Keizo Wada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Keizo Wada has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Koichi Sairyo
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School
17 shared publications Koichi Sairyo
Department of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan
12 shared publications- Tomohiro Goto
Department of Orthopedics, Tokushima Municipal Hospital, Tokushima City, Tokushima, Japan
12 shared publications Daisuke Hamada
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
10 shared publications- Daisuke Hamada
Department of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan
10 shared publications - Yasuaki Tamaki
Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
9 shared publications
Latest Publications
- Open Access
- 4 June 2026
- Published by Elsevier in Journal of Joint Surgery and Research
- Vol. 4 (3) , 193-202
Clinical outcomes of bipolar hemiarthroplasty for femoral neck fracture: a nationwide, multicenter, prospective observational study
- 4 June 2026
- Published by Elsevier in Journal of Joint Surgery and Research
- Vol. 4 (3) , 193-202
Open AccessClinical outcomes of bipolar hemiarthroplasty for femoral neck fracture: a nationwide, multicenter, prospective observational study
- 30 May 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (8) , 1-7
Preoperative factors associated with long-distance walking ability one year after total hip arthroplasty: a prospective cohort study
Purpose This study aimed to identify preoperative predictors of the six-minute walk distance (6MWD) one year after primary unilateral total hip arthroplasty (THA). Methods This prospective cohort study included 152 women with hip osteoarthritis who underwent primary unilateral THA between April 2016 and June 2024. Preoperative assessments included age, body mass index (BMI), pain intensity (numerical rating scale), Timed Up and Go (TUG) test, 6MWD, hip abductor strength, range of motion (ROM) in flexion and extension at the hip, presence of contralateral hip osteoarthritis, and gait pattern (independent/cane-assisted). The primary outcome was 6MWD at one year postoperatively. Univariate and multiple linear regression analyses were performed to identify independent preoperative predictors of the 6MWD at one year postoperatively. Results All functional outcomes except BMI improved significantly at one year postoperatively. Multiple regression analysis identified age (β = − 2.8, p = 0.001), BMI (β = − 3.3, p = 0.049), preoperative 6MWD (β = 0.6, p = 0.001), and contralateral hip extension ROM (β = 2.8, p = 0.045) as independent predictors of 6MWD at one year postoperatively. Conclusions The 6MWD significantly improved one year after THA but not to the level observed in healthy individuals. Long-distance walking ability one year after THA is associated not only with systemic factors such as age, BMI, and preoperative endurance but also with contralateral hip extension ROM. The functional status of both lower limbs and global physical capacity should be considered when evaluating postoperative walking recovery.
- 30 May 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (8) , 1-7
Preoperative factors associated with long-distance walking ability one year after total hip arthroplasty: a prospective cohort study
Purpose This study aimed to identify preoperative predictors of the six-minute walk distance (6MWD) one year after primary unilateral total hip arthroplasty (THA). Methods This prospective cohort study included 152 women with hip osteoarthritis who underwent primary unilateral THA between April 2016 and June 2024. Preoperative assessments included age, body mass index (BMI), pain intensity (numerical rating scale), Timed Up and Go (TUG) test, 6MWD, hip abductor strength, range of motion (ROM) in flexion and extension at the hip, presence of contralateral hip osteoarthritis, and gait pattern (independent/cane-assisted). The primary outcome was 6MWD at one year postoperatively. Univariate and multiple linear regression analyses were performed to identify independent preoperative predictors of the 6MWD at one year postoperatively. Results All functional outcomes except BMI improved significantly at one year postoperatively. Multiple regression analysis identified age (β = − 2.8, p = 0.001), BMI (β = − 3.3, p = 0.049), preoperative 6MWD (β = 0.6, p = 0.001), and contralateral hip extension ROM (β = 2.8, p = 0.045) as independent predictors of 6MWD at one year postoperatively. Conclusions The 6MWD significantly improved one year after THA but not to the level observed in healthy individuals. Long-distance walking ability one year after THA is associated not only with systemic factors such as age, BMI, and preoperative endurance but also with contralateral hip extension ROM. The functional status of both lower limbs and global physical capacity should be considered when evaluating postoperative walking recovery.
- Open Access
- 1 April 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (2)
Flexion‐dependent differences in tibial rotation measured by navigation and robotic systems during bicruciate‐stabilised total knee arthroplasty
Purpose: This study compared the intraoperative tibial rotational kinematics between navigation‐assisted and robotic‐assisted bicruciate‐stabilised total knee arthroplasty (BCS‐TKA). Although both systems can evaluate knee motion intraoperatively, it is unclear whether they provide comparable rotational measurements. We hypothesised that these systems would show different tibial rotation profiles, particularly in deep knee flexion. Methods: This retrospective cohort study included 238 knees that underwent BCS‐TKA using an image‐free navigation system (Precision N) or an image‐free handheld robotic‐assisted system (NAVIO or CORI). Tibial rotation relative to the femur was measured intraoperatively through 0° to 120° of knee flexion. Patient‐reported outcomes were assessed using the 2011 Knee Society Score (KSS). Discrepancies in rotational display between the systems were evaluated by a preliminary bench test using a synthetic bone model. Groups were compared using the Kruskal–Wallis test followed by Dunn's post hoc test with Bonferroni correction. Results: Across all groups, BCS‐TKA demonstrated a characteristic pattern of internal rotation in early flexion, slight external rotation in mid‐flexion and progressive internal rotation towards deep flexion. At 120° of flexion, tibial internal rotation differed significantly among the three groups ( p < 0.05), with the navigation system displaying greater internal rotation than the robotic system, particularly NAVIO ( p < 0.01). The robotic system displayed a progressively more externally rotated tibial position beyond 40° of flexion in the bench test. The subjective domains of the KSS improved significantly in all groups at 1 year. Although statistically significant between‐group differences were observed in some domains, these differences were inconsistent, and their clinical relevance remains unclear. Conclusions: The robotic platform consistently indicated a more externally rotated tibial position compared to the navigation system, suggesting that the two systems apply different reference orientations for tibial rotation in deep knee flexion during BCS‐TKA. Therefore, caution is warranted when comparing intraoperative kinematic data across measurement platforms. Level of Evidence: Level III, retrospective cohort study.
- 1 April 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (2)
Open AccessFlexion‐dependent differences in tibial rotation measured by navigation and robotic systems during bicruciate‐stabilised total knee arthroplasty
Purpose: This study compared the intraoperative tibial rotational kinematics between navigation‐assisted and robotic‐assisted bicruciate‐stabilised total knee arthroplasty (BCS‐TKA). Although both systems can evaluate knee motion intraoperatively, it is unclear whether they provide comparable rotational measurements. We hypothesised that these systems would show different tibial rotation profiles, particularly in deep knee flexion. Methods: This retrospective cohort study included 238 knees that underwent BCS‐TKA using an image‐free navigation system (Precision N) or an image‐free handheld robotic‐assisted system (NAVIO or CORI). Tibial rotation relative to the femur was measured intraoperatively through 0° to 120° of knee flexion. Patient‐reported outcomes were assessed using the 2011 Knee Society Score (KSS). Discrepancies in rotational display between the systems were evaluated by a preliminary bench test using a synthetic bone model. Groups were compared using the Kruskal–Wallis test followed by Dunn's post hoc test with Bonferroni correction. Results: Across all groups, BCS‐TKA demonstrated a characteristic pattern of internal rotation in early flexion, slight external rotation in mid‐flexion and progressive internal rotation towards deep flexion. At 120° of flexion, tibial internal rotation differed significantly among the three groups ( p < 0.05), with the navigation system displaying greater internal rotation than the robotic system, particularly NAVIO ( p < 0.01). The robotic system displayed a progressively more externally rotated tibial position beyond 40° of flexion in the bench test. The subjective domains of the KSS improved significantly in all groups at 1 year. Although statistically significant between‐group differences were observed in some domains, these differences were inconsistent, and their clinical relevance remains unclear. Conclusions: The robotic platform consistently indicated a more externally rotated tibial position compared to the navigation system, suggesting that the two systems apply different reference orientations for tibial rotation in deep knee flexion during BCS‐TKA. Therefore, caution is warranted when comparing intraoperative kinematic data across measurement platforms. Level of Evidence: Level III, retrospective cohort study.
- 20 February 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 75, 279-284
Cutoff values of knee extensor strength for stair ascent and descent after bicruciate-stabilized total knee arthroplasty
- 20 February 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 75, 279-284
Cutoff values of knee extensor strength for stair ascent and descent after bicruciate-stabilized total knee arthroplasty
- 10 December 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (1) , 121-126
Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode
Purpose This study evaluated the accuracy of intraoperative leg length and femoral anteversion measurements obtained during total hip arthroplasty (THA) using the Mako robotic system with enhanced mode. Methods A total of 55 hips in four men and 51 women who underwent primary THA with the Mako system via an anterolateral approach were retrospectively evaluated. Intraoperative measurements of leg length and femoral anteversion displayed by the Mako enhanced mode were compared with postoperative CT-based measurements. Absolute errors and their distributions were calculated to assess the accuracy of intraoperative assessments. Results The mean absolute error was 2.3 ± 1.8 mm for postoperative leg length discrepancy and 2.9 ± 2.2° for stem anteversion. Of the 55 hips, 46 (83.6%) showed leg length errors within 3 mm and 51 (92.7%) within 5 mm. For stem anteversion, 48 hips (87.3%) were within 3° and all 55 hips (100%) were within 5°. Mako enhanced mode could not be completed in 10.7% of cases because of femoral array loosening or screw penetration into the medullary canal. Conclusion Mako enhanced mode demonstrated clinically acceptable accuracy for intraoperative measurement of leg length and femoral anteversion, contributing to precise femoral stem implantation in robotic-assisted THA.
- 10 December 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (1) , 121-126
Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode
Purpose This study evaluated the accuracy of intraoperative leg length and femoral anteversion measurements obtained during total hip arthroplasty (THA) using the Mako robotic system with enhanced mode. Methods A total of 55 hips in four men and 51 women who underwent primary THA with the Mako system via an anterolateral approach were retrospectively evaluated. Intraoperative measurements of leg length and femoral anteversion displayed by the Mako enhanced mode were compared with postoperative CT-based measurements. Absolute errors and their distributions were calculated to assess the accuracy of intraoperative assessments. Results The mean absolute error was 2.3 ± 1.8 mm for postoperative leg length discrepancy and 2.9 ± 2.2° for stem anteversion. Of the 55 hips, 46 (83.6%) showed leg length errors within 3 mm and 51 (92.7%) within 5 mm. For stem anteversion, 48 hips (87.3%) were within 3° and all 55 hips (100%) were within 5°. Mako enhanced mode could not be completed in 10.7% of cases because of femoral array loosening or screw penetration into the medullary canal. Conclusion Mako enhanced mode demonstrated clinically acceptable accuracy for intraoperative measurement of leg length and femoral anteversion, contributing to precise femoral stem implantation in robotic-assisted THA.
- Open Access
- 9 May 2025
- Published by Elsevier in Journal of Joint Surgery and Research
- Vol. 3 (2) , 90-95
Robotic-assisted total knee arthroplasty: Systematic review of surgical assist robotic systems available in Japan
- 9 May 2025
- Published by Elsevier in Journal of Joint Surgery and Research
- Vol. 3 (2) , 90-95
Open AccessRobotic-assisted total knee arthroplasty: Systematic review of surgical assist robotic systems available in Japan
- 3 December 2024
- Published by Springer Nature
- p. 103-107
Kinematics After TKA -BCR
- Open Access
- 21 March 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (3) , 398-405
Relation between spine alignment and scapular position by plain radiograph examination
- 21 March 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (3) , 398-405
Open AccessRelation between spine alignment and scapular position by plain radiograph examination
- 27 September 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (6) , 2831-2839
Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. This retrospective case–control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior–posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip–knee–ankle angle between the two groups. The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip–knee–ankle angle between the two groups. Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in better clinical outcomes.
- 27 September 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (6) , 2831-2839
Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. This retrospective case–control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior–posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip–knee–ankle angle between the two groups. The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip–knee–ankle angle between the two groups. Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in better clinical outcomes.