Declan Tucker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Declan Tucker has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan V. Pearce
National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, United Kingdom
5 shared publications Trevor Ford
CCPI Europe Ltd., Vector 31 Business Park, Waleswood Way, Sheffield, S26 5NU, United Kingdom
2 shared publications- A. D. Greenen
Leonardo UK Ltd. (United Kingdom)
1 shared publication Adam Greenen
Temperature & Humidity, National Physical Laboratory, Hampton Road, Teddington, Middlesex, London, TW11 0LW, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publication- Anupam Prasad Vedurmudi
Physikalisch-Technische Bundesanstalt
1 shared publication Aurik Andreu
1 shared publication
Latest Publications
- Open Access
Measurement Uncertainty Evaluation for Sensor Network Metrology
Sensor networks, which are increasingly being used in a broad range of applications, constitute a measurement paradigm involving ensembles of sensors measuring possibly different quantities at a discrete sample of spatial locations and temporal points outside the laboratory. If sensor networks are to be considered as true metrology systems and the measurement results derived from them used for decision-making, such as in a regulatory context, it is important that the results are accompanied by reliable statements of measurement uncertainty. This paper gives a preview of some of the work undertaken within the European-funded ‘Fundamental principles of sensor network metrology (FunSNM)’ project to address the challenges of measurement uncertainty evaluation in some real-world sensor network applications. The applications demonstrate that sensor networks possess features related to the nature of the measured quantities, to the nature of the measurement model, and to the nature of the measured data. These features make conventional methods of measurement uncertainty evaluation, and established guidelines for measurement uncertainty evaluation difficult to apply. An overview of some of the modelling tools used to address the challenges of measurement uncertainty evaluation in those applications is given.
Open AccessMeasurement Uncertainty Evaluation for Sensor Network Metrology
Sensor networks, which are increasingly being used in a broad range of applications, constitute a measurement paradigm involving ensembles of sensors measuring possibly different quantities at a discrete sample of spatial locations and temporal points outside the laboratory. If sensor networks are to be considered as true metrology systems and the measurement results derived from them used for decision-making, such as in a regulatory context, it is important that the results are accompanied by reliable statements of measurement uncertainty. This paper gives a preview of some of the work undertaken within the European-funded ‘Fundamental principles of sensor network metrology (FunSNM)’ project to address the challenges of measurement uncertainty evaluation in some real-world sensor network applications. The applications demonstrate that sensor networks possess features related to the nature of the measured quantities, to the nature of the measurement model, and to the nature of the measured data. These features make conventional methods of measurement uncertainty evaluation, and established guidelines for measurement uncertainty evaluation difficult to apply. An overview of some of the modelling tools used to address the challenges of measurement uncertainty evaluation in those applications is given.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 090007
In-situ traceability to the ITS-90 using integrated self-validating thermocouples – Trials of the INSEVA thermocouple
Thermocouples are one of the most commonly used temperature sensors in industry, but over time they suffer from calibration drift due to exposure to a variety o Thermocouples are one of the most commonly used temperature sensors in industry, but over time they suffer from calibration drift due to exposure to a variety o
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 090007
In-situ traceability to the ITS-90 using integrated self-validating thermocouples – Trials of the INSEVA thermocouple
Thermocouples are one of the most commonly used temperature sensors in industry, but over time they suffer from calibration drift due to exposure to a variety o Thermocouples are one of the most commonly used temperature sensors in industry, but over time they suffer from calibration drift due to exposure to a variety o
- Open Access
- 5 April 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (7) , 075003
Thermoelectric stability of dual-wall and conventional type K and N thermocouples
Mineral insulated metal sheathed (MIMS) base metal thermocouples experience thermoelectric drift over their lifetime caused by use at high temperatures and metallurgical changes, causing spurious measurement errors. CCPI Europe Limited and University of Cambridge have designed a MIMS thermocouple with an additional inner sheath, in order to protect the thermoelements from the effects that cause thermoelectric drift. The performance of these dual-wall thermocouples and conventional type N and type K thermocouples are assessed at six different National Metrology Institutes (NMIs) using two different testing regimes: isothermal testing at 1200 °C, and thermal cycling tests between 300 °C and 1150 °C. The investigation demonstrates that in both testing regimes, the type N dual-wall thermocouples showed a significantly reduced thermoelectric drift by about a factor of three compared to the conventional thermocouples. There was no significant difference between the type K dual-wall and conventional type K thermocouples in the isothermal tests, and the type K dual-wall thermocouples showed greater drift than the conventional thermocouples in the thermal cycling tests, but the conventional type K thermocouples were less robust than the dual-wall type K thermocouples. The results presented in this paper represent an impartial assessment of the thermoelectric stability of both dual-wall thermocouples and conventional thermocouples, which may provide assurance to potential users.
- 5 April 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (7) , 075003
Open AccessThermoelectric stability of dual-wall and conventional type K and N thermocouples
Mineral insulated metal sheathed (MIMS) base metal thermocouples experience thermoelectric drift over their lifetime caused by use at high temperatures and metallurgical changes, causing spurious measurement errors. CCPI Europe Limited and University of Cambridge have designed a MIMS thermocouple with an additional inner sheath, in order to protect the thermoelements from the effects that cause thermoelectric drift. The performance of these dual-wall thermocouples and conventional type N and type K thermocouples are assessed at six different National Metrology Institutes (NMIs) using two different testing regimes: isothermal testing at 1200 °C, and thermal cycling tests between 300 °C and 1150 °C. The investigation demonstrates that in both testing regimes, the type N dual-wall thermocouples showed a significantly reduced thermoelectric drift by about a factor of three compared to the conventional thermocouples. There was no significant difference between the type K dual-wall and conventional type K thermocouples in the isothermal tests, and the type K dual-wall thermocouples showed greater drift than the conventional thermocouples in the thermal cycling tests, but the conventional type K thermocouples were less robust than the dual-wall type K thermocouples. The results presented in this paper represent an impartial assessment of the thermoelectric stability of both dual-wall thermocouples and conventional thermocouples, which may provide assurance to potential users.
- 27 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (4) , 044005
Stability assessment of a new high strength, high temperature Type R and Type S thermocouple
Platinum-rhodium Type R and S thermocouples fail in service because of two main reasons: excessive grain growth in the platinum limb at high temperatures (causing wire breakage) and temperature drift, i.e. deviation of electromotive force (emf) generated over time because of deposition of rhodium oxide on the platinum limb, out of accepted industry tolerances. Finding a solution to the problem is challenging because of the contradictory requirements of strength and narrow permissible emf range: emf is extremely sensitive to any dopants or alloying elements that can be used to improve strength at high temperatures. Johnson Matthey has developed a new thermocouple wire (platinum limb) called 'HTX™' by doping platinum with a small quantity of zirconium which is oxidised during processing to electrically neutral zirconium oxide. Zirconium oxide improves the high temperature strength of platinum wire by restricting the grain growth but does not significantly affect the emf. The result is a wire which has the potential to last many times longer at high temperatures (>1200 °C) than standard platinum wire, whilst still achieving Class 1 tolerance (i.e. ± 1 °C at 1000 °C). It also improves the thermoelectric drift characteristics of the thermocouple by counteracting any reduction in emf due to rhodium contamination by an increase in emf as any remaining zirconium is converted to zirconium oxide. We describe an impartial long-term assessment (up to 1500 hours) of the thermoelectric stability of the HTX™ wire by exposure to high temperature with periodic in-situ calibration using a Co-C (1324 °C) high temperature fixed point. This yields stability measurements with very high precision.
- 27 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (4) , 044005
Stability assessment of a new high strength, high temperature Type R and Type S thermocouple
Platinum-rhodium Type R and S thermocouples fail in service because of two main reasons: excessive grain growth in the platinum limb at high temperatures (causing wire breakage) and temperature drift, i.e. deviation of electromotive force (emf) generated over time because of deposition of rhodium oxide on the platinum limb, out of accepted industry tolerances. Finding a solution to the problem is challenging because of the contradictory requirements of strength and narrow permissible emf range: emf is extremely sensitive to any dopants or alloying elements that can be used to improve strength at high temperatures. Johnson Matthey has developed a new thermocouple wire (platinum limb) called 'HTX™' by doping platinum with a small quantity of zirconium which is oxidised during processing to electrically neutral zirconium oxide. Zirconium oxide improves the high temperature strength of platinum wire by restricting the grain growth but does not significantly affect the emf. The result is a wire which has the potential to last many times longer at high temperatures (>1200 °C) than standard platinum wire, whilst still achieving Class 1 tolerance (i.e. ± 1 °C at 1000 °C). It also improves the thermoelectric drift characteristics of the thermocouple by counteracting any reduction in emf due to rhodium contamination by an increase in emf as any remaining zirconium is converted to zirconium oxide. We describe an impartial long-term assessment (up to 1500 hours) of the thermoelectric stability of the HTX™ wire by exposure to high temperature with periodic in-situ calibration using a Co-C (1324 °C) high temperature fixed point. This yields stability measurements with very high precision.
- 31 August 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (10) , 105002
Integrated self-validating thermocouples with a reference temperature up to 1329 °C
- 31 August 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (10) , 105002
Integrated self-validating thermocouples with a reference temperature up to 1329 °C
- 29 June 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (4) , 558-567
A systematic investigation of the thermoelectric stability of Pt–Rh thermocouples between 1300 °C and 1500 °C
- 29 June 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (4) , 558-567
A systematic investigation of the thermoelectric stability of Pt–Rh thermocouples between 1300 °C and 1500 °C
- 3 August 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (9) , 141
A Slimline Integrated Self-Validating Thermocouple: Initial Results
- 3 August 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (9) , 141
A Slimline Integrated Self-Validating Thermocouple: Initial Results