  • Open Access

    Dinámica de una Boya Sometida a Oleaje Mediante un Canal de Olas Numérico

    by Laura Battaglia, Gustavo Ríos Rodríguez, Mario A. Storti, Lisandro M. Rojas, Franco E. Dotti

    Una alternativa relevante para generación de energía renovables es el potencial del oleaje en entornos marinos, por ejemplo, mediante elementos flotantes tipo boya. En este trabajo, se estudia la dinámica de una boya propuesta como soporte para un generador eléctrico pendular, con el propósito de establecer el régimen de desplazamientos a considerar para el diseño y análisis del dispositivo. A tal fin, se generarán dos modelos, el primero basado en las ecuaciones de aguas someras con capacidad de caracterizar amplitud y período de oleaje, y el segundo para estudiar en un canal numérico de olas el problema de interacción fluido-estructura de movimiento del cuerpo flotante, en ambos casos empleando software libre. Los modelos serán validados, para luego aplicarlos al estudio del generador pendular.

  • Open Access

    Análisis Comparativo de las Estrategia MRF y de Malla Deslizante para la Simulación del Flujo en un Agitador con Turbina Rushton

    by Gustavo A. Ríos Rodríguez, Luciano Garelli, Mario A. Storti

    Una de las principales preocupaciones sobre los reactores agitados es el tiempo de mezclado para una sustancia determinada. Las mediciones experimentales destinadas a caracterizar el desempeño de los agitadores requieren equipos costosos y especializados; por ello, las simulaciones mediante dinámica de fluidos computacional surgen como una alternativa atractiva. Entre las estrategias para abordar el problema, el método de marcos de referencia múltiples (MRF, por sus siglas en inglés) ha ganado popularidad por su sencillez en la generación de la malla y el costo reducido en el cálculo de la solución, comparado con la estrategia de malla móvil. No obstante, las soluciones obtenidas con MRF presentan dependencia en el tamaño de la zona donde se considera la rotación del fluido. En este trabajo se muestra que si bien las simulaciones con MRF proporcionan resultados precisos para índices globales del agitador, el tiempo de mezclado es sobreestimado y el campo de movimiento resulta incorrecto. A tal fin, se comparan resultados obtenidos con esta estrategia, aplicada a un mezclador de referencia equipado con una turbina Rushton, resultados experimentales, y simulaciones numéricas realizadas con malla móvil en OpenFOAM y StarCCM.

  • Open Access

    Effective Cooling of a Distribution Transformer Using Biodegradable Oils at Different Climate Conditions

    by Bartlomiej Melka, Michal Stebel, Jakub Bodys, Krzysztof Kubiczek, Pawel Lasek, Gustavo Rios Rodriguez, Luciano Garelli, Michal Haida, Michal Palacz, Andrzej J. Nowak, et al.

    Nowadays, as an alternative to conventional mineral oils used for cooling in distribution transformers, environment-friendly ester oils are getting more attention. For this reason, the main objective of this work was to compare the cooling efficiency of both types of coolants in the medium-power distribution transformer under different ambient conditions. It was conducted by the development of a validated coupled numerical model that included all thermal, flow and electromagnetic phenomena. Moreover, all the calculations were carried out for mineral, synthetic and natural ester oils. As a result, the coupled CFD model determined the hot-spot temperature within the transformer tank at three ambient temperatures on the basis of the local distribution of the power losses in windigns and core that were delivered from the electromagnetic submodel. The investigated ambient temperatures of -10, 20 and 30°C represented summertime and wintertime for two climate conditions. The numerical results also showed a satisfactory agreement with the measured temperature values recorded in the analysed distribution transformer with mineral oil. In addition, it was presented that the highest hot-spot temperature of 94.6°C was reached for the case of natural ester oil at 30°C of the ambient temperature representing maximum monthly averaged Argentinian climate conditions. In these conditions, the hot-spot temperature transformer with mineral oil was only 1.6 K lower. Furthermore, one of the investigated synthetic ester oil allowed to reach even better cooling effectiveness than in the case of mineral oil. Therefore, more effective cooling connected with environment-friendly characteristics encourages to use biodegradable oils for distribution transformers.


  • Coupled CFD and electromagnetic analysis of an ONAN distribution transformer cooled with mineral oil and biodegradable esters

    by Gustavo Rios Rodriguez, Luciano Garelli, Mario A. Storti, Krzysztof Kubiczek, Pawel Lasek, Mariusz Stepien, Michal Stebel, Bartlomiej Melka, Jakub Bodys, Michal Haida, et al.

    This work describes the electromagnetic and coupled thermo-fluid dynamic analysis of an oil-natural air-natural (ONAN) distribution transformer with the main objective of studying the changes in the heat dissipation performance when the fluid employed to cool the machine is a biodegradable ester instead of mineral oil. The distribution transformer under analysis has a rated power of 315 kVA with a voltage ratio of 13.2 kV / 0.4 kV. The heat losses in the magnetic core and the windings are computed with the ANSYS Maxwell software on suitable finite element meshes. These heat losses are then transferred as volume heat source terms to appropriate finite volume meshes which are used to compute the heat conduction in the core and windings, then the heat dissipates to the oil by convection, afterwards to the walls of the oil tank and to the radiators panels and finally to the surrounding air. In the thermo-fluid dynamic model, the natural convection of the fluid flow is taken into account using a temperature-dependent density. Moreover, the heat conduction through the metal sheet of the oil tank and the radiators panels are considered. The coupled thermo-hydraulic problem is solved with Code_Satume software. The experimental data of the total power losses provided by the unit manufacturer were employed to validate the electro- magnetic model. Because the thermo-fluid dynamic numerical model is computationally expensive, only one quarter of the transformer is modelled. In addition, equivalent anisotropic thermal conductivity in the core and windings are calculated to simplify the heat conduction model in the active parts. The differences in the temperature distribution and oil flow observed between the transformer working with a standard mineral oil and a biodegradable ester are discussed. This work is carried out as part of the EU Horizon 2020 BIOTRAFO project.