Subhi M. Bazlamit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Subhi M. Bazlamit has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hesham Rabayah
Department of Civil and Infrastructure Engineering, Al-Zaytoonah University of Jordan, P.O. Box 130, Amman 11733, Jordan
2 shared publications - Malik I. Al-Amayreh
AL-Zaytoonah University of Jordan
2 shared publications - Ali Alahmer
Department of Mechanical Engineering, Tuskegee University, Tuskegee, USA
1 shared publication - Farhad Reza
Professor, Department of Mechanical and Civil Engineering, Minnesota State University, Mankato, MN, USA
1 shared publication - Fawzi Suleiman Gharagheer
Department of Civil Engineering, Zarqa University, Zarqa, Jordan
1 shared publication - Mai Bani Younes
Department of Alternative Energy Technology, Faculty of Engineering and Technology, Al-Zaytoonah University of Jordan, Amman, Jordan
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by Engineering, Project, and Production Management (EPPM) in Journal of Engineering, Project, and Production Management
- Vol. 14 (3) , 1-10
Integrating Industry 4.0 Concepts in Civil Engineering Education
- 1 September 2024
- Published by Engineering, Project, and Production Management (EPPM) in Journal of Engineering, Project, and Production Management
- Vol. 14 (3) , 1-10
Open AccessIntegrating Industry 4.0 Concepts in Civil Engineering Education
- 1 January 2024
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 36 (1) , 31-43
Cryogenic cooling using liquid nitrogen to produce massive concrete: temperature, setting time and compressive strength
Mixing cement with water in mass concrete production is associated with hydration heat generation, which may cause concrete mixes to dry out and crack. The experimental work aims to evaluate the effects of using liquid nitrogen (LN) in cooling mortar mixes and concrete. LN was used in doses of 0, 25, 50, 75 and 100% by water volume to either cool the mixing water at T = 4°C or to inject it into concrete mixtures directly. The concrete mix proportions were based on ACI PRC-207.1-21 for mass concrete. The mortars' initial and final setting times and temperatures indicated that a greater percentage of LN delayed the hardening process and the peak hardening rates, exhibiting slower cement hydration. LN cooling enhances the compressive strength of mortar and concrete cubes when VLN/Vwater≤1. However, concrete compressive strength decreased due to ice formation that turned into voids when VLN/Vwater>1. Cooling concrete with chilled water (T = 4°C) showed a 30% and 34.51% increase in mortar and concrete cubes' compressive strength, respectively, and a maximum of 16.45% and 12.97% when LN was injected into mortars and concrete mixes. Cooling the concrete with chilled water (T = 4°C) showed a slower cooling process, which improved cement hydration results.
- 1 January 2024
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 36 (1) , 31-43
Cryogenic cooling using liquid nitrogen to produce massive concrete: temperature, setting time and compressive strength
Mixing cement with water in mass concrete production is associated with hydration heat generation, which may cause concrete mixes to dry out and crack. The experimental work aims to evaluate the effects of using liquid nitrogen (LN) in cooling mortar mixes and concrete. LN was used in doses of 0, 25, 50, 75 and 100% by water volume to either cool the mixing water at T = 4°C or to inject it into concrete mixtures directly. The concrete mix proportions were based on ACI PRC-207.1-21 for mass concrete. The mortars' initial and final setting times and temperatures indicated that a greater percentage of LN delayed the hardening process and the peak hardening rates, exhibiting slower cement hydration. LN cooling enhances the compressive strength of mortar and concrete cubes when VLN/Vwater≤1. However, concrete compressive strength decreased due to ice formation that turned into voids when VLN/Vwater>1. Cooling concrete with chilled water (T = 4°C) showed a 30% and 34.51% increase in mortar and concrete cubes' compressive strength, respectively, and a maximum of 16.45% and 12.97% when LN was injected into mortars and concrete mixes. Cooling the concrete with chilled water (T = 4°C) showed a slower cooling process, which improved cement hydration results.
- 1 August 2022
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Transport
- Vol. 175 (5) , 284-289
Thermal changes in concrete pavement skid resistance
Concrete pavements comprise a considerable portion of pavements that are currently in use. This paper presents the results from a laboratory investigation on the effect of temperature and surface texture on the skid resistance of concrete pavements. Briquettes representative of concrete pavements were created and textured in the laboratory. Readings of skid resistance on laboratory specimens were obtained using a portable British pendulum tester. Water and liquid hand soaps were used as lubricants in an attempt to separate the adhesion and hysteresis components of friction. In order to simulate the wear and ageing of concrete pavements, several cycles of polishing were applied to the briquettes. Tests were conducted at five different temperatures. The results showed that there is a correlation between the magnitude of friction components and temperature. A normalisation procedure for friction measurements based on temperature was developed, which can be used to normalise measurements to a standard temperature of 293·15 K.
- 1 August 2022
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Transport
- Vol. 175 (5) , 284-289
Thermal changes in concrete pavement skid resistance
Concrete pavements comprise a considerable portion of pavements that are currently in use. This paper presents the results from a laboratory investigation on the effect of temperature and surface texture on the skid resistance of concrete pavements. Briquettes representative of concrete pavements were created and textured in the laboratory. Readings of skid resistance on laboratory specimens were obtained using a portable British pendulum tester. Water and liquid hand soaps were used as lubricants in an attempt to separate the adhesion and hysteresis components of friction. In order to simulate the wear and ageing of concrete pavements, several cycles of polishing were applied to the briquettes. Tests were conducted at five different temperatures. The results showed that there is a correlation between the magnitude of friction components and temperature. A normalisation procedure for friction measurements based on temperature was developed, which can be used to normalise measurements to a standard temperature of 293·15 K.
- Open Access
Pre-Cooling Concrete System in Massive Concrete Production: Energy Analysis and Refrigerant Replacement
Several techniques for cooling mass concrete structures were developed in order to increase structural integrity and reduce the influence of cement hydration, which sometimes causes cracking in concrete structures, negatively affecting their durability. This research focuses on cooling system design, initial investment, and the influence of different refrigerants on cooling system performance aims in producing higher quality massive concrete. Cooling aggregates in massive concrete structures such as desert dams can be performed by employing cooled air from an air conditioning duct system or chilled water. The experimental study illustrates the relationship between the coefficient of performance COP, the evaporator temperature, cooling capacity, and refrigerant mass flow rate as a function of the evaporator temperature, cooling capacity, and refrigerant mass flow rate. The findings of the experiments were utilized to verify a numerical model developed utilizing engineering equation solver (EES) software. The performance of the vapor compression of the cooling systems was compared using alternative refrigerants, including R22, R32, and R410a at different operating conditions. This study revealed that R22 refrigerant has a higher coefficient of performance than R32 and R410A, while R32 has the highest cooling capacity among other refrigerants.
Open AccessPre-Cooling Concrete System in Massive Concrete Production: Energy Analysis and Refrigerant Replacement
Several techniques for cooling mass concrete structures were developed in order to increase structural integrity and reduce the influence of cement hydration, which sometimes causes cracking in concrete structures, negatively affecting their durability. This research focuses on cooling system design, initial investment, and the influence of different refrigerants on cooling system performance aims in producing higher quality massive concrete. Cooling aggregates in massive concrete structures such as desert dams can be performed by employing cooled air from an air conditioning duct system or chilled water. The experimental study illustrates the relationship between the coefficient of performance COP, the evaporator temperature, cooling capacity, and refrigerant mass flow rate as a function of the evaporator temperature, cooling capacity, and refrigerant mass flow rate. The findings of the experiments were utilized to verify a numerical model developed utilizing engineering equation solver (EES) software. The performance of the vapor compression of the cooling systems was compared using alternative refrigerants, including R22, R32, and R410a at different operating conditions. This study revealed that R22 refrigerant has a higher coefficient of performance than R32 and R410A, while R32 has the highest cooling capacity among other refrigerants.
- 1 December 2019
- Published by Emerald Publishing in Journal of Environmental Engineering and Science
- Vol. 14 (4) , 212-217
Recovery of recyclables of municipal solid waste: the case of Jordan
The low recyclable recovery (RR) rate of municipal solid waste (MSW) (7·0%) in Jordan compared to the average recovery rate of the members of the EU (42%) indicates the necessity of changing the current practices of RR being implemented in Jordan where the latest national strategy of MSW management, launched by the Ministry of Municipal Affairs in May 2015, aims to achieve an RR rate of 50% by the year 2034. This research aims to identify the attributes of an efficient and successful RR programme and recommend an implementable plan for RR that can achieve the target of 50% earlier than the year 2034. Practices of RR currently being implemented in Jordan are analysed and compared with successful practices implemented in developed countries. A public–private partnership is suggested to establish and operate semi-mechanical RR facilities that use the resources currently owned and operated by Joint Service Councils and local municipalities. Utilising the current resources enables the country to achieve the 50% RR rate goal. The rough financial analysis conducted clearly indicates that the 20% RR rate of plastic alone can offset the deficit in the municipality budget resulting from MSW management in Jordan.
- 1 December 2019
- Published by Emerald Publishing in Journal of Environmental Engineering and Science
- Vol. 14 (4) , 212-217
Recovery of recyclables of municipal solid waste: the case of Jordan
The low recyclable recovery (RR) rate of municipal solid waste (MSW) (7·0%) in Jordan compared to the average recovery rate of the members of the EU (42%) indicates the necessity of changing the current practices of RR being implemented in Jordan where the latest national strategy of MSW management, launched by the Ministry of Municipal Affairs in May 2015, aims to achieve an RR rate of 50% by the year 2034. This research aims to identify the attributes of an efficient and successful RR programme and recommend an implementable plan for RR that can achieve the target of 50% earlier than the year 2034. Practices of RR currently being implemented in Jordan are analysed and compared with successful practices implemented in developed countries. A public–private partnership is suggested to establish and operate semi-mechanical RR facilities that use the resources currently owned and operated by Joint Service Councils and local municipalities. Utilising the current resources enables the country to achieve the 50% RR rate goal. The rough financial analysis conducted clearly indicates that the 20% RR rate of plastic alone can offset the deficit in the municipality budget resulting from MSW management in Jordan.