Kazutaka Masamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kazutaka Masamoto has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Bungo Otsuki
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
5 shared publicationsShuichi Matsuda
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
5 shared publicationsShunsuke Fujibayashi
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
5 shared publicationsYu Shimizu
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
4 shared publicationsTakayoshi Shimizu
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
3 shared publications- Kazuaki Morizane
Department of Orthopedic Surgery, Gakken Toshi Hospital, Kyoto, Japan
2 shared publications
Latest Publications
- 6 August 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (2) , 238-245
Bioactivity and antibacterial activity of strontium and silver ion releasing titanium
To overcome problems associated with loosening of orthopedic implants and surgical site infections, we developed a novel, titanium (Ti)‐based material that releases both strontium and silver ions (CaSrAg–Ti) based on alkali‐and‐heat treatment. The results of commercially pure Ti (cp–Ti), Ti that releases Sr ions only (CaSr–Ti), and the novel CaSrAg–Ti material were compared. Mechanical tests were performed to evaluate the in vivo bonding properties of CaSrAg–Ti and the bone‐implant contact (BIC) ratio in histological specimens was determined at 4 and 8 weeks after implantation in a rat femur. Also, the in vitro antibacterial activities of this material against methicillin‐susceptible Staphylococcus aureus (MSSA) were evaluated after a 24 h incubation period by assaying colony‐forming units. In addition, antibacterial activities were evaluated in vivo at 7 days after implantation in a rat subcutaneous pocket model. There was direct contact between the bone and CaSrAg–Ti in histological specimens and no apparent signs of argyrosis in any rat. The bone‐bonding strength and the BIC ratio were increased by 2.7‐ and 2.3‐fold for CaSrAg–Ti vs. cp‐Ti at 4 weeks and 2.2‐ and 2.0‐fold at 8 weeks, respectively. As compared with cp‐Ti, the number of viable MSSA remaining on CaSrAg–Ti was reduced by 100 ± 0% in vitro and 94.2 ± 6.9% in vivo. Ti that releases Sr and Ag ions is a promising material that exhibits both bone‐bonding properties and anti‐MSSA activities.
- 6 August 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (2) , 238-245
Bioactivity and antibacterial activity of strontium and silver ion releasing titanium
To overcome problems associated with loosening of orthopedic implants and surgical site infections, we developed a novel, titanium (Ti)‐based material that releases both strontium and silver ions (CaSrAg–Ti) based on alkali‐and‐heat treatment. The results of commercially pure Ti (cp–Ti), Ti that releases Sr ions only (CaSr–Ti), and the novel CaSrAg–Ti material were compared. Mechanical tests were performed to evaluate the in vivo bonding properties of CaSrAg–Ti and the bone‐implant contact (BIC) ratio in histological specimens was determined at 4 and 8 weeks after implantation in a rat femur. Also, the in vitro antibacterial activities of this material against methicillin‐susceptible Staphylococcus aureus (MSSA) were evaluated after a 24 h incubation period by assaying colony‐forming units. In addition, antibacterial activities were evaluated in vivo at 7 days after implantation in a rat subcutaneous pocket model. There was direct contact between the bone and CaSrAg–Ti in histological specimens and no apparent signs of argyrosis in any rat. The bone‐bonding strength and the BIC ratio were increased by 2.7‐ and 2.3‐fold for CaSrAg–Ti vs. cp‐Ti at 4 weeks and 2.2‐ and 2.0‐fold at 8 weeks, respectively. As compared with cp‐Ti, the number of viable MSSA remaining on CaSrAg–Ti was reduced by 100 ± 0% in vitro and 94.2 ± 6.9% in vivo. Ti that releases Sr and Ag ions is a promising material that exhibits both bone‐bonding properties and anti‐MSSA activities.
- 9 May 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (11) , 2804-2813
Cervical spinal computed tomography utilizing model-based iterative reconstruction reduces radiation to an equivalent of three cervical X-rays
Purpose To evaluate radiation dose and image quality of cervical spinal computed tomography scanned with low-radiation dose (LD-CT) utilizing model-based iterative reconstruction (MBIR). Methods We retrospectively examined 14 patients (65.5 ± 13.9 years) who underwent both standard-radiation-dose CT (SD-CT) reconstructed with hybrid iterative reconstruction and LD-CT of cervical spine. The radiation dose, objective image quality indicator, which includes signal-to-noise and contrast-to-noise, and subjective image quality score of the anatomical landmarks in the SD-CT and LD-CT were statistically compared. In addition, the measurement errors of the length of C3 vertebrae (height, anteroposterior length, inner and outer pedicle diameters) between SD-CT and LD-CT were analyzed. Results Radiation dose of LD-CT was reduced to one-sixth of the dose of SD-CT. The objective image quality indicator of LD-CT was significantly better than that of SD-CT. The subjective image quality of LD-CT was relatively worse than that of SD-CT but generally graded as clinically accepted or higher. There was no remarkable difference between SD-CT and LD-CT in the measurement value of height and anteroposterior length. Inner pedicle diameter was significantly (0.21 ± 0.13 mm) smaller, and outer pedicle diameter was (0.24 ± 0.14 mm) larger on LD-CT than on SD-CT. Conclusion Cervical spinal LD-CT that utilized MBIR enabled radical decrease in radiation dose and provided sufficient image quality for clinical use. This scanning protocol can be a good alternative for protecting patients from exposure to unnecessary radiation, especially when a patient requires multiple CT scans.
- 9 May 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (11) , 2804-2813
Cervical spinal computed tomography utilizing model-based iterative reconstruction reduces radiation to an equivalent of three cervical X-rays
Purpose To evaluate radiation dose and image quality of cervical spinal computed tomography scanned with low-radiation dose (LD-CT) utilizing model-based iterative reconstruction (MBIR). Methods We retrospectively examined 14 patients (65.5 ± 13.9 years) who underwent both standard-radiation-dose CT (SD-CT) reconstructed with hybrid iterative reconstruction and LD-CT of cervical spine. The radiation dose, objective image quality indicator, which includes signal-to-noise and contrast-to-noise, and subjective image quality score of the anatomical landmarks in the SD-CT and LD-CT were statistically compared. In addition, the measurement errors of the length of C3 vertebrae (height, anteroposterior length, inner and outer pedicle diameters) between SD-CT and LD-CT were analyzed. Results Radiation dose of LD-CT was reduced to one-sixth of the dose of SD-CT. The objective image quality indicator of LD-CT was significantly better than that of SD-CT. The subjective image quality of LD-CT was relatively worse than that of SD-CT but generally graded as clinically accepted or higher. There was no remarkable difference between SD-CT and LD-CT in the measurement value of height and anteroposterior length. Inner pedicle diameter was significantly (0.21 ± 0.13 mm) smaller, and outer pedicle diameter was (0.24 ± 0.14 mm) larger on LD-CT than on SD-CT. Conclusion Cervical spinal LD-CT that utilized MBIR enabled radical decrease in radiation dose and provided sufficient image quality for clinical use. This scanning protocol can be a good alternative for protecting patients from exposure to unnecessary radiation, especially when a patient requires multiple CT scans.
- 1 January 2020
- Published by Wolters Kluwer Health in Spine
- Vol. 45 (1) , 38-47
Utility of Thoracolumbar Low-Dose CT With Model-Based Iterative Reconstruction for Measuring Pedicle Diameter Using a Radiation Dose Less Than a One-Time Lumbar X-Ray
Study Design.: Retrospective. Objective.: To evaluate the image quality of low-radiation-dose computed tomography (LD-CT) of the thoracolumbar spine, using model-based iterative reconstruction (MBIR) for measuring pedicle diameter. Summary of Background Data.: MBIR can drastically reduce radiation dose but its utility in spine surgery planning is unknown. Methods.: We identified patients (mean age, 70.5 ± 13.3 yrs) who incidentally underwent both standard-radiation-dose CT (SD-CT) with hybrid iterative reconstruction and LD-CT with MBIR of the thoracolumbar spine within 2 years. We compared radiation dose, subjective image sharpness, signal-to-noise ratio, and contrast-to-noise ratio for the two tests. Additionally, inner pedicle diameters were measured on SD-CT (DSD) and LD-CT (DLD), and statistically compared. Results.: We included 24 CT and 84 pedicles for each CT group. The radiation dose of LD-CT estimated by volume CT dose index was 1.21 ± 0.42 mGy, one-sixth the dose of SD-CT. The effective dose of LD-CT was 0.58 ± 0.31 mSv, equivalent to or less than that of a one-time lumbar X-ray in a previous report. LD-CT was significantly inferior in subjective image sharpness for the contour of vertebrae and trabecular structure, but superior for signal-to-noise ratio and contrast-to-noise ratio. The intra-rater reliability (intra-RR) and inter-RR for DLD were 0.985 and 0.892, respectively, comparable to those of DSD. DLD was consistently 0.30 mm smaller than DSD when compared within the same pedicle, regardless of pedicle diameter. Conclusion.: LD-CT with MBIR produced a radiation dose equivalent to a one-time lumbar X-ray and provided excellent images for measuring pedicle diameter. LD-CT can be a substitute for SD-CT when planning spine surgery if the relationship between DSD and DLD is sufficiently understood. Level of Evidence: 3
- 1 January 2020
- Published by Wolters Kluwer Health in Spine
- Vol. 45 (1) , 38-47
Utility of Thoracolumbar Low-Dose CT With Model-Based Iterative Reconstruction for Measuring Pedicle Diameter Using a Radiation Dose Less Than a One-Time Lumbar X-Ray
Study Design.: Retrospective. Objective.: To evaluate the image quality of low-radiation-dose computed tomography (LD-CT) of the thoracolumbar spine, using model-based iterative reconstruction (MBIR) for measuring pedicle diameter. Summary of Background Data.: MBIR can drastically reduce radiation dose but its utility in spine surgery planning is unknown. Methods.: We identified patients (mean age, 70.5 ± 13.3 yrs) who incidentally underwent both standard-radiation-dose CT (SD-CT) with hybrid iterative reconstruction and LD-CT with MBIR of the thoracolumbar spine within 2 years. We compared radiation dose, subjective image sharpness, signal-to-noise ratio, and contrast-to-noise ratio for the two tests. Additionally, inner pedicle diameters were measured on SD-CT (DSD) and LD-CT (DLD), and statistically compared. Results.: We included 24 CT and 84 pedicles for each CT group. The radiation dose of LD-CT estimated by volume CT dose index was 1.21 ± 0.42 mGy, one-sixth the dose of SD-CT. The effective dose of LD-CT was 0.58 ± 0.31 mSv, equivalent to or less than that of a one-time lumbar X-ray in a previous report. LD-CT was significantly inferior in subjective image sharpness for the contour of vertebrae and trabecular structure, but superior for signal-to-noise ratio and contrast-to-noise ratio. The intra-rater reliability (intra-RR) and inter-RR for DLD were 0.985 and 0.892, respectively, comparable to those of DSD. DLD was consistently 0.30 mm smaller than DSD when compared within the same pedicle, regardless of pedicle diameter. Conclusion.: LD-CT with MBIR produced a radiation dose equivalent to a one-time lumbar X-ray and provided excellent images for measuring pedicle diameter. LD-CT can be a substitute for SD-CT when planning spine surgery if the relationship between DSD and DLD is sufficiently understood. Level of Evidence: 3
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 48-59
In vivo and in vitro bioactivity of a “precursor of apatite” treatment on polyetheretherketone
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 48-59
In vivo and in vitro bioactivity of a “precursor of apatite” treatment on polyetheretherketone
- 28 November 2017
- Published by Springer Nature in European Spine Journal
- Vol. 27 (2) , 406-415
Factors influencing spinal sagittal balance, bone mineral density, and Oswestry Disability Index outcome measures in patients with rheumatoid arthritis
To identify the factors influencing spinal sagittal alignment, bone mineral density (BMD), and Oswestry Disability Index (ODI) outcome measures in patients with rheumatoid arthritis (RA).
- 28 November 2017
- Published by Springer Nature in European Spine Journal
- Vol. 27 (2) , 406-415
Factors influencing spinal sagittal balance, bone mineral density, and Oswestry Disability Index outcome measures in patients with rheumatoid arthritis
To identify the factors influencing spinal sagittal alignment, bone mineral density (BMD), and Oswestry Disability Index (ODI) outcome measures in patients with rheumatoid arthritis (RA).