Tiantian Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tiantian Guo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Bin Feng
Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
6 shared publications - Longtu Chen
University of Connecticut
5 shared publications Sharareh Emadi
Department of Biomedical Engineering, University of Connecticut, CT 06269, USA
2 shared publications- Sheikh Jawad Ilham
School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA, USA
2 shared publications - Ananth Kamath
Department of Chemistry and the James Franck Institute, The University of Chicago, 929 East 57th Street, Chicago, Illinois 60637, United States
1 shared publication - Bozhi Tian
The James Franck Institute, University of Chicago, Chicago, USA
1 shared publication
Latest Publications
- 27 March 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (10) , 1-12
Mineral-originated bioelectronics for inhibition via lithium electrochemistry
Bioelectronic devices displaying high spatiotemporal resolution and programmability have vast potential for medical applications. However, achieving molecularly specific and fully electronic modulation of bioactivities with exceptional electrical control and precision remains challenging. Here, inspired by naturally occurring mineral–bio interactions, we develop the MOBILE (Mineral-Originated Bioelectronics for Inhibition via Lithium Electrochemistry) platform, which uses triphylite (LiFePO4), a well-known cathode in battery research, as a bioelectronic electrode for specific ion (Li+) mediated biomodulation and achieve precise inhibition of neural activities. Our material platform, representative of a class of electroactive solid-state inorganic materials, operates safely in biofluids and enables ultrafine lithium generation precision, including near-binary ON/OFF switching of lithium injection and highly localized lithium production. Such localization only to the targeting tissue area lowers dosages substantially compared with conventional systematic lithium therapies and prevents potential side effects. We develop a direct photopatterning method that renders LiFePO4 easily adaptable for various bioelectronic devices. Overall, the MOBILE platform demonstrates effective bioactivity inhibition in both the peripheral and central nervous system, making it a potential candidate for pain relief and pointing to future biomedical applications.
- 27 March 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (10) , 1-12
Mineral-originated bioelectronics for inhibition via lithium electrochemistry
Bioelectronic devices displaying high spatiotemporal resolution and programmability have vast potential for medical applications. However, achieving molecularly specific and fully electronic modulation of bioactivities with exceptional electrical control and precision remains challenging. Here, inspired by naturally occurring mineral–bio interactions, we develop the MOBILE (Mineral-Originated Bioelectronics for Inhibition via Lithium Electrochemistry) platform, which uses triphylite (LiFePO4), a well-known cathode in battery research, as a bioelectronic electrode for specific ion (Li+) mediated biomodulation and achieve precise inhibition of neural activities. Our material platform, representative of a class of electroactive solid-state inorganic materials, operates safely in biofluids and enables ultrafine lithium generation precision, including near-binary ON/OFF switching of lithium injection and highly localized lithium production. Such localization only to the targeting tissue area lowers dosages substantially compared with conventional systematic lithium therapies and prevents potential side effects. We develop a direct photopatterning method that renders LiFePO4 easily adaptable for various bioelectronic devices. Overall, the MOBILE platform demonstrates effective bioactivity inhibition in both the peripheral and central nervous system, making it a potential candidate for pain relief and pointing to future biomedical applications.
- 1 February 2024
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 326 (2) , G133-G146
Sex differences in zymosan-induced behavioral visceral hypersensitivity and colorectal afferent sensitization
We used high-throughput GCaMP6f recordings to study 2,275 mechanosensitive colorectal afferents in mice. Our results revealed significant sex differences in the zymosan-induced behavioral visceral hypersensitivity, which were present in male but not female mice. Male mice also showed sensitization of colorectal afferents in the thoracolumbar pathway, whereas female mice did not. These findings highlight sex differences in sensory neural anatomy and function of the colorectum, with implications for sex-specific therapies for treating visceral pain.
- 1 February 2024
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 326 (2) , G133-G146
Sex differences in zymosan-induced behavioral visceral hypersensitivity and colorectal afferent sensitization
We used high-throughput GCaMP6f recordings to study 2,275 mechanosensitive colorectal afferents in mice. Our results revealed significant sex differences in the zymosan-induced behavioral visceral hypersensitivity, which were present in male but not female mice. Male mice also showed sensitization of colorectal afferents in the thoracolumbar pathway, whereas female mice did not. These findings highlight sex differences in sensory neural anatomy and function of the colorectum, with implications for sex-specific therapies for treating visceral pain.
- 17 June 2021
- Published by Wolters Kluwer Health in Pain
- Vol. 163 (4) , 665-681
Blocking peripheral drive from colorectal afferents by subkilohertz dorsal root ganglion stimulation
Clinical evidence indicates dorsal root ganglion (DRG) stimulation effectively reduces pain without the need to evoke paresthesia. This paresthesia-free anesthesia by DRG stimulation can be promising to treat pain from the viscera, where paresthesia usually cannot be produced. Here, we explored the mechanisms and parameters for DRG stimulation using an ex vivo preparation with mouse distal colon and rectum (colorectum), pelvic nerve, L6 DRG, and dorsal root in continuity. We conducted single-fiber recordings from split dorsal root filaments and assessed the effect of DRG stimulation on afferent neural transmission. We determined the optimal stimulus pulse width by measuring the chronaxies of DRG stimulation to be below 216 µs, indicating spike initiation likely at attached axons rather than somata. Subkilohertz DRG stimulation significantly attenuates colorectal afferent transmission (10, 50, 100, 500, and 1000 Hz), of which 50 and 100 Hz show superior blocking effects. Synchronized spinal nerve and DRG stimulation reveals a progressive increase in conduction delay by DRG stimulation, suggesting activity-dependent slowing in blocked fibers. Afferents blocked by DRG stimulation show a greater increase in conduction delay than the unblocked counterparts. Midrange frequencies (50-500 Hz) are more efficient at blocking transmission than lower or higher frequencies. In addition, DRG stimulation at 50 and 100 Hz significantly attenuates in vivo visceromotor responses to noxious colorectal balloon distension. This reversible conduction block in C-type and Aδ-type afferents by subkilohertz DRG stimulation likely underlies the paresthesia-free anesthesia by DRG stimulation, thereby offering a promising new approach for managing chronic visceral pain.
- 17 June 2021
- Published by Wolters Kluwer Health in Pain
- Vol. 163 (4) , 665-681
Blocking peripheral drive from colorectal afferents by subkilohertz dorsal root ganglion stimulation
Clinical evidence indicates dorsal root ganglion (DRG) stimulation effectively reduces pain without the need to evoke paresthesia. This paresthesia-free anesthesia by DRG stimulation can be promising to treat pain from the viscera, where paresthesia usually cannot be produced. Here, we explored the mechanisms and parameters for DRG stimulation using an ex vivo preparation with mouse distal colon and rectum (colorectum), pelvic nerve, L6 DRG, and dorsal root in continuity. We conducted single-fiber recordings from split dorsal root filaments and assessed the effect of DRG stimulation on afferent neural transmission. We determined the optimal stimulus pulse width by measuring the chronaxies of DRG stimulation to be below 216 µs, indicating spike initiation likely at attached axons rather than somata. Subkilohertz DRG stimulation significantly attenuates colorectal afferent transmission (10, 50, 100, 500, and 1000 Hz), of which 50 and 100 Hz show superior blocking effects. Synchronized spinal nerve and DRG stimulation reveals a progressive increase in conduction delay by DRG stimulation, suggesting activity-dependent slowing in blocked fibers. Afferents blocked by DRG stimulation show a greater increase in conduction delay than the unblocked counterparts. Midrange frequencies (50-500 Hz) are more efficient at blocking transmission than lower or higher frequencies. In addition, DRG stimulation at 50 and 100 Hz significantly attenuates in vivo visceromotor responses to noxious colorectal balloon distension. This reversible conduction block in C-type and Aδ-type afferents by subkilohertz DRG stimulation likely underlies the paresthesia-free anesthesia by DRG stimulation, thereby offering a promising new approach for managing chronic visceral pain.
- 9 October 2019
- Published by Springer Nature in Journal of Neural Transmission
- Vol. 127 (4) , 415-429
Visceral pain from colon and rectum: the mechanotransduction and biomechanics
Visceral pain is the cardinal symptom of functional gastrointestinal (GI) disorders such as the irritable bowel syndrome (IBS) and the leading cause of patients’ visit to gastroenterologists. IBS-related visceral pain usually arises from the distal colon and rectum (colorectum), an intraluminal environment that differs greatly from environment outside the body in chemical, biological, thermal, and mechanical conditions. Accordingly, visceral pain is different from cutaneous pain in several key psychophysical characteristics, which likely underlies the unsatisfactory management of visceral pain by drugs developed for other types of pain. Colorectal visceral pain is usually elicited from mechanical distension/stretch, rather than from heating, cutting, pinching, or piercing that usually evoke pain from the skin. Thus, mechanotransduction, i.e., the encoding of colorectal mechanical stimuli by sensory afferents, is crucial to the underlying mechanisms of GI-related visceral pain. This review will focus on colorectal mechanotransduction, the process of converting colorectal mechanical stimuli into trains of action potentials by the sensory afferents to inform the central nervous system (CNS). We will summarize neurophysiological studies on afferent encoding of colorectal mechanical stimuli, highlight recent advances in our understanding of colorectal biomechanics that plays critical roles in mechanotransduction, and review studies on mechano-sensitive ion channels in colorectal afferents. This review calls for focused attention on targeting colorectal mechanotransduction as a new strategy for managing visceral pain, which can also have an added benefit of limited CNS side effects, because mechanotransduction arises from peripheral organs.
- 9 October 2019
- Published by Springer Nature in Journal of Neural Transmission
- Vol. 127 (4) , 415-429
Visceral pain from colon and rectum: the mechanotransduction and biomechanics
Visceral pain is the cardinal symptom of functional gastrointestinal (GI) disorders such as the irritable bowel syndrome (IBS) and the leading cause of patients’ visit to gastroenterologists. IBS-related visceral pain usually arises from the distal colon and rectum (colorectum), an intraluminal environment that differs greatly from environment outside the body in chemical, biological, thermal, and mechanical conditions. Accordingly, visceral pain is different from cutaneous pain in several key psychophysical characteristics, which likely underlies the unsatisfactory management of visceral pain by drugs developed for other types of pain. Colorectal visceral pain is usually elicited from mechanical distension/stretch, rather than from heating, cutting, pinching, or piercing that usually evoke pain from the skin. Thus, mechanotransduction, i.e., the encoding of colorectal mechanical stimuli by sensory afferents, is crucial to the underlying mechanisms of GI-related visceral pain. This review will focus on colorectal mechanotransduction, the process of converting colorectal mechanical stimuli into trains of action potentials by the sensory afferents to inform the central nervous system (CNS). We will summarize neurophysiological studies on afferent encoding of colorectal mechanical stimuli, highlight recent advances in our understanding of colorectal biomechanics that plays critical roles in mechanotransduction, and review studies on mechano-sensitive ion channels in colorectal afferents. This review calls for focused attention on targeting colorectal mechanotransduction as a new strategy for managing visceral pain, which can also have an added benefit of limited CNS side effects, because mechanotransduction arises from peripheral organs.
- Open Access
Odor Recognition with a Spiking Neural Network for Bioelectronic Nose
Electronic noses recognize odors using sensor arrays, and usually face difficulties for odor complicacy, while animals have their own biological sensory capabilities for various types of odors. By implanting electrodes into the olfactory bulb of mammalian animals, odors may be recognized by decoding the recorded neural signals, in order to construct a bioelectronic nose. This paper proposes a spiking neural network (SNN)-based odor recognition method from spike trains recorded by the implanted electrode array. The proposed SNN-based approach exploits rich timing information well in precise time points of spikes. To alleviate the overfitting problem, we design a new SNN learning method with a voltage-based regulation strategy. Experiments are carried out using spike train signals recorded from the main olfactory bulb in rats. Results show that our SNN-based approach achieves the state-of-the-art performance, compared with other methods. With the proposed voltage regulation strategy, it achieves about 15% improvement compared with a classical SNN model.
Open AccessOdor Recognition with a Spiking Neural Network for Bioelectronic Nose
Electronic noses recognize odors using sensor arrays, and usually face difficulties for odor complicacy, while animals have their own biological sensory capabilities for various types of odors. By implanting electrodes into the olfactory bulb of mammalian animals, odors may be recognized by decoding the recorded neural signals, in order to construct a bioelectronic nose. This paper proposes a spiking neural network (SNN)-based odor recognition method from spike trains recorded by the implanted electrode array. The proposed SNN-based approach exploits rich timing information well in precise time points of spikes. To alleviate the overfitting problem, we design a new SNN learning method with a voltage-based regulation strategy. Experiments are carried out using spike train signals recorded from the main olfactory bulb in rats. Results show that our SNN-based approach achieves the state-of-the-art performance, compared with other methods. With the proposed voltage regulation strategy, it achieves about 15% improvement compared with a classical SNN model.
- 3 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045004
In vitro single-unit recordings reveal increased peripheral nerve conduction velocity by focused pulsed ultrasound
Ultrasound that is widely used in medical diagnosis has drawn growing interests as a noninvasive means of neuromodulation. Focused pulsed ultrasound (FPUS) effectively modulates neural encoding and transmission in the peripheral nervous system (PNS) with unclear mechanism of action, which is further confounded by contradictory experimental outcomes from recordings of compound action potentials (CAP). To address that, we developed a novel in vitro set up to achieve simultaneous single-unit recordings from individual mouse sciatic nerve axon and systematically studied the neuromodulation effects of FPUS on individual axon. Unlike previous CAP recordings, our single-unit recordings afford superior spatial and temporal resolution to reveal the subtle but consistent effects of ultrasonic neuromodulation. Our results indicate that, (1) FPUS did not evoke action potentials directly in mouse sciatic nerve at all the tested intensities (spatial peak temporal average intensity, I SPTA of 0.91 to 28.2 W/cm 2 ); (2) FPUS increases the nerve conduction velocity (CV) in both fast-conducting A- and slow-conducting C- type axons with effects more pronounced at increased stimulus duration and intensity; and (3) effects of increased CV is reversible and cannot be attributed to the change of local temperature. Our results support existing theories of non-thermal mechanisms underlying ultrasonic neuromodulation with low-intensity FPUS, including NICE, flexoelectricity, and solition models. This work also provides a solid experimental basis to further advance our mechanistic understandings of ultrasonic neuromodulation in the PNS.
- 3 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045004
In vitro single-unit recordings reveal increased peripheral nerve conduction velocity by focused pulsed ultrasound
Ultrasound that is widely used in medical diagnosis has drawn growing interests as a noninvasive means of neuromodulation. Focused pulsed ultrasound (FPUS) effectively modulates neural encoding and transmission in the peripheral nervous system (PNS) with unclear mechanism of action, which is further confounded by contradictory experimental outcomes from recordings of compound action potentials (CAP). To address that, we developed a novel in vitro set up to achieve simultaneous single-unit recordings from individual mouse sciatic nerve axon and systematically studied the neuromodulation effects of FPUS on individual axon. Unlike previous CAP recordings, our single-unit recordings afford superior spatial and temporal resolution to reveal the subtle but consistent effects of ultrasonic neuromodulation. Our results indicate that, (1) FPUS did not evoke action potentials directly in mouse sciatic nerve at all the tested intensities (spatial peak temporal average intensity, I SPTA of 0.91 to 28.2 W/cm 2 ); (2) FPUS increases the nerve conduction velocity (CV) in both fast-conducting A- and slow-conducting C- type axons with effects more pronounced at increased stimulus duration and intensity; and (3) effects of increased CV is reversible and cannot be attributed to the change of local temperature. Our results support existing theories of non-thermal mechanisms underlying ultrasonic neuromodulation with low-intensity FPUS, including NICE, flexoelectricity, and solition models. This work also provides a solid experimental basis to further advance our mechanistic understandings of ultrasonic neuromodulation in the PNS.
- Open Access
- 26 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045020
In vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Electrode arrays interfacing with peripheral nerves are essential for neuromodulation devices targeting peripheral organs to relieve symptoms. To modulate (i.e., single-unit recording and stimulating) individual peripheral nerve axons remains a technical challenge. Here, we report an in vitro setup to allow simultaneous single-unit recordings from multiple mouse sciatic nerve axons. The sciatic nerve (~30 mm) was harvested and transferred to a tissue chamber, the ~5mm distal end pulled into an adjacent recording chamber filled with paraffin oil. A custom-built multi-wire electrode array was used to interface with split fine nerve filaments. Single-unit action potentials were evoked by electrical stimulation and recorded from 186 axons, of which 49.5% were classed A-type with conduction velocities (CV) greater than 1 m/s and 50.5% were C-type (CV < 1 m/s). The single-unit recordings had no apparent bias towards A- or C-type axons, were robust and repeatable for over 60 minutes, and thus an ideal opportunity to assess different neuromodulation strategies targeting peripheral nerves. For instance, ultrasonic modulation of action potential transmission was assessed using the setup, indicating increased nerve conduction velocity following ultrasound stimulus. This setup can also be used to objectively assess the design of next-generation electrode arrays interfacing with peripheral nerves.
- 26 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045020
Open AccessIn vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Electrode arrays interfacing with peripheral nerves are essential for neuromodulation devices targeting peripheral organs to relieve symptoms. To modulate (i.e., single-unit recording and stimulating) individual peripheral nerve axons remains a technical challenge. Here, we report an in vitro setup to allow simultaneous single-unit recordings from multiple mouse sciatic nerve axons. The sciatic nerve (~30 mm) was harvested and transferred to a tissue chamber, the ~5mm distal end pulled into an adjacent recording chamber filled with paraffin oil. A custom-built multi-wire electrode array was used to interface with split fine nerve filaments. Single-unit action potentials were evoked by electrical stimulation and recorded from 186 axons, of which 49.5% were classed A-type with conduction velocities (CV) greater than 1 m/s and 50.5% were C-type (CV < 1 m/s). The single-unit recordings had no apparent bias towards A- or C-type axons, were robust and repeatable for over 60 minutes, and thus an ideal opportunity to assess different neuromodulation strategies targeting peripheral nerves. For instance, ultrasonic modulation of action potential transmission was assessed using the setup, indicating increased nerve conduction velocity following ultrasound stimulus. This setup can also be used to objectively assess the design of next-generation electrode arrays interfacing with peripheral nerves.