Yu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yu Wang has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Shubin Liu
University of Science and Technology of China
18 shared publications - Chang-Qing Feng
University of Science and Technology of China
15 shared publications - Zhiyong Zhang
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
7 shared publications - Zhihang Yao
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China 1 , Hefei 230026
6 shared publications - Zhengyang He
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China 1 , Hefei 230026
5 shared publications - Ziwen Pan
University of Science and Technology of China
5 shared publications
Latest Publications
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (7) , 1-11
A Real-Time FPGA-Based DC-SQUID Emulator Using Exponential Time Differencing
The Direct-Current Superconducting Quantum Interference Device (DC-SQUID) offers exceptional sensitivity but requires cryogenic environments, bottlenecking early-stage hardware development. While software simulations provide high-fidelity analysis, they lack real-time hardware interaction, making hardware emulators a valuable tool for real-time testing and system validation. Distinct from existing implementations, we present a room-temperature, physics-based DC-SQUID emulator implemented on a Field-Programmable Gate Array (FPGA), particularly for the overdamped regime. It solves the complete Resistively and Capacitively Shunted Junction (RCSJ) model using an Exponential Time Differencing (ETD) method and employs a parallel, pipelined architecture for high-throughput computation. The emulator can track changes in bias current at 11.6 kHz and applied magnetic flux at 150 MHz, covering the dynamic ranges typical of DC-SQUID applications. Built on the RCSJ model, the emulator responds simultaneously to changes in both bias current and magnetic flux, providing a room-temperature surrogate that closely follows DC-SQUID dynamics. This physics-based representation, together with its real-time operation and digital flexibility, enables early functional testing of complex control schemes, offers a practical room-temperature hardware-in-the-loop platform, and provides an intuitive means to demonstrate core DC-SQUID characteristics.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36  (7) , 1-11
A Real-Time FPGA-Based DC-SQUID Emulator Using Exponential Time Differencing
The Direct-Current Superconducting Quantum Interference Device (DC-SQUID) offers exceptional sensitivity but requires cryogenic environments, bottlenecking early-stage hardware development. While software simulations provide high-fidelity analysis, they lack real-time hardware interaction, making hardware emulators a valuable tool for real-time testing and system validation. Distinct from existing implementations, we present a room-temperature, physics-based DC-SQUID emulator implemented on a Field-Programmable Gate Array (FPGA), particularly for the overdamped regime. It solves the complete Resistively and Capacitively Shunted Junction (RCSJ) model using an Exponential Time Differencing (ETD) method and employs a parallel, pipelined architecture for high-throughput computation. The emulator can track changes in bias current at 11.6 kHz and applied magnetic flux at 150 MHz, covering the dynamic ranges typical of DC-SQUID applications. Built on the RCSJ model, the emulator responds simultaneously to changes in both bias current and magnetic flux, providing a room-temperature surrogate that closely follows DC-SQUID dynamics. This physics-based representation, together with its real-time operation and digital flexibility, enables early functional testing of complex control schemes, offers a practical room-temperature hardware-in-the-loop platform, and provides an intuitive means to demonstrate core DC-SQUID characteristics.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP  (00189499) , 1
A Channel-Multiplexing Readout Method for Pixelated CdZnTe Detectors
The demand for a large number of readout channels has been a limiting factor for the application of pixelated cadmium zinc telluride (CdZnTe) detectors in larger detection areas. This challenge is further compounded by issues related to system integration, power consumption, and cost efficiency. To address these challenges, this study proposes a multiplexing method. The proposed readout scheme utilizes m + n electronics channels to read out (m + 1) × n detector electrodes, where m is the number of pixel anodes per detector, and n represents the total number of detectors in the array. This article investigates two challenges arising from the multiplexing method—noise and event misidentification—through a comparative study between direct and multiplexing readout modes. Experimental results demonstrate that after multiplexing, the average energy resolution of the pixels degrades from 1.64% full-width at half-maximum (FWHM) to 2.16% FWHM at 662 keV, while 98% of all events can be correctly identified. Therefore, the multiplexing method can significantly reduce the number of readout channels while achieving high energy resolution. These results indicate the potential of the proposed multiplexing technique for applications in fields requiring high-resolution and cost-effective detector systems, such as gamma-ray imaging.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP  (00189499) , 1
A Channel-Multiplexing Readout Method for Pixelated CdZnTe Detectors
The demand for a large number of readout channels has been a limiting factor for the application of pixelated cadmium zinc telluride (CdZnTe) detectors in larger detection areas. This challenge is further compounded by issues related to system integration, power consumption, and cost efficiency. To address these challenges, this study proposes a multiplexing method. The proposed readout scheme utilizes m + n electronics channels to read out (m + 1) × n detector electrodes, where m is the number of pixel anodes per detector, and n represents the total number of detectors in the array. This article investigates two challenges arising from the multiplexing method—noise and event misidentification—through a comparative study between direct and multiplexing readout modes. Experimental results demonstrate that after multiplexing, the average energy resolution of the pixels degrades from 1.64% full-width at half-maximum (FWHM) to 2.16% FWHM at 662 keV, while 98% of all events can be correctly identified. Therefore, the multiplexing method can significantly reduce the number of readout channels while achieving high energy resolution. These results indicate the potential of the proposed multiplexing technique for applications in fields requiring high-resolution and cost-effective detector systems, such as gamma-ray imaging.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97  (3)
Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers
High-sensitivity and wide-bandwidth magnetometers are crucial for both terrestrial and space-based geophysical applications. In this work, we present an electronics design tailored for a helium optically pumped magnetometer (He-OPM) operating under ambient geomagnetic field conditions. The proposed design features low noise and fast response, which are critical for achieving high bandwidth and high sensitivity in He-OPMs. In addition, a phase compensation method is introduced to reduce phase errors introduced by the signal transmission path, including electronic delays, thereby improving measurement accuracy. The system performance is evaluated in a laboratory environment using a frequency-stabilized laser and effective magnetic shielding. Experimental results demonstrate that the influence of the electronics on measurement accuracy is below 40 pT per 1 μT, and the system achieves a bandwidth of 650 Hz. Under an applied magnetic field of ∼0.65 μT, the He-OPM achieves a sensitivity of 620fT/Hz@1Hz in closed-loop operation.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97  (3)
Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers
High-sensitivity and wide-bandwidth magnetometers are crucial for both terrestrial and space-based geophysical applications. In this work, we present an electronics design tailored for a helium optically pumped magnetometer (He-OPM) operating under ambient geomagnetic field conditions. The proposed design features low noise and fast response, which are critical for achieving high bandwidth and high sensitivity in He-OPMs. In addition, a phase compensation method is introduced to reduce phase errors introduced by the signal transmission path, including electronic delays, thereby improving measurement accuracy. The system performance is evaluated in a laboratory environment using a frequency-stabilized laser and effective magnetic shielding. Experimental results demonstrate that the influence of the electronics on measurement accuracy is below 40 pT per 1 μT, and the system achieves a bandwidth of 650 Hz. Under an applied magnetic field of ∼0.65 μT, the He-OPM achieves a sensitivity of 620fT/Hz@1Hz in closed-loop operation.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73  (3) , 695-705
Readout Electronics for a Prototype Neutron Resonance Imaging System With 10 B-Doped MCP Detector
Neutron Resonance Imaging (NRI) is a non-destructive material analysis method utilizing energy-dependent resonance absorption. The key challenge for its readout electronics is to operate at instantaneous event rates exceeding MHz while achieving low noise and high time resolution. In this paper, we present a design of readout electronics for a prototype NRI system with a 10B-doped microchannel plate (MCP). The prototype has 256 channels for charge and time-of-flight (TOF) measurement. The triggerless and the self-trigger are employed separately in high and low event rate time periods. During the high-event-rate period, with an event rate exceeding 200 kHz, the electronics actively creates two long time windows to perform complete waveform digitization. Then, the electronics automatically switches to the self-trigger in the low-event-rate period. The complete waveform can be stored and read out during the low-event-rate period. This design enables no dead time in the high-event-rate period and reduces the amount of data in the low-event-rate period. Test results show that the minimum interval between two triggers is 1.7 μs during the low-event-rate period, corresponding to a maximum instantaneous trigger rate of up to 580 kHz. The accuracy of the neutron TOF is better than 3 ns. The RMS of the noise is less than 0.3 fC. Finally, the readout electronics was assembled with the prototype and tested on the neutron beam at CSNS Back-n. The samples made of different metals were successfully imaged.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73  (3) , 695-705
Readout Electronics for a Prototype Neutron Resonance Imaging System With 10 B-Doped MCP Detector
Neutron Resonance Imaging (NRI) is a non-destructive material analysis method utilizing energy-dependent resonance absorption. The key challenge for its readout electronics is to operate at instantaneous event rates exceeding MHz while achieving low noise and high time resolution. In this paper, we present a design of readout electronics for a prototype NRI system with a 10B-doped microchannel plate (MCP). The prototype has 256 channels for charge and time-of-flight (TOF) measurement. The triggerless and the self-trigger are employed separately in high and low event rate time periods. During the high-event-rate period, with an event rate exceeding 200 kHz, the electronics actively creates two long time windows to perform complete waveform digitization. Then, the electronics automatically switches to the self-trigger in the low-event-rate period. The complete waveform can be stored and read out during the low-event-rate period. This design enables no dead time in the high-event-rate period and reduces the amount of data in the low-event-rate period. Test results show that the minimum interval between two triggers is 1.7 μs during the low-event-rate period, corresponding to a maximum instantaneous trigger rate of up to 580 kHz. The accuracy of the neutron TOF is better than 3 ns. The RMS of the noise is less than 0.3 fC. Finally, the readout electronics was assembled with the prototype and tested on the neutron beam at CSNS Back-n. The samples made of different metals were successfully imaged.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73  (7) , 1
Design of the Frequency-Division Multiplexing Warm Electronics for DIXE Microcalorimeter Prototype
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73  (7) , 1
Design of the Frequency-Division Multiplexing Warm Electronics for DIXE Microcalorimeter Prototype
- Open Access
- 5 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (17)
A mobile high spatial-resolution muography instrument based on large-area Micromegas detectors
Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects the incoming muon flux from both the target object and the open sky. In this paper, we report on the construction of a high spatial-resolution muography instrument based on Micromegas detectors. Using four layers of 400×400mm2 Micromegas detectors, channel multiplexing circuits, and the versatile readout system, a movable muography instrument named μSTC-R400 was designed and constructed. Results show that the channel multiplexing circuits can resolve hit positions correctly, and the spatial resolution of the detector is approximately 190μm. Experiments were conducted at an under-construction subway tunnel and outdoors near a mountain, demonstrating μSTC-R400’s ability to maintain high spatial resolution outside the laboratory and its robustness in harsh environments.
- 5 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (17)
Open AccessA mobile high spatial-resolution muography instrument based on large-area Micromegas detectors
Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects the incoming muon flux from both the target object and the open sky. In this paper, we report on the construction of a high spatial-resolution muography instrument based on Micromegas detectors. Using four layers of 400×400mm2 Micromegas detectors, channel multiplexing circuits, and the versatile readout system, a movable muography instrument named μSTC-R400 was designed and constructed. Results show that the channel multiplexing circuits can resolve hit positions correctly, and the spatial resolution of the detector is approximately 190μm. Experiments were conducted at an under-construction subway tunnel and outdoors near a mountain, demonstrating μSTC-R400’s ability to maintain high spatial resolution outside the laboratory and its robustness in harsh environments.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96  (11)
A low-latency digital servo for optical frequency comb stabilization
As a fundamental tool in precision spectroscopy and metrology, the optical frequency comb demands exceptional stability and accuracy across diverse applications. Digital servo systems, offering advantages such as low cost and high flexibility, are increasingly employed for optical frequency comb stabilization; however, their performance is constrained by the limited control bandwidth. In this work, we present a low-latency digital servo system designed for optical frequency comb stabilization. The system is implemented on a custom-designed field-programmable gate array-based digital board. Through the optimization of filtering and phase detection algorithms, computational latency is reduced while maintaining precision, enabling a control bandwidth of 1.1 MHz. The repetition rate of the optical frequency comb is locked to a 1560 nm ultra-stable laser. The modified Allan deviation of the measured beat signal, normalized to the optical frequency, is 7.27 × 10−18 at 1 s, thereby validating the performance of the proposed digital servo system.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96  (11)
A low-latency digital servo for optical frequency comb stabilization
As a fundamental tool in precision spectroscopy and metrology, the optical frequency comb demands exceptional stability and accuracy across diverse applications. Digital servo systems, offering advantages such as low cost and high flexibility, are increasingly employed for optical frequency comb stabilization; however, their performance is constrained by the limited control bandwidth. In this work, we present a low-latency digital servo system designed for optical frequency comb stabilization. The system is implemented on a custom-designed field-programmable gate array-based digital board. Through the optimization of filtering and phase detection algorithms, computational latency is reduced while maintaining precision, enabling a control bandwidth of 1.1 MHz. The repetition rate of the optical frequency comb is locked to a 1560 nm ultra-stable laser. The modified Allan deviation of the measured beat signal, normalized to the optical frequency, is 7.27 × 10−18 at 1 s, thereby validating the performance of the proposed digital servo system.
- Open Access
- 8 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (14)
A detector-adjacent sampling and reverse mapping method for efficient muography simulation
Muography is a non-invasive imaging technique that uses cosmic-ray muons to investigate the internal structure of objects. Simulation serves as an important tool for assessing the feasibility of muography. However, when imaging large-scale objects, the process can be very time-consuming because many muons do not reach the detector. In this paper, a detector-adjacent sampling and reverse mapping method is introduced to enable efficient muography simulations. The detector-adjacent sampling approach generates muons that both match the expected flux distribution and can reach the detector. The reverse mapping approach then uses this muon information to project back onto the generating surface within the simulation scenario. This combined method improves computational efficiency by more than two orders of magnitude in simulations involving large-scale objects exceeding 10 m, while maintaining consistency with results from direct muon generation. The method is applicable to common muon-generating surfaces, such as those with planar, hemispherical, and cylindrical geometries. Evaluation metrics, including the mean square error, structural similarity index, and Kullback–Leibler divergence, are used to assess the consistency between this method and existing approaches. The results show that the proposed method achieves excellent agreement with direct generation. This framework is further applied to two imaging scenarios: a hollow iron sphere and a mountain. The findings demonstrate that the detector-adjacent sampling and reverse mapping method greatly reduces the simulation time, making it suitable for both small-scale and large-scale muography simulations.
- 8 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138  (14)
Open AccessA detector-adjacent sampling and reverse mapping method for efficient muography simulation
Muography is a non-invasive imaging technique that uses cosmic-ray muons to investigate the internal structure of objects. Simulation serves as an important tool for assessing the feasibility of muography. However, when imaging large-scale objects, the process can be very time-consuming because many muons do not reach the detector. In this paper, a detector-adjacent sampling and reverse mapping method is introduced to enable efficient muography simulations. The detector-adjacent sampling approach generates muons that both match the expected flux distribution and can reach the detector. The reverse mapping approach then uses this muon information to project back onto the generating surface within the simulation scenario. This combined method improves computational efficiency by more than two orders of magnitude in simulations involving large-scale objects exceeding 10 m, while maintaining consistency with results from direct muon generation. The method is applicable to common muon-generating surfaces, such as those with planar, hemispherical, and cylindrical geometries. Evaluation metrics, including the mean square error, structural similarity index, and Kullback–Leibler divergence, are used to assess the consistency between this method and existing approaches. The results show that the proposed method achieves excellent agreement with direct generation. This framework is further applied to two imaging scenarios: a hollow iron sphere and a mountain. The findings demonstrate that the detector-adjacent sampling and reverse mapping method greatly reduces the simulation time, making it suitable for both small-scale and large-scale muography simulations.