Oscar Torrado Sierra
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oscar Torrado Sierra has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Miguel Serra
Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain
4 shared publications - António Baptista
Centre of Physics, University of Minho, Braga, Portugal
3 shared publications Angel Sánchez-Trancón
From the Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain (Sánchez-Trancón, Sierra, Serra); Centre of Physics, University of Minho, Braga, Portugal (Baptista)
2 shared publications- Agustin Peñaranda
Ophthalmology Clinic Vista Sánchez Trancón, 06010 Badajoz, Spain
1 shared publication - Ana Márquez
Ophthalmology Clinic Vista Sánchez Trancón, 06010 Badajoz, Spain
1 shared publication António Manuel Baptista
Centre of Physics, University of Minho, Braga, Portugal
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 46 (3) , 695-705
Influence of Cycloplegia on Axial Length Prediction Models in a Paediatric Sample
Clinical Relevance: Accurate axial length (AL) estimation is vital for monitoring myopia progression in children, especially in primary care where optical biometers are often unavailable. Prediction models with cycloplegic measurements may offer a reliable alternative. Purpose: To assess the effect of cycloplegia on the accuracy and repeatability of several AL prediction models in a paediatric sample and to identify which models maintain minimal bias under both cycloplegic and non-cycloplegic conditions. Methods: Ninety-six children (mean age 12.5 ± 2.4 years) underwent repeated measurements of spherical equivalent refraction (SER), anterior corneal curvature ( K mean ) and AL, pre- and post-cycloplegia, using the Myopia Master. Seven published prediction models incorporating SER, K mean , age and sex were evaluated. Agreement, bias, limits of agreement (LoA), coefficient of repeatability (CoR), intraclass correlation coefficient (ICC) and regression analyses were used to assess performance and repeatability. Results: Cycloplegia induced a hyperopic shift (mean +0.79 D), most pronounced in emmetropic and hyperopic eyes. Measured AL and all models showed improved repeatability post-cycloplegia (measured AL CoR decreased from ~0.14 mm to ~0.09 mm; ICC > 0.99). Pre-cycloplegia, models overestimated AL (mean differences from –0.87 to –0.24 mm); these biases were reduced post-cycloplegia (mean differences from –0.56 to +0.10 mm). Models by Morgan et al., Queirós et al. and Lingham had the smallest bias (K mean contributed ≤1.2%. Conclusion: Cycloplegic refraction significantly enhanced both accuracy and repeatability of AL prediction models in children. Models by Morgan et al., Queirós et al. and Lingham et al. performed best. Predictive models may be a valuable substitute in settings without access to optical biometers, provided cycloplegic measurements are used when possible.
- 18 May 2026
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 46 (3) , 695-705
Open AccessInfluence of Cycloplegia on Axial Length Prediction Models in a Paediatric Sample
Clinical Relevance: Accurate axial length (AL) estimation is vital for monitoring myopia progression in children, especially in primary care where optical biometers are often unavailable. Prediction models with cycloplegic measurements may offer a reliable alternative. Purpose: To assess the effect of cycloplegia on the accuracy and repeatability of several AL prediction models in a paediatric sample and to identify which models maintain minimal bias under both cycloplegic and non-cycloplegic conditions. Methods: Ninety-six children (mean age 12.5 ± 2.4 years) underwent repeated measurements of spherical equivalent refraction (SER), anterior corneal curvature ( K mean ) and AL, pre- and post-cycloplegia, using the Myopia Master. Seven published prediction models incorporating SER, K mean , age and sex were evaluated. Agreement, bias, limits of agreement (LoA), coefficient of repeatability (CoR), intraclass correlation coefficient (ICC) and regression analyses were used to assess performance and repeatability. Results: Cycloplegia induced a hyperopic shift (mean +0.79 D), most pronounced in emmetropic and hyperopic eyes. Measured AL and all models showed improved repeatability post-cycloplegia (measured AL CoR decreased from ~0.14 mm to ~0.09 mm; ICC > 0.99). Pre-cycloplegia, models overestimated AL (mean differences from –0.87 to –0.24 mm); these biases were reduced post-cycloplegia (mean differences from –0.56 to +0.10 mm). Models by Morgan et al., Queirós et al. and Lingham had the smallest bias (K mean contributed ≤1.2%. Conclusion: Cycloplegic refraction significantly enhanced both accuracy and repeatability of AL prediction models in children. Models by Morgan et al., Queirós et al. and Lingham et al. performed best. Predictive models may be a valuable substitute in settings without access to optical biometers, provided cycloplegic measurements are used when possible.
- Open Access
- 18 December 2024
- Published by MDPI AG in Journal of Clinical & Translational Ophthalmology
- Vol. 2 (4) , 181-194
Refractive Astigmatism Consistency Pre- and Post-Cycloplegia in Pediatric Population
Background: Cycloplegic refraction is crucial in pediatric eye assessments. While spherical refraction changes due to cycloplegia are well-documented, astigmatic alterations remain unclear. This study assessed the agreement between spherical and astigmatic refraction pre- and post-cycloplegia. Methods: We enrolled 96 patients (mean age: 12.5 ± 2.4 years), including 35 myopes, 30 emmetropes, and 31 hyperopes. Pre- and post-cycloplegia autorefraction and keratometry (Myopia Master) were conducted using 1% cyclopentolate. Ocular residual astigmatism (ORA) was calculated as the difference between refractive and keratometric astigmatism. Astigmatism was analyzed using Fourier analysis (J0 and J45). Results: Cycloplegia resulted in a more positive spherical equivalent (SE) (+0.80 D), with myopes showing the smallest (+0.38 D) and hyperopes showing the highest variation (+1.47 D) in SE. With-the-rule (WTR) astigmatism predominated in the refractive and keratometric measurements, while ORA was against-the-rule (ATR). Cycloplegia shifted the refractive J0 (+0.06 D) towards more WTR and decreased ORA J0 (+0.05 D). No effect was observed in the J45 component. About 25% of patients exhibited astigmatism changes above 0.25 D, with refractive J0 variation being positively correlated with accommodation relaxation (0.044 D per D of relaxation). Conclusion: Cycloplegia induces clinically significant changes in the spherical component, but minimal variations in astigmatic components, predominantly in hyperopic eyes, likely reflecting alterations in crystalline lens anatomy.
- 18 December 2024
- Published by MDPI AG in Journal of Clinical & Translational Ophthalmology
- Vol. 2 (4) , 181-194
Open AccessRefractive Astigmatism Consistency Pre- and Post-Cycloplegia in Pediatric Population
Background: Cycloplegic refraction is crucial in pediatric eye assessments. While spherical refraction changes due to cycloplegia are well-documented, astigmatic alterations remain unclear. This study assessed the agreement between spherical and astigmatic refraction pre- and post-cycloplegia. Methods: We enrolled 96 patients (mean age: 12.5 ± 2.4 years), including 35 myopes, 30 emmetropes, and 31 hyperopes. Pre- and post-cycloplegia autorefraction and keratometry (Myopia Master) were conducted using 1% cyclopentolate. Ocular residual astigmatism (ORA) was calculated as the difference between refractive and keratometric astigmatism. Astigmatism was analyzed using Fourier analysis (J0 and J45). Results: Cycloplegia resulted in a more positive spherical equivalent (SE) (+0.80 D), with myopes showing the smallest (+0.38 D) and hyperopes showing the highest variation (+1.47 D) in SE. With-the-rule (WTR) astigmatism predominated in the refractive and keratometric measurements, while ORA was against-the-rule (ATR). Cycloplegia shifted the refractive J0 (+0.06 D) towards more WTR and decreased ORA J0 (+0.05 D). No effect was observed in the J45 component. About 25% of patients exhibited astigmatism changes above 0.25 D, with refractive J0 variation being positively correlated with accommodation relaxation (0.044 D per D of relaxation). Conclusion: Cycloplegia induces clinically significant changes in the spherical component, but minimal variations in astigmatic components, predominantly in hyperopic eyes, likely reflecting alterations in crystalline lens anatomy.
- Open Access
- 16 November 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 12 (1) , e00112
Clinical management of a nonoptimal vault and unexpected postoperative refraction in a patient implanted with a phakic intraocular lens
Introduction: This case reports the management of a bilateral toric implantable collamer lens (ICL) surgery with low vaulting and unilateral reduction in visual acuity (VA) associated with a combined effect of surgically induced astigmatism (SIA) and toric-ICL rotation. This case expands the common management of toric-ICL rotation, by adding surgically induced corneal changes. Patient and Clinical Findings: The patient presented with moderate myopia and high astigmatism and was implanted with a toric-ICL, resulting in bilateral low vault <150 μm and unilateral VA reduction (20/40) because of postoperative oblique astigmatism, observed at the 4-week follow-up. Diagnosis, Intervention and Outcomes: The low ICL vaulting was associated with a high crystalline lens rise and underestimation of the sulcus-to-sulcus distance. The VA reduction resulted from a combined effect of ∼1.0 diopter SIA and 8-degree ICL rotation. The authors associate the high SIA to abnormal corneal biomechanics indexes and the toric-ICL rotation to a lack of stability resultant from a small ICL size. The left eye toric-ICL has exchanged with one with larger size and the power recalculated using vectorial analysis. The toric-ICL exchange increased the vault 75 μm and improved VA. Conclusions: Detailed anterior chamber morphometry and corneal biomechanics may assist in improving the refractive outcome in toric-ICL surgery.
- 16 November 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 12 (1) , e00112
Open AccessClinical management of a nonoptimal vault and unexpected postoperative refraction in a patient implanted with a phakic intraocular lens
Introduction: This case reports the management of a bilateral toric implantable collamer lens (ICL) surgery with low vaulting and unilateral reduction in visual acuity (VA) associated with a combined effect of surgically induced astigmatism (SIA) and toric-ICL rotation. This case expands the common management of toric-ICL rotation, by adding surgically induced corneal changes. Patient and Clinical Findings: The patient presented with moderate myopia and high astigmatism and was implanted with a toric-ICL, resulting in bilateral low vault <150 μm and unilateral VA reduction (20/40) because of postoperative oblique astigmatism, observed at the 4-week follow-up. Diagnosis, Intervention and Outcomes: The low ICL vaulting was associated with a high crystalline lens rise and underestimation of the sulcus-to-sulcus distance. The VA reduction resulted from a combined effect of ∼1.0 diopter SIA and 8-degree ICL rotation. The authors associate the high SIA to abnormal corneal biomechanics indexes and the toric-ICL rotation to a lack of stability resultant from a small ICL size. The left eye toric-ICL has exchanged with one with larger size and the power recalculated using vectorial analysis. The toric-ICL exchange increased the vault 75 μm and improved VA. Conclusions: Detailed anterior chamber morphometry and corneal biomechanics may assist in improving the refractive outcome in toric-ICL surgery.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 732-739
Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery
Purpose: To determine the predictors of the postoperative horizontal trabecular iris angle (TIA750) after phakic posterior chamber implantable intraocular lens (IOL) surgery. Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. Design: Retrospective case series. Methods: 330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA750); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA750. Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA750. Results: Horizontal TIA750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA750 was positively correlated with the preoperative TIA750, cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA750 were the preoperative parameters, TIA750, ICLsize − ATA and pupil diameter (adjusted-R 2 = 0.39). The limits of agreement between predicted and real TIA750 were close to ±10 degrees. Conclusions: Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA750 and the main factors contributing for this are the preoperative TIA750 aperture and the vault.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 732-739
Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery
Purpose: To determine the predictors of the postoperative horizontal trabecular iris angle (TIA750) after phakic posterior chamber implantable intraocular lens (IOL) surgery. Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. Design: Retrospective case series. Methods: 330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA750); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA750. Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA750. Results: Horizontal TIA750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA750 was positively correlated with the preoperative TIA750, cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA750 were the preoperative parameters, TIA750, ICLsize − ATA and pupil diameter (adjusted-R 2 = 0.39). The limits of agreement between predicted and real TIA750 were close to ±10 degrees. Conclusions: Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA750 and the main factors contributing for this are the preoperative TIA750 aperture and the vault.