ÖOÖnder Nazim Onak

Önder Nazim Onak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Önder Nazim Onak has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reducing Line-of-Block Artifacts in Cardiac Activation Maps Estimated Using ECG Imaging: A Comparison of Source Models and Estimation Methods

    by Steffen Schuler, Matthias Schaufelberger, Laura R. Bear, Jake A. Bergquist, Matthijs J. M. Cluitmans, Jaume Coll-Font, Onder N. Onak, Brian Zenger, Axel Loewe, Rob S. MacLeod, et al.

    Objective: To investigatecardiac activation maps estimated using electrocardiographic imaging and to find methods reducing line-of-block (LoB) artifacts, while preserving real LoBs. Methods: Body surface potentials were computed for 137 simulated ventricular excitations. Subsequently, the inverse problem was solved to obtain extracellular potentials (EP) and transmembrane voltages (TMV). From these, activation times (AT) were estimated using four methods and compared to the ground truth. This process was evaluated with two cardiac mesh resolutions. Factors contributing to LoB artifacts were identified by analyzing the impact of spatial and temporal smoothing on the morphology of source signals. Results: AT estimation using a spatiotemporal derivative performed better than using a temporal derivative. Compared to deflection-based AT estimation, correlation-based methods were less prone to LoB artifacts but performed worse in identifying real LoBs. Temporal smoothing could eliminate artifacts for TMVs but not for EPs, which could be linked to their temporal morphology. TMVs led to more accurate ATs on the septum than EPs. Mesh resolution had anegligible effect on inverse reconstructions, but small distances were important for cross-correlation-based estimation of AT delays. Conclusion: LoB artifacts are mainly caused by the inherent spatial smoothing effect of the inverse reconstruction. Among the configurations evaluated, only deflection-based AT estimation in combination with TMVs and strong temporal smoothing can prevent LoB artifacts, while preserving real LoBs. Significance: Regions of slow conduction are of considerable clinical interest and LoB artifacts observed in non-invasive ATs can lead to misinterpretations. We addressed this problem by identifying factors causing such artifacts.


  • A Novel Data-Adaptive Regression Framework Based on Multivariate Adaptive Regression Splines for Electrocardiographic Imaging

    by Önder Nazim Onak, Taha Erenler, Yesim Serinagaoglu Dogrusoz

    Objective: Noninvasive electrocardiographic imaging (ECGI) is a promising tool for revealing crucial cardiac electrical events with diagnostic potential. We propose a novel nonparametric regression framework based on multivariate adaptive regression splines (MARS) for ECGI. Methods: The inverse problem was solved by using the regression model trained with body surface potentials (BSP) and corresponding electrograms (EGM). Simulated data as well as experimental data from torso-tank experiments were used to assess the performance of the proposed method. The robustness of the method to measurement noise and geometric errors were assessed in terms of electrogram reconstruction quality, activation time accuracy, and localization error metrics. The methods were compared with Tikhonov regularization and neural network (NN)-based methods. The resulting mapping functions between the BSPs and EGMs were also used to evaluate the most influential measurement leads. Results: MARS-based method outperformed Tikhonov regularization in terms of reconstruction accuracy and robustness to measurement noise. The effects of geometric errors were remedied to some extent by enriching the training set composition including model errors. The MARS-based method had a comparable performance with NN-based methods, which require the adjustment of many parameters. Conclusion: MARS-based method successfully discovers the inverse mapping functions between the BSPs and EGMs yielding accurate reconstructions, and quantifies the contribution of each BSP lead. Significance: MARS-based method is adaptive, requires fewer parameter adjustments than NN-based methods, and is robust to errors. Thus, it can be a feasible data-driven approach for accurately solving inverse imaging problems.


  • Comparison of Activation Times Estimation for Potential-Based ECG Imaging

    by Matthias Schaufelberger, Steffen Schuler, Laura Bear, Matthijs Cluitmans, Jaume Coll-Font, Önder Nazim Onak, Olaf Doessel, Dana Brooks

    Activation times (AT) describe the sequence of cardiac depolarization and represent one of the most important parameters for analysis of cardiac electrical activity. However, estimation of ATs can be challenging due to multiple sources of noise such as fractionation or baseline wander. If ATs are estimated from signals reconstructed using electrocardiographic imaging (ECGI), additional problems can arise from over-smoothing or due to ambiguities in the inverse problem. Often, resulting AT maps show falsely homogeneous regions or artificial lines of block. As ATs are not only important clinically, but are also commonly used for evaluation of ECGI methods, it is important to understand where these errors come from.


  • Evaluation of multivariate adaptive non-parametric reduced-order model for solving the inverse electrocardiography problem: a simulation study

    by Önder Nazım Onak, Yesim Serinagaoglu Dogrusoz, Gerhard Wilhelm Weber

    In the inverse electrocardiography (ECG) problem, the goal is to reconstruct the heart’s electrical activity from multichannel body surface potentials and a mathematical model of the torso. Over the years, researchers have employed various approaches to solve this ill-posed problem including regularization, optimization, and statistical estimation. It is still a topic of interest especially for researchers and clinicians whose goal is to adopt this technique in clinical applications. Among the wide range of mathematical tools available in the fields of operational research, inverse problems, optimization, and parameter estimation, spline-based techniques have been applied to inverse problems in several areas. If proper spline bases are chosen, the complexity of the problem can be significantly reduced while increasing estimation accuracy. However, there are few studies within the context of the inverse ECG problem that take advantage of this property of the spline-based approaches. In this paper, we evaluate the performance of Multivariate Adaptive Regression Splines (MARS)-based method for the solution of the inverse ECG problem using two different collections of simulated data. The results show that the MARS-based method improves the inverse ECG solutions and is “robust” to modeling errors, especially in terms of localizing the arrhythmia sources.


  • Effects of measurement noise in MARS-based inverse ECG solution approach

    by Önder Nazim Onak, Yeşim Serinağaoğlu Doğrusöz, Gerhard Wilhelm Weber

    The aim in ECG problems is to better understand the electrical activity of a heart. Inverse ECG problem can be described as an estimation of electrical activity of a heart using body surface potentials and geometry. Spline based approaches have been applied to inverse problems in several areas. However, there is a few study exist for the solution of inverse ECG problems using spline-based approaches. If proper spline bases are chosen, the dimension of the problem can be significantly reduced. In addition, by arranging the knot placement, estimation of local behavior of a function can be improved. In this study we explored the applicability of the MARS method to the inverse electrocardiography problem and assessed the it's estimation accuracy robustness against the measurement noise.


  • Effects of a priori parameter selection in minimum relative entropy method on inverse electrocardiography problem

    by Onder Nazim Onak, Yesim Serinagaoglu Dogrusoz, Gerhard Wilhelm Weber

    The goal in inverse electrocardiography (ECG) is to reconstruct cardiac electrical sources from body surface measurements and a mathematical model of torso–heart geometry that relates the sources to the measurements. This problem is ill-posed due to attenuation and smoothing that occur inside the thorax, and small errors in the measurements yield large reconstruction errors. To overcome this, ill-posedness, traditional regularization methods such as Tikhonov regularization and truncated singular value decomposition and statistical approaches such as Bayesian Maximum A Posteriori estimation and Kalman filter have been applied. Statistical methods have yielded accurate inverse solutions; however, they require knowledge of a good a priori probability density function, or state transition definition. Minimum relative entropy (MRE) is an approach for inferring probability density function from a set of constraints and prior information, and may be an alternative to those statistical methods since it operates with more simple prior information definitions. However, success of the MRE method also depends on good choice of prior parameters in the form of upper and lower bound values, expected uncertainty in the model and the prior mean. In this paper, we explore the effects of each of these parameters on the solution of inverse ECG problem and discuss the limitations of the method. Our results show that the prior expected value is the most influential of the three MRE parameters.