Jiří Dluhoš
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiří Dluhoš has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Tan Sui
School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH, UK
4 shared publications - Alexander M. Korsunsky
University of Oxford
2 shared publications - Adrian Cernescu
Attocube Systems AG, Eglfinger Weg 2, 85540 Munich, Germany
1 shared publication - Andrew J. London
United Kingdom Atomic Energy Authority, Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB, UK
1 shared publication Andrey Denisyuk
Global Applications, TESCAN ORSAY HOLDING, a.s., BRNO, République tchèque
1 shared publication- Bin Zhu
School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH, UK
1 shared publication
Latest Publications
- Open Access
- 27 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 530-551
AstroECP : towards more practical electron channeling contrast imaging
Electron channeling contrast imaging (ECCI) is a scanning electron microscope based technique which enables bulk-sample characterization of crystallographic defects ( e.g. dislocations, stacking faults, low-angle boundaries). Despite its potential, ECCI remains underused for quantitative defect analysis as compared with transmission electron microscope based methods. Here, we overcome barriers that limit the use of ECCI by optimizing signal-to-noise contrast and precise determination of the incident beam vector using calibrated, easy-to-use simulations and experimental selected-area electron channeling patterns (SA-ECPs). We introduce a systematic ECCI workflow, alongside a new open-source software tool ( AstroECP ), which includes calibration of stage tilting, SA-ECP field of view and the energy that forms the ECP/ECCI contrast using dynamical simulations. The functionality of this workflow is demonstrated with case studies that include threading dislocations in GaAs and the cross-validation of precession-based ECCI contrast, which is otherwise known as electron channeling orientation determination. To assist the reader, we also provide best-practice guidelines for ECCI implementation to promote high-resolution defect imaging in the scanning electron microscope.
- 27 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 530-551
Open AccessAstroECP : towards more practical electron channeling contrast imaging
Electron channeling contrast imaging (ECCI) is a scanning electron microscope based technique which enables bulk-sample characterization of crystallographic defects ( e.g. dislocations, stacking faults, low-angle boundaries). Despite its potential, ECCI remains underused for quantitative defect analysis as compared with transmission electron microscope based methods. Here, we overcome barriers that limit the use of ECCI by optimizing signal-to-noise contrast and precise determination of the incident beam vector using calibrated, easy-to-use simulations and experimental selected-area electron channeling patterns (SA-ECPs). We introduce a systematic ECCI workflow, alongside a new open-source software tool ( AstroECP ), which includes calibration of stage tilting, SA-ECP field of view and the energy that forms the ECP/ECCI contrast using dynamical simulations. The functionality of this workflow is demonstrated with case studies that include threading dislocations in GaAs and the cross-validation of precession-based ECCI contrast, which is otherwise known as electron channeling orientation determination. To assist the reader, we also provide best-practice guidelines for ECCI implementation to promote high-resolution defect imaging in the scanning electron microscope.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1315-1316
3D Multi-modal Elemental Characterization of Li-Ion Battery Components using SEM, EDS and ToF SIMS in the FIB-SEM Tomography
Latest A Scanning Electron Microscope equipped with a Focused Ion Beam (FIB-SEM) uniquely combined with a compact Time-of-Flight Secondary Ion Mass Spectrometer (ToF-SIMS) [ 1, 2] and a conventional microanalytical method of Energy Dispersive X-Ray Spectrometry (EDS) brings new possibilities in correlated microscopy and spectroscopy [ 3, 4]. Various materials are typically studied by a two-dimensional approach, based on the surface or cross-section analysis. This kind of characterization may be enough to represent basic compositional properties of the analyzed material but for some advanced cases does not provide complete information. For example, if there is an interest in analyzing surface or material inhomogeneity localization in volumetric objects or if a statistical micro and nanostructures evaluation has to be done, volume analysis is preferred. The basic volume analysis in FIB-SEM is based on FIB serial-sectioning and SEM imaging with topographical and material contrast capability. Simultaneous EDS mapping has also become a frequent requirement, providing qualitative information on elemental distribution. However, the information obtainable by EDS is limited to only elements emitting characteristic X-Ray spectra.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1315-1316
Open Access3D Multi-modal Elemental Characterization of Li-Ion Battery Components using SEM, EDS and ToF SIMS in the FIB-SEM Tomography
Latest A Scanning Electron Microscope equipped with a Focused Ion Beam (FIB-SEM) uniquely combined with a compact Time-of-Flight Secondary Ion Mass Spectrometer (ToF-SIMS) [ 1, 2] and a conventional microanalytical method of Energy Dispersive X-Ray Spectrometry (EDS) brings new possibilities in correlated microscopy and spectroscopy [ 3, 4]. Various materials are typically studied by a two-dimensional approach, based on the surface or cross-section analysis. This kind of characterization may be enough to represent basic compositional properties of the analyzed material but for some advanced cases does not provide complete information. For example, if there is an interest in analyzing surface or material inhomogeneity localization in volumetric objects or if a statistical micro and nanostructures evaluation has to be done, volume analysis is preferred. The basic volume analysis in FIB-SEM is based on FIB serial-sectioning and SEM imaging with topographical and material contrast capability. Simultaneous EDS mapping has also become a frequent requirement, providing qualitative information on elemental distribution. However, the information obtainable by EDS is limited to only elements emitting characteristic X-Ray spectra.
- Open Access
- 18 February 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (7) , eabl4592
A novel pathway for multiscale high-resolution time-resolved residual stress evaluation of laser-welded Eurofer97
The plasma-facing components of future fusion reactors, where the Eurofer97 is the primary structural material, will be assembled by laser-welding techniques. The heterogeneous residual stress induced by welding can interact with the microstructure, resulting in a degradation of mechanical properties and a reduction in joint lifetime. Here, a Xe + plasma focused ion beam with digital image correlation (PFIB-DIC) and nanoindentation is used to reveal the mechanistic connection between residual stress, microstructure, and microhardness. This study is the first to use the PFIB-DIC to evaluate the time-resolved multiscale residual stress at a length scale of tens of micrometers for laser-welded Eurofer97. A nonequilibrium microscale residual stress is observed, which contributes to the macroscale residual stress. The microhardness is similar for the fusion zone and heat-affected zone (HAZ), although the HAZ exhibits around ~30% tensile residual stress softening. The results provide insight into maintaining structural integrity for this critical engineering challenge.
- 18 February 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (7) , eabl4592
Open AccessA novel pathway for multiscale high-resolution time-resolved residual stress evaluation of laser-welded Eurofer97
The plasma-facing components of future fusion reactors, where the Eurofer97 is the primary structural material, will be assembled by laser-welding techniques. The heterogeneous residual stress induced by welding can interact with the microstructure, resulting in a degradation of mechanical properties and a reduction in joint lifetime. Here, a Xe + plasma focused ion beam with digital image correlation (PFIB-DIC) and nanoindentation is used to reveal the mechanistic connection between residual stress, microstructure, and microhardness. This study is the first to use the PFIB-DIC to evaluate the time-resolved multiscale residual stress at a length scale of tens of micrometers for laser-welded Eurofer97. A nonequilibrium microscale residual stress is observed, which contributes to the macroscale residual stress. The microhardness is similar for the fusion zone and heat-affected zone (HAZ), although the HAZ exhibits around ~30% tensile residual stress softening. The results provide insight into maintaining structural integrity for this critical engineering challenge.
- Open Access
- 3 June 2021
- Published by Wiley in Energy & Environmental Materials
- Vol. 5 (2) , 662-669
Degradation Diagnostics from the Subsurface of Lithium‐Ion Battery Electrodes
Despite the long‐established rocking‐chair theory of lithium‐ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe+ PFIB)‐based characterization technique to probe the cross‐sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in‐depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Through the quantitative analysis of the transition‐metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB‐based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high‐sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity‐fade observed in most LIBs.
- 3 June 2021
- Published by Wiley in Energy & Environmental Materials
- Vol. 5 (2) , 662-669
Open AccessDegradation Diagnostics from the Subsurface of Lithium‐Ion Battery Electrodes
Despite the long‐established rocking‐chair theory of lithium‐ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe+ PFIB)‐based characterization technique to probe the cross‐sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in‐depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Through the quantitative analysis of the transition‐metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB‐based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high‐sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity‐fade observed in most LIBs.
- Open Access
The Effect of a Taper Angle on Micro-Compression Testing of Mo-B-C Coatings
This research was devoted to studying the influence of the taper angle on the micro-compression of micro-pillars fabricated from near-amorphous and nanocrystalline Mo-B-C coatings. A series of micro-pillars with a taper angle between 4–14° was fabricated by focused ion beam technique. The deformation mechanism was found to be dependent on the taper and, also, on the crystallinity of the coating. In order to obtain correct values of yield strength and Young’s modulus, three empirical models of stress correction were experimentally tested, and the results were compared with nanoindentation measurements. It was shown that the average stress correction model provided comparable results with nanoindentation for the yield strength for taper angles up to ~10°. On the other hand, the average radius or area model gave the most precise results for Young’s modulus if the taper angle was <10°.
Open AccessThe Effect of a Taper Angle on Micro-Compression Testing of Mo-B-C Coatings
This research was devoted to studying the influence of the taper angle on the micro-compression of micro-pillars fabricated from near-amorphous and nanocrystalline Mo-B-C coatings. A series of micro-pillars with a taper angle between 4–14° was fabricated by focused ion beam technique. The deformation mechanism was found to be dependent on the taper and, also, on the crystallinity of the coating. In order to obtain correct values of yield strength and Young’s modulus, three empirical models of stress correction were experimentally tested, and the results were compared with nanoindentation measurements. It was shown that the average stress correction model provided comparable results with nanoindentation for the yield strength for taper angles up to ~10°. On the other hand, the average radius or area model gave the most precise results for Young’s modulus if the taper angle was <10°.
- Open Access
Fatigue Life of 7475-T7351 Aluminum After Local Severe Plastic Deformation Caused by Machining
The fatigue properties of thermo-mechanically treated and machined aluminum alloy 7475-T7351 have been studied. The applied advanced machining strategy induced intensive plastic deformation on the machined surface under defined cutting conditions. Therefore, a detailed study of 3D surface topography was performed. Advanced characterization of the material structure and electron back scattered diffraction mapping of selected chemical phases were performed, as well as energy dispersive X-ray analysis of the surface. Advanced mechanical properties of the material were investigated in situ with a scanning electron microscope that was equipped with a unique tensile fixture. The fatigue results confirmed an evident dispersion of the data, but the mechanism of crack nucleation was established. Fracture surface analysis showed that the cracks nucleated at the brittle secondary particles dispersed in the material matrix. The surface topography of samples that had been machined in wide range of cutting/deformation conditions by milling has not proved to be a decisive factor in terms of the fatigue behavior. The incoherent interface and decohesion between the alumina matrix and the brittle secondary phases proved to significantly affect the ultimate strength of the material. Tool engagement also affected the fatigue resistance of the material.
Open AccessFatigue Life of 7475-T7351 Aluminum After Local Severe Plastic Deformation Caused by Machining
The fatigue properties of thermo-mechanically treated and machined aluminum alloy 7475-T7351 have been studied. The applied advanced machining strategy induced intensive plastic deformation on the machined surface under defined cutting conditions. Therefore, a detailed study of 3D surface topography was performed. Advanced characterization of the material structure and electron back scattered diffraction mapping of selected chemical phases were performed, as well as energy dispersive X-ray analysis of the surface. Advanced mechanical properties of the material were investigated in situ with a scanning electron microscope that was equipped with a unique tensile fixture. The fatigue results confirmed an evident dispersion of the data, but the mechanism of crack nucleation was established. Fracture surface analysis showed that the cracks nucleated at the brittle secondary particles dispersed in the material matrix. The surface topography of samples that had been machined in wide range of cutting/deformation conditions by milling has not proved to be a decisive factor in terms of the fatigue behavior. The incoherent interface and decohesion between the alumina matrix and the brittle secondary phases proved to significantly affect the ultimate strength of the material. Tool engagement also affected the fatigue resistance of the material.
- Open Access
Structure-Function Correlative Microscopy of Peritubular and Intertubular Dentine
Peritubular dentine (PTD) and intertubular dentine (ITD) were investigated by 3D correlative Focused Ion Beam (FIB)-Scanning Electron Microscopy (SEM)-Energy Dispersive Spectroscopy (EDS) tomography, tapping mode Atomic Force Microscopy (AFM) and scattering-type Scanning Near-Field Optical Microscopy (s-SNOM) mapping. The brighter appearance of PTD in 3D SEM-Backscattered-Electron (BSE) imaging mode and the corresponding higher grey value indicate a greater mineral concentration in PTD (~160) compared to ITD (~152). However, the 3D FIB-SEM-EDS reconstruction and high resolution, quantitative 2D map of the Ca/P ratio (~1.8) fail to distinguish between PTD and ITD. This has been further confirmed using nanoscale 2D AFM map, which clearly visualised biopolymers and hydroxyapatite (HAp) crystallites with larger mean crystallite size in ITD (32 ± 8 nm) than that in PTD (22 ± 3 nm). Correlative microscopy reveals that the principal difference between PTD and ITD arises primarily from the nanoscale packing density of the crystallites bonded together by thin biopolymer, with moderate contribution from the chemical composition difference. The structural difference results in the mechanical properties variation that is described by the parabolic stiffness-volume fraction correlation function introduced here. The obtained results benefit a microstructure-based mechano-chemical model to simulate the chemical etching process that can occur in human dental caries and some of its treatments.
Open AccessStructure-Function Correlative Microscopy of Peritubular and Intertubular Dentine
Peritubular dentine (PTD) and intertubular dentine (ITD) were investigated by 3D correlative Focused Ion Beam (FIB)-Scanning Electron Microscopy (SEM)-Energy Dispersive Spectroscopy (EDS) tomography, tapping mode Atomic Force Microscopy (AFM) and scattering-type Scanning Near-Field Optical Microscopy (s-SNOM) mapping. The brighter appearance of PTD in 3D SEM-Backscattered-Electron (BSE) imaging mode and the corresponding higher grey value indicate a greater mineral concentration in PTD (~160) compared to ITD (~152). However, the 3D FIB-SEM-EDS reconstruction and high resolution, quantitative 2D map of the Ca/P ratio (~1.8) fail to distinguish between PTD and ITD. This has been further confirmed using nanoscale 2D AFM map, which clearly visualised biopolymers and hydroxyapatite (HAp) crystallites with larger mean crystallite size in ITD (32 ± 8 nm) than that in PTD (22 ± 3 nm). Correlative microscopy reveals that the principal difference between PTD and ITD arises primarily from the nanoscale packing density of the crystallites bonded together by thin biopolymer, with moderate contribution from the chemical composition difference. The structural difference results in the mechanical properties variation that is described by the parabolic stiffness-volume fraction correlation function introduced here. The obtained results benefit a microstructure-based mechano-chemical model to simulate the chemical etching process that can occur in human dental caries and some of its treatments.
- Open Access
- 20 December 2016
- Published by Wiley
- p. 267-268
Delayering of 14 nm Node Technology IC with Xe Plasma FIB
- 20 December 2016
- Published by Wiley
- p. 267-268
Open AccessDelayering of 14 nm Node Technology IC with Xe Plasma FIB
- Open Access
- 20 December 2016
- Published by Wiley
- p. 441-442
ColorSTEM ‐ A Novel STEM Detector for Advanced Materials Analysis in SEM
- 20 December 2016
- Published by Wiley
- p. 441-442
Open AccessColorSTEM ‐ A Novel STEM Detector for Advanced Materials Analysis in SEM
- 1 October 2015
- Published by Elsevier in Nano Energy
- Vol. 17, 254-260
Nanoscale chemical mapping of Li-ion battery cathode material by FIB-SEM and TOF-SIMS multi-modal microscopy
- 1 October 2015
- Published by Elsevier in Nano Energy
- Vol. 17, 254-260
Nanoscale chemical mapping of Li-ion battery cathode material by FIB-SEM and TOF-SIMS multi-modal microscopy