JSJianjun Sun

Jianjun Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianjun Sun has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Voltage Correction Virtual Admittance Control of STATCOM for Suppressing SSO in Wind Farms Under Weak Grid

    by Neng Peng, Jianjun Sun, YangDou Liang, Zhencheng Liang, Xiaoming Zha

    Sub-supersynchronous oscillation (SSO) often arises due to impedance interactions between wind farms (WFs) and weak grid, posing a significant threat to system stability. This article employs a sequence impedance model of a WF integrated with a static synchronous compensator (STATCOM) to investigate the mechanisms and characteristics of SSO under weak-grid conditions. The analysis reveals that reduced grid stiffness leads to a deterioration of system stability. To address this issue, a novel voltage correction virtual admittance (VCVA) control of STATCOM is proposed. The proposed scheme approximately introduces an equivalent passive admittance to reshape the sub-supersynchronous impedance of the WF, thereby providing sufficient damping for SSO suppression. Furthermore, a filter-free adaptive oscillation voltage extraction method based on constant voltage magnitude is developed to support the proposed VCVA control. The inherent DC offset between the extracted and actual oscillation voltage is automatically compensated by the STATCOM DC voltage control. Finally, both simulation and experimental results demonstrate that the proposed VCVA control provides enhanced damping performance and faster dynamic response compared with conventional filter-based damping schemes, validating its effectiveness in mitigating SSO in WFs connected to weak grid.

  • An Improved Reactance Control for Stability Enhancement of Grid-Forming Converter Based on Series-Regulated Branch

    by Minxuan Peng, Jianjun Sun, Neng Peng, Qionglin Li, Yi Wang, Xiaoming Zha, Yi Tang

    Virtual admittance control can enhance the stability of grid-forming converters in stiff grid. However, admittance control may induce a negative damping effect during reverse power operation, leading to system instability. Furthermore, under low dc-link voltage conditions, grid-forming converters implementing virtual admittance control are prone to over-modulation, resulting in control failure. To address these issues, this article proposes an improved reactance control that adjusts the set reactance to compensate for the deviation in equivalent reactance based on the frequency difference. Additionally, this article introduces a scheme that adopts a series of Boost circuits as a series-regulated branch to achieve the proposed reactance control. Theoretical analysis shows that the proposed method can achieve effective output of high damping voltage and positive damping enhancement of power across the entire range compared with the conventional virtual admittance and other voltage-based damping methods. Quantitative analysis and comparison are conducted using the Lyapunov direct method and the attraction region. The efficacy of the proposed method and the theoretical analysis are substantiated through prototype experiments.

  • A Novel Vibration Suppression Method for Permanent Magnet Synchronous Machine Based on Vibration-Reducing Winding

    by Yuanzhi Zhang, Yanshuo Jia, Li Fang, Rui Li, Pengye Wang, Yihang Luan, Jianjun Sun, Xiaoming Zha

    Low vibration is a critical performance metric for high-speed electrical machines, particularly in applications requiring stringent acoustic compliance. For integer-slot permanent magnet (PM) synchronous machines, the main sources of vibration under different speeds are the radial electromagnetic force harmonics of different frequencies, which are related to the rotor pole pairs and stator slots. In this article, a novel vibration suppression method concerning a vibration-reducing winding is proposed. The vibration-reducing winding injected with specific harmonic current can produce flux density of specific spatial–temporal properties which interact with that from the armature winding and PMs, producing the radial force which could offset the primary vibration-induced radial force harmonics. Compared with the conventional harmonic current injection method, the proposed method effectively suppresses the primary radial electromagnetic force of different frequencies over a wide speed range with small electric load. Finally, the proposed method is verified to reduce the vibration acceleration by over 60% via both FEA and experimental methods, while the electric load of the vibration-reducing winding is only 5.6% that of the armature winding.


  • Inertia Transmission Control of Full-Power Converter Variable-Speed Pumped Storage System for Grid Frequency Support

    by Kaihsun Chuang, Xiongfei Tao, Yihang Luan, Minxuan Peng, Jianjun Sun, Xiaoming Zha

    Full-power converter variable-speed pumped storage (FPC-VSPS) is a promising technique for flexible power regulation in small-scale distributed hydroelectric power plants. However, conventional vector control limits the synchronous motor of the FPC-VSPS from providing inertia support to the power grid. To overcome this limitation, this paper introduces an inertia transmission control for FPC-VSPS based on the concept of DC voltage synchronization. Firstly, the control incorporates the DC capacitor power equation into the GSC control. To enable inertia transmission from the FPC-VSPS synchronous machine, the DC capacitor dynamics are fed into both the speed and torque control of the MSC. Secondly, a torsion spring-rigid body equivalent model is introduced based on the inertia transmission process, analyzing the effects of physical parameters, control coefficients, and transmission delays on the inertia transmission performance. Theoretical analysis and simulation results reveal that the inherent physical differences and transmission delay have a negative impact on the effectiveness of the inertia transmission. Consequently, a DC capacitor design method based on inertia matching is proposed, accounting for the constraints of physical inertia matching, system stability, and operational security. Finally, simulations and experiments prove the necessity of inertia matching and verify the effectiveness of the proposed control to cope with frequency fluctuations in both pumping and generating modes.


  • Open Access

    Improved Sage–Husa Unscented Kalman Filter for Harmonic State Estimation in Distribution Grid

    by Peixuan Yu, Jianjun Sun

    In distribution grids with the large-scale integration of renewable energy sources and energy storage systems, power signals are often contaminated with time-varying noise and frequency deviation caused by low-frequency inertia. To achieve an accurate dynamic harmonic state estimate (HSE), a novel method based on an improved Sage–Husa unscented Kalman filter (ISHUKF) is proposed. Considering the frequency deviation, a nonlinear filter model for power signal is proposed, and a UKF is used to address the nonlinear estimation. A Sage–Husa noise estimator is incorporated to enhance the robustness of the UKF-based HSE against the time-varying noise. Additionally, the noise covariance of the Sage–Husa algorithm is modified to ensure the rapid convergence of the estimation. Then, the performance of the proposed method is validated using an IEEE 14-node system. Finally, the method is applied to evaluate the harmonic states of grid-connected inverter faults in real-world scenarios. The simulation and experiment results demonstrate that the proposed method provides an accurate dynamic HSE even in the presence of time-varying noise and frequency deviation.


  • Self-Excited Three-Port Converter for Photovoltaic Application With Stability Enhancement

    by Minxuan Peng, Jianjun Sun, Yi Liu, Xiaoming Zha, Meng Huang

    Reducing the impact of system voltage on the phase-locked loop in weak grid is an effective method to enhance the stability of grid-connected inverters. This article introduces a self-excited three-port converter topology, which utilizes a zigzag transformer to construct a small capacity series ac port on the dc–dc module of a two-stage photovoltaic grid-connected converter, achieving the goal of adjusting the grid voltage with its power and extending the degree of freedom in the grid-connected converter control. At the same time, an impedance compensation strategy based on the series ac port is proposed to suppress the impact of the grid-connected converter output circuit on the grid voltage and enhance the system stability on the time scale of the phase-locked loop. Theoretical analysis shows that the proposed converter topology and control method can significantly improve the stability so that the grid-connected converter can adapt to weak grid. Simulation and 1.6 kW prototype experiments prove that the proposed topology can effectively improve the stability of the converter system in weak grid with short-circuit ratio of 1.49 by compensating the impedance value of the power grid.


  • Mechanism and Solution of Inaccurate Perturbation Output of DC-AC Type IMU

    by Peijun Zhong, Jianjun Sun, Pan Yu, Yi Liu, Xiaoming Zha

    Impedance measurement unit (IMU) with injection of broadband perturbations is widely used to obtain grid and converter impedance. The accuracy of measured impedance and the power quality of the measured system rely on the amplitude control of the injected perturbations. However, the accuracy of output perturbation of IMU is lack of attention especially around the fundamental frequency of the measured system. In this brief, a three-phase DC-AC type IMU is introduced and the mechanism and solution of inaccurate perturbation output of the IMU is study. First, the DC-AC type IMU with PR current controllers, DC voltage controller and phase locked loop (PLL) is introduced. Next, the mechanism of inaccurate perturbation output is analysis, which is caused by the introduction of DC voltage ripple. Then, improved DC voltage control solutions with notch filter or delay filter are proposed to achieve the accurate control of single-frequency and multi-frequency perturbation current respectively. Finally, control hardware-in-the-loop experiment results are given to demonstrate and verify the effectiveness and feasibility of the proposed method.


  • Nonlinear Modeling and Stability Analysis of Grid-Tied Paralleled-Converters Systems Based on the Proposed Dual-Iterative Equal Area Criterion

    by Xilin Li, Zhen Tian, Xiaoming Zha, Pengfei Sun, Yufei Hu, Meng Huang, Jianjun Sun

    With the rapid development of distributed renewable energy generation and integration, stability issues of power converters systems have been widely studied in recent years. Many previous studies focus on the transient stability of a single converter connected to the weak grid. However, the nonlinear dynamics and stability mechanism of multiple converters systems remain unclear. In this article, a unified nonlinear model of the paralleled-converters system is established, which reveals the interactive power and interactive damping among multiple converters and the weak grid. To analyze the impacts of the interactive power and damping terms on system stability, a dual-iterative equal area criterion (DITEAC) is proposed with a dual-layer iterative calculation of the accelerating area and decelerating area. Compared with the previous studies, the proposed DITEAC method could deal with the nonlinear interactive damping and reduce the conservatism caused by the inequality scaling, which greatly improves the calculation accuracy of stability boundaries. The expansion feasibility of the proposed unified nonlinear model and DITEAC method to the N -converters system is fully discussed. Eventually, simulation and hardware-in-loop experiment results are presented to verify the effectiveness of the proposed method.


  • An Improved PRBS-Injection-Based Grid Impedance Measurement Method Considering Nonideal Grid Conditions

    by Peijun Zhong, Jianjun Sun, Lifeng Qu, Pan Yu, Xiaoming Zha

    The wide-bandwidth grid impedance measurement is a vital way in the resonance and stability analysis of the grid-tied system. However, the grid inevitably suffers from some nonideal conditions, such as voltage unbalance, frequency deviation, harmonics, and interharmonics, which has not been fully considered and well handled in grid impedance measurement using pseudorandom binary sequences. To address this challenge, a three-stage interpolation-based measurement method for grid impedance measurement is presented in this letter. The proposed method adopts the cubic spline interpolation to reconstruct the sampled signal and use the Hanning-window-based interpolated fast Fourier transform (FFT) to remove some undesired components to deal with the spectral leakage caused by the FFT. Simulation and hardware-in-the-loop experimental results are presented to demonstrate the performance of the proposed method.