Manuel Ochoa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Manuel Ochoa has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Babak Ziaie
School of Electrical and Computer Engineering, Purdue University, USA
29 shared publicationsRahim Rahimi
School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
21 shared publicationsB. Ziaie
Purdue University, West Lafayette, USA
13 shared publications- Babak Ziaie
Faculty of Engineering and Computing, Atlantic Technological University, Sligo, Ireland
12 shared publications R. Rahimi
Purdue Univ. (United States)
10 shared publications- Rahim Rahimi
School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
9 shared publications
Latest Publications
- Open Access
- 18 May 2020
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 6 (1) , 1-16
Integrated sensing and delivery of oxygen for next-generation smart wound dressings
Chronic wounds affect over 6.5 million Americans and are notoriously difficult to treat. Suboptimal oxygenation of the wound bed is one of the most critical and treatable wound management factors, but existing oxygenation systems do not enable concurrent measurement and delivery of oxygen in a convenient wearable platform. Thus, we developed a low-cost alternative for continuous O2 delivery and sensing comprising of an inexpensive, paper-based, biocompatible, flexible platform for locally generating and measuring oxygen in a wound region. The platform takes advantage of recent developments in the fabrication of flexible microsystems including the incorporation of paper as a substrate and the use of a scalable manufacturing technology, inkjet printing. Here, we demonstrate the functionality of the oxygenation patch, capable of increasing oxygen concentration in a gel substrate by 13% (5 ppm) in 1 h. The platform is able to sense oxygen in a range of 5–26 ppm. In vivo studies demonstrate the biocompatibility of the patch and its ability to double or triple the oxygen level in the wound bed to clinically relevant levels.
- 18 May 2020
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 6 (1) , 1-16
Open AccessIntegrated sensing and delivery of oxygen for next-generation smart wound dressings
Chronic wounds affect over 6.5 million Americans and are notoriously difficult to treat. Suboptimal oxygenation of the wound bed is one of the most critical and treatable wound management factors, but existing oxygenation systems do not enable concurrent measurement and delivery of oxygen in a convenient wearable platform. Thus, we developed a low-cost alternative for continuous O2 delivery and sensing comprising of an inexpensive, paper-based, biocompatible, flexible platform for locally generating and measuring oxygen in a wound region. The platform takes advantage of recent developments in the fabrication of flexible microsystems including the incorporation of paper as a substrate and the use of a scalable manufacturing technology, inkjet printing. Here, we demonstrate the functionality of the oxygenation patch, capable of increasing oxygen concentration in a gel substrate by 13% (5 ppm) in 1 h. The platform is able to sense oxygen in a range of 5–26 ppm. In vivo studies demonstrate the biocompatibility of the patch and its ability to double or triple the oxygen level in the wound bed to clinically relevant levels.
- Open Access
- 23 July 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (39) , 22695-22704
Rapid prototyping of a novel and flexible paper based oxygen sensing patchviaadditive inkjet printing process
A novel and flexible oxygen sensing patch was successfully developed for wearable, industrial, food packaging, pharmaceutical and biomedical applications using a cost-efficient and rapid prototypable additive inkjet print manufacturing process. An oxygen sensitive ink was formulated by dissolving ruthenium dye and ethyl cellulose polymer in ethanol in a 1 : 1 : 98 (w/w/w) ratio. The patch was fabricated by depositing the oxygen sensitive ink on a flexible parchment paper substrate using an inkjet printing process. A maximum absorbance from 430 nm to 480 nm and a fluorescence of 600 nm was observed for the oxygen sensitive ink. The capability of the oxygen sensitive patch was investigated by measuring the fluorescence quenching lifetime of the printed dye for varying oxygen concentration levels. A fluorescence lifetime decay (τ) from ≈4 μs to ≈1.9 μs was calculated for the printed oxygen sensor patch, for oxygen concentrations varying from ≈5 mg L−1 to ≈25 mg L−1. A sensitivity of 0.11 μs mg L−1 and a correlation coefficient of 0.9315 was measured for the printed patches. The results demonstrated the feasibility of employing an inkjet printing process for the rapid prototyping of flexible and moisture resistant oxygen sensitive patches which facilitates a non-invasive method for monitoring oxygen and its concentration levels.
- 23 July 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (39) , 22695-22704
Open AccessRapid prototyping of a novel and flexible paper based oxygen sensing patchviaadditive inkjet printing process
A novel and flexible oxygen sensing patch was successfully developed for wearable, industrial, food packaging, pharmaceutical and biomedical applications using a cost-efficient and rapid prototypable additive inkjet print manufacturing process. An oxygen sensitive ink was formulated by dissolving ruthenium dye and ethyl cellulose polymer in ethanol in a 1 : 1 : 98 (w/w/w) ratio. The patch was fabricated by depositing the oxygen sensitive ink on a flexible parchment paper substrate using an inkjet printing process. A maximum absorbance from 430 nm to 480 nm and a fluorescence of 600 nm was observed for the oxygen sensitive ink. The capability of the oxygen sensitive patch was investigated by measuring the fluorescence quenching lifetime of the printed dye for varying oxygen concentration levels. A fluorescence lifetime decay (τ) from ≈4 μs to ≈1.9 μs was calculated for the printed oxygen sensor patch, for oxygen concentrations varying from ≈5 mg L−1 to ≈25 mg L−1. A sensitivity of 0.11 μs mg L−1 and a correlation coefficient of 0.9315 was measured for the printed patches. The results demonstrated the feasibility of employing an inkjet printing process for the rapid prototyping of flexible and moisture resistant oxygen sensitive patches which facilitates a non-invasive method for monitoring oxygen and its concentration levels.
- Open Access
- 21 June 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (34) , 19531-19538
Laser-treated glass platform for rapid wicking-driven transport and particle separation in bio microfluidics
In this work, we present a laser-based fabrication technique for direct patterning of micro-channels consisting of interconnected micro-cracks on soda-lime glass. Using a CO2 laser to deposit energy at a linear rate of 18.75 to 93.75 mJ mm−1, we were able to manipulate the micro-crack formation, while enabling rapid manufacturing and scalable production of cracked-glass microfluidic patterns on glass. At the higher end of the energy deposition rate (93.75 mJ mm−1), the laser fabricated microfluidic channels (1 mm wide and 20 mm long) had extremely fast wicking speeds (24.2 mm s−1, ×10 faster than filter paper) as a result of significant capillary action and laser-induced surface hydrophilization. At the lower end (18.75 mJ mm−1), 3–4 μm wide micro-cracked crevices resulted in an increased mesh/sieve density, hence, more efficiently filtering particle-laden liquid samples. The reproducibility tests revealed an averaged wicking speed of 10.6 ± 1.5 mm s−1 measured over 21 samples fabricated under similar conditions, similar to that of filter paper (∼85%). The micro-cracked channels exhibited a stable shelf life of at least 82 days with a wicking speed within 10–13 mm s−1.
- 21 June 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (34) , 19531-19538
Open AccessLaser-treated glass platform for rapid wicking-driven transport and particle separation in bio microfluidics
In this work, we present a laser-based fabrication technique for direct patterning of micro-channels consisting of interconnected micro-cracks on soda-lime glass. Using a CO2 laser to deposit energy at a linear rate of 18.75 to 93.75 mJ mm−1, we were able to manipulate the micro-crack formation, while enabling rapid manufacturing and scalable production of cracked-glass microfluidic patterns on glass. At the higher end of the energy deposition rate (93.75 mJ mm−1), the laser fabricated microfluidic channels (1 mm wide and 20 mm long) had extremely fast wicking speeds (24.2 mm s−1, ×10 faster than filter paper) as a result of significant capillary action and laser-induced surface hydrophilization. At the lower end (18.75 mJ mm−1), 3–4 μm wide micro-cracked crevices resulted in an increased mesh/sieve density, hence, more efficiently filtering particle-laden liquid samples. The reproducibility tests revealed an averaged wicking speed of 10.6 ± 1.5 mm s−1 measured over 21 samples fabricated under similar conditions, similar to that of filter paper (∼85%). The micro-cracked channels exhibited a stable shelf life of at least 82 days with a wicking speed within 10–13 mm s−1.
- Open Access
- 17 June 2019
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 5 (1) , 1-12
A mass-customizable dermal patch with discrete colorimetric indicators for personalized sweat rate quantification
In this paper, we present a disposable, colorimetric, user-friendly and mass-customizable dermal patch for chronological collection and discrete real-time in situ measurement of sweat secretion over a small area of skin. The patch consists of a laminated filter paper patterned into radially arranged channels/fingers with water-activated dyes at their tips. As channels are filled during perspiration, their tips change color once fully saturated, providing easily identifiable levels of water loss which in turn can be mapped to personal dehydration levels. The patch can be manufactured at low cost in a variety of sizes to allow hydration monitoring for individuals participating in activities under different conditions (intensity, temperature, humidity, etc.). Furthermore, we describe an analytical model that enables mass customization of such a flexible wearable system accommodating a broad range of sweat rates and volumes to generate patch designs that are personalized to an individual’s sweat rate, desired time of usage, and the temporal resolution of the required feedback. As a proof-of-concept demonstration, we characterized laser-fabricated patches that cover (7 cm × 5 cm) area of skin having various wicking materials, thicknesses (180–540 µm), and pore sizes (3–11 µm). Tests were conducted at various flow rates simulating different sweating intensities in the range of 1.5–15 mg/cm2/min. Experimental results for the case of a half-marathon runner targeting 90 min of usage and sweating at a rate of 1.5 mg/cm2/min indicated measurement accuracy of 98.3% when the patch is completely filled.
- 17 June 2019
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 5 (1) , 1-12
Open AccessA mass-customizable dermal patch with discrete colorimetric indicators for personalized sweat rate quantification
In this paper, we present a disposable, colorimetric, user-friendly and mass-customizable dermal patch for chronological collection and discrete real-time in situ measurement of sweat secretion over a small area of skin. The patch consists of a laminated filter paper patterned into radially arranged channels/fingers with water-activated dyes at their tips. As channels are filled during perspiration, their tips change color once fully saturated, providing easily identifiable levels of water loss which in turn can be mapped to personal dehydration levels. The patch can be manufactured at low cost in a variety of sizes to allow hydration monitoring for individuals participating in activities under different conditions (intensity, temperature, humidity, etc.). Furthermore, we describe an analytical model that enables mass customization of such a flexible wearable system accommodating a broad range of sweat rates and volumes to generate patch designs that are personalized to an individual’s sweat rate, desired time of usage, and the temporal resolution of the required feedback. As a proof-of-concept demonstration, we characterized laser-fabricated patches that cover (7 cm × 5 cm) area of skin having various wicking materials, thicknesses (180–540 µm), and pore sizes (3–11 µm). Tests were conducted at various flow rates simulating different sweating intensities in the range of 1.5–15 mg/cm2/min. Experimental results for the case of a half-marathon runner targeting 90 min of usage and sweating at a rate of 1.5 mg/cm2/min indicated measurement accuracy of 98.3% when the patch is completely filled.
- 4 June 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (13) , 2265-2274
A pH-regulated drug delivery dermal patch for targeting infected regions in chronic wounds
This work presents a low-cost, passive, flexible, polymeric pump for topical drug delivery which uses wound pH as a trigger for localized drug release. Its operation relies on a pH-responsive hydrogel actuator which swells when exposed to the alkaline pH of an infected wound. The pump enables slow release (−1) of aqueous anti-bacterial solution for up to 4 hours and sustains against up to 8 kPa of backpressure. Featuring a scalable layer-by-layer fabrication technique to expand the pump into a 2 × 2 array, the device can dispense 50 μl onto a 160 mm2 dermal coverage within 4 hours. Robustness tests show that when integrated within a medical adhesive, the device can be worn around the forearm and can withstand various daily activities (non-intensive) for up to 12 hours. In vitro experiments demonstrate a 58 times decrease of live P. aeruginosa after 24 hours of the pump assisted antibiotics treatment.
- 4 June 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (13) , 2265-2274
A pH-regulated drug delivery dermal patch for targeting infected regions in chronic wounds
This work presents a low-cost, passive, flexible, polymeric pump for topical drug delivery which uses wound pH as a trigger for localized drug release. Its operation relies on a pH-responsive hydrogel actuator which swells when exposed to the alkaline pH of an infected wound. The pump enables slow release (−1) of aqueous anti-bacterial solution for up to 4 hours and sustains against up to 8 kPa of backpressure. Featuring a scalable layer-by-layer fabrication technique to expand the pump into a 2 × 2 array, the device can dispense 50 μl onto a 160 mm2 dermal coverage within 4 hours. Robustness tests show that when integrated within a medical adhesive, the device can be worn around the forearm and can withstand various daily activities (non-intensive) for up to 12 hours. In vitro experiments demonstrate a 58 times decrease of live P. aeruginosa after 24 hours of the pump assisted antibiotics treatment.
- 17 September 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (42) , 36332-36341
Comparison of Direct and Indirect Laser Ablation of Metallized Paper for Inexpensive Paper-Based Sensors
In this work, we present a systematic study of laser processing of metallized papers (MP) as a simple and scalable alternative to conventional photolithography-based processes and printing technologies. Two laser processing methods are examined in terms of selectivity in removal of the conductive aluminum film (25 nm) of a MP substrate; these processes, namely direct and indirect laser ablation, operate at wavelengths of 1.06µm (Nd-YAG) and 10.6µm (CO2), respectively. Required threshold energy for each laser processing method were systematically measured, using electrical, optical and mechanical characterization techniques. The results of these investigations show that the removal of the metal coating using the indirect laser ablation (ILA) is only achieved through a partial etching of the paper substrate. The ILA process shows a narrow effective set of laser settings, capable of removing the metal film while not completely burning through the paper substrate. In contrast, direct laser ablation (DLA) show a more defined and selective removal of the aluminum layer without damaging the mechanical and natural fibular structure of the paper substrate. Finally, as a proof of concept, interdigitated capacitive moisture sensors were fabricated by means of DLA and ILA onto the MP substrate and their performance was assessed in the humidity range of 2–85% RH. The humidity sensitivity results show that the DLA sensors have a superior humidity sensing performance compared to the ILA sensors. The observed behavior is attributed to the higher water molecule absorption and induced capillary condensation within the intact cellulose network resulting from the DLA process (compared to the damaged one from the ILA process). DLA processes of MP should enable scalable production of low-cost, paper-based physical and chemical sensing systems for potential use in point-of-care diagnostics and food packaging.
- 17 September 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (42) , 36332-36341
Comparison of Direct and Indirect Laser Ablation of Metallized Paper for Inexpensive Paper-Based Sensors
In this work, we present a systematic study of laser processing of metallized papers (MP) as a simple and scalable alternative to conventional photolithography-based processes and printing technologies. Two laser processing methods are examined in terms of selectivity in removal of the conductive aluminum film (25 nm) of a MP substrate; these processes, namely direct and indirect laser ablation, operate at wavelengths of 1.06µm (Nd-YAG) and 10.6µm (CO2), respectively. Required threshold energy for each laser processing method were systematically measured, using electrical, optical and mechanical characterization techniques. The results of these investigations show that the removal of the metal coating using the indirect laser ablation (ILA) is only achieved through a partial etching of the paper substrate. The ILA process shows a narrow effective set of laser settings, capable of removing the metal film while not completely burning through the paper substrate. In contrast, direct laser ablation (DLA) show a more defined and selective removal of the aluminum layer without damaging the mechanical and natural fibular structure of the paper substrate. Finally, as a proof of concept, interdigitated capacitive moisture sensors were fabricated by means of DLA and ILA onto the MP substrate and their performance was assessed in the humidity range of 2–85% RH. The humidity sensitivity results show that the DLA sensors have a superior humidity sensing performance compared to the ILA sensors. The observed behavior is attributed to the higher water molecule absorption and induced capillary condensation within the intact cellulose network resulting from the DLA process (compared to the damaged one from the ILA process). DLA processes of MP should enable scalable production of low-cost, paper-based physical and chemical sensing systems for potential use in point-of-care diagnostics and food packaging.
- 8 August 2018
- Published by Wiley in Advanced Biosystems
- Vol. 2 (9)
Yeast Metabolic Response as an Indicator of Radiation Damage in Biological Tissue
Wearable radiation sensors for workers of radiation‐intensive industries provide a measure of radiation exposure but not of its effects on biological tissue. A biohybrid radiation sensing platform based on a new transduction mechanism for detecting biological radiation damage using the metabolic activity of a microorganism population is presented here. The sensor is a wearable, disposable, film‐type device fabricated on a paper substrate with yeast (Saccharomyces cerevisiae) cells patterned between two electrodes and used as a smart material. The device is sensitive to radiation when dry and is read by activating it with water. Yeast (S. cerevisiae) cells, that are exposed to ionizing radiation and subsequently allowed to ferment a glucose solution, exhibit an electrical conductivity that is lower than that of nonexposed yeast. The radiation damage to this microorganism is directly proportional to the measured impedance of the fermenting medium. An 18 × 18 mm2 and 0.57 mm thick sensors with ground yeast (3.09 mg cm−2 areal density filtered with a 50 µm mesh) shows a sensitivity of 4.5% Ω/Ω0decade‐rad upon exposure to Cs‐137. The minimum detectable dose (resolution) is 1 mrad. Fluorescence microscopy results suggest that it is primarily due to damaged membranes in the cell wall and mitochondria.
- 8 August 2018
- Published by Wiley in Advanced Biosystems
- Vol. 2 (9)
Yeast Metabolic Response as an Indicator of Radiation Damage in Biological Tissue
Wearable radiation sensors for workers of radiation‐intensive industries provide a measure of radiation exposure but not of its effects on biological tissue. A biohybrid radiation sensing platform based on a new transduction mechanism for detecting biological radiation damage using the metabolic activity of a microorganism population is presented here. The sensor is a wearable, disposable, film‐type device fabricated on a paper substrate with yeast (Saccharomyces cerevisiae) cells patterned between two electrodes and used as a smart material. The device is sensitive to radiation when dry and is read by activating it with water. Yeast (S. cerevisiae) cells, that are exposed to ionizing radiation and subsequently allowed to ferment a glucose solution, exhibit an electrical conductivity that is lower than that of nonexposed yeast. The radiation damage to this microorganism is directly proportional to the measured impedance of the fermenting medium. An 18 × 18 mm2 and 0.57 mm thick sensors with ground yeast (3.09 mg cm−2 areal density filtered with a 50 µm mesh) shows a sensitivity of 4.5% Ω/Ω0decade‐rad upon exposure to Cs‐137. The minimum detectable dose (resolution) is 1 mrad. Fluorescence microscopy results suggest that it is primarily due to damaged membranes in the cell wall and mitochondria.
- Top Cited Papers
Smart Bandage for Monitoring and Treatment of Chronic Wounds
Chronic wounds are a major health concern and they affect the lives of more than 25 million people in the United States. They are susceptible to infection and are the leading cause of nontraumatic limb amputations worldwide. The wound environment is dynamic, but their healing rate can be enhanced by administration of therapies at the right time. This approach requires real‐time monitoring of the wound environment with on‐demand drug delivery in a closed‐loop manner. In this paper, a smart and automated flexible wound dressing with temperature and pH sensors integrated onto flexible bandages that monitor wound status in real‐time to address this unmet medical need is presented. Moreover, a stimuli‐responsive drug releasing system comprising of a hydrogel loaded with thermo‐responsive drug carriers and an electronically controlled flexible heater is also integrated into the wound dressing to release the drugs on‐demand. The dressing is equipped with a microcontroller to process the data measured by the sensors and to program the drug release protocol for individualized treatment. This flexible smart wound dressing has the potential to significantly impact the treatment of chronic wounds.
Top Cited PapersSmart Bandage for Monitoring and Treatment of Chronic Wounds
Chronic wounds are a major health concern and they affect the lives of more than 25 million people in the United States. They are susceptible to infection and are the leading cause of nontraumatic limb amputations worldwide. The wound environment is dynamic, but their healing rate can be enhanced by administration of therapies at the right time. This approach requires real‐time monitoring of the wound environment with on‐demand drug delivery in a closed‐loop manner. In this paper, a smart and automated flexible wound dressing with temperature and pH sensors integrated onto flexible bandages that monitor wound status in real‐time to address this unmet medical need is presented. Moreover, a stimuli‐responsive drug releasing system comprising of a hydrogel loaded with thermo‐responsive drug carriers and an electronically controlled flexible heater is also integrated into the wound dressing to release the drugs on‐demand. The dressing is equipped with a microcontroller to process the data measured by the sensors and to program the drug release protocol for individualized treatment. This flexible smart wound dressing has the potential to significantly impact the treatment of chronic wounds.
- 8 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10639, 48
A manufacturable smart dressing with oxygen delivery and sensing capability for chronic wound management
Chronic non-healing wounds, impact over 6.5 million Americans, costs in excess of $25 billion to treat on an annual basis and its incidence is predicted to rise due to the prevalence of obesity and type-2 diabetes. One of the primary complications often associated with chronic wounds is the improper functionality of the peripheral vasculature to deliver O2-rich blood to the tissue which leads to wound hypoxia. Although hyperbaric oxygen therapy are widely used and accepted as an effective approach to bolster tissue O2 levels in hypoxic chronic wounds, most of such treatments require bulky equipment and often expose large areas of the body to unnecessarily elevated oxygen concentrations that can damage healthy tissue. In this paper, we present a smart low-cost wound dressing with integrated oxygen sensor and delivery for locally generating and delivering oxygen to selected hypoxic regions on the wound. The dressing is fabricated on a biocompatible water resistant/hydrophobic paper-based substrate with printed optical oxygen sensors and patterned catalytic oxygen generating regions that are connected to a flexible microfluidic systems. Oxygen generation occurs by flowing H2O2 through the channels and chemical decomposition at the catalyst printed regions on the paper substrate. The hydrophobic paper provides structural stability and flexibility while simultaneously offering printability, selective gaseous filtering, and physical/chemical protection. The fabrication process take advantage of scalable manufacturing technologies including laser processing, inkjet printing, and lamination.
- 8 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10639, 48
A manufacturable smart dressing with oxygen delivery and sensing capability for chronic wound management
Chronic non-healing wounds, impact over 6.5 million Americans, costs in excess of $25 billion to treat on an annual basis and its incidence is predicted to rise due to the prevalence of obesity and type-2 diabetes. One of the primary complications often associated with chronic wounds is the improper functionality of the peripheral vasculature to deliver O2-rich blood to the tissue which leads to wound hypoxia. Although hyperbaric oxygen therapy are widely used and accepted as an effective approach to bolster tissue O2 levels in hypoxic chronic wounds, most of such treatments require bulky equipment and often expose large areas of the body to unnecessarily elevated oxygen concentrations that can damage healthy tissue. In this paper, we present a smart low-cost wound dressing with integrated oxygen sensor and delivery for locally generating and delivering oxygen to selected hypoxic regions on the wound. The dressing is fabricated on a biocompatible water resistant/hydrophobic paper-based substrate with printed optical oxygen sensors and patterned catalytic oxygen generating regions that are connected to a flexible microfluidic systems. Oxygen generation occurs by flowing H2O2 through the channels and chemical decomposition at the catalyst printed regions on the paper substrate. The hydrophobic paper provides structural stability and flexibility while simultaneously offering printability, selective gaseous filtering, and physical/chemical protection. The fabrication process take advantage of scalable manufacturing technologies including laser processing, inkjet printing, and lamination.
- 29 June 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (2) , 432-445
Gradient-on-a-Chip with Reactive Oxygen Species Reveals Thresholds in the Nucleus Response of Cancer Cells Depending on the Matrix Environment
Oxidative stress-mediated cancer progression depends on exposure to reactive oxygen species (ROS) in the extracellular matrix (ECM). To study the impact of ROS levels on preinvasive breast cancer cells as a function of ECM characteristics, we created a gradient-on-a-chip in which H2O2 progressively mixes with the cell culture medium within connected microchannels and diffuses upward into the ECM of the open cell culture window. The device utilizes a paper-based microfluidic bifurcating mixer insert to prevent leakage and favor an even fluid distribution. The gradient was confirmed by measuring H2O2 catalyzed into oxygen, and increasing oxidative DNA damage and protective (AOP2) response were recorded in 2D and ECM-based 3D cell cultures. Interestingly, the impact of ROS on nuclear shape and size (annunciating phenotypical changes) was governed by the stiffness of the collagen I matrix, suggesting the existence of thresholds for the phenotypic response to microenvironmental chemical exposure depending on ECM conditions.
- 29 June 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (2) , 432-445
Gradient-on-a-Chip with Reactive Oxygen Species Reveals Thresholds in the Nucleus Response of Cancer Cells Depending on the Matrix Environment
Oxidative stress-mediated cancer progression depends on exposure to reactive oxygen species (ROS) in the extracellular matrix (ECM). To study the impact of ROS levels on preinvasive breast cancer cells as a function of ECM characteristics, we created a gradient-on-a-chip in which H2O2 progressively mixes with the cell culture medium within connected microchannels and diffuses upward into the ECM of the open cell culture window. The device utilizes a paper-based microfluidic bifurcating mixer insert to prevent leakage and favor an even fluid distribution. The gradient was confirmed by measuring H2O2 catalyzed into oxygen, and increasing oxidative DNA damage and protective (AOP2) response were recorded in 2D and ECM-based 3D cell cultures. Interestingly, the impact of ROS on nuclear shape and size (annunciating phenotypical changes) was governed by the stiffness of the collagen I matrix, suggesting the existence of thresholds for the phenotypic response to microenvironmental chemical exposure depending on ECM conditions.