Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pedro Miguel Serra has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Anterior segment optical coherence tomography image spatial features in the retro-iris space

    by Pedro Serra, Ivo Soares, A. Sánchez Trancón, António Baptista

    Anterior segment optical coherence tomography (AS-OCT) is a well-established technique for imaging the anterior segment of the eye. However, AS-OCT signal is strongly absorbed and scattered by iris tissue, limiting visualization of the retro-iris space where the ciliary processes lie. This space contains no clear interfaces; it is instead dominated by a high-intensity non-anatomical signal posterior to the iris that conceals weaker backscatter from the tissue beneath. Because these contributions arise from different optical and anatomical sources, they are expected to differ in their local intensity statistics. Local descriptors of texture, dispersion and intensity range were computed across the retro-iris space in fifty AS-OCT B-scans. The resulting distributions were modelled to identify a candidate tissue backscatter component, and the descriptors were combined to produce a consensus estimate of its location. In a further twenty-four B-scans, the position of the consensus region correlated with established ocular landmarks, and the separation between the nasal and temporal regions correlated with the corresponding landmark distances. The retro-iris space therefore carries statistically distinct signal contributions, and descriptors of local intensity statistics can exploit them to localize a candidate region consistent with the ciliary process, which is otherwise obscured by iris backscattering.

  • Open Access

    Influence of Cycloplegia on Axial Length Prediction Models in a Paediatric Sample

    by Ivo Soares, António Baptista, Oscar Torrado, Pedro Serra

    Clinical Relevance: Accurate axial length (AL) estimation is vital for monitoring myopia progression in children, especially in primary care where optical biometers are often unavailable. Prediction models with cycloplegic measurements may offer a reliable alternative. Purpose: To assess the effect of cycloplegia on the accuracy and repeatability of several AL prediction models in a paediatric sample and to identify which models maintain minimal bias under both cycloplegic and non-cycloplegic conditions. Methods: Ninety-six children (mean age 12.5 ± 2.4 years) underwent repeated measurements of spherical equivalent refraction (SER), anterior corneal curvature ( K mean ) and AL, pre- and post-cycloplegia, using the Myopia Master. Seven published prediction models incorporating SER, K mean , age and sex were evaluated. Agreement, bias, limits of agreement (LoA), coefficient of repeatability (CoR), intraclass correlation coefficient (ICC) and regression analyses were used to assess performance and repeatability. Results: Cycloplegia induced a hyperopic shift (mean +0.79 D), most pronounced in emmetropic and hyperopic eyes. Measured AL and all models showed improved repeatability post-cycloplegia (measured AL CoR decreased from ~0.14 mm to ~0.09 mm; ICC > 0.99). Pre-cycloplegia, models overestimated AL (mean differences from –0.87 to –0.24 mm); these biases were reduced post-cycloplegia (mean differences from –0.56 to +0.10 mm). Models by Morgan et al., Queirós et al. and Lingham had the smallest bias (K mean contributed ≤1.2%. Conclusion: Cycloplegic refraction significantly enhanced both accuracy and repeatability of AL prediction models in children. Models by Morgan et al., Queirós et al. and Lingham et al. performed best. Predictive models may be a valuable substitute in settings without access to optical biometers, provided cycloplegic measurements are used when possible.

  • Open Access

    Bilateral Simultaneous Full-Thickness Macular Holes: A Case Report with Spontaneous Resolution

    by Isabel López-Bernal, Ángel Sánchez Trancón, Pedro Serra

    Background and Clinical Significance: Full-thickness macular hole (FTMH) is a common retinal condition that impairs detailed vision, with idiopathic causes being the most prevalent. Small macular holes (<250 µm) have the potential for spontaneous closure, whereas larger holes typically require surgical intervention to restore visual acuity (VA). The management of small macular holes remains controversial, as approximately 25% resolve spontaneously. Reporting cases of spontaneous closure may provide evidence to support a conservative, non-surgical approach in such cases. Case Presentation: We report the case of a 65-year-old female patient monitored using spectral domain optical coherence tomography (OCT). She initially presented with unilateral FTMH and subsequently developed an FTMH in the fellow eye during follow-up. Both macular holes closed spontaneously, leading to VA recovery. OCT imaging enabled the identification of vitreomacular traction as the underlying mechanism for hole formation and the bridging process responsible for spontaneous closure. Conclusions: This case highlights the potential for spontaneous anatomical and functional recovery in small-diameter macular holes (<250 µm). A conservative, observational approach may be appropriate in selected cases, potentially avoiding unnecessary surgical intervention.

  • Open Access

    Refractive Astigmatism Consistency Pre- and Post-Cycloplegia in Pediatric Population

    by Agustin Peñaranda, Oscar Torrado, Ana Márquez, António M. Baptista, Pedro M. Serra

    Background: Cycloplegic refraction is crucial in pediatric eye assessments. While spherical refraction changes due to cycloplegia are well-documented, astigmatic alterations remain unclear. This study assessed the agreement between spherical and astigmatic refraction pre- and post-cycloplegia. Methods: We enrolled 96 patients (mean age: 12.5 ± 2.4 years), including 35 myopes, 30 emmetropes, and 31 hyperopes. Pre- and post-cycloplegia autorefraction and keratometry (Myopia Master) were conducted using 1% cyclopentolate. Ocular residual astigmatism (ORA) was calculated as the difference between refractive and keratometric astigmatism. Astigmatism was analyzed using Fourier analysis (J0 and J45). Results: Cycloplegia resulted in a more positive spherical equivalent (SE) (+0.80 D), with myopes showing the smallest (+0.38 D) and hyperopes showing the highest variation (+1.47 D) in SE. With-the-rule (WTR) astigmatism predominated in the refractive and keratometric measurements, while ORA was against-the-rule (ATR). Cycloplegia shifted the refractive J0 (+0.06 D) towards more WTR and decreased ORA J0 (+0.05 D). No effect was observed in the J45 component. About 25% of patients exhibited astigmatism changes above 0.25 D, with refractive J0 variation being positively correlated with accommodation relaxation (0.044 D per D of relaxation). Conclusion: Cycloplegia induces clinically significant changes in the spherical component, but minimal variations in astigmatic components, predominantly in hyperopic eyes, likely reflecting alterations in crystalline lens anatomy.

  • Open Access

    The effect of cycloplegia in the accuracy of autorefraction, keratometry and axial length using the Myopia Master

    by Agustin Peñaranda, Oscar Torrado, Ana Márquez, António M. Baptista, Pedro Miguel Serra

    Background: Assessing refractive errors under cycloplegia is recommended for paediatric patients; however, this may not always be feasible. In these situations, refraction has to rely on measurements made under active accommodation which may increase measurements variability and error. Therefore, evaluating the accuracy and precision of non-cycloplegic refraction and biometric measurements is clinically relevant. The Myopia Master, a novel instrument combining autorefraction and biometry, is designed for monitoring refractive error and ocular biometry in myopia management. This study assessed its repeatability and agreement for autorefraction and biometric measurements pre- and post-cycloplegia. Methods: A prospective cross-sectional study evaluated a cohort of 96 paediatric patients that underwent ophthalmologic examination. An optometrist performed two repeated measurements of autorefraction and biometry pre- and post-cycloplegia. Test-retest repeatability (TRT) was assessed as differences between consecutive measurements and agreement as differences between post- and pre-cycloplegia measurements, for spherical equivalent (SE), refractive and keratometric J0/J45 astigmatic components, mean keratometry (Km) and axial length (AL). Results: Cycloplegia significantly improved the SE repeatability (TRT, pre-cyclo: 0.65 D, post-cyclo: 0.31 D). SE measurements were more repeatable in myopes and emmetropes compared to hyperopes. Keratometry (Km) repeatability did not change with cycloplegia (TRT, pre-cyclo: 0.25 D, post-cyclo:0.27 D) and AL repeatability improved marginally (TRT, pre-cyclo: 0.14 mm, post-cyclo: 0.09 mm). Regarding pre- and post-cycloplegia agreement, SE became more positive by + 0.79 D, varying with refractive error. Myopic eyes showed a mean difference of + 0.31 D, while hyperopes differed by + 1.57 D. Mean keratometry, refractive and keratometric J0/J45 and AL showed no clinically significant differences. Conclusions: Refractive error measurements, using the Myopia Master were 2.5x less precise pre-cycloplegia than post-cycloplegia. Accuracy of pre-cycloplegic refractive error measurements was often larger than the clinically significant threshold (0.25 D) and was refractive error dependent. The higher precision compared to autorefraction measurements, pre- and post-cycloplegia agreement and refractive error independence of AL measurements emphasize the superiority of AL in refractive error monitoring.


  • Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation

    by Angel Sánchez-Trancón, Santiago Cerpa Manito, Oscar Torrado Sierra, António Manuel Baptista, Pedro Miguel Serra

    Purpose This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. Methods This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. Results Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. Conclusions Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.


  • Open Access

    Clinical management of a nonoptimal vault and unexpected postoperative refraction in a patient implanted with a phakic intraocular lens

    by Angel Sánchez-Trancón, António Manuel Baptista, Oscar Torrado Sierra, Pedro Miguel Serra

    Introduction: This case reports the management of a bilateral toric implantable collamer lens (ICL) surgery with low vaulting and unilateral reduction in visual acuity (VA) associated with a combined effect of surgically induced astigmatism (SIA) and toric-ICL rotation. This case expands the common management of toric-ICL rotation, by adding surgically induced corneal changes. Patient and Clinical Findings: The patient presented with moderate myopia and high astigmatism and was implanted with a toric-ICL, resulting in bilateral low vault <150 μm and unilateral VA reduction (20/40) because of postoperative oblique astigmatism, observed at the 4-week follow-up. Diagnosis, Intervention and Outcomes: The low ICL vaulting was associated with a high crystalline lens rise and underestimation of the sulcus-to-sulcus distance. The VA reduction resulted from a combined effect of ∼1.0 diopter SIA and 8-degree ICL rotation. The authors associate the high SIA to abnormal corneal biomechanics indexes and the toric-ICL rotation to a lack of stability resultant from a small ICL size. The left eye toric-ICL has exchanged with one with larger size and the power recalculated using vectorial analysis. The toric-ICL exchange increased the vault 75 μm and improved VA. Conclusions: Detailed anterior chamber morphometry and corneal biomechanics may assist in improving the refractive outcome in toric-ICL surgery.


  • Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery

    by Angel Sánchez-Trancón, Santiago Cerpa Manito, Oscar Torrado Sierra, António Manuel Baptista, Pedro Miguel Serra

    Purpose: To determine the predictors of the postoperative horizontal trabecular iris angle (TIA750) after phakic posterior chamber implantable intraocular lens (IOL) surgery. Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. Design: Retrospective case series. Methods: 330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA750); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA750. Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA750. Results: Horizontal TIA750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA750 was positively correlated with the preoperative TIA750, cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA750 were the preoperative parameters, TIA750, ICLsize − ATA and pupil diameter (adjusted-R 2 = 0.39). The limits of agreement between predicted and real TIA750 were close to ±10 degrees. Conclusions: Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA750 and the main factors contributing for this are the preoperative TIA750 aperture and the vault.


  • Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes

    by Elisa Garcia Ardoy, Nuria Mateos, Laura Roda, Oscar Torrado Sierra, António M Baptista, Pedro M Serra

    Biometric measurements in the context of myopia are fundamental to detect eyes at risk of developing myopia and during the follow-up of patients with myopia control treatment. Thus, the accuracy of biometers has high clinical relevance. The Myopia Master is a new biometer based on partial coherence interferometry especially dedicated to the follow-up of myopic patients. This study aims to assess the repeatability of the Myopia Master and evaluate its agreement with a swept-source optical coherence interferometry biometer (IOL Master 700). This cross-sectional prospective study assessed the biometric parameters of two groups of myopes (age range: 8-16 years old), spectacle corrected (n = 60) and orthokeratology contact lens wearers (n = 60). One senior optometrist performed two consecutive measurements per instrument, which included axial length, mean keratometry and horizontal visible iris diameter (HVID). The repeatability of each device and the agreement between devices were assessed by the dispersion of the measurement differences, for AL, mean keratometry, corneal astigmatism and HVID. The two biometers measured approximately the same value in both measurements. Test-retest repeatability tended to be lower than clinical significant thresholds, in particular, for AL and mean keratometry. Corneal-related parameters tended to have lower repeatability in the orthokeratology group, especially mean keratometry. The agreement between instruments revealed statistically significant differences between devices with the SS-OCT measuring longer eyes, steeper corneas and larger HVID. In a paediatric population, the Myopia Master showed clinically acceptable repeatability levels, but the IOL Master 700 demonstrated superior repeatability. Eyes treated with orthokeratology may compromise the repeatability of the corneal-related parameters. The Myopia Master and the IOL Master 700 are repeatable devices appropriate for monitoring myopia progression, but the differences observed do not allow their use interchangeably.


  • Open Access

    Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis

    by Angel Sánchez Trancón, Santiago Cerpa Manito, Oscar Torrado Sierra, António Manuel Baptista, Pedro Miguel Serra

    Purpose: To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. Methods: This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations. Results: Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault. Conclusions: Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar.