DGDimitry Ginzburg

Dimitry Ginzburg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dimitry Ginzburg has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • RECENT DEVELOPMENTS IN COMPUTERISED ANALYSIS OF THERMOLUMINESCENCE GLOW CURVES: SOFTWARE CODES, MECHANISMS AND DOSIMETRIC APPLICATIONS

    by Y S Horowitz, L Oster, G Reshes, D Nemirovsky, D Ginzburg, S Biderman, Y Bokobza, M Sterenberg, I Eliyahu

    The computerised deconvolution of thermoluminescence glow curves into component glow peaks is discussed in detail with special emphasis on advances of the subject post 2013. A plethora of computer codes have been developed using models based on first-order kinetics, second-orders kinetics, interactive traps and continuous distributions of activation energies. The glow curves of several materials are displayed and discussed along with new and improved dosimetric applications:precision effects of heating rate, heavy charged particles, mixed field α/ϒ dosimetry, fading and dose–response linearity. Finally recommendations are made for future efforts.


  • SEARCH FOR EXPERIMENTAL EVIDENCE OF DOSE-RATE AND WALL SCATTERING EFFECTS IN THE THERMOLUMINESCENCE RESPONSE OF LIF:MG,TI (TLD-100)

    by Dimitry Ginzburg, Ilan Eliyahu, Nigel Spooner, Matan Sterenberg, Galina Reshes, Alex Shapiro, Shlomo Biderman, Beny Herman, Yossi Assor, Dimitry Nemirovsky, et al.

    An experimental investigation into the possibility of dose-rate effects and wall scatter in the thermoluminescent response of LiF:Mg,Ti (TLD-100) was carried out. The investigation was motivated by theoretical simulations predicting the possible presence of dose-rate effects coupled with the lack of detailed experimental studies. The dose rate was varied by changing the source to sample distance, by the use of attenuators, sources of 137Cs of various activities, filtration and the construction of identical geometrical irradiators of Teflon and stainless steel. Four levels of dose in the linear dose response region were studied at 10−2 Gy, 1.5 × 10−2 Gy, 0.1 Gy and 0.5 Gy to avoid complications in interpretation due to supralinearity above 1 Gy. At the dose of 1.5 × 10−2 Gy, the dose rate was varied by five orders of magnitude from 4.9 × 10−3 Gy s−1 to 4.9 × 10−8 Gy s−1. At the other levels of dose, a one to two orders of magnitude in dose rate was achieved. Within the measurement uncertainty of 5–10%, no dose-rate effects were observed in any of the experimental measurements and no changes in the shape of the glow curve were observed. The maximum wall scatter effect (Teflon to stainless steel) was measured at ~8% within the experimental uncertainty and well below expectations. The results are encouraging with respect to the accurate and reproducible use of LiF:Mg,Ti under various experimental conditions of irradiation.


  • INVESTIGATION OF THE TL CHARACTERISTICS OF COMPOSITE PEAK 5 IN THE GLOW CURVE OF LIF:MG,TI (TLD-100) USING NATURALLY AND FURNACE-COOLED SAMPLES FOLLOWING THE 400°C PRE-IRRADIATION ANNEAL

    by Ilan Eliyahu, Galina Reshes, Alex Shapiro, Shlomo Biderman, Leonid Oster, Dimitry Nemirovsky, Matan Sterenberg, Dimitry Ginzburg, Yigal Shalom Horowitz, Benny Herman, et al.

    The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.


  • THE UNIFIED INTERACTION MODEL: SIMULATIONS OF TL DOSE RESPONSE AND EXPERIMENTAL VERIFICATION OF INTENDED DOSE RESPONSE LINEARITY BY POSTIRRADIATION PHOTON EXCITATION

    by Dimitry Ginzburg, Leonid Oster, Shlomo Biderman, Galina Reshes, Ilan Eliyahu

    The Unified Interaction Model (UNIM) simulates the linear/supralinear dose response of the glow peaks of LiF:Mg,Ti (TLD-100) and other thermoluminescent materials and the dependence of the supralinearity on photon/electron energy. The UNIM is based on the radiation action of spatially correlated trapping centres (TCs) and luminescent centres (LCs), which results in localised (geminate) electron/hole recombination by quantum mechanical tunnelling. The linear dose response is mainly attributed to geminate recombination. UNIM simulations of the dose response of glow peak 5 in LiF:Mg,Ti following 500 and 8 keV electron/photon irradiation are discussed. In addition, simulations of postirradiation photo-excitation that redistribute the electrons and holes in the various TCs and LCs are demonstrated to extend the region of linear dose response and reduce the supralinearity. Experimental verification of dose–response linearity for levels of dose ≤30 Gy following both 3.65 and 5 eV photon excitation is presented.


  • MANIPULATION OF THE DOSE–RESPONSE OF COMPOSITE GLOW PEAK 5 IN THE THERMOLUMINESCENCE OF LiF:Mg,Ti (TLD-100) VIA OPTICAL EXCITATION POST-IRRADIATION: POTENTIAL FOR IMPROVED DOSE–RESPONSE LINEARITY BEYOND 1 Gy

    by D Ginzburg, L Oster, I Eliyahu, G Reshes, S Biderman, Y S Horowitz

    Many dosimetric applications and especially those involved in clinical dosimetry are hampered by the supralinearity of TLD-100 which begins at a level of dose of 1 Gy. This research investigates the effect of optical excitation following irradiation on the dose–response. It is expected that this will lead to a more linear dose–response, however, irrespective of the hoped-for linearity, the theoretical/kinetic simulations of the effect of optical excitation will further enhance our understanding of the thermoluminescence mechanisms, especially the role of spatially correlated trapping and luminescent centers. In the following, the various stages carried out in these investigations are discussed and preliminary results presented.


  • Development of a Thin, Double-Sided Alpha/Beta Detector for Surface-Contamination Measurement

    by Y. Ifergan, S. Dadon, A. Ocherashvili, I. Israelashvili, Y. Yehuda-Zada, D. Smadja, L. Carmel, Y. Knafo, D. Ginzburg, A. Osovizky, et al.

    Low-level radioactive surface-contamination measurements require lightweight, large-area, and high-efficiency detectors. In the previous work, we utilized wavelength shifting (WLS) fibers, coupled to a beta-sensitive plastic scintillator (PS) layer on one side, and to an alpha-sensitive ZnS(Ag) layer on both sides, for detecting both alpha and beta particles. In this work, the main goal was to improve the light collection (maximizing the number of photons reaching the PMT) by optimizing the WLS fibers structure, for getting better signal-to-noise ratio and to minimize the low-energy threshold of the detector. In most cases, improving the light collection mostly influenced the detector resolution. In our case, improving the light collection will improve the detection efficiency by ability to detect more events at low-energy spectrum, which is limited by the noise level. Aiming to improve the scintillation light-collection efficiency, we investigated and compared four different detector configurations. Two of them described in the previous work presents utilization of WLS fibers, with different diameters ( 1 mmφ, 1.5 mmφ), coupled on the PS. Two other configurations present utilization of WLS fibers ( 1.5 mmφ) installed into a flat groove on the PS layer, while in one configuration we utilized straight WLS fibers and in the other we utilized bent WLS fibers. It was found that the utilization of WLS fibers in bent configuration gives the highest light-collection efficiency. Additionally, there is improved light collection achieved by using WLS fibers with wider diameter ( 1.5 mmφ), which maximizes the capture fraction. Additionally, since ZnS(Ag) and PS have different decay times (200 ns and 2.4 ns, respectively), we were able to separate alpha from beta events. An algorithm script was developed to calculate the full width at half maximum (FWHM) of each pulse and a histogram was generated of the FWHM values for the pulse shape discrimination (PSD). Efficient PSD was achieved for alpha energies above 100 keV with figure of merit (FOM) of 1.92. GEANT4 simulation was carried out and compared with experimental results. The results of both were matched, showed that the light-collection efficiency from the bent WLS fibers configuration was the best. The simulation results and the experiments, including full description of the detector structure, ionization stage, and the WLS light collection, are presented.