ZCZane W. Cohick

Zane W. Cohick

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zane W. Cohick has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of 4.0 GHz RF Exposure Effects on Bioaerosols Containing Bovine Coronavirus

    by Zane W. Cohick, Brad W. Hoff, David Revelli, Jason Cox, Hammad Irshad, Amanda Snider, Ariel Arndt, Daniel A. Enderich, Jeremy W. McCohaha, James A. Schrock, et al.

    This study investigates the interaction between 4.0 GHz microwave radiation and bovine coronavirus (BCoV). Previous work by the authors at 5.6 GHz demonstrated mild (~74%) but statistically significant reductions in virus survival, attributed to a combination of thermal as well as non‐thermal effects, such as Structure‐Resonant Energy Transfer (SRET). This research aims to expand the frequency dataset to better elucidate the roles of thermal and non‐thermal effects in radio frequency (RF)‐induced viral inactivation. These experiments were performed in a waveguide containing a flowing aerosol stream and were limited to a single RF waveform: ∼2 μs square envelope, 4.0 GHz, 4.8 kHz repetition rate. Aerosol streams were exposed to RF electric field amplitudes in the range of 41.5 ± 5.2 kV/m. Under laminar flow conditions, 80% of the total collected aerosol stream spends 1.0 s or less in the RF exposure region. Analysis via TCID 50 assays revealed no statistically significant reduction in virus survival compared to controls, nor significant changes in data variance or standard deviation. Results align with prior observations that higher frequencies (~7–8 GHz) produce more pronounced inactivation effects, while lower frequencies exhibit reduced efficacy. The findings underscore the frequency dependence of microwave inactivation mechanisms and highlight the need for further studies at higher frequencies. Bioelectromagnetics. 00:00–00, 2025. © 2025 Bioelectromagnetics Society.


  • Laser requirements for the design of fast laser-driven semiconductor switches for THz and mm-waves

    by S. C. Schaub, Z. W. Cohick, B. W. Hoff

    A reduced parameter model of fast laser-driven semiconductor switches of THz and mm-waves has been developed. The model predicts peak reflectivity and minimum transmissivity of switches, showing good agreement with experimental data, while requiring fewer inputs than published models. This simplification facilitated a systematic survey of laser parameters required for efficient switching. Laser energy density requirements are presented as a function of laser wavelength, laser pulse width, switched frequency, reflection angle, and semiconductor material (silicon or gallium arsenide). Analytical expressions have been derived to explain the dependence of laser requirements on switch parameters and to derive practical minima of required laser energy density. Diffusion is shown to quickly negate the shallow absorption advantage of laser wavelengths shorter than about 500 nm in silicon or 800 nm in gallium arsenide. Decreasing laser pulse width, to a derived limit, and switching S-polarized THz or mm-wave signals are shown to be means of lowering required laser energy. This is an especially useful result for devices operating at high power levels or THz frequencies, where extended switches are used in quasioptical systems.


  • High temperature W-band complex permittivity measurements of thermally cycled ceramic-metal composites: AlN:Mo with 0.25 to 4.0 vol% Mo from 25 °C to 1000 °C in air

    by Zane W Cohick, Samuel C. Schaub, Brad W. Hoff, Frederick W. Dynys, Anthony E Baros, Maxwell Telmer, Haylie Orozco, Rachael O Grudt, Steven C. Hayden, Ian M. Rittersdorf, et al.

    An apparatus for measuring the W-band (75–110 GHz) complex permittivity of dielectrics at 1000 °C was developed. This apparatus allows for measurements at approximately twice the temperature of previously published high temperature free-space measurement systems while maintaining similar precision. Challenges were addressed related to high temperature measurements, including temperature uniformity, the accuracy of temperature measurements, and preventing temperature related changes to mm-wave measurement systems. The details of complex permittivity extraction from the measured S-parameters are discussed. Sources of error related to permittivity measurement and mathematical models were identified and are discussed in detail herein. Thermally-cycled, mm-wave absorbing, aluminum nitride ceramic composites containing varying levels of molybdenum additives were measured over the range of 25 °C–1000 °C. These measurements were compared to the same composites before thermal cycling. It was found that ceramic composites are largely stable after thermal cycling in terms of dielectric properties despite the presence of visible surface modifications.


  • Nonlinear transmission line-driven apparatus for short-pulse microwave exposure of aerosolized pathogens

    by Daniel A. Enderich, Brad W. Hoff, Michael Geiler, Anton Geiler, Casey Ottesen, Zane W. Cohick, Jeremy W. McConaha, Hugh H. Pohle, Matthew A. Franzi, P. David Lepell, et al.

    A system capable of exposing a flowing aerosol stream to short duration (2–4 ns), high-power RF waveforms is described. The system utilizes a C-band gyromagnetic nonlinear transmission line source having peak power outputs ranging as high as 80 kW at a center frequency of 4.2 GHz. RF electric field magnitudes of up to 280 kV/m ± 17% are achieved within the aerosol flow region of the RF exposure apparatus.


  • Apparatus for controlled microwave exposure of aerosolized pathogens

    by Brad W. Hoff, Jeremy W. McConaha, Zane W. Cohick, Matthew A. Franzi, Daniel A. Enderich, David Revelli, Jason Cox, Hammad Irshad, Hugh H. Pohle, Andreas Schmitt-Sody, et al.

    A set of three apparatus enabling RF exposure of aerosolized pathogens at four chosen frequencies (2.8 GHz, 4.0 GHz, 5.6 GHz, and 7.5 GHz) has been designed, simulated, fabricated, and tested. Each apparatus was intended to operate at high power without leakage of RF into the local environment and to be compact enough to fit within biocontainment enclosures required for elevated biosafety levels. Predictions for the range of RF electric field exposure, represented by the complex electric field vector magnitude, that an aerosol stream would be expected to encounter while passing through the apparatus are calculated for each of the chosen operating frequencies.


  • Weibull analysis of atmospheric pressure plasma generation and evidence for field emission in microwave split-ring resonators

    by Zane W Cohick, Benjamin Hall, D Wolfe, Michael T Lanagan, Douglas E Wolfe

    The generation of atmospheric pressure microplasmas using microwave resonators is promising for many applications due to the possibility of high electron densities and low electrode degradation. In particular, such plasmas may help enable reconfigurable metamaterials operating from GHz to THz. Since plasma metamaterials may require the generation of tens to hundreds of plasmas, it is important to find ways to reduce the power required for plasma breakdown. Here, we study gold and silver microwave split-ring resonators (SRRs) with a variety of materials near the interelectrode gap (Cu, CuO nanowires, aluminum oxide). We focus on those fabricated using a traditional thick film technique, screen-printing, and using fs- and ns-laser ablation. The use of laser ablation allows us to explore small interelectrode gap sizes (7–100 μ m) and the use of different lasers and laser parameters enables us to produce a variety of microstructures. We utilize Weibull statistics to examine breakdown in atmospheric pressure Ar with and without deep ultraviolet illumination of SRRs. Fabrication methods and materials are shown to influence both Q -factor of the SRRs and breakdown voltage independently. It is found that superior performance in terms of breakdown voltage and consistency in breakdown is related to Weibull modulus. The power requirement for breakdown varied as widely as an order of magnitude depending on fabrication method and material used for the SRRs. Furthermore, we consider the performance differences seen between various resonators and relate this to microstructure/material which suggests that field-emission may play a role in providing the seed electrons required for breakdown. This need for seed electrons appears to be especially important for gap sizes of 40 μ m and smaller.