinsic disadvantages, are challenging to deposit or require very low operating temperatures. As alternating stacks of thin Ti and TiN films have shown very impressive results for far-IR and sub-mm MKIDs, they promise significant improvements for UV, visible to near-IR MKIDs as well, especially as they are comparably easy to fabricate and control. In this paper, we present our ongoing project to adapt proximity coupled superconducting films for photon counting MKIDs. Some of the main advantages of Ti/TiN multilayers are their good control of critical temperature (Tc) and their great homogeneity of Tc even over large wafers, promising improved pixel yield especially for large arrays. We demonstrate the effect different temperatures during fabrication have on the detector performance and discuss excess phase noise observed caused by surface oxidization of exposed Si. Our first prototypes achieved photon energy resolving powers of up to 3.1 but turned out to be much too insensitive. As the work presented is still in progress, we also discuss further improvements planned for the near future.
- Open Access
Limitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
Open AccessLimitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
- Open Access
- 1 December 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (12)
Limitations to the energy resolution of single-photon sensitive microwave kinetic inductance detectors
This paper describes the energy resolution of microwave kinetic inductance detectors and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, ΔE, that the detector can identify and, as such, is of critical importance for many applications. Limits to the energy resolution caused by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
- 1 December 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (12)
Open AccessLimitations to the energy resolution of single-photon sensitive microwave kinetic inductance detectors
This paper describes the energy resolution of microwave kinetic inductance detectors and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, ΔE, that the detector can identify and, as such, is of critical importance for many applications. Limits to the energy resolution caused by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
- Open Access
- 17 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2671
Applications for Microwave Kinetic Induction Detectors in Advanced Instrumentation
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.
- 17 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2671
Open AccessApplications for Microwave Kinetic Induction Detectors in Advanced Instrumentation
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.
- Open Access
- 13 December 2020
- Published by SPIE-Intl Soc Optical Eng
- p. 116
Multiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance
SPIE Digital Library Proceedings
- 13 December 2020
- Published by SPIE-Intl Soc Optical Eng
- p. 116
Open AccessMultiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance
SPIE Digital Library Proceedings
- 16 April 2018
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 130 (988) , 065001
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy
- 16 April 2018
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 130 (988) , 065001
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy
- 10 October 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (21) , 25894-25909
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800–1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 µm.
- 10 October 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (21) , 25894-25909
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800–1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 µm.