Fahd Abou Nada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fahd Abou Nada has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mattias Richter
Division of Combustion Physics, Lund University, Sweden
7 shared publications C. Knappe
Division of Combustion Physics, Department of Physics, Lund University, Lund, Sweden
5 shared publicationsM. Aldén
Division of Combustion Physics, Department of Physics, Lund University, Lund, Sweden
3 shared publications- Marcus Aldén
Division of Combustion Physics, Lund University, P.O. Box 118, SE-221 00 Lund, Sweden
2 shared publications C Knappe
Department of Physics, Division of Combustion Physics, Lund University, Box 118, SE-22100, Lund, Sweden
1 shared publicationChristoph Knappe
Lund University, Lund, Sweden
1 shared publication
Latest Publications
- 1 June 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (6) , 1-12
Improved measurement precision in decay time-based phosphor thermometry
- 1 June 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (6) , 1-12
Improved measurement precision in decay time-based phosphor thermometry
- 19 October 2014
- Published by ASME International
A First Application of Thermographic Phosphors in a Marine Two-Stroke Diesel Engine for Surface Temperature Measurement
Phosphor thermometry is applied for the first time in a large-bore two-stroke diesel engine. The work proves the practicality of phosphor thermometry in large-bore engines. The experiments were conducted on the MAN 4T50ME-X marine research engine equipped with an optical cylinder head. By employing a thin surface coating of CdWO4 phosphor, cycle resolved temperature measurements of the cylinder wall were obtained. Motored and fired engine operations were tested at engine loads covering the low and medium engine load range. Phosphor thermometry proved to be successful in retrieving the temperature with standard deviations ranging around 1–8 K. Experimental considerations like detector linearity, coating thickness and an automated phosphor calibration routine will be addressed.
- 19 October 2014
- Published by ASME International
A First Application of Thermographic Phosphors in a Marine Two-Stroke Diesel Engine for Surface Temperature Measurement
Phosphor thermometry is applied for the first time in a large-bore two-stroke diesel engine. The work proves the practicality of phosphor thermometry in large-bore engines. The experiments were conducted on the MAN 4T50ME-X marine research engine equipped with an optical cylinder head. By employing a thin surface coating of CdWO4 phosphor, cycle resolved temperature measurements of the cylinder wall were obtained. Motored and fired engine operations were tested at engine loads covering the low and medium engine load range. Phosphor thermometry proved to be successful in retrieving the temperature with standard deviations ranging around 1–8 K. Experimental considerations like detector linearity, coating thickness and an automated phosphor calibration routine will be addressed.
- Open Access
- 20 January 2014
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 25 (2) , 025201
Development of an automatic routine for calibration of thermographic phosphors
- 20 January 2014
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 25 (2) , 025201
Open AccessDevelopment of an automatic routine for calibration of thermographic phosphors
- 1 January 2014
- Published by Institution of Engineering and Technology (IET)
On the automation of thermographic phosphor calibration
- 1 January 2014
- Published by Institution of Engineering and Technology (IET)
On the automation of thermographic phosphor calibration
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 879-884
Response regime studies on standard detectors for decay time determination in phosphor thermometry
This work compares the extent of linear response regimes from standard time-resolving optical detectors for phosphor thermometry. Different types of Photomultipliers (ordinary and time-gated) as well as an Avalanche Photodiode are tested and compared using the phosphorescent time decay of CdWO 4 that ranges from 10 μs down to a few ns within a temperature span of 290 to 580 K. Effects originating from incipient detector saturation, far from obvious to the operator's eye, are revealed as a change in evaluated phosphorescence decay time. Since the decay time of thermographic phosphors itself is used for temperature determination - systematic temperature errors up to several tens of Kelvins may be introduced by such detector saturation. A detector mapping procedure is suggested in order to identify linear response regions where the decay-to-temperature evaluation can be performed unbiased. Generation of such a library is highly recommended prior to any quantitative measurement attempt. Using this detector library, even signals collected in the partly saturated regime can be corrected to their unbiased value extending the usable detector operating range significantly. Further, the use of an external current-to-voltage amplifier proved useful for most applications in time-based phosphor thermometry helping to limit saturation effects whilst maintaining a reasonable bandwidth and signal outputs.
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 879-884
Response regime studies on standard detectors for decay time determination in phosphor thermometry
This work compares the extent of linear response regimes from standard time-resolving optical detectors for phosphor thermometry. Different types of Photomultipliers (ordinary and time-gated) as well as an Avalanche Photodiode are tested and compared using the phosphorescent time decay of CdWO 4 that ranges from 10 μs down to a few ns within a temperature span of 290 to 580 K. Effects originating from incipient detector saturation, far from obvious to the operator's eye, are revealed as a change in evaluated phosphorescence decay time. Since the decay time of thermographic phosphors itself is used for temperature determination - systematic temperature errors up to several tens of Kelvins may be introduced by such detector saturation. A detector mapping procedure is suggested in order to identify linear response regions where the decay-to-temperature evaluation can be performed unbiased. Generation of such a library is highly recommended prior to any quantitative measurement attempt. Using this detector library, even signals collected in the partly saturated regime can be corrected to their unbiased value extending the usable detector operating range significantly. Further, the use of an external current-to-voltage amplifier proved useful for most applications in time-based phosphor thermometry helping to limit saturation effects whilst maintaining a reasonable bandwidth and signal outputs.
- 1 September 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (9) , 094901
Comparison of photo detectors and operating conditions for decay time determination in phosphor thermometry
This work compares the extent of linear response regions from standard time-resolving optical detectors for phosphor thermometry. Different types of photomultipliers (ordinary and time-gated) as well as an avalanche photodiode were tested and compared using the phosphorescence decay time of cadmium tungstate (CdWO4). Effects originating from incipient detector saturation are revealed as a change in evaluated phosphorescence decay time, which was found to be a more sensitive measure for saturation than the conventional signal strength comparison between in- and output. Since the decay time of thermographic phosphors is used for temperature determination systematic temperature errors in the order of several tens of Kelvins may be introduced. Saturation from the initial intensity is isolated from temporally developed saturation by varying the CdWO4 decay time over the microsecond to nanosecond range, resultant of varying the temperature from 290 to 580 K. A detector mapping procedure is developed in order to identify linear response regions where the decay-to-temperature evaluations are unbiased. In addition, this mapping procedure generates a library of the degree of distortion for operating points outside of linear response regions. Signals collected in the partly saturated regime can thus be corrected to their unbiased value using this library, extending the usable detector operating range significantly.
- 1 September 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (9) , 094901
Comparison of photo detectors and operating conditions for decay time determination in phosphor thermometry
This work compares the extent of linear response regions from standard time-resolving optical detectors for phosphor thermometry. Different types of photomultipliers (ordinary and time-gated) as well as an avalanche photodiode were tested and compared using the phosphorescence decay time of cadmium tungstate (CdWO4). Effects originating from incipient detector saturation are revealed as a change in evaluated phosphorescence decay time, which was found to be a more sensitive measure for saturation than the conventional signal strength comparison between in- and output. Since the decay time of thermographic phosphors is used for temperature determination systematic temperature errors in the order of several tens of Kelvins may be introduced. Saturation from the initial intensity is isolated from temporally developed saturation by varying the CdWO4 decay time over the microsecond to nanosecond range, resultant of varying the temperature from 290 to 580 K. A detector mapping procedure is developed in order to identify linear response regions where the decay-to-temperature evaluations are unbiased. In addition, this mapping procedure generates a library of the degree of distortion for operating points outside of linear response regions. Signals collected in the partly saturated regime can thus be corrected to their unbiased value using this library, extending the usable detector operating range significantly.
- 1 March 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (3) , 034901
Investigation and compensation of the nonlinear response in photomultiplier tubes for quantitative single-shot measurements
A concept for time-sensitive optical detectors is described that shows how to confirm whether the detection device is operating in the linear response regime. By evaluating the recorded time decay of a thermographic phosphor, even weak saturation effects far from obvious situations can be identified and further related to either optical or electrical saturation. The concept has been validated by running a PMT detector close to saturation and exposing it to the optical signal decay of two different thermographic phosphors, La2O2S:Eu and CdWO4. It was confirmed that short but intense light exposures at the beginning of an individual time decay influence the detector response for the rest of the decaying signal including temporal areas, where the anode current has dropped well below the manufacturer specified current limit. Such situations are common when applying, e.g., phosphor thermometry where it is necessary to retrieve the full decay curve from a single-shot event, i.e., standard techniques based on single-photon counting are omitted. Finally, means of compensation are introduced in order to facilitate the retrieval of useful information from the measurement data when operation in the non-linear response regime is inevitable.
- 1 March 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (3) , 034901
Investigation and compensation of the nonlinear response in photomultiplier tubes for quantitative single-shot measurements
A concept for time-sensitive optical detectors is described that shows how to confirm whether the detection device is operating in the linear response regime. By evaluating the recorded time decay of a thermographic phosphor, even weak saturation effects far from obvious situations can be identified and further related to either optical or electrical saturation. The concept has been validated by running a PMT detector close to saturation and exposing it to the optical signal decay of two different thermographic phosphors, La2O2S:Eu and CdWO4. It was confirmed that short but intense light exposures at the beginning of an individual time decay influence the detector response for the rest of the decaying signal including temporal areas, where the anode current has dropped well below the manufacturer specified current limit. Such situations are common when applying, e.g., phosphor thermometry where it is necessary to retrieve the full decay curve from a single-shot event, i.e., standard techniques based on single-photon counting are omitted. Finally, means of compensation are introduced in order to facilitate the retrieval of useful information from the measurement data when operation in the non-linear response regime is inevitable.