Zezhou Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zezhou Yang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Jianjun Sun
School of Electrical Engineering, Wuhan University, Wuhan, China
2 shared publicationsXiaoming Zha
School of Electrical Engineering, Wuhan University, Wuhan, China
2 shared publicationsGangqiang Du
Department of power electronics, Dongfang Electronics Co., Ltd., Yantai, China
1 shared publicationGuozhou Xiao
Innovation Lab. School of Electrical Engineering, Wuhan University, Wuhan, P.R. China
1 shared publication- Jianjun Sun
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication Jiawen Fu
School of Electrical Engineering, Wuhan University, Wuhan, China
1 shared publication
Latest Publications
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (8) , 6437-6448
Dynamic Aggregation Modeling of Grid-Connected Inverters Using Hamilton's-Action-Based Coherent Equivalence
The high penetration of renewable energy generation (REG) systems influences the dynamics of power systems. Accurate transient simulations and dynamic models are indispensable for research on the dynamic behavior of REG systems. A large-scale REG system consisting of numerous grid-connected inverters consumes large amounts of computation time, so a dynamic aggregated model is needed for efficient simulation. The aggregated model established by coherent equivalence fits the detailed model well, and thus it is widely used in the aggregation of large-scale dynamic systems. Presently, the key challenge of the application of the coherent equivalence method is to identify inverters which have similar dynamic characteristics. The Hamilton principle expressed by Hamilton's action has a simple form and indicates the comprehensive dynamic characteristics of inverters. Thus, this paper proposes a coherent equivalence method of inverters based on Hamilton's action. The proposed method is applied to a wind farm of 16 permanent magnet synchronous generator (PMSG) -based wind turbines for demonstration. Compared with the existing equivalence method without considering coherency, the proposed method shows advantages in effectiveness and accuracy.
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (8) , 6437-6448
Dynamic Aggregation Modeling of Grid-Connected Inverters Using Hamilton's-Action-Based Coherent Equivalence
The high penetration of renewable energy generation (REG) systems influences the dynamics of power systems. Accurate transient simulations and dynamic models are indispensable for research on the dynamic behavior of REG systems. A large-scale REG system consisting of numerous grid-connected inverters consumes large amounts of computation time, so a dynamic aggregated model is needed for efficient simulation. The aggregated model established by coherent equivalence fits the detailed model well, and thus it is widely used in the aggregation of large-scale dynamic systems. Presently, the key challenge of the application of the coherent equivalence method is to identify inverters which have similar dynamic characteristics. The Hamilton principle expressed by Hamilton's action has a simple form and indicates the comprehensive dynamic characteristics of inverters. Thus, this paper proposes a coherent equivalence method of inverters based on Hamilton's action. The proposed method is applied to a wind farm of 16 permanent magnet synchronous generator (PMSG) -based wind turbines for demonstration. Compared with the existing equivalence method without considering coherency, the proposed method shows advantages in effectiveness and accuracy.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (1) , 538-549
Power Decoupling Control for Capacitance Reduction in Cascaded-H-Bridge-Converter-Based Regenerative Motor Drive Systems
A cascaded H-bridge (CHB) converter-based medium or high-voltage motor drive system, that consists of three single-phase CHB chains, may suffer a severe second-harmonic ripple power issue. Oversizing dc capacitors and using active power decoupling control with additional active or passive components are the two possible ways to address this issue, but this is achieved at the expense of increased system cost and complexity. This paper proposes a power decoupling control to tackle this issue without using any extra components for regenerative CHB-based converters. By introducing a set of negative-sequence decoupling currents to the front-end pulsewidth-modulated rectifier of each submodule, the second-harmonic ripple power can be removed from the submodule dc capacitors, and all the ripple power in the transformer core legs can be counteracted without affecting the magnetic flux and the grid current. The decoupling current is derived from the input and output measurements of the CHB converter. It gives the minimal increase of the modulation index and has no impacts on the input and output power quality. The effectiveness of the proposed control is verified in simulations and a 72-kW experimental prototype.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (1) , 538-549
Power Decoupling Control for Capacitance Reduction in Cascaded-H-Bridge-Converter-Based Regenerative Motor Drive Systems
A cascaded H-bridge (CHB) converter-based medium or high-voltage motor drive system, that consists of three single-phase CHB chains, may suffer a severe second-harmonic ripple power issue. Oversizing dc capacitors and using active power decoupling control with additional active or passive components are the two possible ways to address this issue, but this is achieved at the expense of increased system cost and complexity. This paper proposes a power decoupling control to tackle this issue without using any extra components for regenerative CHB-based converters. By introducing a set of negative-sequence decoupling currents to the front-end pulsewidth-modulated rectifier of each submodule, the second-harmonic ripple power can be removed from the submodule dc capacitors, and all the ripple power in the transformer core legs can be counteracted without affecting the magnetic flux and the grid current. The decoupling current is derived from the input and output measurements of the CHB converter. It gives the minimal increase of the modulation index and has no impacts on the input and output power quality. The effectiveness of the proposed control is verified in simulations and a 72-kW experimental prototype.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1511-1517
Individual DC voltage balancing method at zero current mode for cascaded H-bridge based static synchronous compensator
Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the existing individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. A comparison demonstrates the superiority of the novel method over other hardware based methods. Field test in a 10kV STATCOM confirms the performance of the proposed method.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1511-1517
Individual DC voltage balancing method at zero current mode for cascaded H-bridge based static synchronous compensator
Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the existing individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. A comparison demonstrates the superiority of the novel method over other hardware based methods. Field test in a 10kV STATCOM confirms the performance of the proposed method.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The Electromagnetic Nondestructive Testing Device of the wirerope-core transmission belt
The article put forward a new solution to monitoring the operation quality of the widely industrially applied wirerope-core transmission belt. Based on the Electromagnetic Nondestructive Testing Theory, the scheme analysed the essence of the wirerope-core transmission belt (hereinafter called as belt) testing, compared several electromagnetic testing methods. Then it fixed the experimental method of belt testing which is based on magnetic flux leakage testing, and designed the experimental testing device that enabled mutivariate and muti-angle variable study on nondestructive testing for belt. The article also provided a detailed introduction of the key components of the device. Finally there was a discussion about the prospect of the electromagnetic testing of belt.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The Electromagnetic Nondestructive Testing Device of the wirerope-core transmission belt
The article put forward a new solution to monitoring the operation quality of the widely industrially applied wirerope-core transmission belt. Based on the Electromagnetic Nondestructive Testing Theory, the scheme analysed the essence of the wirerope-core transmission belt (hereinafter called as belt) testing, compared several electromagnetic testing methods. Then it fixed the experimental method of belt testing which is based on magnetic flux leakage testing, and designed the experimental testing device that enabled mutivariate and muti-angle variable study on nondestructive testing for belt. The article also provided a detailed introduction of the key components of the device. Finally there was a discussion about the prospect of the electromagnetic testing of belt.