Nathan Salowitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nathan Salowitz has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Istiaque Haider
University of Wisconsin - Milwaukee, Milwaukee, WI
8 shared publications Zhiqiang Guo
Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
7 shared publications- Armin Yazdi
University of Wisconsin - Milwaukee, Milwaukee, WI
6 shared publications Fu-Kuo Chang
Stanford University, Stanford, CA, USA
6 shared publications- Maysam Rezaee
University of Wisconsin - Milwaukee, Milwaukee, WI
6 shared publications Yu-Hung Li
Stanford University, Stanford, CA, USA
6 shared publications
Latest Publications
- 1 December 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (12) , 125043
Designing self-healing capabilities in a novel metal matrix composite: integrating shape memory alloys through theoretical modeling and experimental analysis
This study presents the design and development of self-healing metal matrix composites with shape memory alloy (SMA) fibers embedded in an Sn–Bi alloy matrix to achieve effective crack closure and structural recovery. A modified self-healing model based on Johnson–Cook (J–C) theory is introduced to predict the optimal volume fraction of SMA fibers required for efficient healing. The model accounts for key parameters including recovery stress in SMA fibers, pre-strain, healing temperature, and matrix composition. A novel two-stage healing process is developed, where the first stage involves narrowing the crack and restoring the sample’s shape through SMA fiber contraction above the transition temperature, followed by raising the temperature to allow eutectic metal to flow into the crack and seal it. This two-stage approach ensures both shape recovery and complete crack sealing, resulting in enhanced healing performance. Experimental validation includes real-time crack closure observations using digital image correlation, along with post-healing microstructural evaluations at the crack interface through scanning electron microscopy and 3D laser profilometry. The study assesses crack closure rate, shape restoration from SMA fibers, and flexural strength recovery. Results demonstrate that the optimal SMA fiber volume predicted by the modified J–C model leads to complete crack closure, near-complete shape recovery, and up to 96% strength recovery. These findings validate the reliability of modified model and healing approach, underscoring its potential for designing effective self-healing metal composites, even for higher melting temperature metals and alloys.
- 1 December 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (12) , 125043
Designing self-healing capabilities in a novel metal matrix composite: integrating shape memory alloys through theoretical modeling and experimental analysis
This study presents the design and development of self-healing metal matrix composites with shape memory alloy (SMA) fibers embedded in an Sn–Bi alloy matrix to achieve effective crack closure and structural recovery. A modified self-healing model based on Johnson–Cook (J–C) theory is introduced to predict the optimal volume fraction of SMA fibers required for efficient healing. The model accounts for key parameters including recovery stress in SMA fibers, pre-strain, healing temperature, and matrix composition. A novel two-stage healing process is developed, where the first stage involves narrowing the crack and restoring the sample’s shape through SMA fiber contraction above the transition temperature, followed by raising the temperature to allow eutectic metal to flow into the crack and seal it. This two-stage approach ensures both shape recovery and complete crack sealing, resulting in enhanced healing performance. Experimental validation includes real-time crack closure observations using digital image correlation, along with post-healing microstructural evaluations at the crack interface through scanning electron microscopy and 3D laser profilometry. The study assesses crack closure rate, shape restoration from SMA fibers, and flexural strength recovery. Results demonstrate that the optimal SMA fiber volume predicted by the modified J–C model leads to complete crack closure, near-complete shape recovery, and up to 96% strength recovery. These findings validate the reliability of modified model and healing approach, underscoring its potential for designing effective self-healing metal composites, even for higher melting temperature metals and alloys.
- 8 July 2025
- Published by SAGE Publications in Structural Health Monitoring
Integration of structural health monitoring in shape memory alloy reinforced self-healing matrix composites using piezoelectric transducers
Integrating self-healing materials with structural health monitoring (SHM) represents a significant advancement in materials science and engineering. In applications such as aerospace, self-healing composites with SHM can detect and repair damage autonomously, enhancing safety and reducing maintenance time, which significantly improves structural durability by maintaining integrity and extending material service life. This research employs an experimental approach to validate the self-healing process of self-healing metal matrix composites reinforced with shape memory alloy fibers, by utilizing lead zirconate titanate (PZT) piezoelectric transducers mounted on the surface of the composite. A three-point bending test is used to induce damage in the metal matrix composites by applying a load at its midpoint while supporting it at both ends; then, self-healing is used to return the specimen to its original state. The ultrasonic signals from the PZT sensor were compared at three stages: pristine state, during bending (i.e., damage), and after the healing process, to evaluate the effectiveness of the healing process and health monitoring technique adopted for this study. Real-time monitoring using digital image correlation, laser profilometry, and mechanical testing was used to validate the damaged/healed signal state—demonstrated by improved recovered signal amplitude, reduced scatter energy, a notable decrease in damage indices root-mean-square deviation, normalized scatter energy, and stabilized wave propagation. The successful self-healing composite design and health monitoring results confirm the restoration of the specimen, which regained 84% of its initial shape deformation at 135 °C for 30 min (i.e., during the first step of healing). Complete shape restoration was achieved by raising the temperature to 150 °C for 90 min (during the second step of healing), recovering approximately 96% of the original flexural strength after healing.
- 8 July 2025
- Published by SAGE Publications in Structural Health Monitoring
Integration of structural health monitoring in shape memory alloy reinforced self-healing matrix composites using piezoelectric transducers
Integrating self-healing materials with structural health monitoring (SHM) represents a significant advancement in materials science and engineering. In applications such as aerospace, self-healing composites with SHM can detect and repair damage autonomously, enhancing safety and reducing maintenance time, which significantly improves structural durability by maintaining integrity and extending material service life. This research employs an experimental approach to validate the self-healing process of self-healing metal matrix composites reinforced with shape memory alloy fibers, by utilizing lead zirconate titanate (PZT) piezoelectric transducers mounted on the surface of the composite. A three-point bending test is used to induce damage in the metal matrix composites by applying a load at its midpoint while supporting it at both ends; then, self-healing is used to return the specimen to its original state. The ultrasonic signals from the PZT sensor were compared at three stages: pristine state, during bending (i.e., damage), and after the healing process, to evaluate the effectiveness of the healing process and health monitoring technique adopted for this study. Real-time monitoring using digital image correlation, laser profilometry, and mechanical testing was used to validate the damaged/healed signal state—demonstrated by improved recovered signal amplitude, reduced scatter energy, a notable decrease in damage indices root-mean-square deviation, normalized scatter energy, and stabilized wave propagation. The successful self-healing composite design and health monitoring results confirm the restoration of the specimen, which regained 84% of its initial shape deformation at 135 °C for 30 min (i.e., during the first step of healing). Complete shape restoration was achieved by raising the temperature to 150 °C for 90 min (during the second step of healing), recovering approximately 96% of the original flexural strength after healing.
- Open Access
Sensing with Thermally Reduced Graphene Oxide under Repeated Large Multi-Directional Strain
This paper presents a recent investigation into the electromechanical behavior of thermally reduced graphene oxide (rGO) as a strain sensor undergoing repeated large mechanical strains up to 20.72%, with electrical signal output measurement in multiple directions relative to the applied strain. Strain is one the most basic and most common stimuli sensed. rGO can be synthesized from abundant materials, can survive exposure to large strains (up to 20.72%), can be synthesized directly on structures with relative ease, and provides high sensitivity, with gauge factors up to 200 regularly reported. In this investigation, a suspension of graphene oxide flakes was deposited onto Polydimethylsiloxane (PDMS) substrates and thermally reduced to create macroscopic rGO-strain sensors. Electrical resistance parallel to the direction of applied tension () demonstrated linear behavior (similar to the piezoresistive behavior of solid materials under strain) up to strains around 7.5%, beyond which nonlinear resistive behavior (similar to percolative electrical behavior) was observed. Cyclic tensile testing results suggested that some residual micro-cracks remained in place after relaxation from the first cycle of tensile loading. A linear fit across the range of strains investigated produced a gauge factor of 91.50(Ω/Ω)/(m/m), though it was observed that the behavior at high strains was clearly nonlinear. Hysteresis testing showed high consistency in the electromechanical response of the sensor between loading and unloading within cycles as well as increased consistency in the pattern of the response between different cycles starting from cycle 2.Open AccessSensing with Thermally Reduced Graphene Oxide under Repeated Large Multi-Directional Strain
This paper presents a recent investigation into the electromechanical behavior of thermally reduced graphene oxide (rGO) as a strain sensor undergoing repeated large mechanical strains up to 20.72%, with electrical signal output measurement in multiple directions relative to the applied strain. Strain is one the most basic and most common stimuli sensed. rGO can be synthesized from abundant materials, can survive exposure to large strains (up to 20.72%), can be synthesized directly on structures with relative ease, and provides high sensitivity, with gauge factors up to 200 regularly reported. In this investigation, a suspension of graphene oxide flakes was deposited onto Polydimethylsiloxane (PDMS) substrates and thermally reduced to create macroscopic rGO-strain sensors. Electrical resistance parallel to the direction of applied tension () demonstrated linear behavior (similar to the piezoresistive behavior of solid materials under strain) up to strains around 7.5%, beyond which nonlinear resistive behavior (similar to percolative electrical behavior) was observed. Cyclic tensile testing results suggested that some residual micro-cracks remained in place after relaxation from the first cycle of tensile loading. A linear fit across the range of strains investigated produced a gauge factor of 91.50(Ω/Ω)/(m/m), though it was observed that the behavior at high strains was clearly nonlinear. Hysteresis testing showed high consistency in the electromechanical response of the sensor between loading and unloading within cycles as well as increased consistency in the pattern of the response between different cycles starting from cycle 2. - Open Access
- 12 October 2023
- Published by Wisconsin Space Grant Consortium in Proceedings of the Wisconsin Space Conference
Analysis of Shape-Memory-Alloy Fiber Interface Strength for Optimization of Self-Healing Composites
Self-healing materials, possessing an innate ability to mend damage and restore structural strength, have tremendous potential to improve safety and reliability, especially in space applications where recovery or manual performance of repairs may be prohibitive, dangerous, or impossible. Self-healing metallic materials developed with Nickel Titanium (NiTi) Shape Memory Alloy (SMA) reinforcement showed a promising prospect for recovering from larger scale damage. However, NiTi is known to form an inert oxide (TiO2) surface layer that is extremely hard to attach to. In this research, to promote better strength between the fiber and matrix, TiO2 surface layer has been removed by etching the NiTi wires in an inert environment and a pull test has been performed to evaluate the resulting change in adhesion strength between the fiber and metallic matrix. The experimental investigation of these interface fracture scenarios will enable the efficient design of composite materials.
- 12 October 2023
- Published by Wisconsin Space Grant Consortium in Proceedings of the Wisconsin Space Conference
Open AccessAnalysis of Shape-Memory-Alloy Fiber Interface Strength for Optimization of Self-Healing Composites
Self-healing materials, possessing an innate ability to mend damage and restore structural strength, have tremendous potential to improve safety and reliability, especially in space applications where recovery or manual performance of repairs may be prohibitive, dangerous, or impossible. Self-healing metallic materials developed with Nickel Titanium (NiTi) Shape Memory Alloy (SMA) reinforcement showed a promising prospect for recovering from larger scale damage. However, NiTi is known to form an inert oxide (TiO2) surface layer that is extremely hard to attach to. In this research, to promote better strength between the fiber and matrix, TiO2 surface layer has been removed by etching the NiTi wires in an inert environment and a pull test has been performed to evaluate the resulting change in adhesion strength between the fiber and metallic matrix. The experimental investigation of these interface fracture scenarios will enable the efficient design of composite materials.
- 28 September 2023
- Published by Wiley in Advanced Engineering Materials
- Vol. 25 (22)
On the Nature of Post‐Constrained Recovery Residual Stress of NiTi Shape Memory Alloys
In this article, the nature of the post‐constrained recovery residual stress (PCRRS) observed in nickel titanium (NiTi) shape memory alloys (SMAs) subjected to constrained recovery and returned to a low‐temperature state while remaining constrained is investigated. After performing the thermomechanical cycling to produce the PCRRS state, four experiments are performed with different deflection profiles applied from the PCRRS state, and the changes in the residual stress is observed. All tests produce a gradual decrease in stress after every load cycle, similar to cyclic softening. However, repetition of the process used to initially generate PCRRS restores the initial magnitude of the PCRRS, indicating that the decrease in residual stress is a stable, repeatable, and reversible phenomenon, and not true material degradation. To better understand the nature of PCRRS, an analysis is performed comparing the modulus relating stress and strain at different points along the thermomechanical loading path. In this analysis, it is shown that NiTi has a combination of twinned and detwinned martensite in the PCRRS state. Understanding the nature of PCRRS, properties and its stability have the potential for advanced engineering applications such as self‐healing and fatigue‐resistant materials by generating stresses without continuous actuation over a long period of time.
- 28 September 2023
- Published by Wiley in Advanced Engineering Materials
- Vol. 25 (22)
On the Nature of Post‐Constrained Recovery Residual Stress of NiTi Shape Memory Alloys
In this article, the nature of the post‐constrained recovery residual stress (PCRRS) observed in nickel titanium (NiTi) shape memory alloys (SMAs) subjected to constrained recovery and returned to a low‐temperature state while remaining constrained is investigated. After performing the thermomechanical cycling to produce the PCRRS state, four experiments are performed with different deflection profiles applied from the PCRRS state, and the changes in the residual stress is observed. All tests produce a gradual decrease in stress after every load cycle, similar to cyclic softening. However, repetition of the process used to initially generate PCRRS restores the initial magnitude of the PCRRS, indicating that the decrease in residual stress is a stable, repeatable, and reversible phenomenon, and not true material degradation. To better understand the nature of PCRRS, an analysis is performed comparing the modulus relating stress and strain at different points along the thermomechanical loading path. In this analysis, it is shown that NiTi has a combination of twinned and detwinned martensite in the PCRRS state. Understanding the nature of PCRRS, properties and its stability have the potential for advanced engineering applications such as self‐healing and fatigue‐resistant materials by generating stresses without continuous actuation over a long period of time.
- 22 June 2022
- Published by Springer Nature
- p. 963-971
Low Flow Rate Measurement and Leak Detection for Health Monitoring of Water Equipment
- 22 June 2022
- Published by Springer Nature
- p. 963-971
Low Flow Rate Measurement and Leak Detection for Health Monitoring of Water Equipment
- Open Access
Investigation into the Performance of NiTi Shape Memory Alloy Wire Reinforced Sn-Bi Self-Healing Metal Matrix Composite
Self-healing materials have the potential to create a paradigm shift in the life cycle design of engineered structures, by changing the relation between material damage and structural failure, affecting structures’ lifetime, safety, and reliability. However, the knowledge of self-healing capabilities in metallic materials is still in its infancy compared to other material systems because of challenges in the synthesis of organized and complex structures. This paper presents a study of a metal matrix composite system that was synthesized with an off-eutectic Tin (Sn)-Bismuth (Bi) alloy matrix, reinforced with Nickel–Titanium (NiTi) shape memory alloy (SMA) wires. The ability to close cracks, recover bulk geometry, and regenerate strength upon the application of heat was investigated. NiTi wires were etched and coated in flux before being incorporated into the matrix to prevent disbonding with the matrix. Samples were subjected to large deformations in a three-point bending setup. Subsequent thermo-mechanical testing of the composites confirmed the materials’ ability to restore their geometry and recover strength, without using any consumable components. Self-healing was accomplished through a combination of activation of the shape memory effect in the NiTi to recover the samples’ original macroscopic geometry, closing cracks, and melting of the eutectic material in the matrix alloy, which resealed the cracks. Subsequent testing indicated a 92% strength recovery.
Open AccessInvestigation into the Performance of NiTi Shape Memory Alloy Wire Reinforced Sn-Bi Self-Healing Metal Matrix Composite
Self-healing materials have the potential to create a paradigm shift in the life cycle design of engineered structures, by changing the relation between material damage and structural failure, affecting structures’ lifetime, safety, and reliability. However, the knowledge of self-healing capabilities in metallic materials is still in its infancy compared to other material systems because of challenges in the synthesis of organized and complex structures. This paper presents a study of a metal matrix composite system that was synthesized with an off-eutectic Tin (Sn)-Bismuth (Bi) alloy matrix, reinforced with Nickel–Titanium (NiTi) shape memory alloy (SMA) wires. The ability to close cracks, recover bulk geometry, and regenerate strength upon the application of heat was investigated. NiTi wires were etched and coated in flux before being incorporated into the matrix to prevent disbonding with the matrix. Samples were subjected to large deformations in a three-point bending setup. Subsequent thermo-mechanical testing of the composites confirmed the materials’ ability to restore their geometry and recover strength, without using any consumable components. Self-healing was accomplished through a combination of activation of the shape memory effect in the NiTi to recover the samples’ original macroscopic geometry, closing cracks, and melting of the eutectic material in the matrix alloy, which resealed the cracks. Subsequent testing indicated a 92% strength recovery.
- Open Access
- 25 February 2022
- Published by Wisconsin Space Grant Consortium in Proceedings of the Wisconsin Space Conference
- Vol. 1 (1)
Explorations of Post Constrained Recovery Residual Stress of Shape Memory Alloys in Self-healing Applications
Self-healing materials with intrinsic capabilities of geometric restoration and damage recovery have a tremendous potential to improve product safety and reliability, especially in space applications where recovery or manual performance of repairs may be prohibitive, dangerous, or impossible. Self-healing materials typically incorporate a complex internal structure containing constituent materials of different functionality and one of the primary methods is to reinforce self-healing materials with shape memory alloys that can be activated to restore geometry and close a fracture. Recent experimental investigation revealed that Nickel Titanium (NiTi) shape memory alloys (SMAs) could repeatedly produce stable residual stresses following constrained recovery when held in a constrained condition during temperature change through the forward and reverse transformations. The ability to produce this post constrained recovery residual stress (PCRRS) in a low temperature state, without continuous actuation, and to regenerate it repeatedly have the potential to advance self-healing capabilities and even damage prevention.
- 25 February 2022
- Published by Wisconsin Space Grant Consortium in Proceedings of the Wisconsin Space Conference
- Vol. 1 (1)
Open AccessExplorations of Post Constrained Recovery Residual Stress of Shape Memory Alloys in Self-healing Applications
Self-healing materials with intrinsic capabilities of geometric restoration and damage recovery have a tremendous potential to improve product safety and reliability, especially in space applications where recovery or manual performance of repairs may be prohibitive, dangerous, or impossible. Self-healing materials typically incorporate a complex internal structure containing constituent materials of different functionality and one of the primary methods is to reinforce self-healing materials with shape memory alloys that can be activated to restore geometry and close a fracture. Recent experimental investigation revealed that Nickel Titanium (NiTi) shape memory alloys (SMAs) could repeatedly produce stable residual stresses following constrained recovery when held in a constrained condition during temperature change through the forward and reverse transformations. The ability to produce this post constrained recovery residual stress (PCRRS) in a low temperature state, without continuous actuation, and to regenerate it repeatedly have the potential to advance self-healing capabilities and even damage prevention.
- 14 September 2021
- Published by ASME International
Phenomenological Assessment of Post Constrained Recovery Residual Stress of Shape Memory Alloys
Shape memory alloys (SMAs) are frequently used in a broad spectrum of commercially valuable and innovative applications due to its high specific energy density as an actuator and simple thermal actuation. This paper presents a study seeking to understand a recently discovered property of Nickel Titanium (NiTi) SMAs where they can repeatedly produce stable residual stresses after undergoing constrained recovery and returning to a low temperature, martensitic, state. The underlying mechanisms of this post constrained recovery residual stress (PCRRS) are still under investigation. Experiments on multiple formulations of NiTi based SMAs (including a ternary material) confirmed the PCRRS generation in every SMA tested and following the exposures to further application of small cyclic strain (both tensile and compressive) from PCRRS states revealed a cyclic softening like phenomena where the magnitude of residual stresses over every small strain exposure were incrementally reduced, but the repetition of the constrained recovery process reproduced the initial residual stress. This paper presents the results of new experiments that help explain the nature of the PCRRS phenomena, discussion of the cyclic softening phenomena with small strain applications and a conceptual study to understand the underlying mechanism of PCRRS based modulus comparison in different loading states during PCRRS generation. The capability to produce PCRRS and its repeating regeneration provides a new way for the material to be used as an actuator that may be beneficial to applications like self-healing material and could support new applications like using a dispersion of NiTi particles to inhibit fatigue cracking in material structures. Novel actuation mechanism can be developed and designed through PCRRS based on the potential energy stored in the structures to use in different applications and smart material design.
- 14 September 2021
- Published by ASME International
Phenomenological Assessment of Post Constrained Recovery Residual Stress of Shape Memory Alloys
Shape memory alloys (SMAs) are frequently used in a broad spectrum of commercially valuable and innovative applications due to its high specific energy density as an actuator and simple thermal actuation. This paper presents a study seeking to understand a recently discovered property of Nickel Titanium (NiTi) SMAs where they can repeatedly produce stable residual stresses after undergoing constrained recovery and returning to a low temperature, martensitic, state. The underlying mechanisms of this post constrained recovery residual stress (PCRRS) are still under investigation. Experiments on multiple formulations of NiTi based SMAs (including a ternary material) confirmed the PCRRS generation in every SMA tested and following the exposures to further application of small cyclic strain (both tensile and compressive) from PCRRS states revealed a cyclic softening like phenomena where the magnitude of residual stresses over every small strain exposure were incrementally reduced, but the repetition of the constrained recovery process reproduced the initial residual stress. This paper presents the results of new experiments that help explain the nature of the PCRRS phenomena, discussion of the cyclic softening phenomena with small strain applications and a conceptual study to understand the underlying mechanism of PCRRS based modulus comparison in different loading states during PCRRS generation. The capability to produce PCRRS and its repeating regeneration provides a new way for the material to be used as an actuator that may be beneficial to applications like self-healing material and could support new applications like using a dispersion of NiTi particles to inhibit fatigue cracking in material structures. Novel actuation mechanism can be developed and designed through PCRRS based on the potential energy stored in the structures to use in different applications and smart material design.
- Open Access
The Effect of Various Parameters on a Portable Sensor for the Detection of Thin Biofilms in Water Pipes
The use of high-frequency strain waves to perform examinations and note measurements is referred to as ultrasonic testing (UT). UT is commonly used for the detection or evaluation of flaws and characterization of materials, among other applications. A standard ultrasonic inspection system comprises a pulser/receiver, transducer, and display devices. The pulser/receiver produces electrical pulses of high voltage. The transducer generates high-frequency ultrasonic energy after being driven by the pulser. The reflected wave is then converted into an electrical signal by the transducer and is displayed on a screen. The reflected signal strength versus the time plot helps to glean information regarding the features of a defect. In this paper, we discuss the experiments performed in a laboratory setting to determine ultrasound-based biofilm sensor sensitivity in relation to changes in the surrounding environment of temperature, concentration, turbidity, and conductivity of the liquid passing through the system. The effect of the change in frequency of the sensors was also studied. The sensors being developed are small and compact, portable, can be placed on the outer walls of the desired surface, use digital signal processing techniques, and the biofilm presence on the inner walls of the surface can be monitored.
Open AccessThe Effect of Various Parameters on a Portable Sensor for the Detection of Thin Biofilms in Water Pipes
The use of high-frequency strain waves to perform examinations and note measurements is referred to as ultrasonic testing (UT). UT is commonly used for the detection or evaluation of flaws and characterization of materials, among other applications. A standard ultrasonic inspection system comprises a pulser/receiver, transducer, and display devices. The pulser/receiver produces electrical pulses of high voltage. The transducer generates high-frequency ultrasonic energy after being driven by the pulser. The reflected wave is then converted into an electrical signal by the transducer and is displayed on a screen. The reflected signal strength versus the time plot helps to glean information regarding the features of a defect. In this paper, we discuss the experiments performed in a laboratory setting to determine ultrasound-based biofilm sensor sensitivity in relation to changes in the surrounding environment of temperature, concentration, turbidity, and conductivity of the liquid passing through the system. The effect of the change in frequency of the sensors was also studied. The sensors being developed are small and compact, portable, can be placed on the outer walls of the desired surface, use digital signal processing techniques, and the biofilm presence on the inner walls of the surface can be monitored.