Alex J. Drew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex J. Drew has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Kent N. Bachus
Affiliations Department of Orthopaedics, University of Utah, Salt Lake City, Utah, United States of America, Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, United States of America, Department of Veterans Affairs, University of Utah, Salt Lake City, Utah, United States of America
2 shared publications- Alexander Van Tongel
Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, Ghent, Belgium
1 shared publication - Andrew E. Anderson
Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112, USA; Scientific Computing and Imaging Institute, University of Utah, 72 S Central Campus Dr, Salt Lake City, UT 84112, USA; Department of Physical Therapy, University of Utah, 520 Wakara Way, Salt Lake City, UT 84108, USA
1 shared publication - Carolyn E. Taylor
Department of Orthopedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA
1 shared publication Carolyn Taylor
Department of Orthopaedics University of Utah Salt Lake City Utah USA
1 shared publication- Catherine Loc-Carrillo
Micro-Phage Laboratory, Department of Internal Medicine, University of Utah, Salt Lake City, UT 84132, USA
1 shared publication
Latest Publications
- 27 December 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (9) , 2065-2075
Use of computer tomography imaging for analyzing bone remodeling around a percutaneous osseointegrated implant
Osseointegration (OI) is being used for the direct skeletal attachment of prosthetic limbs using an intramedullary stem that extends percutaneously from the subject's residual limb. For this technology to be successful, bone ingrowth and remodeling around the implant must occur. Physicians need an effective way to assess bone remodeling to make informed treatment and rehabilitation decisions. Previous studies utilizing two-dimensional imaging x-ray as a tool to monitor bone-remodeling around OI devices have limitations. This work describes methodology that was developed utilizing computed tomography (CT) imaging as a tool for analyzing bone remodeling around a percutaneous OI implant. Six transfemoral amputees implanted with a Percutaneous Osseointegrated Prosthesis (POP) had CT scans taken of their residual femur at 6 and 52-weeks post-operatively. Three-dimensional femoral models were processed using custom MATLAB script to collect cortical and medullary morphology measurements. Morphology data from 6 and 52-week scans were compared to quantify bone remodeling around the POP implant. 52-weeks after implantation of the POP device, increases in cortical bone area and thickness were observed around the porous coated stem. Minimal changes were observed in the medullary canal parameters within the periprosthetic regions. This study successfully utilized CT imaging and 3D modeling techniques to analyze longitudinal data of bone remodeling around a transfemoral percutaneous implant. These methods have the potential to be used as a clinical tool for evaluating orthopedic implants in vivo. Data collected suggests that the POP device achieved the desired bone remodeling around the porous coated region of the implanted stem.
- 27 December 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (9) , 2065-2075
Use of computer tomography imaging for analyzing bone remodeling around a percutaneous osseointegrated implant
Osseointegration (OI) is being used for the direct skeletal attachment of prosthetic limbs using an intramedullary stem that extends percutaneously from the subject's residual limb. For this technology to be successful, bone ingrowth and remodeling around the implant must occur. Physicians need an effective way to assess bone remodeling to make informed treatment and rehabilitation decisions. Previous studies utilizing two-dimensional imaging x-ray as a tool to monitor bone-remodeling around OI devices have limitations. This work describes methodology that was developed utilizing computed tomography (CT) imaging as a tool for analyzing bone remodeling around a percutaneous OI implant. Six transfemoral amputees implanted with a Percutaneous Osseointegrated Prosthesis (POP) had CT scans taken of their residual femur at 6 and 52-weeks post-operatively. Three-dimensional femoral models were processed using custom MATLAB script to collect cortical and medullary morphology measurements. Morphology data from 6 and 52-week scans were compared to quantify bone remodeling around the POP implant. 52-weeks after implantation of the POP device, increases in cortical bone area and thickness were observed around the porous coated stem. Minimal changes were observed in the medullary canal parameters within the periprosthetic regions. This study successfully utilized CT imaging and 3D modeling techniques to analyze longitudinal data of bone remodeling around a transfemoral percutaneous implant. These methods have the potential to be used as a clinical tool for evaluating orthopedic implants in vivo. Data collected suggests that the POP device achieved the desired bone remodeling around the porous coated region of the implanted stem.
- Open Access
- 6 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0237179
Upper extremity prosthetic selection influences loading of transhumeral osseointegrated systems
Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13–33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12–15%, and axial pullout forces were 30–40% of the intact case (p≤0.001). The myoelectric hook and hand bending moments were 60–99%, torsional moments were 44–97%, and axial pullout forces were 62–101% of the intact case. The advanced prosthesis bending moments were 177–201%, torsional moments were 164–326%, and axial pullout forces were 133–185% of the intact case (p≤0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient’s desired terminal device when planning post-operative percutaneous OI rehabilitation and training.
- 6 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0237179
Open AccessUpper extremity prosthetic selection influences loading of transhumeral osseointegrated systems
Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13–33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12–15%, and axial pullout forces were 30–40% of the intact case (p≤0.001). The myoelectric hook and hand bending moments were 60–99%, torsional moments were 44–97%, and axial pullout forces were 62–101% of the intact case. The advanced prosthesis bending moments were 177–201%, torsional moments were 164–326%, and axial pullout forces were 133–185% of the intact case (p≤0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient’s desired terminal device when planning post-operative percutaneous OI rehabilitation and training.
- Open Access
- 6 April 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (5) , 1329-1338
Accuracy of 3D dual echo steady state (DESS) MR arthrography to quantify acetabular cartilage thickness
Purpose: To deploy and quantify the accuracy of 3D dual echo steady state (DESS) MR arthrography with hip traction to image acetabular cartilage. Clinical magnetic resonance imaging (MRI) sequences used to image hip cartilage often have reduced out‐of‐plane resolution and may lack adequate signal‐to‐noise to image cartilage.Materials and Methods: Saline was injected into four cadaver hips placed under traction. 3D DESS MRI scans were obtained before and after cores of cartilage were harvested from the acetabulum; the two MRIs were spatially aligned to reference core positions. The thickness of cartilage cores was measured under microscopy to serve as the reference standard. 3D reconstructions of cartilage and subchondral bone were generated using automatic and semiautomatic image segmentation. Cartilage thickness estimated from the 3D reconstructions was compared to physical measurements using Bland–Altman plots.Results: As revealed by the automatic segmentation mask, saline imbibed the joint space throughout the articulating surface, with the exception of the posteroinferior region in two hips. Locations where air bubbles were introduced and regions of suspected low density bone disrupted an otherwise smooth automatic segmentation mask. Automatic and semiautomatic segmentation yielded a bias ± repeatability coefficient (95% limits of agreement) of 0.10 ± 0.51 mm (−0.41 to 0.61 mm) and 0.06 ± 0.43 mm (−0.37 to 0.49 mm), respectively.Conclusion: Cartilage thickness can be estimated to within ∼0.5 mm of the physical value with 95% confidence using 3D reconstructions of 3D DESS MR arthrography images. Manual correction of the automatic segmentation mask may improve reconstruction accuracy. J. Magn. Reson. Imaging 2015;42:1329–1338.
- 6 April 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (5) , 1329-1338
Open AccessAccuracy of 3D dual echo steady state (DESS) MR arthrography to quantify acetabular cartilage thickness
Purpose: To deploy and quantify the accuracy of 3D dual echo steady state (DESS) MR arthrography with hip traction to image acetabular cartilage. Clinical magnetic resonance imaging (MRI) sequences used to image hip cartilage often have reduced out‐of‐plane resolution and may lack adequate signal‐to‐noise to image cartilage.Materials and Methods: Saline was injected into four cadaver hips placed under traction. 3D DESS MRI scans were obtained before and after cores of cartilage were harvested from the acetabulum; the two MRIs were spatially aligned to reference core positions. The thickness of cartilage cores was measured under microscopy to serve as the reference standard. 3D reconstructions of cartilage and subchondral bone were generated using automatic and semiautomatic image segmentation. Cartilage thickness estimated from the 3D reconstructions was compared to physical measurements using Bland–Altman plots.Results: As revealed by the automatic segmentation mask, saline imbibed the joint space throughout the articulating surface, with the exception of the posteroinferior region in two hips. Locations where air bubbles were introduced and regions of suspected low density bone disrupted an otherwise smooth automatic segmentation mask. Automatic and semiautomatic segmentation yielded a bias ± repeatability coefficient (95% limits of agreement) of 0.10 ± 0.51 mm (−0.41 to 0.61 mm) and 0.06 ± 0.43 mm (−0.37 to 0.49 mm), respectively.Conclusion: Cartilage thickness can be estimated to within ∼0.5 mm of the physical value with 95% confidence using 3D reconstructions of 3D DESS MR arthrography images. Manual correction of the automatic segmentation mask may improve reconstruction accuracy. J. Magn. Reson. Imaging 2015;42:1329–1338.