Sheikh Jawad Ilham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sheikh Jawad Ilham has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Mehdi Kiani
School of Electrical Engineering and Computer Science, Pennsylvania State University, University Park, PA, USA
6 shared publications - Bin Feng
Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
3 shared publications - Zeinab Kashani
School of Electrical Engineering and Computer Science, Pennsylvania State University, University Park, PA, USA
3 shared publications - Longtu Chen
University of Connecticut
2 shared publications - Tiantian Guo
The James Franck Institute, The University of Chicago, Chicago, USA
2 shared publications Ardavan Javid
School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA, USA
1 shared publication
Latest Publications
- 1 January 2024
- Published by ELS Publishing Co. Limited in Neuroelectronics
- Vol. 1 (1) , 25-47
A modular 16-channel high-voltage ultrasound phased array system for therapeutic medical applications
An ultrasound (US) phased array with electronic steering and focusing capability can enable high-resolution, large-scale US interventions in various medical research and clinical experiments. For such...
- 1 January 2024
- Published by ELS Publishing Co. Limited in Neuroelectronics
- Vol. 1 (1) , 25-47
A modular 16-channel high-voltage ultrasound phased array system for therapeutic medical applications
An ultrasound (US) phased array with electronic steering and focusing capability can enable high-resolution, large-scale US interventions in various medical research and clinical experiments. For such...
- 28 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 1084-1096
A Review of Ultrasound Neuromodulation Technologies
The invasiveness of neuromodulation technologies that require surgical implantation (e.g., electrical and optical stimulation) may limit their clinical application. Thus, alternative technologies that offer similar benefits without surgery are of paramount importance in the field of neuromodulation. Low-intensity ultrasound is an emerging modality for neural stimulation as ultrasound can be focused in deep tissues with millimeter resolution. Transcranial focused ultrasound stimulation (tFUS) has already been demonstrated in a wide range of animals and even humans at different sonication frequencies (mostly in the sub-MHz range due to the presence of the skull). This article first provides some fundamental knowledge in ultrasound, and then reviews various examples of successful tFUS experiments in animals and humans using different stimulation patterns, as well as available tFUS technologies for generating, focusing, and steering ultrasound beams in neural tissues. In particular, phased array technologies for the ultrasound stimulation application are discussed with an emphasis on the design, fabrication, and integration of ultrasound transducer arrays as well as the design and development of phased array electronics with beamformer and high-voltage driver circuitry. The challenges in tFUS, such as its underlying mechanism, indirect auditory response, and skull aberration effects, are also discussed.
- 28 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 1084-1096
A Review of Ultrasound Neuromodulation Technologies
The invasiveness of neuromodulation technologies that require surgical implantation (e.g., electrical and optical stimulation) may limit their clinical application. Thus, alternative technologies that offer similar benefits without surgery are of paramount importance in the field of neuromodulation. Low-intensity ultrasound is an emerging modality for neural stimulation as ultrasound can be focused in deep tissues with millimeter resolution. Transcranial focused ultrasound stimulation (tFUS) has already been demonstrated in a wide range of animals and even humans at different sonication frequencies (mostly in the sub-MHz range due to the presence of the skull). This article first provides some fundamental knowledge in ultrasound, and then reviews various examples of successful tFUS experiments in animals and humans using different stimulation patterns, as well as available tFUS technologies for generating, focusing, and steering ultrasound beams in neural tissues. In particular, phased array technologies for the ultrasound stimulation application are discussed with an emphasis on the design, fabrication, and integration of ultrasound transducer arrays as well as the design and development of phased array electronics with beamformer and high-voltage driver circuitry. The challenges in tFUS, such as its underlying mechanism, indirect auditory response, and skull aberration effects, are also discussed.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 534-546
Towards High-Resolution Ultrasound Neuromodulation With Crossed-Beam Phased Arrays
Transcranial focused ultrasound stimulation (tFUS) has emerged as a potential noninvasive therapeutic technology. Due to skull attenuations at high ultrasound (US) frequencies, successful tFUS with sufficient penetration depth requires sub-MHz US waves, leading to relatively poor stimulation specificity particularly in the axial direction (perpendicular to the US transducer). This shortcoming can potentially be overcome by utilizing two individual US beams properly crossed in time and space. For large-scale tFUS, a phased array is also required to dynamically steer focused US beams at desired neural targets. This paper presents the theoretical foundation and optimization (through a wave-propagation simulator) of crossed-beam formation using two US phased arrays. It also experimentally validates crossed-beam formation with two custom-made 32-element phased arrays (operating at 555.5 kHz) positioned relatively at different angles. In measurements, the sub-MHz crossed-beam phased arrays achieved 0.8/3.4 mm lateral/axial resolution at a focal distance of ∼ 46 mm, compared to the lateral/axial resolution of 3.4/26.8 mm of the individual phased array at 50 mm focal distance (∼ 28.4-fold improvement in reducing the main focal zone area). The crossed-beam formation in the presence of a rat skull and a tissue layer was also validated in the measurements.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 534-546
Towards High-Resolution Ultrasound Neuromodulation With Crossed-Beam Phased Arrays
Transcranial focused ultrasound stimulation (tFUS) has emerged as a potential noninvasive therapeutic technology. Due to skull attenuations at high ultrasound (US) frequencies, successful tFUS with sufficient penetration depth requires sub-MHz US waves, leading to relatively poor stimulation specificity particularly in the axial direction (perpendicular to the US transducer). This shortcoming can potentially be overcome by utilizing two individual US beams properly crossed in time and space. For large-scale tFUS, a phased array is also required to dynamically steer focused US beams at desired neural targets. This paper presents the theoretical foundation and optimization (through a wave-propagation simulator) of crossed-beam formation using two US phased arrays. It also experimentally validates crossed-beam formation with two custom-made 32-element phased arrays (operating at 555.5 kHz) positioned relatively at different angles. In measurements, the sub-MHz crossed-beam phased arrays achieved 0.8/3.4 mm lateral/axial resolution at a focal distance of ∼ 46 mm, compared to the lateral/axial resolution of 3.4/26.8 mm of the individual phased array at 50 mm focal distance (∼ 28.4-fold improvement in reducing the main focal zone area). The crossed-beam formation in the presence of a rat skull and a tissue layer was also validated in the measurements.
- Open Access
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 184-193
32 Element Piezoelectric Micromachined Ultrasound Transducer (PMUT) Phased Array for Neuromodulation
Interest in utilizing ultrasound (US) transducers for non-invasive neuromodulation treatment, including for low intensity transcranial focused ultrasound stimulation (tFUS), has grown rapidly. The most widely demonstrated US transducers for tFUS are either bulk piezoelectric transducers or capacitive micromachine transducers (CMUT) which require high voltage excitation to operate. In order to advance the development of the US transducers towards small, portable devices for safe tFUS at large scale, a low voltage array of US transducers with beam focusing and steering capability is of interest. This work presents the design methodology, fabrication, and characterization of 32-element phased array piezoelectric micromachined ultrasound transducers (PMUT) using $1.5~\mu \text{m}$ thick Pb(Zr 0.52 Ti $_{{\mathrm {0.48}}})\text{O}_{3}$ films doped with 2 mol% Nb. The electrode/piezoelectric/electrode stack was deposited on a silicon on insulator (SOI) wafer with a $2~\mu \text{m}$ silicon device layer that serves as the passive elastic layer for bending-mode vibration. The fabricated 32-element PMUT has a central frequency at 1.4 MHz. Ultrasound beam focusing and steering (through beamforming) was demonstrated where the array was driven with 14.6 V square unipolar pulses. The PMUT generated a maximum peak-to-peak focused acoustic pressure output of 0.44 MPa at a focal distance of 20 mm with a 9.2 mm and 1 mm axial and lateral resolution, respectively. The maximum pressure is equivalent to a spatial-peak pulse-average intensity of 1.29 W/cm 2 , which is suitable for tFUS application.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 184-193
Open Access32 Element Piezoelectric Micromachined Ultrasound Transducer (PMUT) Phased Array for Neuromodulation
Interest in utilizing ultrasound (US) transducers for non-invasive neuromodulation treatment, including for low intensity transcranial focused ultrasound stimulation (tFUS), has grown rapidly. The most widely demonstrated US transducers for tFUS are either bulk piezoelectric transducers or capacitive micromachine transducers (CMUT) which require high voltage excitation to operate. In order to advance the development of the US transducers towards small, portable devices for safe tFUS at large scale, a low voltage array of US transducers with beam focusing and steering capability is of interest. This work presents the design methodology, fabrication, and characterization of 32-element phased array piezoelectric micromachined ultrasound transducers (PMUT) using $1.5~\mu \text{m}$ thick Pb(Zr 0.52 Ti $_{{\mathrm {0.48}}})\text{O}_{3}$ films doped with 2 mol% Nb. The electrode/piezoelectric/electrode stack was deposited on a silicon on insulator (SOI) wafer with a $2~\mu \text{m}$ silicon device layer that serves as the passive elastic layer for bending-mode vibration. The fabricated 32-element PMUT has a central frequency at 1.4 MHz. Ultrasound beam focusing and steering (through beamforming) was demonstrated where the array was driven with 14.6 V square unipolar pulses. The PMUT generated a maximum peak-to-peak focused acoustic pressure output of 0.44 MPa at a focal distance of 20 mm with a 9.2 mm and 1 mm axial and lateral resolution, respectively. The maximum pressure is equivalent to a spatial-peak pulse-average intensity of 1.29 W/cm 2 , which is suitable for tFUS application.
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (1) , 64-78
Design and Optimization of Ultrasonic Links With Phased Arrays for Wireless Power Transmission to Biomedical Implants
Ultrasound (US) is an attractive modality for wireless power transfer (WPT) to biomedical implants with millimeter (mm) dimensions. To compensate for misalignments in WPT to a mm-sized implant (or powering a network of mm-sized implants), a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused US beams at different locations. This paper presents the theory and design methodology of US WPT links with phased arrays and mm-sized receivers (Rx). For given constraints imposed by the application and fabrication, such as load ( RL ) and focal distance ( F ), the optimal geometries of a US phased array and Rx transducer, as well as the optimal operation frequency ( fc ) are found through an iterative design procedure to maximize the power transfer efficiency (PTE). An optimal figure of merit (FoM) related to PTE is proposed to simplify the US array design. A design example of a US link is presented and optimized for WPT to a mm-sized Rx with a linear array. In measurements, the fabricated 16-element array (10.9×9×1.7 mm 3 ) driven by 100 V pulses at fc of 1.1 MHz with optimal delays for focusing at F = 20 mm generated a US beam with a pressure output of 0.8 MPa. The link could deliver up to 6 mW to a ∼ 1 mm 3 Rx with a PTE of 0.14% ( RL = 850 Ω). The beam steering capability of the array at -45 o to 45 o angles was also characterized.
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (1) , 64-78
Design and Optimization of Ultrasonic Links With Phased Arrays for Wireless Power Transmission to Biomedical Implants
Ultrasound (US) is an attractive modality for wireless power transfer (WPT) to biomedical implants with millimeter (mm) dimensions. To compensate for misalignments in WPT to a mm-sized implant (or powering a network of mm-sized implants), a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused US beams at different locations. This paper presents the theory and design methodology of US WPT links with phased arrays and mm-sized receivers (Rx). For given constraints imposed by the application and fabrication, such as load ( RL ) and focal distance ( F ), the optimal geometries of a US phased array and Rx transducer, as well as the optimal operation frequency ( fc ) are found through an iterative design procedure to maximize the power transfer efficiency (PTE). An optimal figure of merit (FoM) related to PTE is proposed to simplify the US array design. A design example of a US link is presented and optimized for WPT to a mm-sized Rx with a linear array. In measurements, the fabricated 16-element array (10.9×9×1.7 mm 3 ) driven by 100 V pulses at fc of 1.1 MHz with optimal delays for focusing at F = 20 mm generated a US beam with a pressure output of 0.8 MPa. The link could deliver up to 6 mW to a ∼ 1 mm 3 Rx with a PTE of 0.14% ( RL = 850 Ω). The beam steering capability of the array at -45 o to 45 o angles was also characterized.
- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1454-1466
Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation
Low-intensity transcranial focused ultrasound stimulation (tFUS), as a noninvasive neuromodulation modality, has shown to be effective in animals and even humans with improved millimeter-scale spatial resolution compared to its noninvasive counterparts. But conventional tFUS systems are built with bulky single-element ultrasound (US) transducers that must be mechanically moved to change the stimulation target. To achieve large-scale ultrasound neuromodulation (USN) within a given tissue volume, a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused ultrasound beams towards different neural targets. This paper presents the theory and design methodology of US phased arrays for USN at a large scale. For a given tissue volume and sonication frequency (f), the optimal geometry of a US phased array is found with an iterative design procedure that maximizes a figure of merit (FoM) and minimizes side/grating lobes (avoiding off-target stimulation). The proposed FoM provides a balance between the power efficiency and spatial resolution of a US array in USN. A design example of a US phased array has been presented for USN in a rat's brain with an optimized linear US array. In measurements, the fabricated US phased array with 16 elements (16.7×7.7×2 mm3), driven by 150 V (peak-peak) pulses at f = 833.3 kHz, could generate a focused US beam with a lateral resolution of 1.6 mm and pressure output of 1.15 MPa at a focal distance of 12 mm. The capability of the US phased array in beam steering and focusing from -60o to 60o angles was also verified in measurements.
- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1454-1466
Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation
Low-intensity transcranial focused ultrasound stimulation (tFUS), as a noninvasive neuromodulation modality, has shown to be effective in animals and even humans with improved millimeter-scale spatial resolution compared to its noninvasive counterparts. But conventional tFUS systems are built with bulky single-element ultrasound (US) transducers that must be mechanically moved to change the stimulation target. To achieve large-scale ultrasound neuromodulation (USN) within a given tissue volume, a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused ultrasound beams towards different neural targets. This paper presents the theory and design methodology of US phased arrays for USN at a large scale. For a given tissue volume and sonication frequency (f), the optimal geometry of a US phased array is found with an iterative design procedure that maximizes a figure of merit (FoM) and minimizes side/grating lobes (avoiding off-target stimulation). The proposed FoM provides a balance between the power efficiency and spatial resolution of a US array in USN. A design example of a US phased array has been presented for USN in a rat's brain with an optimized linear US array. In measurements, the fabricated US phased array with 16 elements (16.7×7.7×2 mm3), driven by 150 V (peak-peak) pulses at f = 833.3 kHz, could generate a focused US beam with a lateral resolution of 1.6 mm and pressure output of 1.15 MPa at a focal distance of 12 mm. The capability of the US phased array in beam steering and focusing from -60o to 60o angles was also verified in measurements.
- Open Access
- 19 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (8) , 1637
A Review on Ultrasonic Neuromodulation of the Peripheral Nervous System: Enhanced or Suppressed Activities?
Ultrasonic (US) neuromodulation has emerged as a promising therapeutic means by delivering focused energy deep into the nervous tissue. Low-intensity ultrasound (US) directly activates and/or inhibits neurons in the central nervous system (CNS). US neuromodulation of the peripheral nervous system (PNS) is less developed and rarely used clinically. The literature on the neuromodulatory effects of US on the PNS is controversial, with some studies documenting enhanced neural activities, some showing suppressed activities, and others reporting mixed effects. US, with different ranges of intensity and strength, is likely to generate distinct physical effects in the stimulated neuronal tissues, which underlies different experimental outcomes in the literature. In this review, we summarize all the major reports that document the effects of US on peripheral nerve endings, axons, and/or somata in the dorsal root ganglion. In particular, we thoroughly discuss the potential impacts of the following key parameters on the study outcomes of PNS neuromodulation by US: frequency, pulse repetition frequency, duty cycle, intensity, metrics for peripheral neural activities, and type of biological preparations used in the studies. Potential mechanisms of peripheral US neuromodulation are summarized to provide a plausible interpretation of the seemly contradictory effects of enhanced and suppressed neural activities of US neuromodulation.
- 19 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (8) , 1637
Open AccessA Review on Ultrasonic Neuromodulation of the Peripheral Nervous System: Enhanced or Suppressed Activities?
Ultrasonic (US) neuromodulation has emerged as a promising therapeutic means by delivering focused energy deep into the nervous tissue. Low-intensity ultrasound (US) directly activates and/or inhibits neurons in the central nervous system (CNS). US neuromodulation of the peripheral nervous system (PNS) is less developed and rarely used clinically. The literature on the neuromodulatory effects of US on the PNS is controversial, with some studies documenting enhanced neural activities, some showing suppressed activities, and others reporting mixed effects. US, with different ranges of intensity and strength, is likely to generate distinct physical effects in the stimulated neuronal tissues, which underlies different experimental outcomes in the literature. In this review, we summarize all the major reports that document the effects of US on peripheral nerve endings, axons, and/or somata in the dorsal root ganglion. In particular, we thoroughly discuss the potential impacts of the following key parameters on the study outcomes of PNS neuromodulation by US: frequency, pulse repetition frequency, duty cycle, intensity, metrics for peripheral neural activities, and type of biological preparations used in the studies. Potential mechanisms of peripheral US neuromodulation are summarized to provide a plausible interpretation of the seemly contradictory effects of enhanced and suppressed neural activities of US neuromodulation.
- 3 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045004
In vitro single-unit recordings reveal increased peripheral nerve conduction velocity by focused pulsed ultrasound
Ultrasound that is widely used in medical diagnosis has drawn growing interests as a noninvasive means of neuromodulation. Focused pulsed ultrasound (FPUS) effectively modulates neural encoding and transmission in the peripheral nervous system (PNS) with unclear mechanism of action, which is further confounded by contradictory experimental outcomes from recordings of compound action potentials (CAP). To address that, we developed a novel in vitro set up to achieve simultaneous single-unit recordings from individual mouse sciatic nerve axon and systematically studied the neuromodulation effects of FPUS on individual axon. Unlike previous CAP recordings, our single-unit recordings afford superior spatial and temporal resolution to reveal the subtle but consistent effects of ultrasonic neuromodulation. Our results indicate that, (1) FPUS did not evoke action potentials directly in mouse sciatic nerve at all the tested intensities (spatial peak temporal average intensity, I SPTA of 0.91 to 28.2 W/cm 2 ); (2) FPUS increases the nerve conduction velocity (CV) in both fast-conducting A- and slow-conducting C- type axons with effects more pronounced at increased stimulus duration and intensity; and (3) effects of increased CV is reversible and cannot be attributed to the change of local temperature. Our results support existing theories of non-thermal mechanisms underlying ultrasonic neuromodulation with low-intensity FPUS, including NICE, flexoelectricity, and solition models. This work also provides a solid experimental basis to further advance our mechanistic understandings of ultrasonic neuromodulation in the PNS.
- 3 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 045004
In vitro single-unit recordings reveal increased peripheral nerve conduction velocity by focused pulsed ultrasound
Ultrasound that is widely used in medical diagnosis has drawn growing interests as a noninvasive means of neuromodulation. Focused pulsed ultrasound (FPUS) effectively modulates neural encoding and transmission in the peripheral nervous system (PNS) with unclear mechanism of action, which is further confounded by contradictory experimental outcomes from recordings of compound action potentials (CAP). To address that, we developed a novel in vitro set up to achieve simultaneous single-unit recordings from individual mouse sciatic nerve axon and systematically studied the neuromodulation effects of FPUS on individual axon. Unlike previous CAP recordings, our single-unit recordings afford superior spatial and temporal resolution to reveal the subtle but consistent effects of ultrasonic neuromodulation. Our results indicate that, (1) FPUS did not evoke action potentials directly in mouse sciatic nerve at all the tested intensities (spatial peak temporal average intensity, I SPTA of 0.91 to 28.2 W/cm 2 ); (2) FPUS increases the nerve conduction velocity (CV) in both fast-conducting A- and slow-conducting C- type axons with effects more pronounced at increased stimulus duration and intensity; and (3) effects of increased CV is reversible and cannot be attributed to the change of local temperature. Our results support existing theories of non-thermal mechanisms underlying ultrasonic neuromodulation with low-intensity FPUS, including NICE, flexoelectricity, and solition models. This work also provides a solid experimental basis to further advance our mechanistic understandings of ultrasonic neuromodulation in the PNS.
- Open Access
- 26 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045020
In vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Electrode arrays interfacing with peripheral nerves are essential for neuromodulation devices targeting peripheral organs to relieve symptoms. To modulate (i.e., single-unit recording and stimulating) individual peripheral nerve axons remains a technical challenge. Here, we report an in vitro setup to allow simultaneous single-unit recordings from multiple mouse sciatic nerve axons. The sciatic nerve (~30 mm) was harvested and transferred to a tissue chamber, the ~5mm distal end pulled into an adjacent recording chamber filled with paraffin oil. A custom-built multi-wire electrode array was used to interface with split fine nerve filaments. Single-unit action potentials were evoked by electrical stimulation and recorded from 186 axons, of which 49.5% were classed A-type with conduction velocities (CV) greater than 1 m/s and 50.5% were C-type (CV < 1 m/s). The single-unit recordings had no apparent bias towards A- or C-type axons, were robust and repeatable for over 60 minutes, and thus an ideal opportunity to assess different neuromodulation strategies targeting peripheral nerves. For instance, ultrasonic modulation of action potential transmission was assessed using the setup, indicating increased nerve conduction velocity following ultrasound stimulus. This setup can also be used to objectively assess the design of next-generation electrode arrays interfacing with peripheral nerves.
- 26 July 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (4) , 045020
Open AccessIn vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Electrode arrays interfacing with peripheral nerves are essential for neuromodulation devices targeting peripheral organs to relieve symptoms. To modulate (i.e., single-unit recording and stimulating) individual peripheral nerve axons remains a technical challenge. Here, we report an in vitro setup to allow simultaneous single-unit recordings from multiple mouse sciatic nerve axons. The sciatic nerve (~30 mm) was harvested and transferred to a tissue chamber, the ~5mm distal end pulled into an adjacent recording chamber filled with paraffin oil. A custom-built multi-wire electrode array was used to interface with split fine nerve filaments. Single-unit action potentials were evoked by electrical stimulation and recorded from 186 axons, of which 49.5% were classed A-type with conduction velocities (CV) greater than 1 m/s and 50.5% were C-type (CV < 1 m/s). The single-unit recordings had no apparent bias towards A- or C-type axons, were robust and repeatable for over 60 minutes, and thus an ideal opportunity to assess different neuromodulation strategies targeting peripheral nerves. For instance, ultrasonic modulation of action potential transmission was assessed using the setup, indicating increased nerve conduction velocity following ultrasound stimulus. This setup can also be used to objectively assess the design of next-generation electrode arrays interfacing with peripheral nerves.