Hitomi Mukaibo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Hitomi Mukaibo has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Tetsuya Osaka
Waseda University
10 shared publications - Toshiyuki Momma
Graduate School of Advanced Science and Engineering, Waseda University, 3-4-1, Okubo, Shinjuku-ku, Tokyo, 169-8555, Japan
10 shared publications Andrew R. Durney
5 shared publicationsCharles R. Martin
4 shared publications- Hiroki Nara
Research Organization for Nano and Life Innovation, Waseda University, 513, Wasedatsurumakicho, Shinjuku-ku, Tokyo 162-0041, Japan
3 shared publications Lloyd P. Horne
Department of Chemistry and Center for Research at the Bio/Nano Interface, University of Florida, Gainesville, Florida 32611-7200, Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611-6400, Department of Biomedical Engineering, Columbia University, New York, New York 10027, and Department of Chemistry, University of Maryland, College Park, Maryland 20742
3 shared publications
Latest Publications
- 2 November 2018
- Published by Wiley in The Chemical Record
- Vol. 19 (5) , 859-872
Template‐Synthesized Vertical Needle Array as Injection Platform for Microalgae
Increasing numbers of studies in the past few decades have demonstrated vertically‐oriented nanoneedles arrays (NNAs) as innovative tools to interrogate and manipulate biological cells, where the needles are inserted into the cells as functional probes for high‐throughput detection and biomolecule delivery. However, majority of these studies use mammalian cells: leaving NNA application to plant cells still in its infancy and largely unexplored. This paper highlights our contributions in exploring the utility of NNAs to microalgae – a diverse group of aquatic, photosynthetic organisms studied intensively as bio‐factories for producing high‐value‐added products such as fuels and pharmaceuticals. Microalgal strain development processes have long suffered from the hard cell wall that surrounds the cell and inhibits delivery of foreign materials into the cell. Conically‐shaped, metallic NNAs were developed with template synthesis that successfully penetrate through the cell wall barrier and achieve material injection – using the widely studied model microalga, Chlamydomonas reinhardtii. Earlier works from mammalian cells are introduced and discussed to clarify the framework established in this field, while recent studies of both mammalian and microalgal cells are also referenced to examine the trends, challenges, and future perspectives of NNA application to microalgae.
- 2 November 2018
- Published by Wiley in The Chemical Record
- Vol. 19 (5) , 859-872
Template‐Synthesized Vertical Needle Array as Injection Platform for Microalgae
Increasing numbers of studies in the past few decades have demonstrated vertically‐oriented nanoneedles arrays (NNAs) as innovative tools to interrogate and manipulate biological cells, where the needles are inserted into the cells as functional probes for high‐throughput detection and biomolecule delivery. However, majority of these studies use mammalian cells: leaving NNA application to plant cells still in its infancy and largely unexplored. This paper highlights our contributions in exploring the utility of NNAs to microalgae – a diverse group of aquatic, photosynthetic organisms studied intensively as bio‐factories for producing high‐value‐added products such as fuels and pharmaceuticals. Microalgal strain development processes have long suffered from the hard cell wall that surrounds the cell and inhibits delivery of foreign materials into the cell. Conically‐shaped, metallic NNAs were developed with template synthesis that successfully penetrate through the cell wall barrier and achieve material injection – using the widely studied model microalga, Chlamydomonas reinhardtii. Earlier works from mammalian cells are introduced and discussed to clarify the framework established in this field, while recent studies of both mammalian and microalgal cells are also referenced to examine the trends, challenges, and future perspectives of NNA application to microalgae.
- 10 April 2018
- Published by IOP Publishing in Nanotechnology
- Vol. 29 (23) , 235704
Ultrathin nanoporous membranes for insulator-based dielectrophoresis
Insulator-based dielectrophoresis (iDEP) is a simple, scalable mechanism that can be used for directly manipulating particle trajectories in pore-based filtration and separation processes. However, iDEP manipulation of nanoparticles presents unique challenges as the dielectrophoretic force ( F ⃗ D E P ) exerted on the nanoparticles can easily be overshadowed by opposing kinetic forces. In this study, a molecularly thin, SiN-based nanoporous membrane (NPN) is explored as a breakthrough technology that enhances F ⃗ D E P . By numerically assessing the gradient of the electric field square ( ∇ ∣ E ⃗ ∣ 2 ) —a common measure for F ⃗ D E P magnitude—it was found that the unique geometrical features of NPN (pore tapering, sharp pore corner and ultrathin thickness) act in favor of intensifying the overall ∇ ∣ E ⃗ ∣ 2 . A comparative study indicated that ∇ ∣ E ⃗ ∣ 2 generated in NPN are four orders of magnitude larger than track-etched polycarbonate membranes with comparable pore size. The stronger ∇ ∣ E ⃗ ∣ 2 suggests that iDEP can be conducted under lower voltage bias with NPN: reducing joule heating concerns and enabling solutions to have higher ionic strength. Enabling higher ionic strength solutions may also extend the opportunities of iDEP applications under physiologically relevant conditions. This study also highlights the effects of ∇ ∣ E ⃗ ∣ 2 induced by the ion accumulation along charged surfaces (electric-double layer (EDL)). EDL-based ∇ ∣ E ⃗ ∣ 2 exists along the entire charged surface, including locations where geometry-based iDEP is negligible. The high surface-to-volume ratio of NPN offers a unique platform for exploiting such EDL-based DEP systems. The EDL-based ∇ ∣ E ⃗ ∣ 2 was also found to offset the geometry-based ∇ ∣ E ⃗ ∣ 2 , but this effect was easily circumvented by reducing the EDL thickness (e.g. increasing the ionic strength from 0.1 to 100 mM). The results from this study imply the potential application of iDEP as a direct, in-operando antifouling mechanism for ultrafiltration technology, and also as an active tuning mechanism to control the cut-off size limit for continuous selectivity of nanomembrane-based separations.
- 10 April 2018
- Published by IOP Publishing in Nanotechnology
- Vol. 29 (23) , 235704
Ultrathin nanoporous membranes for insulator-based dielectrophoresis
Insulator-based dielectrophoresis (iDEP) is a simple, scalable mechanism that can be used for directly manipulating particle trajectories in pore-based filtration and separation processes. However, iDEP manipulation of nanoparticles presents unique challenges as the dielectrophoretic force ( F ⃗ D E P ) exerted on the nanoparticles can easily be overshadowed by opposing kinetic forces. In this study, a molecularly thin, SiN-based nanoporous membrane (NPN) is explored as a breakthrough technology that enhances F ⃗ D E P . By numerically assessing the gradient of the electric field square ( ∇ ∣ E ⃗ ∣ 2 ) —a common measure for F ⃗ D E P magnitude—it was found that the unique geometrical features of NPN (pore tapering, sharp pore corner and ultrathin thickness) act in favor of intensifying the overall ∇ ∣ E ⃗ ∣ 2 . A comparative study indicated that ∇ ∣ E ⃗ ∣ 2 generated in NPN are four orders of magnitude larger than track-etched polycarbonate membranes with comparable pore size. The stronger ∇ ∣ E ⃗ ∣ 2 suggests that iDEP can be conducted under lower voltage bias with NPN: reducing joule heating concerns and enabling solutions to have higher ionic strength. Enabling higher ionic strength solutions may also extend the opportunities of iDEP applications under physiologically relevant conditions. This study also highlights the effects of ∇ ∣ E ⃗ ∣ 2 induced by the ion accumulation along charged surfaces (electric-double layer (EDL)). EDL-based ∇ ∣ E ⃗ ∣ 2 exists along the entire charged surface, including locations where geometry-based iDEP is negligible. The high surface-to-volume ratio of NPN offers a unique platform for exploiting such EDL-based DEP systems. The EDL-based ∇ ∣ E ⃗ ∣ 2 was also found to offset the geometry-based ∇ ∣ E ⃗ ∣ 2 , but this effect was easily circumvented by reducing the EDL thickness (e.g. increasing the ionic strength from 0.1 to 100 mM). The results from this study imply the potential application of iDEP as a direct, in-operando antifouling mechanism for ultrafiltration technology, and also as an active tuning mechanism to control the cut-off size limit for continuous selectivity of nanomembrane-based separations.
- 23 May 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (22) , 19354
Correction to “Fabrication of Tapered Microtube Arrays and Their Application as a Microalgal Injection Platform”
- 23 May 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (22) , 19354
Correction to “Fabrication of Tapered Microtube Arrays and Their Application as a Microalgal Injection Platform”
- 10 May 2017
- Published by Wiley in Electrophoresis
- Vol. 38 (20) , 2587-2591
Electrokinetically controlled fluid injection into unicellular microalgae
Electrokinetically controlled microinjection is reported as an effective transport mechanism for microinjection into the wild‐type strain of the widely studied model microalga Chlamydomonas reinhardtii. A microinjection system using glass capillary pipettes was developed to capture and impale the motile cells. To apply an electric field and induce electrokinetic flow (e.g., electrophoresis and electroosmosis), an electrode was inserted directly into the solution inside the impaling injection pipette and another electrode was inserted into the external cell media. The viability of the impaled cells was confirmed for more than an hour under 0.01 V using the fluorescein diacetate/propidium iodide dual fluorescent dye based assay. The viability was also found to increase almost logarithmically with decreasing voltage and to depend strongly on the solution within the injection pipette. Successful electrokinetic microinjection into cells was confirmed by both an increase in cell volume under an applied voltage and electric field dependent delivery of fluorescent fluorescein molecules into an impaled cell. Our study offers novel opportunities for quantitative delivery of biomolecules into microalgae and advancing the research and development of these organisms as biosynthetic factories.
- 10 May 2017
- Published by Wiley in Electrophoresis
- Vol. 38 (20) , 2587-2591
Electrokinetically controlled fluid injection into unicellular microalgae
Electrokinetically controlled microinjection is reported as an effective transport mechanism for microinjection into the wild‐type strain of the widely studied model microalga Chlamydomonas reinhardtii. A microinjection system using glass capillary pipettes was developed to capture and impale the motile cells. To apply an electric field and induce electrokinetic flow (e.g., electrophoresis and electroosmosis), an electrode was inserted directly into the solution inside the impaling injection pipette and another electrode was inserted into the external cell media. The viability of the impaled cells was confirmed for more than an hour under 0.01 V using the fluorescein diacetate/propidium iodide dual fluorescent dye based assay. The viability was also found to increase almost logarithmically with decreasing voltage and to depend strongly on the solution within the injection pipette. Successful electrokinetic microinjection into cells was confirmed by both an increase in cell volume under an applied voltage and electric field dependent delivery of fluorescent fluorescein molecules into an impaled cell. Our study offers novel opportunities for quantitative delivery of biomolecules into microalgae and advancing the research and development of these organisms as biosynthetic factories.
- 8 December 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (50) , 34198-34208
Fabrication of Tapered Microtube Arrays and Their Application as a Microalgal Injection Platform
A template-synthesis method that enables fabrication of tapered microtube arrays is reported. Track-etched poly(ethylene terephthalate) membranes are used as the template, with closed-tipped conical pores having length and the base diameter of 6.27 ± 0.28 μm and 1.21 ± 0.05 μm, respectively. A conductive layer of Pt is deposited by atomic layer deposition (ALD) to enable the successive electrodeposition of Ni. By decreasing the Pt precursor pulse duration from 10 s to 1 s during the ALD step, the heights of the microtubes are controlled from the maximal full length (~6 μm) to only a fraction (1-2 μm) of the template pore. Using a pulsed-current electrodeposition (PCD) method, a smooth and uniform Ni deposit is achieved with a thickness that can be controlled as a function of the PCD cycle. The microtubes’ lumen is confirmed to stay open even after 2000 cycles of Ni PCD. A potential application of the prepared array as a microinjection platform is demonstrated via successful injection of 10 nm-sized CdZnS/ZnS core/shell quantum dots into Chlamydomonas reinhardtii microalgae cells with intact cell walls. The direct delivery method demonstrated in this paper offers novel opportunities for extending the growing interest in array-based microinjection platform to microalgal systems.
- 8 December 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (50) , 34198-34208
Fabrication of Tapered Microtube Arrays and Their Application as a Microalgal Injection Platform
A template-synthesis method that enables fabrication of tapered microtube arrays is reported. Track-etched poly(ethylene terephthalate) membranes are used as the template, with closed-tipped conical pores having length and the base diameter of 6.27 ± 0.28 μm and 1.21 ± 0.05 μm, respectively. A conductive layer of Pt is deposited by atomic layer deposition (ALD) to enable the successive electrodeposition of Ni. By decreasing the Pt precursor pulse duration from 10 s to 1 s during the ALD step, the heights of the microtubes are controlled from the maximal full length (~6 μm) to only a fraction (1-2 μm) of the template pore. Using a pulsed-current electrodeposition (PCD) method, a smooth and uniform Ni deposit is achieved with a thickness that can be controlled as a function of the PCD cycle. The microtubes’ lumen is confirmed to stay open even after 2000 cycles of Ni PCD. A potential application of the prepared array as a microinjection platform is demonstrated via successful injection of 10 nm-sized CdZnS/ZnS core/shell quantum dots into Chlamydomonas reinhardtii microalgae cells with intact cell walls. The direct delivery method demonstrated in this paper offers novel opportunities for extending the growing interest in array-based microinjection platform to microalgal systems.
- 8 August 2016
- Published by Springer Nature in JOM
- Vol. 68 (10) , 2646-2652
Competitive Current Modes for Tunable Ni-Sn Electrodeposition and Their Lithiation/Delithiation Properties
- 8 August 2016
- Published by Springer Nature in JOM
- Vol. 68 (10) , 2646-2652
Competitive Current Modes for Tunable Ni-Sn Electrodeposition and Their Lithiation/Delithiation Properties
- 1 January 2016
- Published by Elsevier in Bioresource Technology
- Vol. 200, 914-920
Sedimentation-induced detachment of magnetite nanoparticles from microalgal flocs
- 1 January 2016
- Published by Elsevier in Bioresource Technology
- Vol. 200, 914-920
Sedimentation-induced detachment of magnetite nanoparticles from microalgal flocs
- 15 April 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (17) , 7256-7263
A magnetically tuneable piezoresistive sensor for direct, in situ strain measurements in Li-ion batteries
This paper demonstrates the first example of using generic Li-ion battery components (nickel, carboxymethylcellulose and styrene–butadiene rubber) to prepare piezoresistive materials (PRMs) which detect the strain of lithiating Sn in operando. The PRM was prepared by mixing the three components and molding it into a desired shape. Three different types of Ni microparticle arrangement strategies were investigated to study their effects on the piezoresistive performance: an alignment parallel to or perpendicular to the direction of strain, and no alignment (control and random dispersion). The alignment was directed by an external magnetic field during sample preparation and confirmed using cross-sectional SEM images. Significant differences were found between the different alignments, with the parallel alignment resulting in the lowest percolation threshold of 4 vol% Ni and perpendicular alignment the highest of 11 vol% Ni. For a fixed fraction of Ni microparticles at 4 vol%, the difference in alignment resulted in a difference in the gauge factor by three orders of magnitude. The stress–strain curve of the prepared PRMs showed a typical response seen for porous structures, which was consistent with the SEM images. The PRM samples are compatible with the low operating potential and the organic Li-ion electrolyte, and its porous structure allows electrolyte infusion that ensures the ionic conductivity of the material. Lithiation of Sn was successfully detected as a change in resistance using a parallelly aligned PRM with no additional treatment. The method described here offers significant merits over conventional approaches: the ability to directly monitor the strain without complex modelling, the simple low cost setup that does not require specialized equipment, and the ability to easily control the PRM performance by magnetically directed assembly.
- 15 April 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (17) , 7256-7263
A magnetically tuneable piezoresistive sensor for direct, in situ strain measurements in Li-ion batteries
This paper demonstrates the first example of using generic Li-ion battery components (nickel, carboxymethylcellulose and styrene–butadiene rubber) to prepare piezoresistive materials (PRMs) which detect the strain of lithiating Sn in operando. The PRM was prepared by mixing the three components and molding it into a desired shape. Three different types of Ni microparticle arrangement strategies were investigated to study their effects on the piezoresistive performance: an alignment parallel to or perpendicular to the direction of strain, and no alignment (control and random dispersion). The alignment was directed by an external magnetic field during sample preparation and confirmed using cross-sectional SEM images. Significant differences were found between the different alignments, with the parallel alignment resulting in the lowest percolation threshold of 4 vol% Ni and perpendicular alignment the highest of 11 vol% Ni. For a fixed fraction of Ni microparticles at 4 vol%, the difference in alignment resulted in a difference in the gauge factor by three orders of magnitude. The stress–strain curve of the prepared PRMs showed a typical response seen for porous structures, which was consistent with the SEM images. The PRM samples are compatible with the low operating potential and the organic Li-ion electrolyte, and its porous structure allows electrolyte infusion that ensures the ionic conductivity of the material. Lithiation of Sn was successfully detected as a change in resistance using a parallelly aligned PRM with no additional treatment. The method described here offers significant merits over conventional approaches: the ability to directly monitor the strain without complex modelling, the simple low cost setup that does not require specialized equipment, and the ability to easily control the PRM performance by magnetically directed assembly.
- 1 February 2015
- Published by Elsevier in Materials Letters
- Vol. 141, 76-78
Template-synthesized gold microneedle arrays for gene delivery to the Chlamydomonas reinhardtii chloroplast
- 1 February 2015
- Published by Elsevier in Materials Letters
- Vol. 141, 76-78
Template-synthesized gold microneedle arrays for gene delivery to the Chlamydomonas reinhardtii chloroplast
- 1 October 2014
- Published by Elsevier in Materials Letters
- Vol. 133, 171-174
Polymeric hydrogel thin film synthesis via diffusion through a porous membrane
- 1 October 2014
- Published by Elsevier in Materials Letters
- Vol. 133, 171-174
Polymeric hydrogel thin film synthesis via diffusion through a porous membrane