DHDaisuke Hamada

Daisuke Hamada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daisuke Hamada has a total of 103 co-authors. Here are the top co-authors by number of shared publications:

  • Koichi Sairyo

    Department of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan

    13 shared publications
  • Koichi Sairyo

    Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School

    12 shared publications
  • Tomohiro Goto

    Department of Orthopedics, Tokushima Municipal Hospital, Tokushima City, Tokushima, Japan

    11 shared publications
  • Keizo Wada

    Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan

    10 shared publications
  • Tomohiro Goto

    Tokushima University Department of Orthopedics, Institute of Biomedical Sciences Tokushima 770-8503 , Japan

    9 shared publications
  • Keizo Wada

    Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima City, Japan

    8 shared publications

Latest Publications

  • Open Access

    Flexion‐dependent differences in tibial rotation measured by navigation and robotic systems during bicruciate‐stabilised total knee arthroplasty

    by Keizo Wada, Daisuke Hamada, Yasuaki Tamaki, Shota Shigekiyo, Yuto Sugimine, Koichi Sairyo

    Purpose: This study compared the intraoperative tibial rotational kinematics between navigation‐assisted and robotic‐assisted bicruciate‐stabilised total knee arthroplasty (BCS‐TKA). Although both systems can evaluate knee motion intraoperatively, it is unclear whether they provide comparable rotational measurements. We hypothesised that these systems would show different tibial rotation profiles, particularly in deep knee flexion. Methods: This retrospective cohort study included 238 knees that underwent BCS‐TKA using an image‐free navigation system (Precision N) or an image‐free handheld robotic‐assisted system (NAVIO or CORI). Tibial rotation relative to the femur was measured intraoperatively through 0° to 120° of knee flexion. Patient‐reported outcomes were assessed using the 2011 Knee Society Score (KSS). Discrepancies in rotational display between the systems were evaluated by a preliminary bench test using a synthetic bone model. Groups were compared using the Kruskal–Wallis test followed by Dunn's post hoc test with Bonferroni correction. Results: Across all groups, BCS‐TKA demonstrated a characteristic pattern of internal rotation in early flexion, slight external rotation in mid‐flexion and progressive internal rotation towards deep flexion. At 120° of flexion, tibial internal rotation differed significantly among the three groups ( p < 0.05), with the navigation system displaying greater internal rotation than the robotic system, particularly NAVIO ( p < 0.01). The robotic system displayed a progressively more externally rotated tibial position beyond 40° of flexion in the bench test. The subjective domains of the KSS improved significantly in all groups at 1 year. Although statistically significant between‐group differences were observed in some domains, these differences were inconsistent, and their clinical relevance remains unclear. Conclusions: The robotic platform consistently indicated a more externally rotated tibial position compared to the navigation system, suggesting that the two systems apply different reference orientations for tibial rotation in deep knee flexion during BCS‐TKA. Therefore, caution is warranted when comparing intraoperative kinematic data across measurement platforms. Level of Evidence: Level III, retrospective cohort study.

  • Robotic Arm-Assisted Total Knee Arthroplasty for Osteoarthritis Associated with Osteopetrosis

    by Gakuto Yoshida, Yasuyuki Omichi, Tomohiro Goto, Daisuke Hamada, Koichi Sairyo, Shunji Nakano

    Case: A 74-year-old woman with osteopetrosis presented with severe right knee pain and difficulty walking due to osteoarthritis. She underwent robotic arm-assisted total knee arthroplasty (RA-TKA). Although the saw blade did not require replacement during surgery, a fracture associated with the tibial checkpoint occurred. The error of implant placement from the intraoperative plan was within 3.4°. After 1 year, the Forgotten Joint Score was 77, and she was independent in activities of daily living. Conclusion: RA-TKA allows safe and precise bone resection, achieving appropriate alignment even in osteopetrosis. Surgeons should be aware of fractures associated with checkpoints.

  • Comparison of methods for evaluating soft tissue balance in robotic-assisted total knee arthroplasty: A cadaveric study

    by Yasuaki Tamaki, Daisuke Hamada, Keizo Wada, Shota Shigekiyo, Yuto Sugimine, Yutaka Kinoshita, Koichi Tomita, Koichi Sairyo


  • Robotic Assisted TKA

    by Daisuke Hamada

  • Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study

    by Yasuyuki Omichi, Daisuke Hamada, Keizo Wada, Yasuaki Tamaki, Shota Shigekiyo, Koichi Sairyo

    The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. This retrospective case–control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior–posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip–knee–ankle angle between the two groups. The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip–knee–ankle angle between the two groups. Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in better clinical outcomes.


  • Open Access

    Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study

    by Yasuyuki Omichi, Daisuke Hamada, Keizo Wada, Yasuaki Tamaki, Shota Shigekiyo, Koichi Sairyo

    Background The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. Methods This retrospective case-control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior–posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip-knee-ankle angle between the two groups. Results The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip-knee-ankle angle between the two groups. Conclusion Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in a better clinical outcome.

  • Open Access

    Hematogenous prosthetic knee joint infection with Klebsiella pneumoniae caused by asymptomatic gallbladder abscess: a case report and literature review

    by Yasuyuki Omichi, Daisuke Hamada, Ryo Okada, Keizo Wada, Yasuaki Tamaki, Shinichiro Yamada, Tomohiro Goto, Koichi Sairyo

    Klebsiella pneumoniae has the ability to form biofilm; therefore, the treatment of prosthetic joint infection involving K. pneumoniae is often challenging. This report describes the first case of acute hematogenous prosthetic knee joint infection with K. pneumoniae that occurred as a result of an asymptomatic gallbladder abscess. The patient was a 78-year-old man who underwent bilateral total knee arthroplasty 6 years ago. He had pain and swelling in his right knee. The synovial fluid culture of the right knee revealed K. pneumoniae and prosthetic joint infection was diagnosed. Computed tomography revealed a gallbladder abscess in the absence of right upper abdominal pain. The patient underwent simultaneous debridement of the knee and open cholecystectomy. The treatment was successful and the prosthesis was retained. In cases of hematogenous prosthetic joint infection with K. pneumoniae, other sources of infection should be suspected and investigated regardless of whether they are symptomatic.


  • Kinematic comparison between the knee after bicruciate stabilized total knee arthroplasty and the native knee: A cadaveric study

    by Yasuaki Tamaki, Daisuke Hamada, Keizo Wada, Tomoya Takasago, Akihiro Nitta, Yasuyuki Omichi, Tomohiro Goto, Yoshihiro Tsuruo, Koichi Sairyo


  • Contributions of the ischiofemoral ligament, iliofemoral ligament, and conjoined tendon to hip stability after total hip arthroplasty: A cadaveric study

    by Yasuaki Tamaki, Tomohiro Goto, Joji Iwase, Keizo Wada, Daisuke Hamada, Yoshihiro Tsuruo, Koichi Sairyo

    An adequate soft tissue balance is important in total hip arthroplasty (THA). This study assessed the contribution of the iliofemoral ligament, ischiofemoral ligament, and conjoined tendon to the range of hip rotation after THA and hip stability in response to axial traction. THA was performed in eight fresh‐frozen cadaveric specimens via an anterolateral approach using a navigation system. The ischiofemoral ligament, the medial arm of the iliofemoral ligament, and the conjoined tendon were resected in that order. The ranges of external and internal rotation and the amount of movement of the femoral head in response to axial traction were measured with the hip in 10° of extension, the neutral position, and in 10°, 30°, and 60° of flexion. Resection of the medial arm of the iliofemoral ligament significantly increased the range of external rotation in 10° of extension, the neutral position, and in 10°, 30°, and 60° of flexion. The conjoined tendon was the most important inhibitor of internal rotation from 10° of extension to 30° of flexion. Although each single element had a minor role in stabilizing the hip when axial traction was applied, resection of two or more elements significantly affected joint stability. The iliofemoral ligament and conjoined tendon are the main inhibitors of external rotation and internal rotation, respectively, when THA is performed using an anterior or anterolateral approach. Resection of two or more elements could greatly affect hip stability when axial traction is applied.


  • Open Access

    A Rare Case of Extremely Severe Heterotopic Ossification after Primary Total Hip Arthroplasty due to Persistent Mild Periprosthetic Joint Infection

    by Yutaka Kinoshita, Shunji Nakano, Shinji Yoshioka, Masaru Nakamura, Tomohiro Goto, Daisuke Hamada, Koichi Sairyo

    Periprosthetic joint infection (PJI) caused by coagulase-negative staphylococci (CNS) can be a mild, persisting infection. Although heterotopic ossification (HO) is common following total hip arthroplasty (THA), the etiology of severe HO remains unclear. Herein, we describe a rare case of extremely severe HO after a PJI associated with a Staphylococcus caprae infection in a 78-year-old male patient. The patient had poorly controlled diabetes mellitus with no diabetic complications. The patient had no previous history of hip surgery, hip injury, or systemic bacterial infection. Immediately after the initial THA, he developed intermittent low-grade fever (37C), which persisted for 3 months; consequently, he also reported mild hip pain during walking. He experienced a gradual decrease in hip range of motion within 5 years after the surgery, with progressive gait impairment. Two revision surgeries were required for the successful treatment of this difficult case. The patients hip function improved, and the PJI was controlled following the second revision surgery. Based on the clinical course, CNS-caused PJI may lead to severe HO. This possibility warrants verification from an accumulated number of cases.