Mohamed Bencheikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mohamed Bencheikh has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Abdelmajid Maghnouj
Department of Physics, Faculty of Sciences Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, 30000, Fès, Morocco
25 shared publicationsJaouad Tajmouati
Department of Physics, Faculty of Sciences Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, 30000, Fès, Morocco
25 shared publications- Abdessamad Didi
Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences, Hassan First University, Settat, Morocco
17 shared publications Ahmed Dadouch
LISTA, Faculty of Science Dhar El Mahraz Fez, Morocco
10 shared publications- Otman Jaï
Laboratory of Technologies and Industrial Services, Higher School of Technology, Sidi Mohamed Ben Abdellah University, Fez, Morocco
6 shared publications - Abdesslam Lamrabet
University Sidi Mohamed Ben Abdellah
5 shared publications
Latest Publications
- Open Access
- 1 October 2021
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 53 (10) , 3164-3170
GEANT4 characterization of the neutronic behavior of the active zone of the MEGAPIE spallation target
- 1 October 2021
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 53 (10) , 3164-3170
Open AccessGEANT4 characterization of the neutronic behavior of the active zone of the MEGAPIE spallation target
- Open Access
- 1 June 2021
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 27 (2) , 151-156
Detailed Monte Carlo analysis of the secondary photons coming out of the therapeutic X-ray beam of linear accelerator
External photon beam radiotherapy is often used in tumor treatment. The photons are generated from the target which had stricken by the primary electron beam (incident particles). The photon beam contains the primary photons coming directly from the target and secondary photons coming from the photon interactions with head component materials (scattered photons). Altogether is thereafter used in radiotherapy treatment. This Monte Carlo study aims to investigate and evaluate the secondary radiations (photons) in terms of fluence, energy fluence, spectral distribution, mean energy and angular spread distribution. The secondary photons, which contributed in radiotherapy treatment, are examined and evaluated in number (fluence) and energy. At the phantom surface, the secondary photons originated in the whole linac head are mainly coming from the primary collimator. In 0.45% of secondary photons coming from the whole linac head, the primary collimator contributes by 86% and they are more energetic. However, the flattening filter and the secondary collimator contribute together by less than 14% and their photons are less energetic and then can deteriorate the beam dosimetry quality. To improve the radiotherapy treatment quality, the number of photons of low energy should be as low as possible in the clinical beam. Our work can be a basic investigation to use in the improvement of linac head configuration and specially the beam modifiers.
- 1 June 2021
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 27 (2) , 151-156
Open AccessDetailed Monte Carlo analysis of the secondary photons coming out of the therapeutic X-ray beam of linear accelerator
External photon beam radiotherapy is often used in tumor treatment. The photons are generated from the target which had stricken by the primary electron beam (incident particles). The photon beam contains the primary photons coming directly from the target and secondary photons coming from the photon interactions with head component materials (scattered photons). Altogether is thereafter used in radiotherapy treatment. This Monte Carlo study aims to investigate and evaluate the secondary radiations (photons) in terms of fluence, energy fluence, spectral distribution, mean energy and angular spread distribution. The secondary photons, which contributed in radiotherapy treatment, are examined and evaluated in number (fluence) and energy. At the phantom surface, the secondary photons originated in the whole linac head are mainly coming from the primary collimator. In 0.45% of secondary photons coming from the whole linac head, the primary collimator contributes by 86% and they are more energetic. However, the flattening filter and the secondary collimator contribute together by less than 14% and their photons are less energetic and then can deteriorate the beam dosimetry quality. To improve the radiotherapy treatment quality, the number of photons of low energy should be as low as possible in the clinical beam. Our work can be a basic investigation to use in the improvement of linac head configuration and specially the beam modifiers.
- 1 July 2020
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 25 (4) , 484-488
Dosimetry quality control based on percent depth dose rate variation for checking beam quality in radiotherapy
Recently, the quality management inside a radiotherapy department has been crucial to treat cancer efficiently. Thus, many international bodies recommend multiple methods to check in periodically the dosimetry quality beyond the depth of 10 cm as the beam quality index. However, they evade checking out the beam dosimetry quality on both the build-up dose and the electronic equilibrium regions. The objective of this study is to cover the overall variation of the percent depth dose (PDD) by including all sub-regions in the procedure evaluation of the beam quality. In this work, we have studied and examined the dosimetry quality by considering the whole PDD variation. The PDD rate is therefore introduced to determine accurately the quality as an overall notion in external beam radiotherapy according to the field size and photon beam energy. We have presented the reasons and methods to introduce particles contamination, such as electrons and low photon energy in this new approach. The latter enables us to figure the dosimetry quality by extending the International Atomic Energy Agency (IAEA) procedure at any field size less than 25 x 25 cm(2) under the current conditions without being limited to 10 x 10 cm(2) on the exponential decay region. (C) 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
- 1 July 2020
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 25 (4) , 484-488
Dosimetry quality control based on percent depth dose rate variation for checking beam quality in radiotherapy
Recently, the quality management inside a radiotherapy department has been crucial to treat cancer efficiently. Thus, many international bodies recommend multiple methods to check in periodically the dosimetry quality beyond the depth of 10 cm as the beam quality index. However, they evade checking out the beam dosimetry quality on both the build-up dose and the electronic equilibrium regions. The objective of this study is to cover the overall variation of the percent depth dose (PDD) by including all sub-regions in the procedure evaluation of the beam quality. In this work, we have studied and examined the dosimetry quality by considering the whole PDD variation. The PDD rate is therefore introduced to determine accurately the quality as an overall notion in external beam radiotherapy according to the field size and photon beam energy. We have presented the reasons and methods to introduce particles contamination, such as electrons and low photon energy in this new approach. The latter enables us to figure the dosimetry quality by extending the International Atomic Energy Agency (IAEA) procedure at any field size less than 25 x 25 cm(2) under the current conditions without being limited to 10 x 10 cm(2) on the exponential decay region. (C) 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
- Open Access
- 28 February 2020
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 32 (3) , 2163-2169
New study of spallation reactions (Be + p) and (Sn + p) at 1.2 GeV per nucleon
The aim of this study is to calculate neutron multiplicity per incident proton in the collision of 1.2 GeV energetic proton beams with Beryllium and Tin. These targets had been estimated using INCL4/ABLA physics models. The results of our Monte Carlo optimization study using MCNP.6 code gives several findings: the neutrons levels produced by Beryllium (Be) and Tin (Sn) respectively are 2.7 n/p and 13 n/p; the neutron current scatter varies by the incident angles of the proton beam and the variation of the neutron intensity in the targets. This paper summarizes principles of the method that determine the spectrum of high-energy neutrons, which improve with precision neutron flux, current, and calculation yield.
- 28 February 2020
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 32 (3) , 2163-2169
Open AccessNew study of spallation reactions (Be + p) and (Sn + p) at 1.2 GeV per nucleon
The aim of this study is to calculate neutron multiplicity per incident proton in the collision of 1.2 GeV energetic proton beams with Beryllium and Tin. These targets had been estimated using INCL4/ABLA physics models. The results of our Monte Carlo optimization study using MCNP.6 code gives several findings: the neutrons levels produced by Beryllium (Be) and Tin (Sn) respectively are 2.7 n/p and 13 n/p; the neutron current scatter varies by the incident angles of the proton beam and the variation of the neutron intensity in the targets. This paper summarizes principles of the method that determine the spectrum of high-energy neutrons, which improve with precision neutron flux, current, and calculation yield.
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 21 (3) , 275-280
MONTE CARLO-BASED ANALYSIS OF THE PHOTON BEAM FLUENCE WITH AIR GAP THICKNESS BETWEEN LINAC HEAD EXIT WINDOW AND PATIENT'S SKIN IN RADIOTHERAPY TREATMENTS
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 21 (3) , 275-280
MONTE CARLO-BASED ANALYSIS OF THE PHOTON BEAM FLUENCE WITH AIR GAP THICKNESS BETWEEN LINAC HEAD EXIT WINDOW AND PATIENT'S SKIN IN RADIOTHERAPY TREATMENTS
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 21 (2) , 200-209
ANALYSIS AND EVALUATION OF SECONDARY PHOTONS ORIGINATED IN JAWS AS CONTAMINATION PARTICLES AT THE PHANTOM SURFACE
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 21 (2) , 200-209
ANALYSIS AND EVALUATION OF SECONDARY PHOTONS ORIGINATED IN JAWS AS CONTAMINATION PARTICLES AT THE PHANTOM SURFACE
- Open Access
- 26 September 2019
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 31 (4) , 1543-1546
Mathematical parameterization of dosimetry quality index checking of the photon beam based on IAEA TRS-398 protocol
The quality is essential for radiation use in medicine and the beam quality index is the basic parameter to periodically check the normal functioning of Linac head in radiotherapy treatment. It is recommended by IAEA protocols TRS-398 based on absorbed dose in water. The PDD method is used as a basis of the parameterization of the photon beam quality for predicting its variation with beam energy and field size. The objective of this work is to establish a mathematical law for predicting and checking the beam dosimetry quality index according to field size and beam energy based on IAEA TRS-398 protocol. For an easier and more reliable procedure determination of the beam quality based on TRS 398, two empirical laws were therefore established with an accuracy better than 2%. They can serve the basic floor to medical physicist to verify and to control the dosimetry output quality at arbitrary field size. Our findings aim to facilitate the dosimetry quality control that set in use according to current conditions for checking out the radiotherapy efficiency and the safety inside the treatment room.
- 26 September 2019
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 31 (4) , 1543-1546
Open AccessMathematical parameterization of dosimetry quality index checking of the photon beam based on IAEA TRS-398 protocol
The quality is essential for radiation use in medicine and the beam quality index is the basic parameter to periodically check the normal functioning of Linac head in radiotherapy treatment. It is recommended by IAEA protocols TRS-398 based on absorbed dose in water. The PDD method is used as a basis of the parameterization of the photon beam quality for predicting its variation with beam energy and field size. The objective of this work is to establish a mathematical law for predicting and checking the beam dosimetry quality index according to field size and beam energy based on IAEA TRS-398 protocol. For an easier and more reliable procedure determination of the beam quality based on TRS 398, two empirical laws were therefore established with an accuracy better than 2%. They can serve the basic floor to medical physicist to verify and to control the dosimetry output quality at arbitrary field size. Our findings aim to facilitate the dosimetry quality control that set in use according to current conditions for checking out the radiotherapy efficiency and the safety inside the treatment room.
- 9 April 2019
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 30 (5) , 75
Production threshold impact on a GEANT4 calculation of the power deposition in a fast domain: MEGAPIE spallation target
- 9 April 2019
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 30 (5) , 75
Production threshold impact on a GEANT4 calculation of the power deposition in a fast domain: MEGAPIE spallation target
- 12 March 2019
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 30 (4) , 54
Assessment of the power deposition on the MEGAPIE spallation target using the GEANT4 toolkit
- 12 March 2019
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 30 (4) , 54
Assessment of the power deposition on the MEGAPIE spallation target using the GEANT4 toolkit
- 8 March 2019
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 18 (2) , 190
Determination of geometrical margins in external beam radiotherapy for prostate cancer: RETRACTION
- 8 March 2019
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 18 (2) , 190
Determination of geometrical margins in external beam radiotherapy for prostate cancer: RETRACTION