Zhihang Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhihang Yao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Shubin Liu
University of Science and Technology of China
6 shared publications - Yu Wang
Department of Modern Physics, University of Science and Technology of China, Hefei, China
6 shared publications - Chang-Qing Feng
University of Science and Technology of China
5 shared publications - Zhiyong Zhang
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
5 shared publications - Ting Wang
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China 2 , Hefei 230026
3 shared publications - Zhengyang He
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China 1 , Hefei 230026
3 shared publications
Latest Publications
- Open Access
- 5 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (17)
A mobile high spatial-resolution muography instrument based on large-area Micromegas detectors
Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects the incoming muon flux from both the target object and the open sky. In this paper, we report on the construction of a high spatial-resolution muography instrument based on Micromegas detectors. Using four layers of 400×400mm2 Micromegas detectors, channel multiplexing circuits, and the versatile readout system, a movable muography instrument named μSTC-R400 was designed and constructed. Results show that the channel multiplexing circuits can resolve hit positions correctly, and the spatial resolution of the detector is approximately 190μm. Experiments were conducted at an under-construction subway tunnel and outdoors near a mountain, demonstrating μSTC-R400’s ability to maintain high spatial resolution outside the laboratory and its robustness in harsh environments.
- 5 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (17)
Open AccessA mobile high spatial-resolution muography instrument based on large-area Micromegas detectors
Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects the incoming muon flux from both the target object and the open sky. In this paper, we report on the construction of a high spatial-resolution muography instrument based on Micromegas detectors. Using four layers of 400×400mm2 Micromegas detectors, channel multiplexing circuits, and the versatile readout system, a movable muography instrument named μSTC-R400 was designed and constructed. Results show that the channel multiplexing circuits can resolve hit positions correctly, and the spatial resolution of the detector is approximately 190μm. Experiments were conducted at an under-construction subway tunnel and outdoors near a mountain, demonstrating μSTC-R400’s ability to maintain high spatial resolution outside the laboratory and its robustness in harsh environments.
- Open Access
- 8 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (14)
A detector-adjacent sampling and reverse mapping method for efficient muography simulation
Muography is a non-invasive imaging technique that uses cosmic-ray muons to investigate the internal structure of objects. Simulation serves as an important tool for assessing the feasibility of muography. However, when imaging large-scale objects, the process can be very time-consuming because many muons do not reach the detector. In this paper, a detector-adjacent sampling and reverse mapping method is introduced to enable efficient muography simulations. The detector-adjacent sampling approach generates muons that both match the expected flux distribution and can reach the detector. The reverse mapping approach then uses this muon information to project back onto the generating surface within the simulation scenario. This combined method improves computational efficiency by more than two orders of magnitude in simulations involving large-scale objects exceeding 10 m, while maintaining consistency with results from direct muon generation. The method is applicable to common muon-generating surfaces, such as those with planar, hemispherical, and cylindrical geometries. Evaluation metrics, including the mean square error, structural similarity index, and Kullback–Leibler divergence, are used to assess the consistency between this method and existing approaches. The results show that the proposed method achieves excellent agreement with direct generation. This framework is further applied to two imaging scenarios: a hollow iron sphere and a mountain. The findings demonstrate that the detector-adjacent sampling and reverse mapping method greatly reduces the simulation time, making it suitable for both small-scale and large-scale muography simulations.
- 8 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (14)
Open AccessA detector-adjacent sampling and reverse mapping method for efficient muography simulation
Muography is a non-invasive imaging technique that uses cosmic-ray muons to investigate the internal structure of objects. Simulation serves as an important tool for assessing the feasibility of muography. However, when imaging large-scale objects, the process can be very time-consuming because many muons do not reach the detector. In this paper, a detector-adjacent sampling and reverse mapping method is introduced to enable efficient muography simulations. The detector-adjacent sampling approach generates muons that both match the expected flux distribution and can reach the detector. The reverse mapping approach then uses this muon information to project back onto the generating surface within the simulation scenario. This combined method improves computational efficiency by more than two orders of magnitude in simulations involving large-scale objects exceeding 10 m, while maintaining consistency with results from direct muon generation. The method is applicable to common muon-generating surfaces, such as those with planar, hemispherical, and cylindrical geometries. Evaluation metrics, including the mean square error, structural similarity index, and Kullback–Leibler divergence, are used to assess the consistency between this method and existing approaches. The results show that the proposed method achieves excellent agreement with direct generation. This framework is further applied to two imaging scenarios: a hollow iron sphere and a mountain. The findings demonstrate that the detector-adjacent sampling and reverse mapping method greatly reduces the simulation time, making it suitable for both small-scale and large-scale muography simulations.
- Open Access
- 12 August 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (6)
A simulation comparison of 3D reconstruction techniques of muography for blast furnace
To monitor industrial processes within blast furnaces (BFs) using muography, this study focuses on resolving the internal cohesive zone-dead man boundary (CDB). This boundary, which separates the furnace’s semi-plastic melting region (cohesive zone) from its stable coke core (dead man), is a key indicator of operational health. To this end, the effectiveness of various reconstruction algorithms and voxel parameters are systematically evaluated. Theoretical results demonstrate that the Limited-memory Broyden–Fletcher–Goldfarb–Shanno method with a voxel size of 0.2 m achieves the best performance in CDB reconstruction. Furthermore, as disclosed in the investigation of the detector placement configuration, at least four detectors are required to clearly visualize CDB. Eventually, discernible CDB is successfully reconstructed from simulated data for both symmetric and asymmetric BF scenarios without image filtering, which validates the potential of muography to monitor BFs.
- 12 August 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (6)
Open AccessA simulation comparison of 3D reconstruction techniques of muography for blast furnace
To monitor industrial processes within blast furnaces (BFs) using muography, this study focuses on resolving the internal cohesive zone-dead man boundary (CDB). This boundary, which separates the furnace’s semi-plastic melting region (cohesive zone) from its stable coke core (dead man), is a key indicator of operational health. To this end, the effectiveness of various reconstruction algorithms and voxel parameters are systematically evaluated. Theoretical results demonstrate that the Limited-memory Broyden–Fletcher–Goldfarb–Shanno method with a voxel size of 0.2 m achieves the best performance in CDB reconstruction. Furthermore, as disclosed in the investigation of the detector placement configuration, at least four detectors are required to clearly visualize CDB. Eventually, discernible CDB is successfully reconstructed from simulated data for both symmetric and asymmetric BF scenarios without image filtering, which validates the potential of muography to monitor BFs.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3433-3441
FIGURES: A Versatile Readout System for High-Granularity Muography Detectors
This paper presents the design and evaluation of the FIGURES (FIne GranUlarity detector Readout Electronics System), a versatile readout system developed for detectors used in muography. The system is designed to interface with tracking detectors composed of fine-grained micro-pattern gaseous detectors (MPGDs), processing signals from thousands of detector channels with high performance position sensitive readout. Its modular architecture enables adaptability across a wide range of experimental configurations. This flexibility is realized through the development of position-encoding circuits, front-end electronics cards (FECs), a data acquisition (DAQ) board, and software for real-time tracking and visualization. The position-encoding circuit multiplexes the channels from the MPGD’s output onto fewer channels on the front-end electronics board, achieving a compression ratio of up to 16:1. The FEC supports multiple configurations, employing ASICs such as AGET/STAGE and commercial off-the-shelf components like the ADAS1128, to accommodate detectors of different types and sizes. The DAQ board interfaces with up to 32 FECs via optical fibers, aggregates data streams, and transfers them to the server while simultaneously distributing clock and trigger signals to FECs for synchronization. The performance of each component, as well as the integrated system, has been validated through experimental tests. The FIGURES enables scalable, high-resolution muon imaging with flexible front-end integration and has been successfully validated in multiple muography applications.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3433-3441
FIGURES: A Versatile Readout System for High-Granularity Muography Detectors
This paper presents the design and evaluation of the FIGURES (FIne GranUlarity detector Readout Electronics System), a versatile readout system developed for detectors used in muography. The system is designed to interface with tracking detectors composed of fine-grained micro-pattern gaseous detectors (MPGDs), processing signals from thousands of detector channels with high performance position sensitive readout. Its modular architecture enables adaptability across a wide range of experimental configurations. This flexibility is realized through the development of position-encoding circuits, front-end electronics cards (FECs), a data acquisition (DAQ) board, and software for real-time tracking and visualization. The position-encoding circuit multiplexes the channels from the MPGD’s output onto fewer channels on the front-end electronics board, achieving a compression ratio of up to 16:1. The FEC supports multiple configurations, employing ASICs such as AGET/STAGE and commercial off-the-shelf components like the ADAS1128, to accommodate detectors of different types and sizes. The DAQ board interfaces with up to 32 FECs via optical fibers, aggregates data streams, and transfers them to the server while simultaneously distributing clock and trigger signals to FECs for synchronization. The performance of each component, as well as the integrated system, has been validated through experimental tests. The FIGURES enables scalable, high-resolution muon imaging with flexible front-end integration and has been successfully validated in multiple muography applications.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 765-772
A High-Compression-Ratio Channel-Multiplexing Method for Micropattern Gaseous Detectors
The demand for a large number of readout channels has been a limiting factor for the application of Micropattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further compounded by issues related to system integration, power consumption, and cost efficiency. To address these challenges, this study proposes two novel multiplexing methods based on Eulerian circuits. Mathematical calculations indicate that with n electronics channels, up to n × (n − 1)/2 − (n − 2)/2 + 1 detector channels can be read out, where n is even. Three types of multiplexing circuits were designed, implemented, and tested in combination with Micromegas detectors. Experimental results demonstrate that, for a multiplexing circuit with a factor of 8, the spatial resolution remains comparable to the direct readout method, while achieving a detection efficiency exceeding 94%. For a circuit with a multiplexing factor of 16, although the spatial resolution shows a slight degradation, the detection efficiency remains above 93.6%. These results demonstrate that the proposed multiplexing methods can significantly reduce the number of readout channels while maintaining an acceptable level of spatial resolution and detection efficiency. These findings highlight the potential of the proposed multiplexing techniques for applications in fields requiring high-resolution and cost-effective detector systems, such as cosmic-ray muon imaging.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 765-772
A High-Compression-Ratio Channel-Multiplexing Method for Micropattern Gaseous Detectors
The demand for a large number of readout channels has been a limiting factor for the application of Micropattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further compounded by issues related to system integration, power consumption, and cost efficiency. To address these challenges, this study proposes two novel multiplexing methods based on Eulerian circuits. Mathematical calculations indicate that with n electronics channels, up to n × (n − 1)/2 − (n − 2)/2 + 1 detector channels can be read out, where n is even. Three types of multiplexing circuits were designed, implemented, and tested in combination with Micromegas detectors. Experimental results demonstrate that, for a multiplexing circuit with a factor of 8, the spatial resolution remains comparable to the direct readout method, while achieving a detection efficiency exceeding 94%. For a circuit with a multiplexing factor of 16, although the spatial resolution shows a slight degradation, the detection efficiency remains above 93.6%. These results demonstrate that the proposed multiplexing methods can significantly reduce the number of readout channels while maintaining an acceptable level of spatial resolution and detection efficiency. These findings highlight the potential of the proposed multiplexing techniques for applications in fields requiring high-resolution and cost-effective detector systems, such as cosmic-ray muon imaging.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 414-420
A Compact Readout Electronics Based on Current Amplifier for Micromegas Detector in Muon Imaging
Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high spatial resolution and large area. However, the large number of readout channels poses a challenge for electronics. In this paper, a compact front-end electronics (FEE) for reading Micromegas detectors is presented. The electronics use the commercial current-to-digital readout chip, ADAS1128, which integrates 128 current amplifiers for multi-channel charge measurement. After verifying the basic performance of the electronics, the energy resolution was obtained with a radioactive source. Furthermore, a muon imaging system prototype was set up and its spatial resolution was evaluated in a test with cosmic ray muons. The system prototype can reconstruct the boundaries of sufficiently massive objects with a size of 2 cm in a scattering imaging test.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 414-420
A Compact Readout Electronics Based on Current Amplifier for Micromegas Detector in Muon Imaging
Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high spatial resolution and large area. However, the large number of readout channels poses a challenge for electronics. In this paper, a compact front-end electronics (FEE) for reading Micromegas detectors is presented. The electronics use the commercial current-to-digital readout chip, ADAS1128, which integrates 128 current amplifiers for multi-channel charge measurement. After verifying the basic performance of the electronics, the energy resolution was obtained with a radioactive source. Furthermore, a muon imaging system prototype was set up and its spatial resolution was evaluated in a test with cosmic ray muons. The system prototype can reconstruct the boundaries of sufficiently massive objects with a size of 2 cm in a scattering imaging test.