Luciano Garelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luciano Garelli has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Mario Alberto Storti
Centro de Investigacion de Metodos Computacionales (CIMEC), CONICET-UNL. Santa Fe, Argentina
11 shared publications - Gustavo Rios Rodriguez
Centro de Investigacion de Metodos Computacionales (CIMEC), CONICET-UNL. Santa Fe, Argentina
3 shared publications - Rodrigo R. Paz
Centro Internacional de Métodos Computacionales en Ingeniería (CIMEC), Instituto de Desarrollo Tecnológico para la Industria Química (INTEC), Consejo Nacional de Investigacione ...
3 shared publications - Bartlomiej Melka
Silesian University of Technology
2 shared publications Francisco Pessolani
Tadeo Czerweny S.A., Glvez, Argentina
2 shared publicationsGustavo Ríos Rodriguez
2 shared publications
Latest Publications
- Open Access
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10)
Modelado de la Interacción Fluido-Estructura de un Vehículo de Gran Superficie Lateral Empleando Acoplamientos Unidireccional y Bidireccional
Los vehículos de gran superficie lateral son inherentemente más propensos a verse involucrados en accidentes de tránsito que otros sistemas de transporte terrestres debido a sus características constructivas particulares —principalmente, una extensa área lateral expuesta al viento y un centro de gravedad elevado. La predicción precisa de las cargas aerodinámicas y de la dinámica resultante del vehículo en escenarios operativos relevantes es esencial para estrategias de mitigación sustentadas en análisis numéricos. En este contexto, este estudio presenta una implementación específica para la resolución de problemas de interacción fluido-estructura con acoplamientos unidireccional (one-way) y bidireccional (two-way) para un modelo benchmark de un vehículo de gran superficie lateral —Ground Transportation System (GTS). El código consiste en el uso de un módulo de dinámica vehicular propio escrito en C++ e integrado dentro del software Code Saturne. El modelo propuesto se contrasta con estudios publicados por otros autores, confirmando concordancia entre los resultados.
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10)
Open AccessModelado de la Interacción Fluido-Estructura de un Vehículo de Gran Superficie Lateral Empleando Acoplamientos Unidireccional y Bidireccional
Los vehículos de gran superficie lateral son inherentemente más propensos a verse involucrados en accidentes de tránsito que otros sistemas de transporte terrestres debido a sus características constructivas particulares —principalmente, una extensa área lateral expuesta al viento y un centro de gravedad elevado. La predicción precisa de las cargas aerodinámicas y de la dinámica resultante del vehículo en escenarios operativos relevantes es esencial para estrategias de mitigación sustentadas en análisis numéricos. En este contexto, este estudio presenta una implementación específica para la resolución de problemas de interacción fluido-estructura con acoplamientos unidireccional (one-way) y bidireccional (two-way) para un modelo benchmark de un vehículo de gran superficie lateral —Ground Transportation System (GTS). El código consiste en el uso de un módulo de dinámica vehicular propio escrito en C++ e integrado dentro del software Code Saturne. El modelo propuesto se contrasta con estudios publicados por otros autores, confirmando concordancia entre los resultados.
- Open Access
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10) , 143
Streamlined Boundaries for Fluid-Structure Interaction in Vehicles
Choosing an appropriate computational domain for moving vehicles with strong fluid-structure interaction (FSI) is a challenging task. Typically, the vehicle follows a very long trajectory (compared to its size) in the longitudinal direction, but it can also experience significant lateral displacements, or even changes in direction, due to the fluid's action. If a fixed, earth-bound domain is used, it would need to be excessively large, demanding substantial computational effort. In this article, we propose a strategy to have a computational domain that follows the body, while keeping the lateral boundaries as streamlines so that standard slip boundary conditions can be applied there. Standard Arbitrary Lagrangian-Eulerian (ALE) terms are added to account for the mesh movement. This approach allows for the consideration of very complex vehicle movements with a computational cost roughly similar to that of a standard FSI problem. Note that ALE terms must be included anyway due to the body's movement caused by the FSI. Details of the numerical implementation of the streamlined boundaries are discussed, and several numerical examples are presented
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10) , 143
Open AccessStreamlined Boundaries for Fluid-Structure Interaction in Vehicles
Choosing an appropriate computational domain for moving vehicles with strong fluid-structure interaction (FSI) is a challenging task. Typically, the vehicle follows a very long trajectory (compared to its size) in the longitudinal direction, but it can also experience significant lateral displacements, or even changes in direction, due to the fluid's action. If a fixed, earth-bound domain is used, it would need to be excessively large, demanding substantial computational effort. In this article, we propose a strategy to have a computational domain that follows the body, while keeping the lateral boundaries as streamlines so that standard slip boundary conditions can be applied there. Standard Arbitrary Lagrangian-Eulerian (ALE) terms are added to account for the mesh movement. This approach allows for the consideration of very complex vehicle movements with a computational cost roughly similar to that of a standard FSI problem. Note that ALE terms must be included anyway due to the body's movement caused by the FSI. Details of the numerical implementation of the streamlined boundaries are discussed, and several numerical examples are presented
- Open Access
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10) , 141
Análisis Comparativo de las Estrategia MRF y de Malla Deslizante para la Simulación del Flujo en un Agitador con Turbina Rushton
Una de las principales preocupaciones sobre los reactores agitados es el tiempo de mezclado para una sustancia determinada. Las mediciones experimentales destinadas a caracterizar el desempeño de los agitadores requieren equipos costosos y especializados; por ello, las simulaciones mediante dinámica de fluidos computacional surgen como una alternativa atractiva. Entre las estrategias para abordar el problema, el método de marcos de referencia múltiples (MRF, por sus siglas en inglés) ha ganado popularidad por su sencillez en la generación de la malla y el costo reducido en el cálculo de la solución, comparado con la estrategia de malla móvil. No obstante, las soluciones obtenidas con MRF presentan dependencia en el tamaño de la zona donde se considera la rotación del fluido. En este trabajo se muestra que si bien las simulaciones con MRF proporcionan resultados precisos para índices globales del agitador, el tiempo de mezclado es sobreestimado y el campo de movimiento resulta incorrecto. A tal fin, se comparan resultados obtenidos con esta estrategia, aplicada a un mezclador de referencia equipado con una turbina Rushton, resultados experimentales, y simulaciones numéricas realizadas con malla móvil en OpenFOAM y StarCCM.
- 17 December 2025
- Published by Asociación Argentina De Mecánica Computacional in Resúmenes de Mecánica Computacional
- Vol. 2 (10) , 141
Open AccessAnálisis Comparativo de las Estrategia MRF y de Malla Deslizante para la Simulación del Flujo en un Agitador con Turbina Rushton
Una de las principales preocupaciones sobre los reactores agitados es el tiempo de mezclado para una sustancia determinada. Las mediciones experimentales destinadas a caracterizar el desempeño de los agitadores requieren equipos costosos y especializados; por ello, las simulaciones mediante dinámica de fluidos computacional surgen como una alternativa atractiva. Entre las estrategias para abordar el problema, el método de marcos de referencia múltiples (MRF, por sus siglas en inglés) ha ganado popularidad por su sencillez en la generación de la malla y el costo reducido en el cálculo de la solución, comparado con la estrategia de malla móvil. No obstante, las soluciones obtenidas con MRF presentan dependencia en el tamaño de la zona donde se considera la rotación del fluido. En este trabajo se muestra que si bien las simulaciones con MRF proporcionan resultados precisos para índices globales del agitador, el tiempo de mezclado es sobreestimado y el campo de movimiento resulta incorrecto. A tal fin, se comparan resultados obtenidos con esta estrategia, aplicada a un mezclador de referencia equipado con una turbina Rushton, resultados experimentales, y simulaciones numéricas realizadas con malla móvil en OpenFOAM y StarCCM.
- Open Access
- 16 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1557-1565
Effective Cooling of a Distribution Transformer Using Biodegradable Oils at Different Climate Conditions
Nowadays, as an alternative to conventional mineral oils used for cooling in distribution transformers, environment-friendly ester oils are getting more attention. For this reason, the main objective of this work was to compare the cooling efficiency of both types of coolants in the medium-power distribution transformer under different ambient conditions. It was conducted by the development of a validated coupled numerical model that included all thermal, flow and electromagnetic phenomena. Moreover, all the calculations were carried out for mineral, synthetic and natural ester oils. As a result, the coupled CFD model determined the hot-spot temperature within the transformer tank at three ambient temperatures on the basis of the local distribution of the power losses in windigns and core that were delivered from the electromagnetic submodel. The investigated ambient temperatures of -10, 20 and 30°C represented summertime and wintertime for two climate conditions. The numerical results also showed a satisfactory agreement with the measured temperature values recorded in the analysed distribution transformer with mineral oil. In addition, it was presented that the highest hot-spot temperature of 94.6°C was reached for the case of natural ester oil at 30°C of the ambient temperature representing maximum monthly averaged Argentinian climate conditions. In these conditions, the hot-spot temperature transformer with mineral oil was only 1.6 K lower. Furthermore, one of the investigated synthetic ester oil allowed to reach even better cooling effectiveness than in the case of mineral oil. Therefore, more effective cooling connected with environment-friendly characteristics encourages to use biodegradable oils for distribution transformers.
- 16 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1557-1565
Open AccessEffective Cooling of a Distribution Transformer Using Biodegradable Oils at Different Climate Conditions
Nowadays, as an alternative to conventional mineral oils used for cooling in distribution transformers, environment-friendly ester oils are getting more attention. For this reason, the main objective of this work was to compare the cooling efficiency of both types of coolants in the medium-power distribution transformer under different ambient conditions. It was conducted by the development of a validated coupled numerical model that included all thermal, flow and electromagnetic phenomena. Moreover, all the calculations were carried out for mineral, synthetic and natural ester oils. As a result, the coupled CFD model determined the hot-spot temperature within the transformer tank at three ambient temperatures on the basis of the local distribution of the power losses in windigns and core that were delivered from the electromagnetic submodel. The investigated ambient temperatures of -10, 20 and 30°C represented summertime and wintertime for two climate conditions. The numerical results also showed a satisfactory agreement with the measured temperature values recorded in the analysed distribution transformer with mineral oil. In addition, it was presented that the highest hot-spot temperature of 94.6°C was reached for the case of natural ester oil at 30°C of the ambient temperature representing maximum monthly averaged Argentinian climate conditions. In these conditions, the hot-spot temperature transformer with mineral oil was only 1.6 K lower. Furthermore, one of the investigated synthetic ester oil allowed to reach even better cooling effectiveness than in the case of mineral oil. Therefore, more effective cooling connected with environment-friendly characteristics encourages to use biodegradable oils for distribution transformers.
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 766-769
Coupled CFD and electromagnetic analysis of an ONAN distribution transformer cooled with mineral oil and biodegradable esters
This work describes the electromagnetic and coupled thermo-fluid dynamic analysis of an oil-natural air-natural (ONAN) distribution transformer with the main objective of studying the changes in the heat dissipation performance when the fluid employed to cool the machine is a biodegradable ester instead of mineral oil. The distribution transformer under analysis has a rated power of 315 kVA with a voltage ratio of 13.2 kV / 0.4 kV. The heat losses in the magnetic core and the windings are computed with the ANSYS Maxwell software on suitable finite element meshes. These heat losses are then transferred as volume heat source terms to appropriate finite volume meshes which are used to compute the heat conduction in the core and windings, then the heat dissipates to the oil by convection, afterwards to the walls of the oil tank and to the radiators panels and finally to the surrounding air. In the thermo-fluid dynamic model, the natural convection of the fluid flow is taken into account using a temperature-dependent density. Moreover, the heat conduction through the metal sheet of the oil tank and the radiators panels are considered. The coupled thermo-hydraulic problem is solved with Code_Satume software. The experimental data of the total power losses provided by the unit manufacturer were employed to validate the electro- magnetic model. Because the thermo-fluid dynamic numerical model is computationally expensive, only one quarter of the transformer is modelled. In addition, equivalent anisotropic thermal conductivity in the core and windings are calculated to simplify the heat conduction model in the active parts. The differences in the temperature distribution and oil flow observed between the transformer working with a standard mineral oil and a biodegradable ester are discussed. This work is carried out as part of the EU Horizon 2020 BIOTRAFO project.
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 766-769
Coupled CFD and electromagnetic analysis of an ONAN distribution transformer cooled with mineral oil and biodegradable esters
This work describes the electromagnetic and coupled thermo-fluid dynamic analysis of an oil-natural air-natural (ONAN) distribution transformer with the main objective of studying the changes in the heat dissipation performance when the fluid employed to cool the machine is a biodegradable ester instead of mineral oil. The distribution transformer under analysis has a rated power of 315 kVA with a voltage ratio of 13.2 kV / 0.4 kV. The heat losses in the magnetic core and the windings are computed with the ANSYS Maxwell software on suitable finite element meshes. These heat losses are then transferred as volume heat source terms to appropriate finite volume meshes which are used to compute the heat conduction in the core and windings, then the heat dissipates to the oil by convection, afterwards to the walls of the oil tank and to the radiators panels and finally to the surrounding air. In the thermo-fluid dynamic model, the natural convection of the fluid flow is taken into account using a temperature-dependent density. Moreover, the heat conduction through the metal sheet of the oil tank and the radiators panels are considered. The coupled thermo-hydraulic problem is solved with Code_Satume software. The experimental data of the total power losses provided by the unit manufacturer were employed to validate the electro- magnetic model. Because the thermo-fluid dynamic numerical model is computationally expensive, only one quarter of the transformer is modelled. In addition, equivalent anisotropic thermal conductivity in the core and windings are calculated to simplify the heat conduction model in the active parts. The differences in the temperature distribution and oil flow observed between the transformer working with a standard mineral oil and a biodegradable ester are discussed. This work is carried out as part of the EU Horizon 2020 BIOTRAFO project.
- 1 March 2019
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 137, 64-74
Heat transfer enhancement in panel type radiators using delta-wing vortex generators
- 1 March 2019
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 137, 64-74
Heat transfer enhancement in panel type radiators using delta-wing vortex generators
- Open Access
- 1 July 2016
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 58, 117-126
Evaluation of a coupling interface for solving fluid–structure interaction problems
- 1 July 2016
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 58, 117-126
Open AccessEvaluation of a coupling interface for solving fluid–structure interaction problems
- 1 March 2016
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 300, 106-128
An embedded strategy for the analysis of fluid structure interaction problems
- 1 March 2016
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 300, 106-128
An embedded strategy for the analysis of fluid structure interaction problems
- 1 December 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (12) , 1273-1280
Characterisation and simulation of an active microvalve for glaucoma
Glaucoma drainage device (GDD) has the potential to eliminate hypotony but still suffers from poor flow control and fibrosis. The ideal shunt should change its hydraulic resistance to achieve the desired intraocular pressure (IOP). In this study, the characterisation of a preliminary design of a new GDD is presented. This is activated by means of a diaphragm, which is actuated by conducting polymers. The valve can be manufactured employing microelectromechanical system technology by soft lithography. The characterisation process is performed by numerical simulation using the finite element method, considering the coupling between the fluid and the structure (diaphragm) obtaining the hydraulic resistance for several positions of the diaphragm. To analyse the hydraulic system of the microvalve implanted in a human eye, an equivalent circuit model was used. The parameters of the equivalent circuit model were obtained from numerical simulation. The hydraulic resistance of the designed GDD varies in the range of 13.08–0.36 mmHg min/μl compared with 3.38–0.43 mmHg min/μl for the Ahmed valve. The maximum displacement of the diaphragm in the vertical direction is 18.9 μm, and the strain in the plane is 2%. The proposed preliminary design allows to control the IOP by varying the hydraulic resistance in a greater range than the existing passive valves, and the numerical simulation facilitates the characterisation and the improvement of the design before its construction, reducing time and costs.
- 1 December 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (12) , 1273-1280
Characterisation and simulation of an active microvalve for glaucoma
Glaucoma drainage device (GDD) has the potential to eliminate hypotony but still suffers from poor flow control and fibrosis. The ideal shunt should change its hydraulic resistance to achieve the desired intraocular pressure (IOP). In this study, the characterisation of a preliminary design of a new GDD is presented. This is activated by means of a diaphragm, which is actuated by conducting polymers. The valve can be manufactured employing microelectromechanical system technology by soft lithography. The characterisation process is performed by numerical simulation using the finite element method, considering the coupling between the fluid and the structure (diaphragm) obtaining the hydraulic resistance for several positions of the diaphragm. To analyse the hydraulic system of the microvalve implanted in a human eye, an equivalent circuit model was used. The parameters of the equivalent circuit model were obtained from numerical simulation. The hydraulic resistance of the designed GDD varies in the range of 13.08–0.36 mmHg min/μl compared with 3.38–0.43 mmHg min/μl for the Ahmed valve. The maximum displacement of the diaphragm in the vertical direction is 18.9 μm, and the strain in the plane is 2%. The proposed preliminary design allows to control the IOP by varying the hydraulic resistance in a greater range than the existing passive valves, and the numerical simulation facilitates the characterisation and the improvement of the design before its construction, reducing time and costs.
- 6 September 2011
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 69 (12) , 1872-1890
A finite element formulation satisfying the discrete geometric conservation law based on averaged Jacobians
- 6 September 2011
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 69 (12) , 1872-1890
A finite element formulation satisfying the discrete geometric conservation law based on averaged Jacobians