Keren Shemtov-Yona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Keren Shemtov-Yona has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Rittel
Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
7 shared publications A. Dorogoy
Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
2 shared publicationsAdi Arieli
Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine Tel Aviv University Tel Aviv Israel
1 shared publicationD. Rittel
Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
1 shared publicationG. Haïat
CNRS, Laboratoire Modélisation et Simulation Multi-échelle, UMR CNRS 8202, 94010 Créteil Cedex, France
1 shared publication- Hilla Bohbot
Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
1 shared publication
Latest Publications
- 7 September 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 26 (2) , 289-298
The effect of contaminating media on the static and dynamic mechanical resilience of dental implant abutments' screws: In vitro study
Introduction: This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading.Methods: Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross‐sections of the abutment‐implant apparatus were examined to evaluate the abutment screw–abutment‐implant interface.Results: The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque‐angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX‐gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold‐welding/galling, post‐dynamic loading in these latter groups.Conclusions: The presence of lubrication/contamination media (CHX mouthwash/CHX‐gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant‐supported prosthetic long‐term stability.
- 7 September 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 26 (2) , 289-298
The effect of contaminating media on the static and dynamic mechanical resilience of dental implant abutments' screws: In vitro study
Introduction: This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading.Methods: Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross‐sections of the abutment‐implant apparatus were examined to evaluate the abutment screw–abutment‐implant interface.Results: The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque‐angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX‐gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold‐welding/galling, post‐dynamic loading in these latter groups.Conclusions: The presence of lubrication/contamination media (CHX mouthwash/CHX‐gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant‐supported prosthetic long‐term stability.
- Open Access
- 16 June 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (6) , e0253283
Quantitative assessment of the jawbone quality classification: A meta-analysis study
Aim: Bone quality is evaluated using bone density for qualitative classification, a characteristic that may be delicate to evaluate. Contemporary implantology that relies on modern measurement techniques, needs a more quantitative estimate of the bone quality. Materials and methods: PubMed and EMBASE databases were searched with no time restriction. Clinical and radiographic studies reporting on alveolar ridge dimensions and its parameters in different areas of the dentate and edentulous jaws were included. A meta-analysis was performed using random effect models to report a combined mean for alveolar ridge and its parameters. Meta regression statistical tests were performed in order to identify differences in those outcome parameters. Results: 30 studies were included. The majority of the selected studies (total of 27) used live human subjects and CBCT to analyze alveolar ridge dimensions and its parameters. Using the combined mean obtained from the meta-analysis, a typical portrait of the alveolar ridge was constructed, and a geometrically based quantitative bone classification proposed. The quantitative classification was found to match the existing qualitative classification. Conclusion: A geometry-based analysis was constructed that yields valuable insights on the bone type based on its components and on the dynamics of the dentate / edentulous states.
- 16 June 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (6) , e0253283
Open AccessQuantitative assessment of the jawbone quality classification: A meta-analysis study
Aim: Bone quality is evaluated using bone density for qualitative classification, a characteristic that may be delicate to evaluate. Contemporary implantology that relies on modern measurement techniques, needs a more quantitative estimate of the bone quality. Materials and methods: PubMed and EMBASE databases were searched with no time restriction. Clinical and radiographic studies reporting on alveolar ridge dimensions and its parameters in different areas of the dentate and edentulous jaws were included. A meta-analysis was performed using random effect models to report a combined mean for alveolar ridge and its parameters. Meta regression statistical tests were performed in order to identify differences in those outcome parameters. Results: 30 studies were included. The majority of the selected studies (total of 27) used live human subjects and CBCT to analyze alveolar ridge dimensions and its parameters. Using the combined mean obtained from the meta-analysis, a typical portrait of the alveolar ridge was constructed, and a geometrically based quantitative bone classification proposed. The quantitative classification was found to match the existing qualitative classification. Conclusion: A geometry-based analysis was constructed that yields valuable insights on the bone type based on its components and on the dynamics of the dentate / edentulous states.
- Open Access
Effect of Different Surface Treatments of Lithium Disilicate on the Adhesive Properties of Resin Cements
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.
Open AccessEffect of Different Surface Treatments of Lithium Disilicate on the Adhesive Properties of Resin Cements
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.
- 2 March 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 66 (1) , 65-74
Resonant frequency analysis of dental implants
Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.
- 2 March 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 66 (1) , 65-74
Resonant frequency analysis of dental implants
Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.
- Open Access
- 26 October 2018
- Published by Elsevier in Engineering Failure Analysis
- Vol. 96, 298-310
Fractographic characterization of fatigued zirconia dental implants tested in room air and saline solution
- 26 October 2018
- Published by Elsevier in Engineering Failure Analysis
- Vol. 96, 298-310
Open AccessFractographic characterization of fatigued zirconia dental implants tested in room air and saline solution
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 636-644
Fatigue failure of dental implants in simulated intraoral media
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 636-644
Fatigue failure of dental implants in simulated intraoral media
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 1-9
Random spectrum loading of dental implants: An alternative approach to functional performance assessment
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 1-9
Random spectrum loading of dental implants: An alternative approach to functional performance assessment
- Open Access
- 24 May 2016
- Published by MDPI AG in Dentistry Journal
- Vol. 4 (2) , 16
Fatigue of Dental Implants: Facts and Fallacies
Dental implants experience rare yet problematic mechanical failures such as fracture that are caused, most often, by (time-dependent) metal fatigue. This paper surveys basic evidence about fatigue failure, its identification and the implant’s fatigue performance during service. We first discuss the concept of dental implant fatigue, starting with a review of basic concepts related to this failure mechanism. The identification of fatigue failures using scanning electron microscopy follows, to show that this stage is fairly well defined. We reiterate that fatigue failure is related to the implant design and its surface condition, together with the widely varying service conditions. The latter are shown to vary to an extent that precludes devising average or representative conditions. The statistical nature of the fatigue test results is emphasized throughout the survey to illustrate the complexity in evaluating the fatigue behavior of dental implants from a design perspective. Today’s fatigue testing of dental implants is limited to ISO 14801 standard requirements, which ensures certification but does not provide any insight for design purposes due to its limited requirements. We introduce and discuss the random spectrum loading procedure as an alternative to evaluate the implant’s performance under more realistic conditions. The concept is illustrated by random fatigue testing in 0.9% saline solution.
- 24 May 2016
- Published by MDPI AG in Dentistry Journal
- Vol. 4 (2) , 16
Open AccessFatigue of Dental Implants: Facts and Fallacies
Dental implants experience rare yet problematic mechanical failures such as fracture that are caused, most often, by (time-dependent) metal fatigue. This paper surveys basic evidence about fatigue failure, its identification and the implant’s fatigue performance during service. We first discuss the concept of dental implant fatigue, starting with a review of basic concepts related to this failure mechanism. The identification of fatigue failures using scanning electron microscopy follows, to show that this stage is fairly well defined. We reiterate that fatigue failure is related to the implant design and its surface condition, together with the widely varying service conditions. The latter are shown to vary to an extent that precludes devising average or representative conditions. The statistical nature of the fatigue test results is emphasized throughout the survey to illustrate the complexity in evaluating the fatigue behavior of dental implants from a design perspective. Today’s fatigue testing of dental implants is limited to ISO 14801 standard requirements, which ensures certification but does not provide any insight for design purposes due to its limited requirements. We introduce and discuss the random spectrum loading procedure as an alternative to evaluate the implant’s performance under more realistic conditions. The concept is illustrated by random fatigue testing in 0.9% saline solution.
- Open Access
- 25 October 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-11
An Overview of the Mechanical Integrity of Dental Implants
With the growing use of dental implants, the incidence of implants’ failures grows. Late treatment complications, after reaching full osseointegration and functionality, include mechanical failures, such as fracture of the implant and its components. Those complications are deemed severe in dentistry, albeit being usually considered as rare, and therefore seldom addressed in the clinical literature. The introduction of dental implants into clinical practice fostered a wealth of research on their biological aspects. By contrast, mechanical strength and reliability issues were seldom investigated in the open literature, so that most of the information to date remains essentially with the manufacturers. Over the years, implants have gone through major changes regarding the material, the design, and the surface characteristics aimed at improving osseointegration. Did those changes improve the implants’ mechanical performance? This review article surveys the state-of-the-art literature about implants’ mechanical reliability, identifying the known causes for fracture, while outlining the current knowledge-gaps. Recent results on various aspects of the mechanical integrity and failure of implants are presented and discussed next. The paper ends by a general discussion and suggestions for future research, outlining the importance of mechanical considerations for the improvement of their future performance.
- 25 October 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-11
Open AccessAn Overview of the Mechanical Integrity of Dental Implants
With the growing use of dental implants, the incidence of implants’ failures grows. Late treatment complications, after reaching full osseointegration and functionality, include mechanical failures, such as fracture of the implant and its components. Those complications are deemed severe in dentistry, albeit being usually considered as rare, and therefore seldom addressed in the clinical literature. The introduction of dental implants into clinical practice fostered a wealth of research on their biological aspects. By contrast, mechanical strength and reliability issues were seldom investigated in the open literature, so that most of the information to date remains essentially with the manufacturers. Over the years, implants have gone through major changes regarding the material, the design, and the surface characteristics aimed at improving osseointegration. Did those changes improve the implants’ mechanical performance? This review article surveys the state-of-the-art literature about implants’ mechanical reliability, identifying the known causes for fracture, while outlining the current knowledge-gaps. Recent results on various aspects of the mechanical integrity and failure of implants are presented and discussed next. The paper ends by a general discussion and suggestions for future research, outlining the importance of mechanical considerations for the improvement of their future performance.
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 290-299
On the mechanical integrity of retrieved dental implants
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 290-299
On the mechanical integrity of retrieved dental implants