Kang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kang Li has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Lin Su
School of Energy and Power Engineering University of Shanghai for Science and Technology Shanghai China
7 shared publications- Yidong Fang
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China
7 shared publications - Lin Su
School of Energy and Power Engineering; University of Shanghai for Science and Technology; Shanghai China
5 shared publications Yidong Fang
School of Energy and Power Engineering University of Shanghai for Science and Technology Shanghai China
5 shared publicationsHua Zhang
Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering School of Energy and Power Engineering University of Shanghai for Science and Technology Shanghai China
4 shared publications- Jun Yu
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China
3 shared publications
Latest Publications
- 22 July 2026
- Published by Wiley in Energy Technology
- Vol. 14 (7) , e70592
The Heat Transfer Enhancement Mechanism of Paraffin by Graphene Nanoparticles for Varying Heat Flux Density
Phase‐change thermal storage technology can effectively address the issues of uneven spatial and temporal distribution of solar energy and low energy density. However, the low thermal conductivity of phase‐change materials (PCMs) limits their application range. Adding high thermal conductivity materials is an important approach to enhance the thermal conductivity of PCMs. In this paper, different mass fractions (0.5%, 1.0%, 1.5%, and 2.0%) of graphene/paraffin composite PCMs (nanoparticles [NPs]) were prepared using the melt blending method. The effects of heat flux density (5.0, 10.0, and 15.0 kW/m 2 ) on the melting heat transfer enhancement mechanism and thermal storage characteristics of the composite PCMs were deeply investigated. The research results show that increasing heat flux density can enhance natural convection during the melting process of the composite PCMs and significantly shorten the melting time. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , the melting time is reduced by 158.9%. However, the addition of graphene inhibits natural convection, and the greater the mass fraction of graphene, the more pronounced the inhibition. The enhancement of natural convection by heat flux density is not sufficient to offset the inhibition of natural convection heat transfer by graphene. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , compared to 0.5% NP, the Rayleigh number and Nusselt number increase by 44.9% and 23.0%, respectively, for 2.0% NP. In addition, heat flux density can significantly enhance thermal storage performance. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , the thermal storage capacity increases by 39.1%, 43.2%, 43.3%, and 44.2% for 0.5% NP, 1.0% NP, 1.5% NP, and 2.0% NP, respectively. The 1.5% NP composite PCM exhibits the best thermal storage characteristics.
- 22 July 2026
- Published by Wiley in Energy Technology
- Vol. 14 (7) , e70592
The Heat Transfer Enhancement Mechanism of Paraffin by Graphene Nanoparticles for Varying Heat Flux Density
Phase‐change thermal storage technology can effectively address the issues of uneven spatial and temporal distribution of solar energy and low energy density. However, the low thermal conductivity of phase‐change materials (PCMs) limits their application range. Adding high thermal conductivity materials is an important approach to enhance the thermal conductivity of PCMs. In this paper, different mass fractions (0.5%, 1.0%, 1.5%, and 2.0%) of graphene/paraffin composite PCMs (nanoparticles [NPs]) were prepared using the melt blending method. The effects of heat flux density (5.0, 10.0, and 15.0 kW/m 2 ) on the melting heat transfer enhancement mechanism and thermal storage characteristics of the composite PCMs were deeply investigated. The research results show that increasing heat flux density can enhance natural convection during the melting process of the composite PCMs and significantly shorten the melting time. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , the melting time is reduced by 158.9%. However, the addition of graphene inhibits natural convection, and the greater the mass fraction of graphene, the more pronounced the inhibition. The enhancement of natural convection by heat flux density is not sufficient to offset the inhibition of natural convection heat transfer by graphene. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , compared to 0.5% NP, the Rayleigh number and Nusselt number increase by 44.9% and 23.0%, respectively, for 2.0% NP. In addition, heat flux density can significantly enhance thermal storage performance. When the heat flux density increases from 5.0 to 15.0 kW/m 2 , the thermal storage capacity increases by 39.1%, 43.2%, 43.3%, and 44.2% for 0.5% NP, 1.0% NP, 1.5% NP, and 2.0% NP, respectively. The 1.5% NP composite PCM exhibits the best thermal storage characteristics.
- 1 January 2026
- Published by Tech Science Press in Frontiers in Heat and Mass Transfer
- p. 1-10
Directional Thermal Conductivity and Heat Generation in a Commercial 314 Ah Lithium Iron Phosphate Prismatic Cell
Large-format lithium iron phosphate (LFP) prismatic cells are widely used in stationary energy storage, but direction-resolved thermal properties and time-resolved heat generation of the 314 Ah format are scarcely reported. Steady-state tests give the conductivity of a 314 Ah cell as 4.11 W m−1 K−1 through the thickness and 21.04 and 19.82 W m−1 K−1 in the width and height directions (ratios of about 5.1 and 4.8; expanded uncertainties about 26, 10 and 9.5%, k = 2, from thermocouple tolerances). A verified three-dimensional orthotropic model built on them reconstructs the heat generation rate from the mean surface temperature measured during 0.5C (157 A) charge and discharge. With the calibrated loss coefficient the mean heat rate is about 22 W on charge and 23 W on discharge (95% interval about 20 to 25 W); the storage-only lower bounds are 14.8 W and 16.3 W, and the loss coefficient is the dominant uncertainty. The discharge rate falls to about 16 W mid-step and then climbs to about 41 W near cut-off (41 ± 2 W at 6600 s, the end of the interpreted interval), which an order-of-magnitude argument attributes mainly to irreversible heat. The model gives a surface-averaging bias of about 1% under natural convection, a peak internal rise of 0.07 to 0.58 K W−1 depending on the cooled face (interface conductances of 500 to 2000 W m−2 K−1), and a 23 to 59% error in that rise for an isotropic model. Isothermal calorimetry would further narrow the loss-coefficient uncertainty.
- 1 January 2026
- Published by Tech Science Press in Frontiers in Heat and Mass Transfer
- p. 1-10
Directional Thermal Conductivity and Heat Generation in a Commercial 314 Ah Lithium Iron Phosphate Prismatic Cell
Large-format lithium iron phosphate (LFP) prismatic cells are widely used in stationary energy storage, but direction-resolved thermal properties and time-resolved heat generation of the 314 Ah format are scarcely reported. Steady-state tests give the conductivity of a 314 Ah cell as 4.11 W m−1 K−1 through the thickness and 21.04 and 19.82 W m−1 K−1 in the width and height directions (ratios of about 5.1 and 4.8; expanded uncertainties about 26, 10 and 9.5%, k = 2, from thermocouple tolerances). A verified three-dimensional orthotropic model built on them reconstructs the heat generation rate from the mean surface temperature measured during 0.5C (157 A) charge and discharge. With the calibrated loss coefficient the mean heat rate is about 22 W on charge and 23 W on discharge (95% interval about 20 to 25 W); the storage-only lower bounds are 14.8 W and 16.3 W, and the loss coefficient is the dominant uncertainty. The discharge rate falls to about 16 W mid-step and then climbs to about 41 W near cut-off (41 ± 2 W at 6600 s, the end of the interpreted interval), which an order-of-magnitude argument attributes mainly to irreversible heat. The model gives a surface-averaging bias of about 1% under natural convection, a peak internal rise of 0.07 to 0.58 K W−1 depending on the cooled face (interface conductances of 500 to 2000 W m−2 K−1), and a 23 to 59% error in that rise for an isotropic model. Isothermal calorimetry would further narrow the loss-coefficient uncertainty.
- Open Access
- 1 January 2026
- Published by Tech Science Press in Frontiers in Heat and Mass Transfer
- Vol. 24 (2) , 1-10
Experimental Investigation on Heating Performance and Frosting Behavior of an Integrated R290 Secondary Loop Heat Pump
Energy storage batteries require strict thermal management due to temperature sensitivity, operating optimally within a narrow thermal range. Simultaneously, control rooms demand stable and comfortable ambient conditions for staff staying long-term. Conventional temperature control systems typically employ isolated solutions, resulting in functional fragmentation and inefficient resource utilization. To address these challenges, this study proposes and implements an integrated R290 secondary loop heat pump air-conditioning system designed to simultaneously manage the thermal environments of both energy storage batteries and control rooms. By adopting a secondary-loop coupling architecture, all thermal regulation is achieved indirectly via indirect heat transfer with a circulating ethylene glycol-based coolant, eliminating the risk of direct refrigerant (R290) exposure in occupied spaces and enhancing safety. The system supports multiple operational modes, enabling flexible and efficient dual-zone climate control. The heating performance—evaluated in terms of heat exchange capacity and coefficient of performance (COP)—is analyzed under varying ambient temperatures and compressor speeds. Additionally, the frosting behavior of the outdoor heat exchanger and its impact on heat transfer and system performance are examined. Results showed heat output ranged from 3.01 to 4.27 kW, and COP varied between 1.9 and 2.8. Ambient temperature (more dominant than compressor speed) and speed both affected performance: higher speed/warmer temperatures improved heat transfer efficiency; low temperatures accelerated frosting (e.g., −5°C reduced heat output by 19.67% and COP by 31.13%, vs. 13.72% and 12.40% at 5°C). These findings provide critical insights for optimizing heat transfer design and operation of integrated thermal management systems in energy storage facilities.
- 1 January 2026
- Published by Tech Science Press in Frontiers in Heat and Mass Transfer
- Vol. 24 (2) , 1-10
Open AccessExperimental Investigation on Heating Performance and Frosting Behavior of an Integrated R290 Secondary Loop Heat Pump
Energy storage batteries require strict thermal management due to temperature sensitivity, operating optimally within a narrow thermal range. Simultaneously, control rooms demand stable and comfortable ambient conditions for staff staying long-term. Conventional temperature control systems typically employ isolated solutions, resulting in functional fragmentation and inefficient resource utilization. To address these challenges, this study proposes and implements an integrated R290 secondary loop heat pump air-conditioning system designed to simultaneously manage the thermal environments of both energy storage batteries and control rooms. By adopting a secondary-loop coupling architecture, all thermal regulation is achieved indirectly via indirect heat transfer with a circulating ethylene glycol-based coolant, eliminating the risk of direct refrigerant (R290) exposure in occupied spaces and enhancing safety. The system supports multiple operational modes, enabling flexible and efficient dual-zone climate control. The heating performance—evaluated in terms of heat exchange capacity and coefficient of performance (COP)—is analyzed under varying ambient temperatures and compressor speeds. Additionally, the frosting behavior of the outdoor heat exchanger and its impact on heat transfer and system performance are examined. Results showed heat output ranged from 3.01 to 4.27 kW, and COP varied between 1.9 and 2.8. Ambient temperature (more dominant than compressor speed) and speed both affected performance: higher speed/warmer temperatures improved heat transfer efficiency; low temperatures accelerated frosting (e.g., −5°C reduced heat output by 19.67% and COP by 31.13%, vs. 13.72% and 12.40% at 5°C). These findings provide critical insights for optimizing heat transfer design and operation of integrated thermal management systems in energy storage facilities.
- 30 April 2025
- Published by Bentham Science Publishers Ltd. in Recent Patents on Mechanical Engineering
- Vol. 18, 1-11
Numerical Simulation Study of Heat Transfer Characteristics of Low Melting Point Metal Flow in Different Tubes
Background: The superior heat transfer properties, tunability, and flow characteristics of liquid metals, combined with the increasing number of patents in microchannel and coolant technologies, underscore their significance in scientific and industrial applications. Objective: In this study, numerical simulations are employed to investigate the impact of pipe cross-sectional shapes, Reynolds numbers, and heat flux densities on the heat transfer properties of the alloy. Methods: This paper conducts a numerical simulation study on indium-tin-bismuth alloys to investigate their flow and heat transfer characteristics in tubes of various cross-sectional shapes (circular, elliptical, flat, square, and triangular) under equivalent diameter conditions. The study aims to identify the optimal tube type and elucidate the underlying flow and heat transfer mechanisms of the alloy, thereby revealing its properties and potential applications. Results: The study yielded the following conclusions: 1) The liquid metal indium-tin-bismuth shows similar distributions of temperature, pressure, and velocity in circular, square, oval, and flat tubes. Temperature rises with increasing heat transfer area, while pressure decreases due to frictional resistance. 2) Increasing the flow rate and wall heat flux density enhances the heat transfer coefficient between the liquid metal indium-tin-bismuth and the tube wall, thereby improving overall heat transfer performance. 3) The indium-tin-bismuth alloy, as a novel heat-dissipating material, validates the feasibility of heat-dissipation design through numerical analysis. Conclusion: This paper employs the finite volume numerical method to analyze the flow rate, temperature, pressure, and heat transfer coefficient of liquid metal indium-tin-bismuth within tubes. The results provide a reference for the application of indium-tin-bismuth alloys in heat transfer.
- 30 April 2025
- Published by Bentham Science Publishers Ltd. in Recent Patents on Mechanical Engineering
- Vol. 18, 1-11
Numerical Simulation Study of Heat Transfer Characteristics of Low Melting Point Metal Flow in Different Tubes
Background: The superior heat transfer properties, tunability, and flow characteristics of liquid metals, combined with the increasing number of patents in microchannel and coolant technologies, underscore their significance in scientific and industrial applications. Objective: In this study, numerical simulations are employed to investigate the impact of pipe cross-sectional shapes, Reynolds numbers, and heat flux densities on the heat transfer properties of the alloy. Methods: This paper conducts a numerical simulation study on indium-tin-bismuth alloys to investigate their flow and heat transfer characteristics in tubes of various cross-sectional shapes (circular, elliptical, flat, square, and triangular) under equivalent diameter conditions. The study aims to identify the optimal tube type and elucidate the underlying flow and heat transfer mechanisms of the alloy, thereby revealing its properties and potential applications. Results: The study yielded the following conclusions: 1) The liquid metal indium-tin-bismuth shows similar distributions of temperature, pressure, and velocity in circular, square, oval, and flat tubes. Temperature rises with increasing heat transfer area, while pressure decreases due to frictional resistance. 2) Increasing the flow rate and wall heat flux density enhances the heat transfer coefficient between the liquid metal indium-tin-bismuth and the tube wall, thereby improving overall heat transfer performance. 3) The indium-tin-bismuth alloy, as a novel heat-dissipating material, validates the feasibility of heat-dissipation design through numerical analysis. Conclusion: This paper employs the finite volume numerical method to analyze the flow rate, temperature, pressure, and heat transfer coefficient of liquid metal indium-tin-bismuth within tubes. The results provide a reference for the application of indium-tin-bismuth alloys in heat transfer.
- Open Access
- 12 December 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1515336
Editorial: Advancements in thermal safety and management technologies for energy storage systems
In recent years, with the rapid development of renewable energy, energy storage systems have played an increasingly important role in power systems. Energy storage technology is a key technology for utilizing new clean energy sources. At present, energy storage technology is mainly composed of chemical energy storage, electrochemical energy storage, thermal mass energy storage, and energy storage system integration and safety (as shown in Figure 1), all of which pose long-term challenges related to thermal management and thermal security. As energy storage technology progresses, its safety, particularly thermal safety, has garnered widespread attention. Effectively managing heat in energy storage systems to ensure their safe operation has become a current hot topic in research and application. Based on this, this issue discusses the development of new technologies in the field of energy storage, thermal safety and management, and includes a total of 6 articles. Driven by environmental emission standards and the energy crisis, hydrogen has become a zero-carbon, clean energy source [1]. In recent years, fuel cell vehicles (FCVs) have become a significant focus for the future development of the automotive industry, with hydrogen refueling stations playing a crucial role in integrating hydrogen technology into daily transportation [2]. Despite these advancements, the low density of hydrogen leads to rapid dispersion during leakages, posing substantial safety risks such as fires and explosions during storage, transport, and use. These issues hinder the global adoption of hydrogen energy applications and the development of related infrastructure [3]. Although extensive research has focused on the dispersion characteristics of hydrogen leaks in various environments, most studies concentrate on open spaces. There is a noticeable lack of reliable data on hydrogen leak dispersion in enclosed spaces, such as ceilings. Moreover, while previous studies on free jets have identified specific patterns, research on enclosed spaces generally provides a broad overview of spatial distribution patterns based on parameters without detailed empirical formulas. Therefore, this study develops an experimental system to investigate hydrogen leak dispersion in enclosed spaces, summarizing the concentration distribution patterns of hydrogen leaks in ceiling-enclosed spaces, providing reference data for the prevention and control of future hydrogen refueling station infrastructure. At the same time, this issue explores: advanced thermal management technologies, innovative materials with superior thermal properties, design solutions for optimized thermal management, and recent advances in cooling technology. In addition, this issue discusses safety measures to mitigate risks and strategies for responding to thermal runaway events, outlines challenges and solutions in thermal safety and management in energy storage systems and encourages further research and development in this critical area. In addition, as a core component of various electronic devices and electric vehicles, the safety and management of batteries are particularly important. With the rapid development of battery technology, especially the widespread application of lithium-ion batteries, many potential safety hazards have emerged, such as overheating, short circuits, and leaks. These problems can not only lead to damage to equipment, but in more serious cases, they can also cause fires and explosions, which can endanger personal safety. Therefore, studying the safety of batteries is not only the key to improving product reliability, but also an important measure to protect consumers and the environment. In addition, a scientific and reasonable battery management system (BMS) can monitor the operating status of the battery in real time, optimize the charging and discharging process, prolong its service life, and reduce the risk of accidents. Therefore, it is of great significance to promote the research of battery safety and management to achieve sustainable development and promote the green technology revolution. Ultimately, our goal is to contribute to the development of sustainable and safe energy storage technologies. Furthermore, as energy storage technology continuously evolves, the traditional energy education model can no longer meet the industry's developmental needs. Currently, the energy sector urgently requires talents with comprehensive qualifications, necessitating corresponding reforms and innovations in the education system. Specifically, educational reforms should focus on the following aspects:1) Curriculum Update: Revise course content to reflect trends in energy storage technology, focusing on thermal management, materials science, and systems engineering, while integrating practical case studies to enhance hands-on skills.2) Interdisciplinary Collaboration: Promote cooperation between engineering, physics, chemistry, and computer science faculty and students to form multidisciplinary teams that boost innovation in energy storage systems.3) Practical Experience: Strengthen partnerships with enterprises to create internship and research opportunities, enabling students to engage with real energy storage projects and stay updated on industry advancements, enhancing their competitiveness.4) Innovation and Entrepreneurship: Foster innovation and entrepreneurship education to nurture students' creative thinking and practical skills, encouraging involvement in the research and application of energy storage technologies.Through these reforms, these talents will play an important role in the design, research and development, management and other aspects of energy storage systems to promote the sustainable development of the industry.In the future, energy storage systems will evolve alongside advancements in thermal management technologies. The combined progress in materials science, power electronics, and thermal management will enhance...
- 12 December 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1515336
Open AccessEditorial: Advancements in thermal safety and management technologies for energy storage systems
In recent years, with the rapid development of renewable energy, energy storage systems have played an increasingly important role in power systems. Energy storage technology is a key technology for utilizing new clean energy sources. At present, energy storage technology is mainly composed of chemical energy storage, electrochemical energy storage, thermal mass energy storage, and energy storage system integration and safety (as shown in Figure 1), all of which pose long-term challenges related to thermal management and thermal security. As energy storage technology progresses, its safety, particularly thermal safety, has garnered widespread attention. Effectively managing heat in energy storage systems to ensure their safe operation has become a current hot topic in research and application. Based on this, this issue discusses the development of new technologies in the field of energy storage, thermal safety and management, and includes a total of 6 articles. Driven by environmental emission standards and the energy crisis, hydrogen has become a zero-carbon, clean energy source [1]. In recent years, fuel cell vehicles (FCVs) have become a significant focus for the future development of the automotive industry, with hydrogen refueling stations playing a crucial role in integrating hydrogen technology into daily transportation [2]. Despite these advancements, the low density of hydrogen leads to rapid dispersion during leakages, posing substantial safety risks such as fires and explosions during storage, transport, and use. These issues hinder the global adoption of hydrogen energy applications and the development of related infrastructure [3]. Although extensive research has focused on the dispersion characteristics of hydrogen leaks in various environments, most studies concentrate on open spaces. There is a noticeable lack of reliable data on hydrogen leak dispersion in enclosed spaces, such as ceilings. Moreover, while previous studies on free jets have identified specific patterns, research on enclosed spaces generally provides a broad overview of spatial distribution patterns based on parameters without detailed empirical formulas. Therefore, this study develops an experimental system to investigate hydrogen leak dispersion in enclosed spaces, summarizing the concentration distribution patterns of hydrogen leaks in ceiling-enclosed spaces, providing reference data for the prevention and control of future hydrogen refueling station infrastructure. At the same time, this issue explores: advanced thermal management technologies, innovative materials with superior thermal properties, design solutions for optimized thermal management, and recent advances in cooling technology. In addition, this issue discusses safety measures to mitigate risks and strategies for responding to thermal runaway events, outlines challenges and solutions in thermal safety and management in energy storage systems and encourages further research and development in this critical area. In addition, as a core component of various electronic devices and electric vehicles, the safety and management of batteries are particularly important. With the rapid development of battery technology, especially the widespread application of lithium-ion batteries, many potential safety hazards have emerged, such as overheating, short circuits, and leaks. These problems can not only lead to damage to equipment, but in more serious cases, they can also cause fires and explosions, which can endanger personal safety. Therefore, studying the safety of batteries is not only the key to improving product reliability, but also an important measure to protect consumers and the environment. In addition, a scientific and reasonable battery management system (BMS) can monitor the operating status of the battery in real time, optimize the charging and discharging process, prolong its service life, and reduce the risk of accidents. Therefore, it is of great significance to promote the research of battery safety and management to achieve sustainable development and promote the green technology revolution. Ultimately, our goal is to contribute to the development of sustainable and safe energy storage technologies. Furthermore, as energy storage technology continuously evolves, the traditional energy education model can no longer meet the industry's developmental needs. Currently, the energy sector urgently requires talents with comprehensive qualifications, necessitating corresponding reforms and innovations in the education system. Specifically, educational reforms should focus on the following aspects:1) Curriculum Update: Revise course content to reflect trends in energy storage technology, focusing on thermal management, materials science, and systems engineering, while integrating practical case studies to enhance hands-on skills.2) Interdisciplinary Collaboration: Promote cooperation between engineering, physics, chemistry, and computer science faculty and students to form multidisciplinary teams that boost innovation in energy storage systems.3) Practical Experience: Strengthen partnerships with enterprises to create internship and research opportunities, enabling students to engage with real energy storage projects and stay updated on industry advancements, enhancing their competitiveness.4) Innovation and Entrepreneurship: Foster innovation and entrepreneurship education to nurture students' creative thinking and practical skills, encouraging involvement in the research and application of energy storage technologies.Through these reforms, these talents will play an important role in the design, research and development, management and other aspects of energy storage systems to promote the sustainable development of the industry.In the future, energy storage systems will evolve alongside advancements in thermal management technologies. The combined progress in materials science, power electronics, and thermal management will enhance...
- 26 April 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Impact of optimized gas-liquid separator on temperature and frost distribution in electric vehicle heat pump AC
- 26 April 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Impact of optimized gas-liquid separator on temperature and frost distribution in electric vehicle heat pump AC
- 29 July 2022
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (13) , 18294-18311
An investigation on dehumidification and heat transfer characteristics of a minichannel heat exchanger for heat pump system of electric vehicles
- 29 July 2022
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (13) , 18294-18311
An investigation on dehumidification and heat transfer characteristics of a minichannel heat exchanger for heat pump system of electric vehicles
- Open Access
Optimal Control Strategies for Demand Response in Buildings under Penetration of Renewable Energy
The penetration rates of intermittent renewable energies such as wind and solar energy have been increasing in power grids, often leading to a massive peak-to-valley difference in the net load demand, known as a “duck curve”. The power demand and supply should remain balanced in real-time, however, traditional power plants generally cannot output a large range of variable loads to balance the demand and supply, resulting in the overgeneration of solar and wind energy in the grid. Meanwhile, the power generation hours of the plant are forced to be curtailed, leading to a decrease in energy efficiency. Building demand response (DR) is considered as a promising technology for the collaborative control of energy supply and demand. Conventionally, building control approaches usually consider the minimization of total energy consumption as the optimization objective function; relatively few control methods have considered the balance of energy supply and demand under high renewable energy penetration. Thus, this paper proposes an innovative DR control approach that considers the energy flexibility of buildings. First, based on an energy flexibility quantification framework, the energy flexibility capacity of a typical office building is quantified; second, according to energy flexibility and a predictive net load demand curve of the grid, two DR control strategies are designed: rule-based and prediction-based DR control strategies. These two proposed control strategies are validated based on scenarios of heating, ventilation, and air conditioning (HVAC) systems with and without an energy storage tank. The results show that 24–55% of the building’s total load can be shifted from the peak load time to the valley load time, and that the duration is over 2 h, owing to the utilization of energy flexibility and the implementation of the proposed DR controls. The findings of this work are beneficial for smoothing the net load demand curve of a grid and improving the ability of a grid to adopt renewable energies.
Open AccessOptimal Control Strategies for Demand Response in Buildings under Penetration of Renewable Energy
The penetration rates of intermittent renewable energies such as wind and solar energy have been increasing in power grids, often leading to a massive peak-to-valley difference in the net load demand, known as a “duck curve”. The power demand and supply should remain balanced in real-time, however, traditional power plants generally cannot output a large range of variable loads to balance the demand and supply, resulting in the overgeneration of solar and wind energy in the grid. Meanwhile, the power generation hours of the plant are forced to be curtailed, leading to a decrease in energy efficiency. Building demand response (DR) is considered as a promising technology for the collaborative control of energy supply and demand. Conventionally, building control approaches usually consider the minimization of total energy consumption as the optimization objective function; relatively few control methods have considered the balance of energy supply and demand under high renewable energy penetration. Thus, this paper proposes an innovative DR control approach that considers the energy flexibility of buildings. First, based on an energy flexibility quantification framework, the energy flexibility capacity of a typical office building is quantified; second, according to energy flexibility and a predictive net load demand curve of the grid, two DR control strategies are designed: rule-based and prediction-based DR control strategies. These two proposed control strategies are validated based on scenarios of heating, ventilation, and air conditioning (HVAC) systems with and without an energy storage tank. The results show that 24–55% of the building’s total load can be shifted from the peak load time to the valley load time, and that the duration is over 2 h, owing to the utilization of energy flexibility and the implementation of the proposed DR controls. The findings of this work are beneficial for smoothing the net load demand curve of a grid and improving the ability of a grid to adopt renewable energies.
- Open Access
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 5130-5140
Investigating the performance optimization of an outdoor condenser–evaporator for an electric vehicle heat pump system
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 5130-5140
Open AccessInvestigating the performance optimization of an outdoor condenser–evaporator for an electric vehicle heat pump system
- 2 March 2021
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 45 (7) , 10912-10923
Design and performance optimization of microchannel condensers for electric vehicles
Conventional air conditioning systems for electric vehicle have insufficient performance. Therefore, the structures on both sides of microchannel condensers must be optimized to improve their thermal hydraulic performance and enhance the COP of the air‐conditioning system in electric vehicles. Through numerical calculations and experiments, the thermal hydraulic performance of microchannel condensers were evaluated to determine the optimal values of the microchannels number, flat‐tube hole aspect ratio, flow passes, and fin pitch. The results obtained using established numerical calculation models have certain reliability with errors within ±5.6%. The results reveal that the heat exchange performance of the microchannel condensers could be enhanced by appropriately reducing the fin pitch at certain frontal air velocities. Additionally, this causes a rapid increase in air flow resistance. When the flat‐tube hole aspect ratio is 1.15 and the number of flat‐tube channels is 10, the microchannel heat exchanger demonstrates optimum thermal hydraulic performance. Experimental results show that the heat exchange capacity of the three‐ and four‐pass microchannel condenser are very close which is 36.5% greater than that of the two‐pass microchannel condenser. Meanwhile, the three‐pass condenser refrigerant flow resistance is 8.3% lower than that of the four‐pass condenser. Therefore, the microchannel condenser with three passes demonstrates the best thermal hydraulic performance.
- 2 March 2021
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 45 (7) , 10912-10923
Design and performance optimization of microchannel condensers for electric vehicles
Conventional air conditioning systems for electric vehicle have insufficient performance. Therefore, the structures on both sides of microchannel condensers must be optimized to improve their thermal hydraulic performance and enhance the COP of the air‐conditioning system in electric vehicles. Through numerical calculations and experiments, the thermal hydraulic performance of microchannel condensers were evaluated to determine the optimal values of the microchannels number, flat‐tube hole aspect ratio, flow passes, and fin pitch. The results obtained using established numerical calculation models have certain reliability with errors within ±5.6%. The results reveal that the heat exchange performance of the microchannel condensers could be enhanced by appropriately reducing the fin pitch at certain frontal air velocities. Additionally, this causes a rapid increase in air flow resistance. When the flat‐tube hole aspect ratio is 1.15 and the number of flat‐tube channels is 10, the microchannel heat exchanger demonstrates optimum thermal hydraulic performance. Experimental results show that the heat exchange capacity of the three‐ and four‐pass microchannel condenser are very close which is 36.5% greater than that of the two‐pass microchannel condenser. Meanwhile, the three‐pass condenser refrigerant flow resistance is 8.3% lower than that of the four‐pass condenser. Therefore, the microchannel condenser with three passes demonstrates the best thermal hydraulic performance.