Mario De Lucia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mario De Lucia has a total of 651 co-authors. Here are the top co-authors by number of shared publications:
- Gerhard Ulbricht
Department of Physics, Maynooth University, Maynooth, Ireland
6 shared publications - Tommaso Lari
Università di Pisa
6 shared publications - Giovanni Signorelli
Università di Pisa
5 shared publications - Andrea Tartari
INFN Sezione di Pisa
4 shared publications - Alessandro Monfardini
Université Grenoble Alpes
3 shared publications - Angelo Cruciani
Istituto Nazionale di Fisica Nucleare – Sezione di Roma
3 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Background of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Open AccessBackground of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 9501006
TES Proton Irradiation Result Analysis for Future Space Applications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 9501006
TES Proton Irradiation Result Analysis for Future Space Applications
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-6
Compatibility Study of the LiteBIRD SQUID Controller Unit With a Dual-Stage SQUID Amplification Chain
The LiteBIRD satellite will map the polarisation of the Cosmic Microwave Background (CMB) with unprecedented sensitivity by means of antenna-coupled transition edge sensors (TESs). Its current design features single SQUID-Array Amplifiers (SAA) at a temperature of about 400 mK in order to read out up to 64 TESs in a frequency division multiplexing scheme. The front-end part of the electronics (the SQUID Controller Assembly -SCA) was designed to handle this configuration. Nevertheless, alternative configurations of the experiment are being studied that might require a dual-stage SQUID (DSS) amplification chain in order to meet thermal and noise requirements. In light of this possibility, we have successfully investigated the feasibility of controlling two individual SAAs in a DSS Amplifier (DSSA) configuration with two independent channels of the present SCA. The SQUID directly connected to the sensor, commonly referred to as ‘front-end’, behaves as an emitter-follower, or buffer, circuit and it decouples the impedance of the TES(s) from the rest of the readout chain whilst producing a moderate amplification. The second SQUID, ‘booster’, is responsible for a high-gain amplification of the signal and can be thermally decoupled from the front-end allowing it to dissipate a lot more power and thus exhibiting a higher gain. We characterised a breadboard model in which two SQUID amplifiers are cascaded but hosted on the same circuit board and thus not thermally decoupled. This was intended to perform functional tests and to assess the feasibility of controlling a DSSA without introducing major changes in the already developed LiteBIRD SCA. We present the typical I-V and I-$\Phi$ curves of the two SQUIDs along with the characterisation of the DSSA in terms of bandwidth, linearity and total harmonic distortion (THD).
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-6
Compatibility Study of the LiteBIRD SQUID Controller Unit With a Dual-Stage SQUID Amplification Chain
The LiteBIRD satellite will map the polarisation of the Cosmic Microwave Background (CMB) with unprecedented sensitivity by means of antenna-coupled transition edge sensors (TESs). Its current design features single SQUID-Array Amplifiers (SAA) at a temperature of about 400 mK in order to read out up to 64 TESs in a frequency division multiplexing scheme. The front-end part of the electronics (the SQUID Controller Assembly -SCA) was designed to handle this configuration. Nevertheless, alternative configurations of the experiment are being studied that might require a dual-stage SQUID (DSS) amplification chain in order to meet thermal and noise requirements. In light of this possibility, we have successfully investigated the feasibility of controlling two individual SAAs in a DSS Amplifier (DSSA) configuration with two independent channels of the present SCA. The SQUID directly connected to the sensor, commonly referred to as ‘front-end’, behaves as an emitter-follower, or buffer, circuit and it decouples the impedance of the TES(s) from the rest of the readout chain whilst producing a moderate amplification. The second SQUID, ‘booster’, is responsible for a high-gain amplification of the signal and can be thermally decoupled from the front-end allowing it to dissipate a lot more power and thus exhibiting a higher gain. We characterised a breadboard model in which two SQUID amplifiers are cascaded but hosted on the same circuit board and thus not thermally decoupled. This was intended to perform functional tests and to assess the feasibility of controlling a DSSA without introducing major changes in the already developed LiteBIRD SCA. We present the typical I-V and I-$\Phi$ curves of the two SQUIDs along with the characterisation of the DSSA in terms of bandwidth, linearity and total harmonic distortion (THD).
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , C05026
The RFSoC-based electronics readout system for the BULLKID-DM experiment: sub-GeV dark matter detection with MKIDs
We present the readout and data acquisition (DAQ) system for BULLKID-DM, a cryogenic dark-matter experiment employing Kinetic Inductance Detectors (KIDs) to probe below 1 GeV dark matter candidates. The system is built around an AMD RFSoC (ZCU216) platform that synthesizes densely spaced probe tones, performs frequency demultiplexing and amplitude demodulation, and executes real-time triggering and background suppression across up to 16 readout lines with 145 resonators per line in the 700 MHz to 950 MHz band. A fully automated calibration flow integrates vector-network-analyzer (VNA) functionality, resonator-circle acquisition with in-firmware phase rotation for maximum trigger sensitivity, and an energy calibration scheme based on LED illumination via a mezzanine board on the FMC+ connector. We summarize architecture, firmware, preliminary phase-noise studies, and the status of the detector demonstrator. The system is ready for scale-up to the full BULLKID-DM detector at the Laboratori Nazionali del Gran Sasso (LNGS).
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , C05026
Open AccessThe RFSoC-based electronics readout system for the BULLKID-DM experiment: sub-GeV dark matter detection with MKIDs
We present the readout and data acquisition (DAQ) system for BULLKID-DM, a cryogenic dark-matter experiment employing Kinetic Inductance Detectors (KIDs) to probe below 1 GeV dark matter candidates. The system is built around an AMD RFSoC (ZCU216) platform that synthesizes densely spaced probe tones, performs frequency demultiplexing and amplitude demodulation, and executes real-time triggering and background suppression across up to 16 readout lines with 145 resonators per line in the 700 MHz to 950 MHz band. A fully automated calibration flow integrates vector-network-analyzer (VNA) functionality, resonator-circle acquisition with in-firmware phase rotation for maximum trigger sensitivity, and an energy calibration scheme based on LED illumination via a mezzanine board on the FMC+ connector. We summarize architecture, firmware, preliminary phase-noise studies, and the status of the detector demonstrator. The system is ready for scale-up to the full BULLKID-DM detector at the Laboratori Nazionali del Gran Sasso (LNGS).
- Open Access
- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Energy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Open AccessEnergy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search. - Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-9
An Overview of Potential Medical Applications of Microwave Kinetic Inductance Detectors
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-9
Open AccessAn Overview of Potential Medical Applications of Microwave Kinetic Inductance Detectors
- 11 July 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (8) , 1-8
Measurement of optical absorption in granular aluminum thin films at room temperature
- 11 July 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (8) , 1-8
Measurement of optical absorption in granular aluminum thin films at room temperature
- Open Access
- 31 October 2024
- Published by MDPI AG in Instruments
- Vol. 8 (4) , 47
Transition Edge Sensors: Physics and Applications
Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs exhibit unmatched energy resolution while being easily frequency domain multiplexed in arrays of several hundred pixels. Such great performance, along with rather simple and sturdy readout and amplification chains make TESs extremely compelling for applications in many fields of scientific endeavour. While the first part of this article is an in-depth discussion on the working principles of Transition Edge Sensors, the remainder of this review article focuses on the applications of Transition Edge Sensors in advanced scientific instrumentation serving as an accessible and thorough list of possible starting points for more comprehensive literature research.
- 31 October 2024
- Published by MDPI AG in Instruments
- Vol. 8 (4) , 47
Open AccessTransition Edge Sensors: Physics and Applications
Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs exhibit unmatched energy resolution while being easily frequency domain multiplexed in arrays of several hundred pixels. Such great performance, along with rather simple and sturdy readout and amplification chains make TESs extremely compelling for applications in many fields of scientific endeavour. While the first part of this article is an in-depth discussion on the working principles of Transition Edge Sensors, the remainder of this review article focuses on the applications of Transition Edge Sensors in advanced scientific instrumentation serving as an accessible and thorough list of possible starting points for more comprehensive literature research.
- Open Access
- 1 July 2024
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2024 (07)
Dark matter line searches with the Cherenkov Telescope Array
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g. box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.
- 1 July 2024
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2024 (07)
Open AccessDark matter line searches with the Cherenkov Telescope Array
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g. box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.
- Open Access
Limitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
Open AccessLimitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.