David Mikolasek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David Mikolasek has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jiri Brozovsky
Department of Structural Mechanics, Faculty of Civil Engineering, VSB – Technical University of Ostrava, Ludvíka Podéště 1875/17, 708 00 Ostrava-Poruba, Czech Republic
14 shared publications - Oldrich Sucharda
Department of Building Materials and Diagnostics of Structures, Faculty of Civil Engineering, VSB-Technical University of Ostrava, Ludvíka Podéště 1875/17, 70800 Ostrava-Poruba, Czech Republic
13 shared publications - Antonín Lokaj
Department of Structures, Faculty of Civil Engineering, VSB-Technical University of Ostrava, 70800 Ostrava-Poruba, Czech Republic
10 shared publications - Marek Johanides
Department of Structures, Faculty of Civil Engineering, VSB-Technical University of Ostrava, 708 00 Ostrava, Czech Republic
7 shared publications - Martin Krejsa
Department of Structural Mechanics, Faculty of Civil Engineering, VŠB—Technical University of Ostrava, L. Podéště 1875, 70800 Ostrava, Czech Republic
7 shared publications - Přemysl Pařenica
VSB - Technical University of Ostrava, Czech Republic
6 shared publications
Latest Publications
- Open Access
- 29 November 2024
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 1 (2)
Research of the Existing Post - tensioned Roof Trusses and their Reliability
The issue of insufficient reliability and, in some cases, the failure of post - tensioned bridge structures, footbridges, and roof trusses, particularly in industrial halls, is one of the current and serious problems of the construction industry in the Czech Republic. The most well - known failures of these structures include the collapse of the Morandi Bridge near Genoa, Italy, in August 2018, and the collapse of the Troja footbridge in Prague in December 2017. Less known are the failures of post - tensioned truss roof structures that occurred in the Czech Republic and Slovakia. Especially in the Czech Republic, there were failures in Tachov (2010 and 2018), Sluknov (December 2023), and Karlovy Vary (March 2024). A common feature of all these failures was the corrosion of the prestressing reinforcement in inadequately grouted cable ducts. Roof structures of this type have been used in more than 100 buildings that are still in operation in the Czech Republic. In response to this situation, the company Rada Building s.r.o., in cooperation with academic institutions, developed a method to reinforce trusses threatened by corrosion using an external steel structure. The company carries out the reinforcement work during normal operation in the hall below the trusses. Research on post - tensioned truss structures and the possibilities of their static securing is being conducted in cooperation with the Faculty of Civil Engineering at VSB – Technical University of Ostrava, the Faculty of Art and Architecture at the Technical University of Liberec, and the company Rada Building, s.r.o. The ambition of the research is to analyze the condition of as many trusses as possible embedded in buildings in the Czech Republic and Slovakia using building structure diagnostic methods and to evaluate these surveys. Furthermore, the research aims to verify the actual behavior of such structures through tests on real trusses taken from demolished buildings. VSB – TU Ostrava has several trusses available, and load tests are currently being carried out on them. An important and final part of the research is to find the optimal diagnostic method that would improve the ability to predict the risk of roof failures in operational buildings and to optimize the methods for securing these structures to ensure full static reliability with the lowest possible costs and minimal impact on the building.
- 29 November 2024
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 1 (2)
Open AccessResearch of the Existing Post - tensioned Roof Trusses and their Reliability
The issue of insufficient reliability and, in some cases, the failure of post - tensioned bridge structures, footbridges, and roof trusses, particularly in industrial halls, is one of the current and serious problems of the construction industry in the Czech Republic. The most well - known failures of these structures include the collapse of the Morandi Bridge near Genoa, Italy, in August 2018, and the collapse of the Troja footbridge in Prague in December 2017. Less known are the failures of post - tensioned truss roof structures that occurred in the Czech Republic and Slovakia. Especially in the Czech Republic, there were failures in Tachov (2010 and 2018), Sluknov (December 2023), and Karlovy Vary (March 2024). A common feature of all these failures was the corrosion of the prestressing reinforcement in inadequately grouted cable ducts. Roof structures of this type have been used in more than 100 buildings that are still in operation in the Czech Republic. In response to this situation, the company Rada Building s.r.o., in cooperation with academic institutions, developed a method to reinforce trusses threatened by corrosion using an external steel structure. The company carries out the reinforcement work during normal operation in the hall below the trusses. Research on post - tensioned truss structures and the possibilities of their static securing is being conducted in cooperation with the Faculty of Civil Engineering at VSB – Technical University of Ostrava, the Faculty of Art and Architecture at the Technical University of Liberec, and the company Rada Building, s.r.o. The ambition of the research is to analyze the condition of as many trusses as possible embedded in buildings in the Czech Republic and Slovakia using building structure diagnostic methods and to evaluate these surveys. Furthermore, the research aims to verify the actual behavior of such structures through tests on real trusses taken from demolished buildings. VSB – TU Ostrava has several trusses available, and load tests are currently being carried out on them. An important and final part of the research is to find the optimal diagnostic method that would improve the ability to predict the risk of roof failures in operational buildings and to optimize the methods for securing these structures to ensure full static reliability with the lowest possible costs and minimal impact on the building.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2950 (1)
The aspects of numerical modelling and testing of timber frame corner with dowel type connections
The research area of timber and timber structures is becoming more and more topical with regard to the sustainable development of buildings. Current research directions also include structural optimization of frame corners. Possible approaches include the use of experimental tests, which are very valuable and time-consuming when it is necessary to use often special preparations. However, before carrying out the experiments, it is advisable to verify the proposed experiment, for example, using numerical modelling. It is appropriate, for example, to use a stability calculation that verified the global and local stability of the structure. However, for a sufficient explanatory value, it is necessary to use advanced 3D computer models, which cover a similar level of structural solution. For these models, it is also necessary to take into account the connecting means and test fixtures. The presented contribution focuses on the mentioned area, which is focused on the experiment carried out, where the of individual parts to the stiffness of the system is verified using numerical modelling and the stability of the entire structure is also verified. The created calculation model respects individual parts in detail up to the level of fasteners and test preparations.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2950 (1)
Open AccessThe aspects of numerical modelling and testing of timber frame corner with dowel type connections
The research area of timber and timber structures is becoming more and more topical with regard to the sustainable development of buildings. Current research directions also include structural optimization of frame corners. Possible approaches include the use of experimental tests, which are very valuable and time-consuming when it is necessary to use often special preparations. However, before carrying out the experiments, it is advisable to verify the proposed experiment, for example, using numerical modelling. It is appropriate, for example, to use a stability calculation that verified the global and local stability of the structure. However, for a sufficient explanatory value, it is necessary to use advanced 3D computer models, which cover a similar level of structural solution. For these models, it is also necessary to take into account the connecting means and test fixtures. The presented contribution focuses on the mentioned area, which is focused on the experiment carried out, where the of individual parts to the stiffness of the system is verified using numerical modelling and the stability of the entire structure is also verified. The created calculation model respects individual parts in detail up to the level of fasteners and test preparations.
- Open Access
Numerical and Experimental Analysis of the Load-Carrying Capacity of a Timber Semi-Rigid Dowel-Type Connection
The paper deals with the analysis of the load-carrying capacity of a timber semi-rigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels, but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace these commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connections was loaded statically, with a slow increase in force until failure. The paper presents results of the experimental testing. Three specimens were made and tested for each type of the connection. Experimental results were subsequently compared with numerical models. The achieved results were also compared with the assumption according to the currently valid standard. The results indicate that a connection using fully threaded screws provides a better load-carrying capacity.
Open AccessNumerical and Experimental Analysis of the Load-Carrying Capacity of a Timber Semi-Rigid Dowel-Type Connection
The paper deals with the analysis of the load-carrying capacity of a timber semi-rigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels, but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace these commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connections was loaded statically, with a slow increase in force until failure. The paper presents results of the experimental testing. Three specimens were made and tested for each type of the connection. Experimental results were subsequently compared with numerical models. The achieved results were also compared with the assumption according to the currently valid standard. The results indicate that a connection using fully threaded screws provides a better load-carrying capacity.
- Open Access
Numerical and Experimental Analysis of the Rotational Stiffness of a Timber Semi-Rigid Dowel-Type Connection
The paper deals with the analysis of the rotational stiffness of a semirigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connection was loaded to the level of 60%, 80%, and 100% of the ultimate limit state value. Subsequently, the rotational stiffness was determined for each load level after five loading and unloading cycles. This paper presents the results and comparison of the experimental testing and the numerical modeling. The obtained results were also compared with the assumption according to the currently valid standard.
Open AccessNumerical and Experimental Analysis of the Rotational Stiffness of a Timber Semi-Rigid Dowel-Type Connection
The paper deals with the analysis of the rotational stiffness of a semirigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connection was loaded to the level of 60%, 80%, and 100% of the ultimate limit state value. Subsequently, the rotational stiffness was determined for each load level after five loading and unloading cycles. This paper presents the results and comparison of the experimental testing and the numerical modeling. The obtained results were also compared with the assumption according to the currently valid standard.
- Open Access
Timber Semirigid Frame Connection with Improved Deformation Capacity and Ductility
The present study deals with the innovation and the possibilities of improving the design solution of a frame connection for two selected types of fasteners. All specimens were made of glued laminated timber. Dowel-type mechanical fasteners, a combination of bolts and dowels, and full-threaded screws were used for the connection. The main goal of this research was to replace the typical solution (common dowel-type fasteners) with a more modern, faster, and easier solution in order to improve the load-carrying capacity, ductility, and deformation capacity of this type of frame connection. This article also aimed to provide a detailed evaluation of the mechanical properties of the used glued laminated timber and fasteners in order to comprehensively evaluate the research task. For the design solution, a frame connection created from a system of two struts and a partition was chosen as the basis of the experimental program. Dowel-type mechanical fasteners, as well as combinations of bolts and dowels, were used for the connection; however, in addition to these standardly used mechanical fasteners, full-threaded screws were used. The article describes the use of static destructive testing to determine the ductility of the connection, considering different variations in the strengthening of the individual segments of the mentioned connection means. In the first variation, the individual components of the frame were not reinforced in any way. In the second, the crossbar was reinforced with two full-threaded bolts. In the third, the webs and the crossbar were reinforced with two full-threaded bolts. In the article, these ductility values were compared with each other and the procedure was set by the currently valid standard.
Open AccessTimber Semirigid Frame Connection with Improved Deformation Capacity and Ductility
The present study deals with the innovation and the possibilities of improving the design solution of a frame connection for two selected types of fasteners. All specimens were made of glued laminated timber. Dowel-type mechanical fasteners, a combination of bolts and dowels, and full-threaded screws were used for the connection. The main goal of this research was to replace the typical solution (common dowel-type fasteners) with a more modern, faster, and easier solution in order to improve the load-carrying capacity, ductility, and deformation capacity of this type of frame connection. This article also aimed to provide a detailed evaluation of the mechanical properties of the used glued laminated timber and fasteners in order to comprehensively evaluate the research task. For the design solution, a frame connection created from a system of two struts and a partition was chosen as the basis of the experimental program. Dowel-type mechanical fasteners, as well as combinations of bolts and dowels, were used for the connection; however, in addition to these standardly used mechanical fasteners, full-threaded screws were used. The article describes the use of static destructive testing to determine the ductility of the connection, considering different variations in the strengthening of the individual segments of the mentioned connection means. In the first variation, the individual components of the frame were not reinforced in any way. In the second, the crossbar was reinforced with two full-threaded bolts. In the third, the webs and the crossbar were reinforced with two full-threaded bolts. In the article, these ductility values were compared with each other and the procedure was set by the currently valid standard.
- Open Access
Load-Carrying Capacity of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared and Round Timber Based on the Experimental Testing, European Yield Model, and Linear Elastic Fracture Mechanics
Nowadays, the use of timber as a building material is gaining more prominence. When designing timber structures, it is necessary to pay increased attention to the design of their connections. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber and round timber with slotted-in steel plates. Several variants of connections with different distances between the fastener and the loaded end were selected for the experimental testing. A total of six types of test specimens were made from spruce timber, for which their selected physical properties were determined and evaluated before the experimental testing. Test specimens of bolted connections were first tested in tension parallel to the grain until failure under quasi-static loading. The connections were broken by splitting. Ductile failure preceded brittle failure. The actual load-carrying capacities were lowest for the lowest end distance. The load-carrying capacities for the middle and the longest end distances were comparable. The results of the experiments were then used for comparison with calculation procedures according to the standard for the design of timber structures and with calculations according to the theory of linear elastic fracture mechanics. The experiments and the analytical models were supported by a simple numerical analysis based on the finite element method.
Open AccessLoad-Carrying Capacity of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared and Round Timber Based on the Experimental Testing, European Yield Model, and Linear Elastic Fracture Mechanics
Nowadays, the use of timber as a building material is gaining more prominence. When designing timber structures, it is necessary to pay increased attention to the design of their connections. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber and round timber with slotted-in steel plates. Several variants of connections with different distances between the fastener and the loaded end were selected for the experimental testing. A total of six types of test specimens were made from spruce timber, for which their selected physical properties were determined and evaluated before the experimental testing. Test specimens of bolted connections were first tested in tension parallel to the grain until failure under quasi-static loading. The connections were broken by splitting. Ductile failure preceded brittle failure. The actual load-carrying capacities were lowest for the lowest end distance. The load-carrying capacities for the middle and the longest end distances were comparable. The results of the experiments were then used for comparison with calculation procedures according to the standard for the design of timber structures and with calculations according to the theory of linear elastic fracture mechanics. The experiments and the analytical models were supported by a simple numerical analysis based on the finite element method.
- Open Access
Rotational Stiffness and Carrying Capacity of Timber Frame Corners with Dowel Type Connections
With the development of wooden structures and buildings, there is a need to research physical and numerical tests of wood-based structures. The presented research is focused on construction and computational approaches for new types of joints to use in wooden structures, particularly glued lamella elements made of wood and wood-based composites. This article focuses on improving the frame connection of a wooden post and a beam with the use of fasteners to ensure better load-bearing capacity and stiffness of the structure. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The aim is to replace these commonly used fasteners with modern ones, namely full thread screws. The aim is also to shorten and simplify the assembly time in order to improve the load-bearing capacity and rigidity of this type of frame connection. Two variations of the experimental test were tested in this research. The first contained bolts and pins as connecting means and the second contained the connecting means of a full threaded screw. Each experiment contained a total of two tests. For a detailed study of the problem, we used a 2D or 3D computational model that models individual components, including fasteners.
Open AccessRotational Stiffness and Carrying Capacity of Timber Frame Corners with Dowel Type Connections
With the development of wooden structures and buildings, there is a need to research physical and numerical tests of wood-based structures. The presented research is focused on construction and computational approaches for new types of joints to use in wooden structures, particularly glued lamella elements made of wood and wood-based composites. This article focuses on improving the frame connection of a wooden post and a beam with the use of fasteners to ensure better load-bearing capacity and stiffness of the structure. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The aim is to replace these commonly used fasteners with modern ones, namely full thread screws. The aim is also to shorten and simplify the assembly time in order to improve the load-bearing capacity and rigidity of this type of frame connection. Two variations of the experimental test were tested in this research. The first contained bolts and pins as connecting means and the second contained the connecting means of a full threaded screw. Each experiment contained a total of two tests. For a detailed study of the problem, we used a 2D or 3D computational model that models individual components, including fasteners.
- Open Access
- 25 December 2020
- Published by MDPI AG in Sustainability
- Vol. 13 (1) , 156
Analysis of Rotational Stiffness of the Timber Frame Connection
Initially, timber was considered only as an easily accessible and processable material in nature; however, its excellent properties have since become better understood. During the discovery of new building materials and thanks to new technological development processes, industrial processing technologies and gradually drastically decreasing forest areas, wood has become an increasingly neglected material. Load-bearing structures are made mostly of reinforced concrete or steel elements. However, ecological changes, the obvious problems associated with environmental pollution and climate change, are drawing increasing attention to the importance of environmental awareness. These factors are attracting increased attention to wood as a building material. The increased demand for timber as a building material offers the possibility of improving its mechanical and physical properties, and so new wood-based composite materials or new joints of timber structures are being developed to ensure a better load capacity and stiffness of the structure. Therefore, this article deals with the improvement of the frame connection of the timber frame column and a diaphragm beam using mechanical fasteners. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The subject of the research and its motivation was to replace these commonly used fasteners with more modern ones to shorten and simplify the assembly time and to improve the load capacity and rigidity of this type of frame connection.
- 25 December 2020
- Published by MDPI AG in Sustainability
- Vol. 13 (1) , 156
Open AccessAnalysis of Rotational Stiffness of the Timber Frame Connection
Initially, timber was considered only as an easily accessible and processable material in nature; however, its excellent properties have since become better understood. During the discovery of new building materials and thanks to new technological development processes, industrial processing technologies and gradually drastically decreasing forest areas, wood has become an increasingly neglected material. Load-bearing structures are made mostly of reinforced concrete or steel elements. However, ecological changes, the obvious problems associated with environmental pollution and climate change, are drawing increasing attention to the importance of environmental awareness. These factors are attracting increased attention to wood as a building material. The increased demand for timber as a building material offers the possibility of improving its mechanical and physical properties, and so new wood-based composite materials or new joints of timber structures are being developed to ensure a better load capacity and stiffness of the structure. Therefore, this article deals with the improvement of the frame connection of the timber frame column and a diaphragm beam using mechanical fasteners. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The subject of the research and its motivation was to replace these commonly used fasteners with more modern ones to shorten and simplify the assembly time and to improve the load capacity and rigidity of this type of frame connection.
- Open Access
- 9 November 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (21) , 9288
Analysis of Longitudinal Timber Beam Joints Loaded with Simple Bending
The joints in timber structures are often the decisive factor in determining the load-bearing capacity, rigidity, sustainability, and durability of timber structures. Compared with the fasteners used for steel and concrete structures, fasteners for timber structures generally have a lower load-bearing capacity and rigidity, with the exception of glued joints. Glued joints in timber structures constitute a diverse group of rigid joints which are distinguished by sudden failure when the joint’s load-bearing capacity is reached. In this contribution, the load-bearing capacity of a longitudinal joint for a beam under simple flexural stress is analyzed using glued, double-sided splices. Joints with double-sided splices and connecting screws were also tested to compare the load-bearing capacity and rigidity. A third series of tests was carried out on joints made using glued double-sided splices augmented with screws. The aim of this combined joint was to ensure greater ductility after the load-bearing capacity of the glued splice joint had been reached.
- 9 November 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (21) , 9288
Open AccessAnalysis of Longitudinal Timber Beam Joints Loaded with Simple Bending
The joints in timber structures are often the decisive factor in determining the load-bearing capacity, rigidity, sustainability, and durability of timber structures. Compared with the fasteners used for steel and concrete structures, fasteners for timber structures generally have a lower load-bearing capacity and rigidity, with the exception of glued joints. Glued joints in timber structures constitute a diverse group of rigid joints which are distinguished by sudden failure when the joint’s load-bearing capacity is reached. In this contribution, the load-bearing capacity of a longitudinal joint for a beam under simple flexural stress is analyzed using glued, double-sided splices. Joints with double-sided splices and connecting screws were also tested to compare the load-bearing capacity and rigidity. A third series of tests was carried out on joints made using glued double-sided splices augmented with screws. The aim of this combined joint was to ensure greater ductility after the load-bearing capacity of the glued splice joint had been reached.
- 10 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1978 (1) , 150007
Influence of initial imperfections on the behavior of the welded joint
The article deals with the numerical modeling of steel welded supporting components using commercial software system ANSYS, which is based on the finite element method - FEM. The results of numerical analysis are compared and checked with the results of physical verification test, in which the real behavior of the welded joint in bearing element is observed. The paper is also focused on the influence of geometrical imperfections on the resulting stress-strain behavior of the specimen. The results of the experiment are also used for calibration of the computational model under discussion.
- 10 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1978 (1) , 150007
Influence of initial imperfections on the behavior of the welded joint
The article deals with the numerical modeling of steel welded supporting components using commercial software system ANSYS, which is based on the finite element method - FEM. The results of numerical analysis are compared and checked with the results of physical verification test, in which the real behavior of the welded joint in bearing element is observed. The paper is also focused on the influence of geometrical imperfections on the resulting stress-strain behavior of the specimen. The results of the experiment are also used for calibration of the computational model under discussion.