Peipei Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peipei Zhou has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Huili Wang
School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, China
4 shared publications- Xuedong Wang
School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
4 shared publications Ru Fan
Zhejiang Provincial Key Laboratory of Watershed Science and Health, College of Public Health, Wenzhou Medical University, Wenzhou, China
3 shared publications- He Mei
Zhejiang Provincial Key Laboratory of Watershed Science and Health, School of Public Health, Wenzhou Medical University, Wenzhou 325035, PR China; South Zhejiang Institute of Radiation Medicine and Nuclear Technology, Wenzhou 325809, PR China
2 shared publications - Wei Liu
State Key Laboratory of Green and Efficient Development of Phosphorus Resources, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, School of Chemical Engineering and Pharmacy, Wuhan Institute of Technology, Wuhan 430205, People's Republic of China
2 shared publications Chao Sun
1 shared publication
Latest Publications
- 18 September 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (38) , 16844-16852
One-step effervescent tablet-assisted dispersive solid-phase microextraction based on an l -cysteine-functionalized carbon-coated magnetic nanocomposite for the determination of iron and zinc ions in milk samples
In this study, a L-cysteine-functionalized carbon-coated magnetic nanocomposite (CoFe2O4/C@Cys) was effectively synthesized and employed as an adsorbent in effervescent tablet-assisted dispersive solid-phase microextraction (ET-DSPM) for enrichment of heavy metals (Fe(III) and Zn(II)). The as-prepared composites were extensively characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and vibrating sample magnetometer (VSM) techniques. The influence of various factors on the extraction efficiency of heavy metals was methodically examined in this study. After quickly transferring the effervescence tablet into the aqueous sample, the effervescent agent (sodium dihydrogen phosphate and sodium carbonate) simultaneously reacted and produced carbon dioxide (CO2). The in situ produced CO2 facilitated the dispersion of nanoparticles in the aqueous sample and significantly enhanced the extraction efficiency. Under the optimal parameters, the results showed that the CoFe2O4/C@Cys-ET-DSPM method displayed superior analytical performance for quantification of two heavy metals in milk samples with a preconcentration factor of 20, limits of detection (LODs) of 0.10–0.12 μg kg−1, recoveries of 77.1–101.7% and RSDs of 1.1–7.0%, respectively. The one-step extraction approach combined with an atomic absorption spectrometer exhibits promising potential for application in field analysis.
- 18 September 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (38) , 16844-16852
One-step effervescent tablet-assisted dispersive solid-phase microextraction based on an l -cysteine-functionalized carbon-coated magnetic nanocomposite for the determination of iron and zinc ions in milk samples
In this study, a L-cysteine-functionalized carbon-coated magnetic nanocomposite (CoFe2O4/C@Cys) was effectively synthesized and employed as an adsorbent in effervescent tablet-assisted dispersive solid-phase microextraction (ET-DSPM) for enrichment of heavy metals (Fe(III) and Zn(II)). The as-prepared composites were extensively characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and vibrating sample magnetometer (VSM) techniques. The influence of various factors on the extraction efficiency of heavy metals was methodically examined in this study. After quickly transferring the effervescence tablet into the aqueous sample, the effervescent agent (sodium dihydrogen phosphate and sodium carbonate) simultaneously reacted and produced carbon dioxide (CO2). The in situ produced CO2 facilitated the dispersion of nanoparticles in the aqueous sample and significantly enhanced the extraction efficiency. Under the optimal parameters, the results showed that the CoFe2O4/C@Cys-ET-DSPM method displayed superior analytical performance for quantification of two heavy metals in milk samples with a preconcentration factor of 20, limits of detection (LODs) of 0.10–0.12 μg kg−1, recoveries of 77.1–101.7% and RSDs of 1.1–7.0%, respectively. The one-step extraction approach combined with an atomic absorption spectrometer exhibits promising potential for application in field analysis.
- 24 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
Integration of Myrica rubra–based N-doped carbon dots with Fe3S4 as excellent peroxidase mimics for colorimetric assay and smartphone-based intelligent sensing of p-aminophenol in waters
To realize the reutilization of waste Myrica rubra in the analytical field, we synthesized Myrica rubra–based N-doped carbon dots (MN-CDs) and further anchored them onto the surface of Fe3S4 to fabricate Fe3S4@MN-CD nanocomposites. The as-fabricated nanocomposites possessed higher peroxidase-mimetic activity than its two precursors, resulting from the synergistic effect between them, and could catalyze colorless 3,3′,5,5′-tetramethylbenzidine (TMB) into deep blue oxTMB with a strong 652-nm absorption. Under optimized conditions (initial solution pH, 3.5; incubation temperature, 35 ℃; Fe3S4@MN-CD concentration, 50 µg mL−1, and 652-nm absorption), Fe3S4@MN-CDs were employed for colorimetric assay of p-aminophenol (p-AP) with wide linear range (LR, 2.9–100 µM), low detection limit (LOD, 0.87 µM), and satisfactory recoveries (86.3–105%) in environmental waters. Encouragingly, this colorimetric assay provided the relative accuracy of 97.0–99.4% as compared with conventional HPLC-UV detection. A portable smartphone-based colorimetric application was developed by combining the Fe3S4@MN-CD-based visually chromogenic reaction with a “Thing Identify” APP software. Besides, we engineered an image-capturing device feasible for field use, in which the internal-compact sealing prevented external light source from entering photography chamber, thereby reducing light interference, and also the bottom light source enhanced the intensity of blue imaging. This colorimetric platform exhibited satisfactory LR (1–500 µM), low LOD (0.3 µM), and fortification recoveries (86.6–99.6%). In the chromogenic reaction catalyzed by Fe3S4@MN-CDs, ·O2− played a key role in concomitant with the participation of •OH and h+. Both the colorimetric assay and smartphone-based intelligent sensing show great promising in on-site monitoring of p-AP under field conditions. Graphical Abstract
- 24 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
Integration of Myrica rubra–based N-doped carbon dots with Fe3S4 as excellent peroxidase mimics for colorimetric assay and smartphone-based intelligent sensing of p-aminophenol in waters
To realize the reutilization of waste Myrica rubra in the analytical field, we synthesized Myrica rubra–based N-doped carbon dots (MN-CDs) and further anchored them onto the surface of Fe3S4 to fabricate Fe3S4@MN-CD nanocomposites. The as-fabricated nanocomposites possessed higher peroxidase-mimetic activity than its two precursors, resulting from the synergistic effect between them, and could catalyze colorless 3,3′,5,5′-tetramethylbenzidine (TMB) into deep blue oxTMB with a strong 652-nm absorption. Under optimized conditions (initial solution pH, 3.5; incubation temperature, 35 ℃; Fe3S4@MN-CD concentration, 50 µg mL−1, and 652-nm absorption), Fe3S4@MN-CDs were employed for colorimetric assay of p-aminophenol (p-AP) with wide linear range (LR, 2.9–100 µM), low detection limit (LOD, 0.87 µM), and satisfactory recoveries (86.3–105%) in environmental waters. Encouragingly, this colorimetric assay provided the relative accuracy of 97.0–99.4% as compared with conventional HPLC-UV detection. A portable smartphone-based colorimetric application was developed by combining the Fe3S4@MN-CD-based visually chromogenic reaction with a “Thing Identify” APP software. Besides, we engineered an image-capturing device feasible for field use, in which the internal-compact sealing prevented external light source from entering photography chamber, thereby reducing light interference, and also the bottom light source enhanced the intensity of blue imaging. This colorimetric platform exhibited satisfactory LR (1–500 µM), low LOD (0.3 µM), and fortification recoveries (86.6–99.6%). In the chromogenic reaction catalyzed by Fe3S4@MN-CDs, ·O2− played a key role in concomitant with the participation of •OH and h+. Both the colorimetric assay and smartphone-based intelligent sensing show great promising in on-site monitoring of p-AP under field conditions. Graphical Abstract
- 16 September 2023
- Published by Elsevier in Food Chemistry
- Vol. 434, 137507
Manganese dioxide nanosheet-modulated ratiometric fluoroprobe based on carbon quantum dots from okra for selective and sensitive dichlorvos detection in foods
- 16 September 2023
- Published by Elsevier in Food Chemistry
- Vol. 434, 137507
Manganese dioxide nanosheet-modulated ratiometric fluoroprobe based on carbon quantum dots from okra for selective and sensitive dichlorvos detection in foods
- Open Access
- 24 February 2023
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 32 (3) , 2221-2230
Daily-Scale Runoff Simulation of Shanxi Drinking Water Based on SWAT Model, Using Separation Dry and Wet Season Calibration Method
In this study, by establishing a daily scale SWAT model with dry and wet seasons separated in the study area, the sensitivity and uncertainty of parameters in the typhoon-affected area are discussed. At the same time quantitative analysis of the temporal and spatial characteristics of water resources. The results show that 1) the sensitivity parameters in the dry and wet seasons are very different. The most sensitive parameters are ALPHA_BF.gw and CN_2.mgt, but the least sensitive parameters are SURLAG.bsn and GWQMN.gw, respectively. This is obviously related to the meteorological conditions of the two periods. 2) Uncertainty analysis shows that the uncertainty of model parameters is mainly caused by extreme daily runoff parameters. 3) Except that the NSE and R2 of the wet season model are slightly lower than 0.7, the NSE and R2 of the dry season are higher than 0.73, and the PBIAS in both periods is within 10%. This shows that the application of separate calibration methods improves the accuracy of the model. 4) The correlation between wet season precipitation and runoff is higher than 0.98. The average wet season runoff for many years accounts for 81.44% of the annual runoff, which is the main period of runoff generation. The key source area of runoff is 51.04% of the total area of the river basin, and the runoff flow accounts for 54.21% of the total runoff of the land. It should be protected.
- 24 February 2023
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 32 (3) , 2221-2230
Open AccessDaily-Scale Runoff Simulation of Shanxi Drinking Water Based on SWAT Model, Using Separation Dry and Wet Season Calibration Method
In this study, by establishing a daily scale SWAT model with dry and wet seasons separated in the study area, the sensitivity and uncertainty of parameters in the typhoon-affected area are discussed. At the same time quantitative analysis of the temporal and spatial characteristics of water resources. The results show that 1) the sensitivity parameters in the dry and wet seasons are very different. The most sensitive parameters are ALPHA_BF.gw and CN_2.mgt, but the least sensitive parameters are SURLAG.bsn and GWQMN.gw, respectively. This is obviously related to the meteorological conditions of the two periods. 2) Uncertainty analysis shows that the uncertainty of model parameters is mainly caused by extreme daily runoff parameters. 3) Except that the NSE and R2 of the wet season model are slightly lower than 0.7, the NSE and R2 of the dry season are higher than 0.73, and the PBIAS in both periods is within 10%. This shows that the application of separate calibration methods improves the accuracy of the model. 4) The correlation between wet season precipitation and runoff is higher than 0.98. The average wet season runoff for many years accounts for 81.44% of the annual runoff, which is the main period of runoff generation. The key source area of runoff is 51.04% of the total area of the river basin, and the runoff flow accounts for 54.21% of the total runoff of the land. It should be protected.
- 19 October 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (11) , 1-10
Sensitive colorimetric assay of hydrogen peroxide and glucose in humoral samples based on the enhanced peroxidase-mimetic activity of NH2-MIL-88-derived FeS2@CN nanocomposites compared to its precursors
By employing NH2-MIL-88 as a template, we synthesized the intermediate Fe@CN under high-temperature calcination and further fabricated the FeS2@CN nanocomposites in the presence of sulfur powder. Under varying temperatures (300–600 °C) and Fe@CN-to-S ratios (1:3–6), FeS2@CN500-5 nanocomposites had the highest peroxidase-mimetic activity. Under optimized conditions (incubation temperature 40 °C; solution pH 4.0 and nanocomposite concentration 10 μg/mL; 652-nm absorption), the Michaelis-Menten constant (Km) of FeS2@CN was much lower than that of horseradish peroxidase (HRP), therefore demonstrating that it had a higher affinity for both chromogenic substrates than conventional HRP. The limits of detection for H2O2 and glucose were 0.15 and 0.30 μmol/L, respectively, and the recoveries for glucose were 91.8–103% with RSDs 2@CN was confirmed to possess stronger enzyme-mimetic activity than its precursors (NH2-MIL-88 and Fe@CN); (2) the enhanced activity resulted from the unsaturated sites of N and S doping and the plentiful defects on the porous carbon surface; and (3) free radical trapping experiments evidenced that •OH played a major role in the catalytic reaction, while h+ and •O2− simultaneously participated in the catalytic process. These convincing performance metrics lead us to postulate that the FeS2@CN-based colorimetric biosensor provides a promising approach for several real-world applications, such as point-of-care diagnosis and workplace health evaluations. Graphical abstract
- 19 October 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (11) , 1-10
Sensitive colorimetric assay of hydrogen peroxide and glucose in humoral samples based on the enhanced peroxidase-mimetic activity of NH2-MIL-88-derived FeS2@CN nanocomposites compared to its precursors
By employing NH2-MIL-88 as a template, we synthesized the intermediate Fe@CN under high-temperature calcination and further fabricated the FeS2@CN nanocomposites in the presence of sulfur powder. Under varying temperatures (300–600 °C) and Fe@CN-to-S ratios (1:3–6), FeS2@CN500-5 nanocomposites had the highest peroxidase-mimetic activity. Under optimized conditions (incubation temperature 40 °C; solution pH 4.0 and nanocomposite concentration 10 μg/mL; 652-nm absorption), the Michaelis-Menten constant (Km) of FeS2@CN was much lower than that of horseradish peroxidase (HRP), therefore demonstrating that it had a higher affinity for both chromogenic substrates than conventional HRP. The limits of detection for H2O2 and glucose were 0.15 and 0.30 μmol/L, respectively, and the recoveries for glucose were 91.8–103% with RSDs 2@CN was confirmed to possess stronger enzyme-mimetic activity than its precursors (NH2-MIL-88 and Fe@CN); (2) the enhanced activity resulted from the unsaturated sites of N and S doping and the plentiful defects on the porous carbon surface; and (3) free radical trapping experiments evidenced that •OH played a major role in the catalytic reaction, while h+ and •O2− simultaneously participated in the catalytic process. These convincing performance metrics lead us to postulate that the FeS2@CN-based colorimetric biosensor provides a promising approach for several real-world applications, such as point-of-care diagnosis and workplace health evaluations. Graphical abstract
- Open Access
- 25 February 2022
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 233, 113350
Reuse of waste Myrica rubra for green synthesis of nitrogen-doped carbon dots as an “on-off-on” fluorescent probe for Fe3+ and ascorbic acid detection
- 25 February 2022
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 233, 113350
Open AccessReuse of waste Myrica rubra for green synthesis of nitrogen-doped carbon dots as an “on-off-on” fluorescent probe for Fe3+ and ascorbic acid detection
- 22 June 2021
- Published by Springer Nature in Journal of Food Measurement and Characterization
- Vol. 15 (5) , 4482-4489
Pre-column derivatization and HPLC-ESI-MS/MS determination of fatty acids in Sargassum fusiforme algae
- 22 June 2021
- Published by Springer Nature in Journal of Food Measurement and Characterization
- Vol. 15 (5) , 4482-4489
Pre-column derivatization and HPLC-ESI-MS/MS determination of fatty acids in Sargassum fusiforme algae
- 13 December 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (3) , 598-606
Development of an effervescent tablet microextraction method using NiFe 2 O 4 -based magnetic nanoparticles for preconcentration/extraction of heavy metals prior to ICP-MS analysis of seafood
A novel magnetic NiFe 2 O 4 -based effervescent tablet-assisted dispersive solid-phase microextraction (MNET-DSPM) was developed for extraction of metal ions prior to ICP-MS.
- 13 December 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (3) , 598-606
Development of an effervescent tablet microextraction method using NiFe 2 O 4 -based magnetic nanoparticles for preconcentration/extraction of heavy metals prior to ICP-MS analysis of seafood
A novel magnetic NiFe 2 O 4 -based effervescent tablet-assisted dispersive solid-phase microextraction (MNET-DSPM) was developed for extraction of metal ions prior to ICP-MS.