Yesim Serinagaoglu Dogrusoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yesim Serinagaoglu Dogrusoz has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Umit Aydin
Elektrik ve Elektronik Muhenisligi Bolumu, Orta Dogu Teknik Universitesi
5 shared publications- Önder Nazim Onak
Institute of Applied Mathematics, METU - Middle East Technical University, Turkey
5 shared publications D.H. Brooks
4 shared publicationsErdem Yanar
ASELSAN/Middle East Technical University, Ankara, Turkey
4 shared publications- Alireza Mazloumi Gavgani
Electrical and Electronics Engineering Department, Middle East Technical University, Ankara, Turkey
3 shared publications - Jana Svehlikova
Institute of Measurement Science, Slovak Academy of Sciences
3 shared publications
Latest Publications
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1328-1339
PULSE: A DL-Assisted Physics-Based Approach to the Inverse Problem of Electrocardiography
This study introduces an innovative approach combining deep-learning techniques with classical physics-based electrocardiographic imaging (ECGI) methods. Our objective is to enhance the accuracy and robustness of ECGI reconstructions. We reshape the optimization expression by splitting variables and formulating building blocks based on update expressions. Specifically, we propose a sequential application of analytical solutions and denoiser neural network blocks (PULSE). The denoiser learns the proximal operator associated with the prior distribution of cardiac potentials directly from data, avoiding hand-crafted assumptions about the distribution. The proposed method is compared with zero-order Tikhonov regularization, Bayesian MAP estimation, and an end-to-end learning technique. We achieved more than 10% improvement in all metrics over Bayesian-MAP, end-to-end learning, and Tikhonov solutions. The performance remained consistent throughout cardiac beats, resulting in a 60% reduction in the interquartile ranges of the reconstruction metrics. Geometric variations did not compromise accuracy, with a median localization error consistently below 1cm. Our framework, adaptable to classical methods, augments the clinical pipeline. Improving the accuracy and robustness of pacing site localization holds significant promise for premature ventricular contraction (PVC) research.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1328-1339
PULSE: A DL-Assisted Physics-Based Approach to the Inverse Problem of Electrocardiography
This study introduces an innovative approach combining deep-learning techniques with classical physics-based electrocardiographic imaging (ECGI) methods. Our objective is to enhance the accuracy and robustness of ECGI reconstructions. We reshape the optimization expression by splitting variables and formulating building blocks based on update expressions. Specifically, we propose a sequential application of analytical solutions and denoiser neural network blocks (PULSE). The denoiser learns the proximal operator associated with the prior distribution of cardiac potentials directly from data, avoiding hand-crafted assumptions about the distribution. The proposed method is compared with zero-order Tikhonov regularization, Bayesian MAP estimation, and an end-to-end learning technique. We achieved more than 10% improvement in all metrics over Bayesian-MAP, end-to-end learning, and Tikhonov solutions. The performance remained consistent throughout cardiac beats, resulting in a 60% reduction in the interquartile ranges of the reconstruction metrics. Geometric variations did not compromise accuracy, with a median localization error consistently below 1cm. Our framework, adaptable to classical methods, augments the clinical pipeline. Improving the accuracy and robustness of pacing site localization holds significant promise for premature ventricular contraction (PVC) research.
- Open Access
- 1 September 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (9) , 095012
Evaluation of five methods for the interpolation of bad leads in the solution of the inverse electrocardiography problem
Objective. This study aims to assess the sensitivity of epicardial potential-based electrocardiographic imaging (ECGI) to the removal or interpolation of bad leads. Approach. We utilized experimental data from two distinct centers. Langendorff-perfused pig (n = 2) and dog (n = 2) hearts were suspended in a human torso-shaped tank and paced from the ventricles. Six different bad lead configurations were designed based on clinical experience. Five interpolation methods were applied to estimate the missing data. Zero-order Tikhonov regularization was used to solve the inverse problem for complete data, data with removed bad leads, and interpolated data. We assessed the quality of interpolated ECG signals and ECGI reconstructions using several metrics, comparing the performance of interpolation methods and the impact of bad lead removal versus interpolation on ECGI. Main results. The performance of ECG interpolation strongly correlated with ECGI reconstruction. The hybrid method exhibited the best performance among interpolation techniques, followed closely by the inverse-forward and Kriging methods. Bad leads located over high amplitude/high gradient areas on the torso significantly impacted ECGI reconstructions, even with minor interpolation errors. The choice between removing or interpolating bad leads depends on the location of missing leads and confidence in interpolation performance. If uncertainty exists, removing bad leads is the safer option, particularly when they are positioned in high amplitude/high gradient regions. In instances where interpolation is necessary, the inverse-forward and Kriging methods, which do not require training, are recommended. Significance. This study represents the first comprehensive evaluation of the advantages and drawbacks of interpolating versus removing bad leads in the context of ECGI, providing valuable insights into ECGI performance.
- 1 September 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (9) , 095012
Open AccessEvaluation of five methods for the interpolation of bad leads in the solution of the inverse electrocardiography problem
Objective. This study aims to assess the sensitivity of epicardial potential-based electrocardiographic imaging (ECGI) to the removal or interpolation of bad leads. Approach. We utilized experimental data from two distinct centers. Langendorff-perfused pig (n = 2) and dog (n = 2) hearts were suspended in a human torso-shaped tank and paced from the ventricles. Six different bad lead configurations were designed based on clinical experience. Five interpolation methods were applied to estimate the missing data. Zero-order Tikhonov regularization was used to solve the inverse problem for complete data, data with removed bad leads, and interpolated data. We assessed the quality of interpolated ECG signals and ECGI reconstructions using several metrics, comparing the performance of interpolation methods and the impact of bad lead removal versus interpolation on ECGI. Main results. The performance of ECG interpolation strongly correlated with ECGI reconstruction. The hybrid method exhibited the best performance among interpolation techniques, followed closely by the inverse-forward and Kriging methods. Bad leads located over high amplitude/high gradient areas on the torso significantly impacted ECGI reconstructions, even with minor interpolation errors. The choice between removing or interpolating bad leads depends on the location of missing leads and confidence in interpolation performance. If uncertainty exists, removing bad leads is the safer option, particularly when they are positioned in high amplitude/high gradient regions. In instances where interpolation is necessary, the inverse-forward and Kriging methods, which do not require training, are recommended. Significance. This study represents the first comprehensive evaluation of the advantages and drawbacks of interpolating versus removing bad leads in the context of ECGI, providing valuable insights into ECGI performance.
- Open Access
- 9 June 2023
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 14, 1197778
Comparison of dipole-based and potential-based ECGI methods for premature ventricular contraction beat localization with clinical data
Introduction: Localization of premature ventricular contraction (PVC) origin to guide the radiofrequency ablation (RFA) procedure is one of the prominent clinical goals of non-invasive electrocardiographic imaging. However, the results reported in the literature vary significantly depending on the source model and the level of complexity in the forward model. This study aims to compare the paced and spontaneous PVC localization performances of dipole-based and potential-based source models and corresponding inverse methods using the same clinical data and to evaluate the effects of torso inhomogeneities on these performances.Methods: The publicly available EP solution data from the EDGAR data repository (BSPs from a maximum of 240 electrodes) with known pacing locations and the Bratislava data (BSPs in 128 leads) with spontaneous PVCs from patients who underwent successful RFA procedures were used. Homogeneous and inhomogeneous torso models and corresponding forward problem solutions were used to relate sources on the closed epicardial and epicardial–endocardial surfaces. The localization error (LE) between the true and estimated pacing site/PVC origin was evaluated.Results: For paced data, the median LE values were 25.2 and 13.9 mm for the dipole-based and potential-based models, respectively. These median LE values were higher for the spontaneous PVC data: 30.2–33.0 mm for the dipole-based model and 28.9–39.2 mm for the potential-based model. The assumption of inhomogeneities in the torso model did not change the dipole-based solutions much, but using an inhomogeneous model improved the potential-based solutions on the epicardial–endocardial ventricular surface.Conclusion: For the specific task of localization of pacing site/PVC origin, the dipole-based source model is more stable and robust than the potential-based source model. The torso inhomogeneities affect the performances of PVC origin localization in each source model differently. Hence, care must be taken in generating patient-specific geometric and forward models depending on the source model representation used in electrocardiographic imaging (ECGI).
- 9 June 2023
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 14, 1197778
Open AccessComparison of dipole-based and potential-based ECGI methods for premature ventricular contraction beat localization with clinical data
Introduction: Localization of premature ventricular contraction (PVC) origin to guide the radiofrequency ablation (RFA) procedure is one of the prominent clinical goals of non-invasive electrocardiographic imaging. However, the results reported in the literature vary significantly depending on the source model and the level of complexity in the forward model. This study aims to compare the paced and spontaneous PVC localization performances of dipole-based and potential-based source models and corresponding inverse methods using the same clinical data and to evaluate the effects of torso inhomogeneities on these performances.Methods: The publicly available EP solution data from the EDGAR data repository (BSPs from a maximum of 240 electrodes) with known pacing locations and the Bratislava data (BSPs in 128 leads) with spontaneous PVCs from patients who underwent successful RFA procedures were used. Homogeneous and inhomogeneous torso models and corresponding forward problem solutions were used to relate sources on the closed epicardial and epicardial–endocardial surfaces. The localization error (LE) between the true and estimated pacing site/PVC origin was evaluated.Results: For paced data, the median LE values were 25.2 and 13.9 mm for the dipole-based and potential-based models, respectively. These median LE values were higher for the spontaneous PVC data: 30.2–33.0 mm for the dipole-based model and 28.9–39.2 mm for the potential-based model. The assumption of inhomogeneities in the torso model did not change the dipole-based solutions much, but using an inhomogeneous model improved the potential-based solutions on the epicardial–endocardial ventricular surface.Conclusion: For the specific task of localization of pacing site/PVC origin, the dipole-based source model is more stable and robust than the potential-based source model. The torso inhomogeneities affect the performances of PVC origin localization in each source model differently. Hence, care must be taken in generating patient-specific geometric and forward models depending on the source model representation used in electrocardiographic imaging (ECGI).
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (2) , 963-974
A Novel Data-Adaptive Regression Framework Based on Multivariate Adaptive Regression Splines for Electrocardiographic Imaging
Objective: Noninvasive electrocardiographic imaging (ECGI) is a promising tool for revealing crucial cardiac electrical events with diagnostic potential. We propose a novel nonparametric regression framework based on multivariate adaptive regression splines (MARS) for ECGI. Methods: The inverse problem was solved by using the regression model trained with body surface potentials (BSP) and corresponding electrograms (EGM). Simulated data as well as experimental data from torso-tank experiments were used to assess the performance of the proposed method. The robustness of the method to measurement noise and geometric errors were assessed in terms of electrogram reconstruction quality, activation time accuracy, and localization error metrics. The methods were compared with Tikhonov regularization and neural network (NN)-based methods. The resulting mapping functions between the BSPs and EGMs were also used to evaluate the most influential measurement leads. Results: MARS-based method outperformed Tikhonov regularization in terms of reconstruction accuracy and robustness to measurement noise. The effects of geometric errors were remedied to some extent by enriching the training set composition including model errors. The MARS-based method had a comparable performance with NN-based methods, which require the adjustment of many parameters. Conclusion: MARS-based method successfully discovers the inverse mapping functions between the BSPs and EGMs yielding accurate reconstructions, and quantifies the contribution of each BSP lead. Significance: MARS-based method is adaptive, requires fewer parameter adjustments than NN-based methods, and is robust to errors. Thus, it can be a feasible data-driven approach for accurately solving inverse imaging problems.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (2) , 963-974
A Novel Data-Adaptive Regression Framework Based on Multivariate Adaptive Regression Splines for Electrocardiographic Imaging
Objective: Noninvasive electrocardiographic imaging (ECGI) is a promising tool for revealing crucial cardiac electrical events with diagnostic potential. We propose a novel nonparametric regression framework based on multivariate adaptive regression splines (MARS) for ECGI. Methods: The inverse problem was solved by using the regression model trained with body surface potentials (BSP) and corresponding electrograms (EGM). Simulated data as well as experimental data from torso-tank experiments were used to assess the performance of the proposed method. The robustness of the method to measurement noise and geometric errors were assessed in terms of electrogram reconstruction quality, activation time accuracy, and localization error metrics. The methods were compared with Tikhonov regularization and neural network (NN)-based methods. The resulting mapping functions between the BSPs and EGMs were also used to evaluate the most influential measurement leads. Results: MARS-based method outperformed Tikhonov regularization in terms of reconstruction accuracy and robustness to measurement noise. The effects of geometric errors were remedied to some extent by enriching the training set composition including model errors. The MARS-based method had a comparable performance with NN-based methods, which require the adjustment of many parameters. Conclusion: MARS-based method successfully discovers the inverse mapping functions between the BSPs and EGMs yielding accurate reconstructions, and quantifies the contribution of each BSP lead. Significance: MARS-based method is adaptive, requires fewer parameter adjustments than NN-based methods, and is robust to errors. Thus, it can be a feasible data-driven approach for accurately solving inverse imaging problems.
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
Use of Simulated Data for the Estimation of Prior Models in Kalman Filter-Based Electrocardiographic Imaging
- 30 December 2020
- Published by Computing in Cardiology
Open AccessUse of Simulated Data for the Estimation of Prior Models in Kalman Filter-Based Electrocardiographic Imaging
- Open Access
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (2) , 436-447
The Impact of Torso Signal Processing on Noninvasive Electrocardiographic Imaging Reconstructions
Goal: To evaluate state-of-the-art signal processing methods for epicardial potential-based noninvasive electrocardiographic imaging reconstructions of single-site pacing data. Methods: Experimental data were obtained from two torso-tank setups in which Langendorff-perfused hearts (n = 4) were suspended and potentials recorded simultaneously from torso and epicardial surfaces. 49 different signal processing methods were applied to torso potentials, grouped as i) high-frequency noise removal (HFR) methods ii) baseline drift removal (BDR) methods and iii) combined HFR+BDR. The inverse problem was solved and reconstructed electrograms and activation maps compared to those directly recorded. Results: HFR showed no difference compared to not filtering in terms of absolute differences in reconstructed electrogram amplitudes nor median correlation in QRS waveforms (p > 0.05). However, correlation and mean absolute error of activation times and pacing site localization were improved with all methods except a notch filter. HFR applied post-reconstruction produced no differences compared to pre-reconstruction. BDR and BDR+HFR significantly improved absolute and relative difference, and correlation in electrograms (p <; 0.05). While BDR+HFR combined improved activation time and pacing site detection, BDR alone produced significantly lower correlation and higher localization errors (p <; 0.05). Conclusion: BDR improves reconstructed electrogram morphologies and amplitudes due to a reduction in lambda value selected for the inverse problem. The simplest method (resetting the isoelectric point) is sufficient to see these improvements. HFR does not impact electrogram accuracy, but does impact post-processing to extract features such as activation times. Removal of line noise is insufficient to see these changes. HFR should be applied post-reconstruction to ensure over-filtering does not occur.
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (2) , 436-447
Open AccessThe Impact of Torso Signal Processing on Noninvasive Electrocardiographic Imaging Reconstructions
Goal: To evaluate state-of-the-art signal processing methods for epicardial potential-based noninvasive electrocardiographic imaging reconstructions of single-site pacing data. Methods: Experimental data were obtained from two torso-tank setups in which Langendorff-perfused hearts (n = 4) were suspended and potentials recorded simultaneously from torso and epicardial surfaces. 49 different signal processing methods were applied to torso potentials, grouped as i) high-frequency noise removal (HFR) methods ii) baseline drift removal (BDR) methods and iii) combined HFR+BDR. The inverse problem was solved and reconstructed electrograms and activation maps compared to those directly recorded. Results: HFR showed no difference compared to not filtering in terms of absolute differences in reconstructed electrogram amplitudes nor median correlation in QRS waveforms (p > 0.05). However, correlation and mean absolute error of activation times and pacing site localization were improved with all methods except a notch filter. HFR applied post-reconstruction produced no differences compared to pre-reconstruction. BDR and BDR+HFR significantly improved absolute and relative difference, and correlation in electrograms (p <; 0.05). While BDR+HFR combined improved activation time and pacing site detection, BDR alone produced significantly lower correlation and higher localization errors (p <; 0.05). Conclusion: BDR improves reconstructed electrogram morphologies and amplitudes due to a reduction in lambda value selected for the inverse problem. The simplest method (resetting the isoelectric point) is sufficient to see these improvements. HFR does not impact electrogram accuracy, but does impact post-processing to extract features such as activation times. Removal of line noise is insufficient to see these changes. HFR should be applied post-reconstruction to ensure over-filtering does not occur.
- 30 December 2019
- Published by Computing in Cardiology in Computing in cardiology
- Vol. 46
Effects of Interpolation on the Inverse Problem of Electrocardiography
Electrocardiographic Imaging (ECGI) aims to reconstruct electrograms from the body surface potential measurements. Bad leads are usually excluded from the inverse problem solution. Alternatively, interpolation can be applied. This study explores how sensitive ECGI is to different bad-lead configurations and interpolation methods. Experimental data from a Langendorff-perfused pig heart suspended in a human-shaped torso-tank was used. Epicardial electrograms were acquired during 30 s (31 beats) of RV pacing using a 108-electrode array, simultaneously with torso potentials from 128 electrodes embedded in the tank surface. Six different bad lead cases were designed based on clinical experience. Inverse problem was solved by applying Tikhonov regularization i) using the complete data, ii) bad-leads-removed data, and iii) interpolated data, with 5 different methods. Our results showed that ECGI accuracy of an interpolation method highly depends on the location of the bad leads. If they are in the high-potential-gradient regions of the torso, a highly accurate interpolation method is needed to achieve an ECGI accuracy close to using complete data. If the BSP reconstruction of the interpolation method is poor in these regions, the reconstructed electrograms also have lower accuracy, suggesting that bad leads should be removed instead of interpolated. The inverse-forward method was found to be the best among all interpolation methods applied in this study in terms of both missing BSP lead reconstruction and ECGI accuracy, even for the bad leads located over the chest.
- 30 December 2019
- Published by Computing in Cardiology in Computing in cardiology
- Vol. 46
Effects of Interpolation on the Inverse Problem of Electrocardiography
Electrocardiographic Imaging (ECGI) aims to reconstruct electrograms from the body surface potential measurements. Bad leads are usually excluded from the inverse problem solution. Alternatively, interpolation can be applied. This study explores how sensitive ECGI is to different bad-lead configurations and interpolation methods. Experimental data from a Langendorff-perfused pig heart suspended in a human-shaped torso-tank was used. Epicardial electrograms were acquired during 30 s (31 beats) of RV pacing using a 108-electrode array, simultaneously with torso potentials from 128 electrodes embedded in the tank surface. Six different bad lead cases were designed based on clinical experience. Inverse problem was solved by applying Tikhonov regularization i) using the complete data, ii) bad-leads-removed data, and iii) interpolated data, with 5 different methods. Our results showed that ECGI accuracy of an interpolation method highly depends on the location of the bad leads. If they are in the high-potential-gradient regions of the torso, a highly accurate interpolation method is needed to achieve an ECGI accuracy close to using complete data. If the BSP reconstruction of the interpolation method is poor in these regions, the reconstructed electrograms also have lower accuracy, suggesting that bad leads should be removed instead of interpolated. The inverse-forward method was found to be the best among all interpolation methods applied in this study in terms of both missing BSP lead reconstruction and ECGI accuracy, even for the bad leads located over the chest.
- 30 July 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (10) , 2093-2113
ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging
In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-posed. Among many regularization approaches used in the ECG literature to overcome this ill-posedness, statistical techniques have received great attention because of their flexibility to represent the data, and ability to provide performance evaluation tools for quantification of uncertainties and errors in the model. However, despite their potential to accurately reconstruct the equivalent cardiac sources, one major challenge in these methods is how to best utilize the prior information available in terms of training data. In this paper, we address the question of how to define the prior probability distributions (pdf) of the sources and the error terms so that we can obtain more accurate and robust inverse solutions. We employ two methods, maximum likelihood (ML) and maximum a posteriori (MAP), for estimating the model parameters such as the prior pdfs, error pdfs, and the state-transition matrix, based on the same training data. These model parameters are then used for the state-space representation and estimation of the epicardial potentials, which constitute the equivalent cardiac sources in this study. The performances of ML- and MAP-based model parameter estimation methods are evaluated qualitatively and quantitatively at various noise levels and geometric disturbances using two different simulated datasets. Bayesian MAP estimation, which is also a well-known statistical inversion technique, and Tikhonov regularization, which can be formulated as a special and simplified version of Bayesian MAP estimation, have been included here for comparison with the Kalman filtering method. Our results show that the state-space approach outperforms Bayesian MAP estimation in all cases; ML yields accurate results when the test and training beats come from the same physiological model, but MAP is superior to ML, especially if the test and training beats are from different physiological models. ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging
- 30 July 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (10) , 2093-2113
ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging
In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-posed. Among many regularization approaches used in the ECG literature to overcome this ill-posedness, statistical techniques have received great attention because of their flexibility to represent the data, and ability to provide performance evaluation tools for quantification of uncertainties and errors in the model. However, despite their potential to accurately reconstruct the equivalent cardiac sources, one major challenge in these methods is how to best utilize the prior information available in terms of training data. In this paper, we address the question of how to define the prior probability distributions (pdf) of the sources and the error terms so that we can obtain more accurate and robust inverse solutions. We employ two methods, maximum likelihood (ML) and maximum a posteriori (MAP), for estimating the model parameters such as the prior pdfs, error pdfs, and the state-transition matrix, based on the same training data. These model parameters are then used for the state-space representation and estimation of the epicardial potentials, which constitute the equivalent cardiac sources in this study. The performances of ML- and MAP-based model parameter estimation methods are evaluated qualitatively and quantitatively at various noise levels and geometric disturbances using two different simulated datasets. Bayesian MAP estimation, which is also a well-known statistical inversion technique, and Tikhonov regularization, which can be formulated as a special and simplified version of Bayesian MAP estimation, have been included here for comparison with the Kalman filtering method. Our results show that the state-space approach outperforms Bayesian MAP estimation in all cases; ML yields accurate results when the test and training beats come from the same physiological model, but MAP is superior to ML, especially if the test and training beats are from different physiological models. ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging