Zunyan Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zunyan Hu has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Jianqiu Li
16 shared publications- Liangfei Xu
School of Vehicle and Mobility, Tsinghua University, Beijing, China
16 shared publications Minggao Ouyang
13 shared publications- Minggao Ouyang
State Key Laboratory of Intelligent Green Vehicle and Mobility, Tsinghua University, Beijing 100084, China
6 shared publications - Yangbin Shao
State Key Lab of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing, 100084, China
4 shared publications - Jianqiu Li
School of Vehicle and Mobility, State Key Laboratory of Intelligent Green Vehicle and Mobility Tsinghua University Beijing China
3 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
Piping Configuration and Thermal Performance Optimization of a Direct Refrigerant Cooling System for a Vertically Stacked Lithium-Ion Battery Energy Storage System
Nonuniform two-phase refrigerant distribution can impair cooling in vertically stacked lithium-ion battery energy storage systems (BESSs), yet systematic comparisons of how piping configuration affects refrigerant distribution and thermal performance remain limited. We develop a three-dimensional coupled thermal–fluid CFD model for an R410A direct refrigerant cooling (DRC) system serving a 186.4-kWh BESS with four vertically stacked battery packs. Model validation against measured mean battery-cluster temperature during a 0.5P discharge at 25 °C gives a mean absolute percentage error (MAPE) of 1.76%. We compare ten fully serial, fully parallel and hybrid piping configurations. At 7200 s, fully serial D2 yields a maximum battery-cluster temperature (Tmax) of 32.20 °C and a maximum temperature difference (ΔTmax) of 3.80 °C; ΔTmax is 30.9% lower than in fully parallel D5. For D2, we use Kriging surrogates and NSGA-II to minimize Tmax and ΔTmax by optimizing inlet mass flow rate, temperature and vapor mass fraction. Entropy-weighted TOPSIS selects a Pareto-front operating point with inlet mass flow rate, temperature and vapor mass fraction of 0.050 kg/s, 15.84 °C and 0.22, respectively. Independent CFD verification shows that this condition reduces Tmax and ΔTmax by 5.3% and 10.0%, respectively, relative to baseline D2. These results inform DRC piping design and operating-parameter selection for vertically stacked BESSs.
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPiping Configuration and Thermal Performance Optimization of a Direct Refrigerant Cooling System for a Vertically Stacked Lithium-Ion Battery Energy Storage System
Nonuniform two-phase refrigerant distribution can impair cooling in vertically stacked lithium-ion battery energy storage systems (BESSs), yet systematic comparisons of how piping configuration affects refrigerant distribution and thermal performance remain limited. We develop a three-dimensional coupled thermal–fluid CFD model for an R410A direct refrigerant cooling (DRC) system serving a 186.4-kWh BESS with four vertically stacked battery packs. Model validation against measured mean battery-cluster temperature during a 0.5P discharge at 25 °C gives a mean absolute percentage error (MAPE) of 1.76%. We compare ten fully serial, fully parallel and hybrid piping configurations. At 7200 s, fully serial D2 yields a maximum battery-cluster temperature (Tmax) of 32.20 °C and a maximum temperature difference (ΔTmax) of 3.80 °C; ΔTmax is 30.9% lower than in fully parallel D5. For D2, we use Kriging surrogates and NSGA-II to minimize Tmax and ΔTmax by optimizing inlet mass flow rate, temperature and vapor mass fraction. Entropy-weighted TOPSIS selects a Pareto-front operating point with inlet mass flow rate, temperature and vapor mass fraction of 0.050 kg/s, 15.84 °C and 0.22, respectively. Independent CFD verification shows that this condition reduces Tmax and ΔTmax by 5.3% and 10.0%, respectively, relative to baseline D2. These results inform DRC piping design and operating-parameter selection for vertically stacked BESSs.
- Open Access
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Mechanisms of PEMFC unexpected performance loss under diluted hydrogen operation
Proton exchange membrane fuel cells (PEMFCs) have attracted significant attention due to low emissions, while improving system efficiency remains a critical challenge. Reducing hydrogen purge frequency can enhance hydrogen utilization; however, nitrogen crossover continuously dilutes hydrogen in the anode recirculation loop, leading to unexpectedly large voltage losses. Notably, the experimentally measured voltage degradation is approximately one order of magnitude larger than that predicted by existing models. This discrepancy hinders accurate prediction of PEMFC performance under high hydrogen utilization conditions. This study investigates the underlying mechanisms of performance loss under hydrogen dilution conditions through experiments and theoretical modeling. The results demonstrate that voltage loss increases sharply when hydrogen molar fraction (HMF) decreases below 70%. Hydrogen-pump measurements reveal that dilution increases anodic mass-transfer resistance and decreases HOR exchange current density, while a calibrated one-dimensional model further identifies reduced HOR kinetics and anode–cathode proton concentration imbalance as key contributors to the observed degradation.
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMechanisms of PEMFC unexpected performance loss under diluted hydrogen operation
Proton exchange membrane fuel cells (PEMFCs) have attracted significant attention due to low emissions, while improving system efficiency remains a critical challenge. Reducing hydrogen purge frequency can enhance hydrogen utilization; however, nitrogen crossover continuously dilutes hydrogen in the anode recirculation loop, leading to unexpectedly large voltage losses. Notably, the experimentally measured voltage degradation is approximately one order of magnitude larger than that predicted by existing models. This discrepancy hinders accurate prediction of PEMFC performance under high hydrogen utilization conditions. This study investigates the underlying mechanisms of performance loss under hydrogen dilution conditions through experiments and theoretical modeling. The results demonstrate that voltage loss increases sharply when hydrogen molar fraction (HMF) decreases below 70%. Hydrogen-pump measurements reveal that dilution increases anodic mass-transfer resistance and decreases HOR exchange current density, while a calibrated one-dimensional model further identifies reduced HOR kinetics and anode–cathode proton concentration imbalance as key contributors to the observed degradation.
- 30 September 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 697
Degradation behavior and mechanism of a reinforced high-temperature-stable PFSA membrane electrode assembly at 105 °C
- 30 September 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 697
Degradation behavior and mechanism of a reinforced high-temperature-stable PFSA membrane electrode assembly at 105 °C
- Open Access
- 23 July 2026
- Published by Elsevier in SSRN Electronic Journal
Linking through lattice water in Prussian blue analogue boosts low humidity proton conduction of polymer composite membrane for fuel cell
Sharply declined proton conductivity of proton exchange membranes (PEMs) at low relative humidity (RH) severely constricts the commercialization of proton exchange membrane fuel cells (PEMFCs). Here we develop a composite PEM using plasma-treated Prussian blue analogue (PBA) with well-linked lattice water to address this challenge. The plasma treatment generates more defect-sites of cyano-group in PBA, which accommodates tunable ligand-water, better linking the adjacent zeolitic-water to form a continuous hydrogen-bonding-network for Grotthuss proton conduction. Therefore, the PBA composite PEM achieves a proton conductivity of 102.9 mS cm-1 in water at 80 oC, and maintains 7.5 mS cm-1 at 25% RH, with much reduced conduction activation energy. In PEMFC operated at 80 oC, the composite PEM delivers power densities of 707.7 mW cm-2 and 338.0 mW cm-2 at 100% RH and 25% RH, respectively.
- 23 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessLinking through lattice water in Prussian blue analogue boosts low humidity proton conduction of polymer composite membrane for fuel cell
Sharply declined proton conductivity of proton exchange membranes (PEMs) at low relative humidity (RH) severely constricts the commercialization of proton exchange membrane fuel cells (PEMFCs). Here we develop a composite PEM using plasma-treated Prussian blue analogue (PBA) with well-linked lattice water to address this challenge. The plasma treatment generates more defect-sites of cyano-group in PBA, which accommodates tunable ligand-water, better linking the adjacent zeolitic-water to form a continuous hydrogen-bonding-network for Grotthuss proton conduction. Therefore, the PBA composite PEM achieves a proton conductivity of 102.9 mS cm-1 in water at 80 oC, and maintains 7.5 mS cm-1 at 25% RH, with much reduced conduction activation energy. In PEMFC operated at 80 oC, the composite PEM delivers power densities of 707.7 mW cm-2 and 338.0 mW cm-2 at 100% RH and 25% RH, respectively.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16368-16384
Comprehensive Analysis of Misalignment Effects on Radial-Flux Dual Rotor Direct-Drive Motors
Direct-drive dual-rotor motors (DRMs) are susceptible to performance degradation under inappropriate skewing and axis misalignment. This paper evaluates the impacts of various skew modes on large-diameter DRM performance along with stator-rotor eccentricity consideration. First, the configuration and the segment skew mode of the targeted DRM are demonstrated in detail. Then, a simplified bidirectional skew and axis misalignment model is proposed for a unified field oriented control (FOC) strategy. Analytical results show that it is the skew angle rather than the skew direction that affects DRM mechanical performance. However, the 3D flux vector distribution demonstrates that when the skewed segments of the inner and outer rotor are contra-directional, a unique circular flux in the radial cross-section and a balanced flux distribution in the axial cross-section are formed. Moreover, the spatiotemporal harmonic analysis reveals the barrel effect of the inner air-gap and the distinct influence of contra-skew on high-frequency harmonics. Overall, a contra-skew angle not exceeding 15 electrical degrees provides an effective design compromise among torque capability, torque ripple, and axial force. Finally, two skewed automotivegrade DRM prototypes are fabricated and measured for axis misalignment, and the torque generation and light flux-weakening (FW) characteristics of the selected prototype are experimentally validated.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16368-16384
Comprehensive Analysis of Misalignment Effects on Radial-Flux Dual Rotor Direct-Drive Motors
Direct-drive dual-rotor motors (DRMs) are susceptible to performance degradation under inappropriate skewing and axis misalignment. This paper evaluates the impacts of various skew modes on large-diameter DRM performance along with stator-rotor eccentricity consideration. First, the configuration and the segment skew mode of the targeted DRM are demonstrated in detail. Then, a simplified bidirectional skew and axis misalignment model is proposed for a unified field oriented control (FOC) strategy. Analytical results show that it is the skew angle rather than the skew direction that affects DRM mechanical performance. However, the 3D flux vector distribution demonstrates that when the skewed segments of the inner and outer rotor are contra-directional, a unique circular flux in the radial cross-section and a balanced flux distribution in the axial cross-section are formed. Moreover, the spatiotemporal harmonic analysis reveals the barrel effect of the inner air-gap and the distinct influence of contra-skew on high-frequency harmonics. Overall, a contra-skew angle not exceeding 15 electrical degrees provides an effective design compromise among torque capability, torque ripple, and axial force. Finally, two skewed automotivegrade DRM prototypes are fabricated and measured for axis misalignment, and the torque generation and light flux-weakening (FW) characteristics of the selected prototype are experimentally validated.
- 22 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Parameter Matching Principle for Dual-Rotor In-Wheel Motors via Coupling Effect Exploitation
Single-mechanical-port dual-rotor motors (DRMs) represent a promising topology for next-generation electric machines (EMs). However, the optimal parameter-matching principle between the two rotors and the stator in radial-flux configurations has not been sufficiently explored due to geometric asymmetry. This article proposes a parameter-matching principle that explicitly exploits the magnetic coupling effect. By conceptually segregating the DRM into two equivalent single-rotor EMs, the proposed principle enables accurate identification of optimally matched DRM designs, independent of optimization history. Targeting in-wheel motor (IWM) applications, the influence of parameter matching on torque and loss is systematically analyzed in the torque–loss power design space. A set of effective matching conditions are then formulated based on coupling-related geometric metrics. Additional influencing factors, including operating condition fluctuations and core material variations, are also investigated. Results reveal that the effective matching envelope primarily occupies the central region of the Pareto front rather than covering all Pareto-optimal designs. This highlights the necessity of coupling-based selection to avoid arbitrary choices from Pareto fronts. Finally, an automotive-grade DRM prototype designed under the proposed principle was fabricated and experimentally validated, achieving a peak torque exceeding 1500 Nm and a maximum efficiency above 92%, confirming the effectiveness of the proposed principle.
- 22 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Parameter Matching Principle for Dual-Rotor In-Wheel Motors via Coupling Effect Exploitation
Single-mechanical-port dual-rotor motors (DRMs) represent a promising topology for next-generation electric machines (EMs). However, the optimal parameter-matching principle between the two rotors and the stator in radial-flux configurations has not been sufficiently explored due to geometric asymmetry. This article proposes a parameter-matching principle that explicitly exploits the magnetic coupling effect. By conceptually segregating the DRM into two equivalent single-rotor EMs, the proposed principle enables accurate identification of optimally matched DRM designs, independent of optimization history. Targeting in-wheel motor (IWM) applications, the influence of parameter matching on torque and loss is systematically analyzed in the torque–loss power design space. A set of effective matching conditions are then formulated based on coupling-related geometric metrics. Additional influencing factors, including operating condition fluctuations and core material variations, are also investigated. Results reveal that the effective matching envelope primarily occupies the central region of the Pareto front rather than covering all Pareto-optimal designs. This highlights the necessity of coupling-based selection to avoid arbitrary choices from Pareto fronts. Finally, an automotive-grade DRM prototype designed under the proposed principle was fabricated and experimentally validated, achieving a peak torque exceeding 1500 Nm and a maximum efficiency above 92%, confirming the effectiveness of the proposed principle.
- Open Access
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Comprehensive investigation on high-frequency rotational magnetic properties of core materials for high-speed motors
In this paper, the rotational magnetic properties of ultra-thin non-oriented silicon steel ST100 (200 Hz - 5 kHz) are measured by the novel two-dimensional magnetic property tester, with nanocrystalline alloy 1K107B (1 kHz - 20 kHz) serving as a reference. The anisotropy behavior of these materials under varying flux densities is analyzed based on the experimental results. The change in anisotropy under circular magnetization is explained by comparing the B-H phase difference at different flux densities and frequencies. Taking the elliptical magnetization of ST100 at 1 kHz as a case study, the magnetic properties of materials with different levels of rotational magnetization are systematically investigated. By comparing the phase difference of B-H loci and the harmonic content of H at different axial ratios and flux densities, the factors contributing to the nonlinear behavior of rotational magnetization are identified. Additionally, the variation in core loss under different rotational conditions is analyzed. It can provide theoretical and data support for the magnetic structure design and loss evaluation in the high-speed motor.
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Open AccessComprehensive investigation on high-frequency rotational magnetic properties of core materials for high-speed motors
In this paper, the rotational magnetic properties of ultra-thin non-oriented silicon steel ST100 (200 Hz - 5 kHz) are measured by the novel two-dimensional magnetic property tester, with nanocrystalline alloy 1K107B (1 kHz - 20 kHz) serving as a reference. The anisotropy behavior of these materials under varying flux densities is analyzed based on the experimental results. The change in anisotropy under circular magnetization is explained by comparing the B-H phase difference at different flux densities and frequencies. Taking the elliptical magnetization of ST100 at 1 kHz as a case study, the magnetic properties of materials with different levels of rotational magnetization are systematically investigated. By comparing the phase difference of B-H loci and the harmonic content of H at different axial ratios and flux densities, the factors contributing to the nonlinear behavior of rotational magnetization are identified. Additionally, the variation in core loss under different rotational conditions is analyzed. It can provide theoretical and data support for the magnetic structure design and loss evaluation in the high-speed motor.
- 1 June 2024
- Published by Elsevier in eTransportation
- Vol. 21, 100342
Optimal performance and preliminary parameter matching for hydrogen fuel cell powertrain system of electric aircraft
- 1 June 2024
- Published by Elsevier in eTransportation
- Vol. 21, 100342
Optimal performance and preliminary parameter matching for hydrogen fuel cell powertrain system of electric aircraft
- 27 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A control method based on optimal flow rate for fuel cell cogeneration waste heat utilization system with auxiliary heat transfer loop
This paper focuses on a 78kW fuel cell cogeneration system. Firstly, a waste heat utilization system including an auxiliary heat exchange loop and its model are introduced. Then a model-based feedforward plus PI feedback control method based on optimal flow rates of two sides of the heat exchanger is proposed to ensure the cooling water temperature of the fuel cell stack and the temperature of the heated water on the cold end. Finally, the effectiveness of the control method under different stack power is verified by simulating. According to the simulation analysis, the control error of the cooling water of the stack is within 1 °C and the dynamic process of the step can occur within 120s. The efficiency of the combined heat and power (CHP) system can reach 86.2%. The control method can help ensure the normal operation of fuel cells and make full use of waste heat.
- 27 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A control method based on optimal flow rate for fuel cell cogeneration waste heat utilization system with auxiliary heat transfer loop
This paper focuses on a 78kW fuel cell cogeneration system. Firstly, a waste heat utilization system including an auxiliary heat exchange loop and its model are introduced. Then a model-based feedforward plus PI feedback control method based on optimal flow rates of two sides of the heat exchanger is proposed to ensure the cooling water temperature of the fuel cell stack and the temperature of the heated water on the cold end. Finally, the effectiveness of the control method under different stack power is verified by simulating. According to the simulation analysis, the control error of the cooling water of the stack is within 1 °C and the dynamic process of the step can occur within 120s. The efficiency of the combined heat and power (CHP) system can reach 86.2%. The control method can help ensure the normal operation of fuel cells and make full use of waste heat.
- Open Access
- 1 September 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (9) , 094508
Optimizing Catalyst Layer Structure with Carbon Nanofiber Additive for Better Performance of Proton Exchange Membrane Fuel Cell
Increasing the power density of proton exchange membrane fuel cell (PEMFC) is essential for its commercialization. Cathode catalyst layer (CCL) carbon additive is an effective method that can improve membrane electrode assembly (MEA) performance under high current density. In this work, carbon nanofiber (CNF) is used as CCL additive and its mechanism is studied. The influence of CNF on the CCL structure is studied by scanning electron microscope (SEM), nitrogen adsorption method and contact angle experiment. Meanwhile, the mechanism is examined by using polarization decomposition and impedance analysis combined with the result in characterization experiments. The results show that: (1) the MEA used in this work has the best performance when adding 1 wt%. The voltage rises 74 mV (15.42%) at 2 A cm−2; (2) CNF varies the MEA performance mainly through changing the hydrophobicity of CCL, influencing the mass transport resistance and the concentration polarization. The mass transport resistance decreases 57.18% at 2 A cm−2; (3) activation polarization values have a negative linear correlation with the peak volume values of the primary pores at around 4 nm in diameter. This study provided a detailed understanding of the mechanism of CNF additive in CCL and will be helpful for improving PEMFC performance.
- 1 September 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (9) , 094508
Open AccessOptimizing Catalyst Layer Structure with Carbon Nanofiber Additive for Better Performance of Proton Exchange Membrane Fuel Cell
Increasing the power density of proton exchange membrane fuel cell (PEMFC) is essential for its commercialization. Cathode catalyst layer (CCL) carbon additive is an effective method that can improve membrane electrode assembly (MEA) performance under high current density. In this work, carbon nanofiber (CNF) is used as CCL additive and its mechanism is studied. The influence of CNF on the CCL structure is studied by scanning electron microscope (SEM), nitrogen adsorption method and contact angle experiment. Meanwhile, the mechanism is examined by using polarization decomposition and impedance analysis combined with the result in characterization experiments. The results show that: (1) the MEA used in this work has the best performance when adding 1 wt%. The voltage rises 74 mV (15.42%) at 2 A cm−2; (2) CNF varies the MEA performance mainly through changing the hydrophobicity of CCL, influencing the mass transport resistance and the concentration polarization. The mass transport resistance decreases 57.18% at 2 A cm−2; (3) activation polarization values have a negative linear correlation with the peak volume values of the primary pores at around 4 nm in diameter. This study provided a detailed understanding of the mechanism of CNF additive in CCL and will be helpful for improving PEMFC performance.