Jarrel Seah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jarrel Seah has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
Andy Kitchen
From the Department of Radiology, Alfred Hospital, 55 Commercial Rd, Melbourne, Victoria 3004, Australia (J.C.Y.S., A.F.D.); Department of Radiology, Royal Melbourne Hospital, Melbourne, Australia (J.S.N.T., F.G.); Melbourne, Australia (A.K.); and Department of Radiology, Melbourne University, Melbourne, Australia (F.G.).
3 shared publications- Michael Robert Milne
Annalise.ai, Sydney, NSW 2000, Australia
3 shared publications Catherine M Jones
Annalise-AI, Sydney, New South Wales, Australia
2 shared publicationsCyril Tang
Annalise-AI, Sydney, New South Wales, Australia
2 shared publications- Daniel Carrion
Monash Health
2 shared publications - Frank Gaillard
Department of Radiology, The Royal Melbourne Hospital, Parkville, Australia
2 shared publications
Latest Publications
- 1 July 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 316 (1) , e243378
Drafting the Future: The Dawn of AI Report Generation in Radiology
The ability of artificial intelligence systems such as multimodal large language models to generate draft reports from medical images holds transformative potential for radiology; however, robust validation frameworks remain essential for safety.
- 1 July 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 316 (1) , e243378
Drafting the Future: The Dawn of AI Report Generation in Radiology
The ability of artificial intelligence systems such as multimodal large language models to generate draft reports from medical images holds transformative potential for radiology; however, robust validation frameworks remain essential for safety.
- 3 January 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (5) , 2729-2738
Enhancing Radiographic Diagnosis: CycleGAN-Based Methods for Reducing Cast Shadow Artifacts in Wrist Radiographs
We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. We retrospectively collected 11,500 adult and paediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 750 radiographs with cast and 750 without cast. We extended the results from a previous study that employed CycleGAN by enhancing the model using a perceptual loss function and a self-attention layer. The CycleGAN model which incorporates a self-attention layer and perceptual loss function delivered a similar quantitative performance as the original model. This model was applied to images from 20 cases where the original reports recommended CT scanning or repeat radiographs without the cast, which were then evaluated by radiologists for qualitative assessment. The results demonstrated that the generated images could improve radiologists’ diagnostic confidence, in some cases leading to more decisive reports. Where available, the reports from follow-up imaging were compared with those produced by radiologists reading AI-generated images. Every report, except two, provided identical diagnoses as those associated with follow-up imaging. The ability of radiologists to perform robust reporting with downsampled AI-enhanced images is clinically meaningful and warrants further investigation. Additionally, radiologists were unable to distinguish AI-enhanced from unenhanced images. These findings suggest the cast suppression technique could be integrated as a tool to augment clinical workflows, with the potential benefits of reducing patient doses, improving operational efficiencies, reducing delays in diagnoses, and reducing the number of patient visits.
- 3 January 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (5) , 2729-2738
Enhancing Radiographic Diagnosis: CycleGAN-Based Methods for Reducing Cast Shadow Artifacts in Wrist Radiographs
We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. We retrospectively collected 11,500 adult and paediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 750 radiographs with cast and 750 without cast. We extended the results from a previous study that employed CycleGAN by enhancing the model using a perceptual loss function and a self-attention layer. The CycleGAN model which incorporates a self-attention layer and perceptual loss function delivered a similar quantitative performance as the original model. This model was applied to images from 20 cases where the original reports recommended CT scanning or repeat radiographs without the cast, which were then evaluated by radiologists for qualitative assessment. The results demonstrated that the generated images could improve radiologists’ diagnostic confidence, in some cases leading to more decisive reports. Where available, the reports from follow-up imaging were compared with those produced by radiologists reading AI-generated images. Every report, except two, provided identical diagnoses as those associated with follow-up imaging. The ability of radiologists to perform robust reporting with downsampled AI-enhanced images is clinically meaningful and warrants further investigation. Additionally, radiologists were unable to distinguish AI-enhanced from unenhanced images. These findings suggest the cast suppression technique could be integrated as a tool to augment clinical workflows, with the potential benefits of reducing patient doses, improving operational efficiencies, reducing delays in diagnoses, and reducing the number of patient visits.
- 1 January 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (1)
Tackling Algorithmic Bias and Promoting Transparency in Health Datasets: The STANDING Together Consensus Recommendations
- 1 January 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (1)
Tackling Algorithmic Bias and Promoting Transparency in Health Datasets: The STANDING Together Consensus Recommendations
- Open Access
Enhancing Radiographic Diagnosis: CycleGAN-based methods for reducing cast shadow artifacts in wrist radiographs
Objective: We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. Materials and Methods: We retrospectively collected 12000 adult and pediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 100 radiographs with cast and 100 without cast. We extended the results from a previous study that employed CycleGAN by enhancing the model using a perceptual loss function and a self-attention layer. Results: The CycleGAN model which incorporates a self-attention layer and perceptual loss function delivered the best quantitative performance. This model was applied to images from 20 cases where the original reports recommended CT scanning or repeat radiographs without the cast, which were then evaluated by radiologists for qualitative assessment. The results demonstrated that the generated images could improve radiologists’ diagnostic confidence, in some cases leading to more decisive reports. Where available, the reports from follow-up imaging were compared with those produced by radiologists reading AI-generated images. Every report, except two, provided identical diagnoses as those associated with follow-up imaging. The ability of radiologists to perform robust reporting with downsampled AI-enhanced images is clinically meaningful and warrants further investigation. Additionally, radiologists were unable to distinguish AI-enhanced from unenhanced images. Conclusion: These findings suggest the cast suppression technique could be integrated as a tool to augment clinical workflows, with the potential benefits of reducing patient doses, improving operational efficiencies, reducing delays in diagnoses, and reducing the number of patient visits.
Open AccessEnhancing Radiographic Diagnosis: CycleGAN-based methods for reducing cast shadow artifacts in wrist radiographs
Objective: We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. Materials and Methods: We retrospectively collected 12000 adult and pediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 100 radiographs with cast and 100 without cast. We extended the results from a previous study that employed CycleGAN by enhancing the model using a perceptual loss function and a self-attention layer. Results: The CycleGAN model which incorporates a self-attention layer and perceptual loss function delivered the best quantitative performance. This model was applied to images from 20 cases where the original reports recommended CT scanning or repeat radiographs without the cast, which were then evaluated by radiologists for qualitative assessment. The results demonstrated that the generated images could improve radiologists’ diagnostic confidence, in some cases leading to more decisive reports. Where available, the reports from follow-up imaging were compared with those produced by radiologists reading AI-generated images. Every report, except two, provided identical diagnoses as those associated with follow-up imaging. The ability of radiologists to perform robust reporting with downsampled AI-enhanced images is clinically meaningful and warrants further investigation. Additionally, radiologists were unable to distinguish AI-enhanced from unenhanced images. Conclusion: These findings suggest the cast suppression technique could be integrated as a tool to augment clinical workflows, with the potential benefits of reducing patient doses, improving operational efficiencies, reducing delays in diagnoses, and reducing the number of patient visits.
- Top Cited Papers
- 1 March 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (2) , e230205
Generative Large Language Models for Detection of Speech Recognition Errors in Radiology Reports
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. This study evaluated the ability of generative large language models (LLMs) to detect speech recognition errors in radiology reports. A dataset of 3,233 CT and MRI reports was assessed by radiologists for speech recognition errors. Errors were categorized as clinically significant or not clinically significant. Performances of five generative LLMs-GPT-3.5-turbo, GPT-4, text-davinci-003, Llama-v2-70B-chat, and Bard-were compared in detecting these errors, using manual error detection as the reference standard. Prompt engineering was used to optimize model performance. GPT-4 demonstrated high accuracy in detecting clinically significant errors (precision 76.9%, recall 100%, F1 86.9%) and not clinically significant errors (93.9% precision, 94.7% recall, 94.3% F1). Text-davinci-003 achieved F1 scores of 72% and 46.6% for clinically significant and not clinically significant errors, respectively. GPT-3.5-turbo obtained 59.1% and 32.2% F1 scores, while Llama-v2-70B-chat scored 72.8% and 47.7%. Bard showed the lowest accuracy, with F1 scores of 47.5% and 20.9%. GPT-4 effectively identified challenging errors of nonsense phrases and internally inconsistent statements. Longer reports, resident dictation, and overnight shifts were associated with higher error rates. In conclusion, advanced generative LLMs show potential for automatic detection of speech recognition errors in radiology reports. ©RSNA, 2024.
- 1 March 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (2) , e230205
Top Cited PapersGenerative Large Language Models for Detection of Speech Recognition Errors in Radiology Reports
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. This study evaluated the ability of generative large language models (LLMs) to detect speech recognition errors in radiology reports. A dataset of 3,233 CT and MRI reports was assessed by radiologists for speech recognition errors. Errors were categorized as clinically significant or not clinically significant. Performances of five generative LLMs-GPT-3.5-turbo, GPT-4, text-davinci-003, Llama-v2-70B-chat, and Bard-were compared in detecting these errors, using manual error detection as the reference standard. Prompt engineering was used to optimize model performance. GPT-4 demonstrated high accuracy in detecting clinically significant errors (precision 76.9%, recall 100%, F1 86.9%) and not clinically significant errors (93.9% precision, 94.7% recall, 94.3% F1). Text-davinci-003 achieved F1 scores of 72% and 46.6% for clinically significant and not clinically significant errors, respectively. GPT-3.5-turbo obtained 59.1% and 32.2% F1 scores, while Llama-v2-70B-chat scored 72.8% and 47.7%. Bard showed the lowest accuracy, with F1 scores of 47.5% and 20.9%. GPT-4 effectively identified challenging errors of nonsense phrases and internally inconsistent statements. Longer reports, resident dictation, and overnight shifts were associated with higher error rates. In conclusion, advanced generative LLMs show potential for automatic detection of speech recognition errors in radiology reports. ©RSNA, 2024.
- Open Access
- 9 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2317
Analysis of Line and Tube Detection Performance of a Chest X-ray Deep Learning Model to Evaluate Hidden Stratification
This retrospective case-control study evaluated the diagnostic performance of a commercially available chest radiography deep convolutional neural network (DCNN) in identifying the presence and position of central venous catheters, enteric tubes, and endotracheal tubes, in addition to a subgroup analysis of different types of lines/tubes. A held-out test dataset of 2568 studies was sourced from community radiology clinics and hospitals in Australia and the USA, and was then ground-truth labelled for the presence, position, and type of line or tube from the consensus of a thoracic specialist radiologist and an intensive care clinician. DCNN model performance for identifying and assessing the positioning of central venous catheters, enteric tubes, and endotracheal tubes over the entire dataset, as well as within each subgroup, was evaluated. The area under the receiver operating characteristic curve (AUC) was assessed. The DCNN algorithm displayed high performance in detecting the presence of lines and tubes in the test dataset with AUCs > 0.99, and good position classification performance over a subpopulation of ground truth positive cases with AUCs of 0.86–0.91. The subgroup analysis showed that model performance was robust across the various subtypes of lines or tubes, although position classification performance of peripherally inserted central catheters was relatively lower. Our findings indicated that the DCNN algorithm performed well in the detection and position classification of lines and tubes, supporting its use as an assistant for clinicians. Further work is required to evaluate performance in rarer scenarios, as well as in less common subgroups.
- 9 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2317
Open AccessAnalysis of Line and Tube Detection Performance of a Chest X-ray Deep Learning Model to Evaluate Hidden Stratification
This retrospective case-control study evaluated the diagnostic performance of a commercially available chest radiography deep convolutional neural network (DCNN) in identifying the presence and position of central venous catheters, enteric tubes, and endotracheal tubes, in addition to a subgroup analysis of different types of lines/tubes. A held-out test dataset of 2568 studies was sourced from community radiology clinics and hospitals in Australia and the USA, and was then ground-truth labelled for the presence, position, and type of line or tube from the consensus of a thoracic specialist radiologist and an intensive care clinician. DCNN model performance for identifying and assessing the positioning of central venous catheters, enteric tubes, and endotracheal tubes over the entire dataset, as well as within each subgroup, was evaluated. The area under the receiver operating characteristic curve (AUC) was assessed. The DCNN algorithm displayed high performance in detecting the presence of lines and tubes in the test dataset with AUCs > 0.99, and good position classification performance over a subpopulation of ground truth positive cases with AUCs of 0.86–0.91. The subgroup analysis showed that model performance was robust across the various subtypes of lines or tubes, although position classification performance of peripherally inserted central catheters was relatively lower. Our findings indicated that the DCNN algorithm performed well in the detection and position classification of lines and tubes, supporting its use as an assistant for clinicians. Further work is required to evaluate performance in rarer scenarios, as well as in less common subgroups.
- Open Access
- 24 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1134) , 20210979
Diagnostic accuracy of a commercially available deep-learning algorithm in supine chest radiographs following trauma
Objectives: Trauma chest radiographs may contain subtle and time-critical pathology. Artificial intelligence (AI) may aid in accurate reporting, timely identification and worklist prioritisation. However, few AI programs have been externally validated. This study aimed to evaluate the performance of a commercially available deep convolutional neural network – Annalise CXR V1.2 (Annalise.ai) – for detection of traumatic injuries on supine chest radiographs. Methods: Chest radiographs with a CT performed within 24 h in the setting of trauma were retrospectively identified at a level one adult trauma centre between January 2009 and June 2019. Annalise.ai assessment of the chest radiograph was compared to the radiologist report of the chest radiograph. Contemporaneous CT report was taken as the ground truth. Agreement with CT was measured using Cohen’s κ and sensitivity/specificity for both AI and radiologists were calculated. Results: There were 1404 cases identified with a median age of 52 (IQR 33–69) years, 949 males. AI demonstrated superior performance compared to radiologists in identifying pneumothorax (p = 0.007) and segmental collapse (p = 0.012) on chest radiograph. Radiologists performed better than AI for clavicle fracture (p = 0.002), humerus fracture (p < 0.0015) and scapula fracture (p = 0.014). No statistical difference was found for identification of rib fractures and pneumomediastinum. Conclusion: The evaluated AI performed comparably to radiologists in interpreting chest radiographs. Further evaluation of this AI program has the potential to enable it to be safely incorporated in clinical processes. Advances in knowledge: Clinically useful AI programs represent promising decision support tools.
- 24 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1134) , 20210979
Open AccessDiagnostic accuracy of a commercially available deep-learning algorithm in supine chest radiographs following trauma
Objectives: Trauma chest radiographs may contain subtle and time-critical pathology. Artificial intelligence (AI) may aid in accurate reporting, timely identification and worklist prioritisation. However, few AI programs have been externally validated. This study aimed to evaluate the performance of a commercially available deep convolutional neural network – Annalise CXR V1.2 (Annalise.ai) – for detection of traumatic injuries on supine chest radiographs. Methods: Chest radiographs with a CT performed within 24 h in the setting of trauma were retrospectively identified at a level one adult trauma centre between January 2009 and June 2019. Annalise.ai assessment of the chest radiograph was compared to the radiologist report of the chest radiograph. Contemporaneous CT report was taken as the ground truth. Agreement with CT was measured using Cohen’s κ and sensitivity/specificity for both AI and radiologists were calculated. Results: There were 1404 cases identified with a median age of 52 (IQR 33–69) years, 949 males. AI demonstrated superior performance compared to radiologists in identifying pneumothorax (p = 0.007) and segmental collapse (p = 0.012) on chest radiograph. Radiologists performed better than AI for clavicle fracture (p = 0.002), humerus fracture (p < 0.0015) and scapula fracture (p = 0.014). No statistical difference was found for identification of rib fractures and pneumomediastinum. Conclusion: The evaluated AI performed comparably to radiologists in interpreting chest radiographs. Further evaluation of this AI program has the potential to enable it to be safely incorporated in clinical processes. Advances in knowledge: Clinically useful AI programs represent promising decision support tools.
- Open Access
Assessment of the effect of a comprehensive chest radiograph deep learning model on radiologist reports and patient outcomes: a real-world observational study
Objectives Artificial intelligence (AI) algorithms have been developed to detect imaging features on chest X-ray (CXR) with a comprehensive AI model capable of detecting 124 CXR findings being recently developed. The aim of this study was to evaluate the real-world usefulness of the model as a diagnostic assistance device for radiologists. Design This prospective real-world multicentre study involved a group of radiologists using the model in their daily reporting workflow to report consecutive CXRs and recording their feedback on level of agreement with the model findings and whether this significantly affected their reporting. Setting The study took place at radiology clinics and hospitals within a large radiology network in Australia between November and December 2020. Participants Eleven consultant diagnostic radiologists of varying levels of experience participated in this study. Primary and secondary outcome measures Proportion of CXR cases where use of the AI model led to significant material changes to the radiologist report, to patient management, or to imaging recommendations. Additionally, level of agreement between radiologists and the model findings, and radiologist attitudes towards the model were assessed. Results Of 2972 cases reviewed with the model, 92 cases (3.1%) had significant report changes, 43 cases (1.4%) had changed patient management and 29 cases (1.0%) had further imaging recommendations. In terms of agreement with the model, 2569 cases showed complete agreement (86.5%). 390 (13%) cases had one or more findings rejected by the radiologist. There were 16 findings across 13 cases (0.5%) deemed to be missed by the model. Nine out of 10 radiologists felt their accuracy was improved with the model and were more positive towards AI poststudy. Conclusions Use of an AI model in a real-world reporting environment significantly improved radiologist reporting and showed good agreement with radiologists, highlighting the potential for AI diagnostic support to improve clinical practice.
Open AccessAssessment of the effect of a comprehensive chest radiograph deep learning model on radiologist reports and patient outcomes: a real-world observational study
Objectives Artificial intelligence (AI) algorithms have been developed to detect imaging features on chest X-ray (CXR) with a comprehensive AI model capable of detecting 124 CXR findings being recently developed. The aim of this study was to evaluate the real-world usefulness of the model as a diagnostic assistance device for radiologists. Design This prospective real-world multicentre study involved a group of radiologists using the model in their daily reporting workflow to report consecutive CXRs and recording their feedback on level of agreement with the model findings and whether this significantly affected their reporting. Setting The study took place at radiology clinics and hospitals within a large radiology network in Australia between November and December 2020. Participants Eleven consultant diagnostic radiologists of varying levels of experience participated in this study. Primary and secondary outcome measures Proportion of CXR cases where use of the AI model led to significant material changes to the radiologist report, to patient management, or to imaging recommendations. Additionally, level of agreement between radiologists and the model findings, and radiologist attitudes towards the model were assessed. Results Of 2972 cases reviewed with the model, 92 cases (3.1%) had significant report changes, 43 cases (1.4%) had changed patient management and 29 cases (1.0%) had further imaging recommendations. In terms of agreement with the model, 2569 cases showed complete agreement (86.5%). 390 (13%) cases had one or more findings rejected by the radiologist. There were 16 findings across 13 cases (0.5%) deemed to be missed by the model. Nine out of 10 radiologists felt their accuracy was improved with the model and were more positive towards AI poststudy. Conclusions Use of an AI model in a real-world reporting environment significantly improved radiologist reporting and showed good agreement with radiologists, highlighting the potential for AI diagnostic support to improve clinical practice.
- Open Access
Do comprehensive deep learning algorithms suffer from hidden stratification? A retrospective study on pneumothorax detection in chest radiography
Objectives To evaluate the ability of a commercially available comprehensive chest radiography deep convolutional neural network (DCNN) to detect simple and tension pneumothorax, as stratified by the following subgroups: the presence of an intercostal drain; rib, clavicular, scapular or humeral fractures or rib resections; subcutaneous emphysema and erect versus non-erect positioning. The hypothesis was that performance would not differ significantly in each of these subgroups when compared with the overall test dataset. Design A retrospective case–control study was undertaken. Setting Community radiology clinics and hospitals in Australia and the USA. Participants A test dataset of 2557 chest radiography studies was ground-truthed by three subspecialty thoracic radiologists for the presence of simple or tension pneumothorax as well as each subgroup other than positioning. Radiograph positioning was derived from radiographer annotations on the images. Outcome measures DCNN performance for detecting simple and tension pneumothorax was evaluated over the entire test set, as well as within each subgroup, using the area under the receiver operating characteristic curve (AUC). A difference in AUC of more than 0.05 was considered clinically significant. Results When compared with the overall test set, performance of the DCNN for detecting simple and tension pneumothorax was statistically non-inferior in all subgroups. The DCNN had an AUC of 0.981 (0.976–0.986) for detecting simple pneumothorax and 0.997 (0.995–0.999) for detecting tension pneumothorax. Conclusions Hidden stratification has significant implications for potential failures of deep learning when applied in clinical practice. This study demonstrated that a comprehensively trained DCNN can be resilient to hidden stratification in several clinically meaningful subgroups in detecting pneumothorax.
Open AccessDo comprehensive deep learning algorithms suffer from hidden stratification? A retrospective study on pneumothorax detection in chest radiography
Objectives To evaluate the ability of a commercially available comprehensive chest radiography deep convolutional neural network (DCNN) to detect simple and tension pneumothorax, as stratified by the following subgroups: the presence of an intercostal drain; rib, clavicular, scapular or humeral fractures or rib resections; subcutaneous emphysema and erect versus non-erect positioning. The hypothesis was that performance would not differ significantly in each of these subgroups when compared with the overall test dataset. Design A retrospective case–control study was undertaken. Setting Community radiology clinics and hospitals in Australia and the USA. Participants A test dataset of 2557 chest radiography studies was ground-truthed by three subspecialty thoracic radiologists for the presence of simple or tension pneumothorax as well as each subgroup other than positioning. Radiograph positioning was derived from radiographer annotations on the images. Outcome measures DCNN performance for detecting simple and tension pneumothorax was evaluated over the entire test set, as well as within each subgroup, using the area under the receiver operating characteristic curve (AUC). A difference in AUC of more than 0.05 was considered clinically significant. Results When compared with the overall test set, performance of the DCNN for detecting simple and tension pneumothorax was statistically non-inferior in all subgroups. The DCNN had an AUC of 0.981 (0.976–0.986) for detecting simple pneumothorax and 0.997 (0.995–0.999) for detecting tension pneumothorax. Conclusions Hidden stratification has significant implications for potential failures of deep learning when applied in clinical practice. This study demonstrated that a comprehensively trained DCNN can be resilient to hidden stratification in several clinically meaningful subgroups in detecting pneumothorax.
- Open Access
- 28 October 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-7
CLiP, catheter and line position dataset
Correct catheter position is crucial to ensuring appropriate function of the catheter and avoid complications. This paper describes a dataset consisting of 50,612 image level and 17,999 manually labelled annotations from 30,083 chest radiographs from the publicly available NIH ChestXRay14 dataset with manually annotated and segmented endotracheal tubes (ETT), nasoenteric tubes (NET) and central venous catheters (CVCs).
- 28 October 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-7
Open AccessCLiP, catheter and line position dataset
Correct catheter position is crucial to ensuring appropriate function of the catheter and avoid complications. This paper describes a dataset consisting of 50,612 image level and 17,999 manually labelled annotations from 30,083 chest radiographs from the publicly available NIH ChestXRay14 dataset with manually annotated and segmented endotracheal tubes (ETT), nasoenteric tubes (NET) and central venous catheters (CVCs).